I want to search for...

Permit #2017090491

Permit Details

Status: COED

Parcel Id: 33-11-31-3061-00010-0160
CONDITIONED SPACE: 2443 sqft
CONDITIONED SPACE: 269 sqft
GARAGE: 764 sqft
OPENED PORCH (WITH ROOF) : 91 sqft
OPENED PORCH (WITH ROOF) : 442 sqft
Total Square Footage: 4009 sqft
Block: 00010
Subdivision: 2108 - Hidden Lakes- Phase II-Toscana
Job Phone: 863-420-2100
Location Address: 31 NEW LEATHERWOOD DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/07/2017
NOC: RECORDED
Applicant name: YUVAL BOTANSKY
Owner: APPLIED BUILDING DEVELOPMENT OF ORLANDO - PC INC

Address

131 CHADWICK DRIVE

DAVENPORT, FL 33837

Lot: 0160
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

APPLIED BUILDING DEVELOPMENT COMPANY - OAKHILLS IN
Status Location Address State License Number Phone Fax
ACTIVE

131 CHADWICK DRIVE

DAVENPORT, FL 33837

CRC1330762 (Exp: 08/31/2026) 863-420-2100 386-517-6865

Sub Contractors

TERRY HILE BURD
Status Location Address State License Number Phone Fax
INACTIVE

PO Box 180308

CASSELBERRY, FL 32707

CAC1814423 (Exp: 08/31/2024) (407) 831-3600 (407)831-2893
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937
JOSEPH H STRADA JR
Status Location Address State License Number Phone
CANCEL

3400 ST JOHNS PKWY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2022) 877-906-1113

Inspection History

Type Request Date Result Inspector
U-CROSS CONNECTION 11/30/2018 APPROVED LFITZGERALD
U -UTILITY RESIDENTIAL FINAL 11/30/2018 FINAL APPROVED LFITZGERALD
U -UTILITY RESIDENTIAL FINAL 11/29/2018 CANCELLED BY APPLICANT LFITZGERALD
U-CROSS CONNECTION 11/29/2018 CANCELLED BY APPLICANT LFITZGERALD
BLD - BUILDING FINAL 11/29/2018 APPROVED MWILLIAMS
U-CROSS CONNECTION 11/28/2018 Disapproved - NO FEE LFITZGERALD
Note: Re-use meter/pit not yet installed-utility dept. informed
BLD - BUILDING FINAL 11/28/2018 Disapproved -FEE REQUIRED WMILLER
Note: TO MANY DEFICIENT ITEMS, INSPECTION STOPPED, INCOMPLETE LIST, 1. ADDRESS NUMBERS, SITE ADDRESS NUMBERS FBC R319. 2. WEATHER STRIPPING NEEDS TO BE INSTALLED R 612.1 FBC 3. HOSE BIBB, VACUUM BREAKER 2902.4.3 , REQUIRED 4. GARAGE DOOR SELF-CLOSING DEVICES R302.5.1
ROW - FINAL APRON (AFTER POUR) 11/28/2018 APPROVED KHOWELL
ROW - FINAL INSPECTION 11/28/2018 FINAL APPROVED KHOWELL
U -UTILITY RESIDENTIAL FINAL 11/28/2018 Disapproved - NO FEE LFITZGERALD
Note: Utility re-use meter/pit not yet installed-must be in to inspect for re-use inspection. Utility dept. informed
FINAL SURVEY (OFFICE USE ONLY) 11/27/2018 APPROVED DREWIS
ROW- PRE-APRON (PRE-POUR) 11/13/2018 APPROVED KHOWELL
TUB SET 11/08/2018 APPROVED JGIBSON
ROW- PRE-APRON (PRE-POUR) 11/02/2018 PARTIALLY APPROVED KHOWELL
Note: APRON AND SIDEWALK ONLY PAVER UPPER DRIVEWAY
ROW- PRE-APRON (PRE-POUR) 11/01/2018 CANCELLED BY APPLICANT RGROSS
ELECTRIC - EARLY POWER 10/31/2018 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED EARLY POWER 3:00
TIE BEAM / LINTEL 10/18/2018 APPROVED - AS NOTED CMINI
Note: pool area
GRAVITY SEWER TEST 09/25/2018 APPROVED JGIBSON
U - SEWER TIE IN 09/25/2018 APPROVED LFITZGERALD
LATH/BRICK/ WATER BARRIER 09/13/2018 APPROVED CMINI
INSULATION 09/12/2018 APPROVED CMINI
INSULATION 09/11/2018 Disapproved -FEE REQUIRED CMINI
Note: house spray foamed, need calcs on site
ROOF VALLEY & METAL 08/29/2018 APPROVED WMILLER
Note: approved
INSULATION 08/24/2018 Disapproved -FEE REQUIRED CMINI
Note: need to revise energy calcs and plans to show unvented attic space
ALL ROUGH 08/22/2018 APPROVED CMINI
ELECTRIC-TUG 08/22/2018 APPROVED - AS NOTED CMINI
Note: called fpl to release, Susan
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/10/2018 APPROVED CMINI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/08/2018 Disapproved -FEE REQUIRED CMINI
Note: need to correct structual fascia, missing straps on garage trusses circled on plan
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/06/2018 CANCELLED BY APPLICANT WEB
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/03/2018 CANCELLED BY APPLICANT WMILLER
Note: CANCELLED PER JOSH
ROOF SHEATHING 06/18/2018 APPROVED CMINI
TIE BEAM / LINTEL 06/07/2018 APPROVED CMINI
MONOLITHIC SLAB 04/09/2018 APPROVED CMINI
MONOLITHIC SLAB 04/05/2018 Disapproved -FEE REQUIRED CMINI
Note: not ready for inspection
FOUND SURVEY APPROVED (OFFICE) 03/21/2018 APPROVED DREWIS
PLUMBING 1ST ROUGH UNDERGROUND 03/14/2018 APPROVED JGIBSON
FOOTER 02/06/2018 APPROVED - AS NOTED WMILLER
Note: NEED TEMP TOILET BY NEXT INSPECTION TEMP TOILET 26. SANITARY FACILITIES REQUIRED B3305.1 SHALL BE PROVIDED DURING CONSTRUCTION

Review History

Department Status Date In Date Out
SW1 COMPLETE 11/21/2018 11/27/2018
Note: Released By: DREWIS
ZON COMPLETE 11/07/2018 11/07/2018
Note: Released By: AMOBLEY
ENGIN1 COMPLETE 11/07/2018 11/07/2018
Note: Released By: TBAKER
UTL COMPLETE 11/07/2018 11/08/2018
Note: Released By: LFITZGERALD Gravity Sewer new homes This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. The NFPA Clear Zone distance there can be no obstacles in front of the Hydrant and 7.5’ on the sides or 4’ behind
SW1 COMPLETE 11/07/2018 11/11/2018
Note: Released By: DREWIS
MECH COMPLETE 08/31/2018 09/07/2018
Note: Released By: JHINDMAN
MECH HOLD 08/28/2018 08/29/2018
Note: Held By: JHINDMAN 1. Page one and the EPL card are missing signatures. 6th ed. FBC R405. J. Hindman 986-3784.
SW1 COMPLETE 03/20/2018 03/21/2018
Note: Released By: DREWIS foundation s
MECH COMPLETE 11/07/2017 11/07/2017
Note: Released By: FREODICA
MECH HOLD 10/30/2017 11/06/2017
Note: Held By: FREODICA The number of bedrooms shown on floor plan and on energy calculation do not match. Coordinate as previously requested per FBC 5th ed. 107.2.1. F.Reodica -386-986-4734.
BLD COMPLETE 10/30/2017 11/06/2017
Note: Released By: FREODICA
MECH HOLD 10/13/2017 10/13/2017
Note: Held By: FREODICA Submitted correction for energy calculation dated 10-10 -17 shows the following discripancies: 1. Number of bedrooms = 0, page 1 of 5 = 4, page 2 of 5 = 3, floor plan 2. Capacity of cooling systems and efficiency = 42.2 kbtu/hr, 15 SEER ( item 12 page 1 of 5, and at EPL display card)) = 46 kbtu/hr, 14 SEER ( Cooling Equipment Summary) Coordinate and re-submit correction for clarity per FBC 5th ed. 107.2.1. F.Reodica -386-986-4734.
BLD COMPLETE 10/10/2017 10/19/2017
Note: Released By: RLEE
SW1 COMPLETE 10/06/2017 10/09/2017
Note: Released By: DREWIS
MECH HOLD 10/06/2017 10/13/2017
Note: Submitted correction for energy calculation shows the following discrepancies: 1. Number of bedrooms = 0, page 1 of 5 = 4 , page 2 of 5 = 3, on floor plan 2. Cooling system capacity and efficiency: = 42.2. kbtu/hr, 15 SEER (
BLD HOLD 10/06/2017 10/06/2017
Note: Held By: JHINDMAN Provide manufacturer's specifications and installation instructions of spray foam insulation per FBCR 5th ed. R316.2nd request J. Hindman 986-3784.
URB COMPLETE 10/06/2017 10/10/2017
Note: Released By: JBEAUDET
URB HOLD 09/20/2017 09/26/2017
Note: Held By: JBEAUDET Plan is not Legible
BLD HOLD 09/20/2017 09/25/2017
Note: Held By: FREODICA Provide manufacturer's specifications and installation instructions of spray foam insulation per FBCR 5th ed. R316. F. Reodica -386-986-4734.
ELEC COMPLETE 09/20/2017 09/20/2017
Note: Released By: JHINDMAN
ENGIN1 COMPLETE 09/20/2017 09/21/2017
Note: Released By: TBAKER
MECH HOLD 09/20/2017 09/25/2017
Note: Held By: FREODICA 1. Ptovide signature of owner/agent on energy calculation, and address, date of new home on energy performance level (EPL) display card per FBCEC 5th ed. R401.3?107.2.1. 2. Coodinate ceiling height of living room and family room on heating/cooling load calculation with floor plan per FBC 5th ed .107.2.1. F.Reodica -386-986-4734.
PLUM COMPLETE 09/20/2017 09/25/2017
Note: Released By: FREODICA
SW1 HOLD 09/20/2017 09/20/2017
Note: Held By: JHINDMAN 1. Provide a proposed drainage plan that includes. The elevations on all adjacent properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. The elevations at 20 foot intervals along all property lines. The interior elevations at no greater than a 20 foot grid. per ULDC Technical manual ch.5. 2. Provide a grade with a 6" fall 10 foot away from the foundation of the house. 5th ed. FBC R403.1. J. Hindman 986-3784.
UD1 COMPLETE 09/20/2017 09/22/2017
Note: Released By: MBACON This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
ZON COMPLETE 09/20/2017 09/20/2017
Note: Released By: AMOBLEY

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 11/29/2018
REINSPECTION FEE ¤40.00 11/27/2018
REVISION ¤40.00 11/27/2018
REINSPECTION FEE ¤40.00 08/28/2018
REINSPECTION FEE ¤40.00 08/28/2018
REINSPECTION FEE ¤40.00 04/06/2018
SITE PLAN 20 ¤20.00 11/07/2017
SURCHARGE FS 533.721 ¤17.07 11/07/2017
SURCHARGE - FS 468.631 ¤25.60 11/07/2017
STORM WATER PERMIT FEES ¤80.00 11/07/2017
3% TRANS IMPACT FEE CREDIT (¤93.74) 11/07/2017
ADMIN FEE ¤20.00 11/07/2017
ELECTRIC FEE ¤272.40 11/07/2017
3% FIRE IMPACT FEE CREDIT (¤6.56) 11/07/2017
IMPACT FEE FIRE NONRESIDENTIAL ¤218.79 11/07/2017
IMPACT FEE PARKS ¤849.24 11/07/2017
IMPACT FEE SCHOOL ¤3,600.00 11/07/2017
IMPACT FEE TRANSPORTATION ¤3,124.67 11/07/2017
MECHANICAL FEE ¤272.40 11/07/2017
3% PARKS IMPACT FEE CREDIT (¤25.48) 11/07/2017
PLAN CHECK FEE ¤141.60 11/07/2017
PLUMBING FEE ¤272.40 11/07/2017
NEW RESIDENTIAL INSPECTIONS ¤708.00 11/07/2017
Fees Total Due: ¤0.00 Total Paid: ¤9,736.39