Permit #2017081142
Permit Details
Status: COED
| Parcel Id: 33-11-31-3061-00020-0080 |
| CONDITIONED SPACE: 2443 sqft |
| CONDITIONED SPACE: 269 sqft |
| GARAGE: 764 sqft |
| OPENED PORCH (WITH ROOF) : 442 sqft |
| OPENED PORCH (WITH ROOF) : 91 sqft |
| Total Square Footage: 4009 sqft |
| Block: 00020 |
| Subdivision: 2108 - Hidden Lakes- Phase II-Toscana |
| Job Phone: 863-420-2100 |
| Location Address: 24 NEW WATER OAK DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/13/2017 |
| NOC: RECORDED |
| Applicant name: YUVAL BOTANSKY |
| Owner: APPLIED BUILDING DEVELOPMENT OF ORLANDO - PC INC |
|
Address 131 CHADWICK DRIVE DAVENPORT, FL 33837 |
| Lot: 0080 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
APPLIED BUILDING DEVELOPMENT COMPANY - OAKHILLS IN
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
131 CHADWICK DRIVE DAVENPORT, FL 33837 |
CRC1330762 (Exp: 08/31/2026) | 863-420-2100 | 386-517-6865 |
Sub Contractors
TERRY HILE BURD
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO Box 180308 CASSELBERRY, FL 32707 |
CAC1814423 (Exp: 08/31/2024) | (407) 831-3600 | (407)831-2893 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
SANTOS L HERNANDEZ
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
946 SHADDICK DRIVE ORANGE CITY, FL 32763 |
CCC1328011 (Exp: 08/31/2026) | 386-218-4942 | 386-218-4937 |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| CANCEL |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2022) | 877-906-1113 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 08/15/2018 | FINAL APPROVED | WMILLER |
| BLD - BUILDING FINAL | 08/09/2018 | CANCELLED BY APPLICANT | CMINI |
| BLD - BUILDING FINAL | 08/02/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: MODEL NUMBER ON ENERGY CALC DOES NOT MATCH MODEL INSTALLED, MAKE CONDITIONS AT SITE MATCH APPROVED SUBMITTALS OR OBTAIN REVISION WITH CORRECT MODEL NUMBERS | |||
| U-CROSS CONNECTION | 08/01/2018 | FINAL APPROVED | LFITZGERALD |
| ROW - FINAL APRON (AFTER POUR) | 08/01/2018 | APPROVED | KHOWELL |
| ROW - FINAL INSPECTION | 08/01/2018 | FINAL APPROVED | KHOWELL |
| U -UTILITY RESIDENTIAL FINAL | 08/01/2018 | FINAL APPROVED | LFITZGERALD |
| Note: NOTE: water meter pit about 3-4 inches too high-i was informed by ABD rep.-Mason that during install , he advised the utility installers that it was too high but they set it at the present elevation. I confirmed that with Mike Hughes that there is a w/o to utility's by builder to lower when time permits. | |||
| FINAL SURVEY (OFFICE USE ONLY) | 07/31/2018 | APPROVED | DREWIS |
| TUB SET | 07/25/2018 | APPROVED | JGIBSON |
| ROW- PRE-APRON (PRE-POUR) | 07/24/2018 | APPROVED | KHOWELL |
| ROW- PRE-APRON (PRE-POUR) | 07/23/2018 | CANCELLED BY APPLICANT | RGROSS |
| ROW- PRE-APRON (PRE-POUR) | 07/18/2018 | PARTIALLY APPROVED | KHOWELL |
| Note: APRON AND SIDEWALK POUR ONLY PAVER DRIVEWAY | |||
| ELECTRIC - EARLY POWER | 06/29/2018 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO SUSAN FPL RELEASED EARLY POWER 4:00 | |||
| GRAVITY SEWER TEST | 06/06/2018 | APPROVED | JGIBSON |
| U - SEWER TIE IN | 06/06/2018 | APPROVED | DSPENCER |
| TIE BEAM / LINTEL | 05/30/2018 | APPROVED - AS NOTED | CMINI |
| Note: pool wall completion | |||
| LATH/BRICK/ WATER BARRIER | 05/04/2018 | APPROVED | CMINI |
| INSULATION | 04/30/2018 | APPROVED | CMINI |
| ALL ROUGH | 04/26/2018 | APPROVED | CMINI |
| ALL ROUGH | 04/25/2018 | Disapproved -FEE REQUIRED | CMINI |
| Note: arch windows not screwed and missing furring strips check all | |||
| ROOF VALLEY & METAL | 04/24/2018 | APPROVED | CMINI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/20/2018 | APPROVED | CMINI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/13/2018 | Disapproved -FEE REQUIRED | CMINI |
| Note: missing straps on trusses, copola not complete, sill plate for truss gables not complete, can not see connections at front entry, incomplete inspection, not read | |||
| ELECTRIC-TUG | 04/13/2018 | APPROVED - AS NOTED | CMINI |
| Note: called Del from fpl to release | |||
| ROOF SHEATHING | 02/07/2018 | APPROVED | CMINI |
| TIE BEAM / LINTEL | 01/29/2018 | APPROVED | CMINI |
| MONOLITHIC SLAB | 01/09/2018 | APPROVED | CMINI |
| PLUMBING 1ST ROUGH UNDERGROUND | 12/27/2017 | APPROVED - AS NOTED | JGIBSON |
| Note: NEED REVISION TO SHOW SANITARY EXITING BUILDING TWICE INSTEAD OF ONCE LIKE RISER SHOWS | |||
| FOUND SURVEY APPROVED (OFFICE) | 12/22/2017 | APPROVED | JHINDMAN |
| FOOTER | 11/03/2017 | APPROVED | CMINI |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 08/14/2018 | 08/14/2018 |
| Note: Released By: FREODICA Revision: changed energy calculations. | |||
| MECH | HOLD | 08/10/2018 | 08/13/2018 |
| Note: Held By: FREODICA Coorection to revision: 1. Provide energy calculations using the applicablle Form R405-2014 as the permit still under 2014 code. 2. Provide consistent/coordinated information between energy calculations and equipment sizing calculations to the following items per FBC 6th ed. 107.1 a. Project location (address) b. Project design location (climate zone for summer design conditions). Use Daytona Beach, Flrida or St. Augustine, Florida per FBCEC 6th ed. R301. F.Reodica -386-986-4734. | |||
| MECH | HOLD | 08/08/2018 | 08/09/2018 |
| Note: Held By: FREODICA Review comments on correction to revision of energy calculations.: 1. Florida energy code compliance certification shall be signed by the owner/agent per FBCEC 6th ed. R405.3. 2. Energy performance level (EPL) display card shall be signed by builder per FBCEC 6th ed. R401.3 3. The total capacity of selected hvac units shown on energy calculation and EPL display card does not match with those shown on equipment sizing calculation. Coordinate per FBC 6th ed. 107.1. F.Reodica -386-986-4734. | |||
| MECH | HOLD | 08/02/2018 | 08/07/2018 |
| Note: Held By: FREODICA Revision:: changed energy calculations: 1. The cooling capacity of selected hvac units is 1.15 times greater than the calculated total cooling load which does not comply with FBCEC 6th ed. R403.7.1.1. 2. The referenced design location on energy calculation shows Orlando, FL. but the sizing calculation shows Daytona, Beach, FL. Coordinate and use Daytona Beach, FL per FBCEC 6th ed. R301. F.Reodica -386-986-4734. | |||
| SW1 | COMPLETE | 07/30/2018 | 07/31/2018 |
| Note: Released By: DREWIS Final survey | |||
| PLUM | HOLD | 02/02/2018 | 02/06/2018 |
| Note: Held By: FREODICA Revision- Sanitary riser diagram. The revised sanitary riser diagram shows (2) powder room but floor plan shows only one. Coordinate for clarity.FBC 6th ed. 107.2.1. F.Reodica -386-986-4734. | |||
| SW1 | COMPLETE | 12/22/2017 | 12/22/2017 |
| Note: Released By: JHINDMAN foudnation | |||
| ZON | COMPLETE | 10/06/2017 | 10/06/2017 |
| Note: Released By: TAWILLIAMS | |||
| MECH | COMPLETE | 10/06/2017 | 10/13/2017 |
| Note: Released By: FREODICA | |||
| BLD | COMPLETE | 10/06/2017 | 10/10/2017 |
| Note: Released By: JHINDMAN | |||
| URB | COMPLETE | 08/31/2017 | 09/18/2017 |
| Note: Released By: JBEAUDET | |||
| BLD | HOLD | 08/30/2017 | 09/06/2017 |
| Note: Held By: FREODICA If the house has unvented attic, provide manufacturer's specification and installation instructions of spray foam insulation per FBCR 5th ed. R316. See also mechanical comments. F.Reodica -386-986-4734. | |||
| ELEC | COMPLETE | 08/30/2017 | 09/14/2017 |
| Note: Released By: JHINDMAN | |||
| ENGIN1 | COMPLETE | 08/30/2017 | 08/30/2017 |
| Note: Released By: TBAKER | |||
| MECH | HOLD | 08/30/2017 | 09/06/2017 |
| Note: Held By: FREODICA 1. Energy calculations show vented attic but plans show unvented attic. Coordinate and submit correction per FBC 5th ed. 107.2.1. 2. Coordinate the ceiling height of living room on enery calculations with floor plan for clarity per FBC 5th ed. 107.2.1. 3. Provide the addrees of the new house on energy performance level (EPL) display card per FBC 5th ed. FBCEC 5th ed. 401.3. F.Reodica -386-986-4734. | |||
| PLUM | COMPLETE | 08/30/2017 | 09/06/2017 |
| Note: Released By: FREODICA | |||
| SW1 | COMPLETE | 08/30/2017 | 09/14/2017 |
| Note: Released By: JHINDMAN | |||
| UD1 | COMPLETE | 08/30/2017 | 09/01/2017 |
| Note: Released By: MBACON This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. | |||
| ZON | HOLD | 08/30/2017 | 08/31/2017 |
| Note: Held By: TAWILLIAMS Wrong FIRm panel number on site plan |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REVISION | ¤40.00 | 08/14/2018 |
| REINSPECTION FEE | ¤40.00 | 08/03/2018 |
| REINSPECTION FEE | ¤40.00 | 08/01/2018 |
| REINSPECTION FEE | ¤40.00 | 08/01/2018 |
| NEW RESIDENTIAL INSPECTIONS | ¤708.00 | 10/13/2017 |
| SITE PLAN 20 | ¤20.00 | 10/13/2017 |
| SURCHARGE FS 533.721 | ¤17.07 | 10/13/2017 |
| SURCHARGE - FS 468.631 | ¤25.60 | 10/13/2017 |
| STORM WATER PERMIT FEES | ¤80.00 | 10/13/2017 |
| 3% TRANS IMPACT FEE CREDIT | (¤93.74) | 10/13/2017 |
| ADMIN FEE | ¤20.00 | 10/13/2017 |
| ELECTRIC FEE | ¤272.40 | 10/13/2017 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.56) | 10/13/2017 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤218.79 | 10/13/2017 |
| IMPACT FEE PARKS | ¤849.24 | 10/13/2017 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 10/13/2017 |
| IMPACT FEE TRANSPORTATION | ¤3,124.67 | 10/13/2017 |
| MECHANICAL FEE | ¤272.40 | 10/13/2017 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 10/13/2017 |
| PLAN CHECK FEE | ¤141.60 | 10/13/2017 |
| PLUMBING FEE | ¤272.40 | 10/13/2017 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,656.39 |