I want to search for...
Permit #2017090492
Permit Details
Status: COED
| Parcel Id: 33-11-31-3061-00020-0050 |
| CONDITIONED SPACE: 2445 sqft |
| GARAGE: 686 sqft |
| OPENED PORCH (WITH ROOF) : 324 sqft |
| OPENED PORCH (WITH ROOF) : 42 sqft |
| Total Square Footage: 3497 sqft |
| Block: 00020 |
| Subdivision: 2108 - Hidden Lakes- Phase II-Toscana |
| Job Phone: 863-420-2100 |
| Location Address: 18 NEW WATER OAK DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 11/16/2017 |
| NOC: RECORDED |
| Applicant name: YUVAL BOTANSKY |
| Owner: APPLIED BUILDING DEVELOPMENT OF ORLANDO - PC INC |
|
Address 131 CHADWICK DRIVE DAVENPORT, FL 33837 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
APPLIED BUILDING DEVELOPMENT COMPANY - OAKHILLS IN
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
131 CHADWICK DRIVE DAVENPORT, FL 33837 |
CRC1330762 (Exp: 08/31/2026) | 863-420-2100 | 386-517-6865 |
Sub Contractors
TERRY HILE BURD
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO Box 180308 CASSELBERRY, FL 32707 |
CAC1814423 (Exp: 08/31/2024) | (407) 831-3600 | (407)831-2893 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
SANTOS L HERNANDEZ
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
946 SHADDICK DRIVE ORANGE CITY, FL 32763 |
CCC1328011 (Exp: 08/31/2026) | 386-218-4942 | 386-218-4937 |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| CANCEL |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2022) | 877-906-1113 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 12/11/2018 | FINAL APPROVED | WMILLER |
| Note: FINAL APPROVED | |||
| BLD - BUILDING FINAL | 12/10/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: could check the following (house locked 1. FIREBLOCKING R302.11 (4) PIPES, DUCTS, CABLES, AND WIRES AT CEILING AND FLOOR LEVEL (WITH APPROVED MATERIAL)GARAGE WALLS 2. HOLES IN WALLS OR CEILINGS MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 3- R402.4.1 GARAGE WALLS | |||
| BLD - BUILDING FINAL | 12/04/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 1. ADDRESS NUMBERS, SITE ADDRESS NUMBERS FBC R319.1 2. VENT STACKS/PIPES FBC, R, P3103.1 MUST TERMINATE NOT LESS THAN 6 INCHES ABOVE THE ROOF 3. TEST CAPS ON FUTURE DWV…. P3005.1.5 4. FIREBLOCKING R302.11 (4) PIPES, DUCTS, CABLES, AND WIRES AT CEILING AND FLOOR LEVEL (WITH APPROVED MATERIAL)GARAGE WALLS 5. HOLES IN WALLS OR CEILINGS MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 GARAGE WALLS | |||
| U-CROSS CONNECTION | 11/15/2018 | APPROVED | LFITZGERALD |
| ROW - FINAL APRON (AFTER POUR) | 11/15/2018 | APPROVED | KHOWELL |
| ROW - FINAL INSPECTION | 11/15/2018 | FINAL APPROVED | KHOWELL |
| U -UTILITY RESIDENTIAL FINAL | 11/15/2018 | FINAL APPROVED | LFITZGERALD |
| FINAL SURVEY (OFFICE USE ONLY) | 11/08/2018 | APPROVED | DREWIS |
| TUB SET | 10/12/2018 | APPROVED | JGIBSON |
| ROW- PRE-APRON (PRE-POUR) | 09/25/2018 | APPROVED | KHOWELL |
| ROW- PRE-APRON (PRE-POUR) | 09/20/2018 | PARTIALLY APPROVED | KHOWELL |
| Note: APRON AND SIDEWALK ONLY PAVER DRIVEWAY | |||
| ELECTRIC - EARLY POWER | 08/29/2018 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO DELL FPL RELEASED EARLY POWER 11:15 | |||
| GRAVITY SEWER TEST | 08/06/2018 | APPROVED | JGIBSON |
| U - SEWER TIE IN | 08/06/2018 | APPROVED | LFITZGERALD |
| LATH/BRICK/ WATER BARRIER | 07/17/2018 | APPROVED | CMINI |
| INSULATION | 07/03/2018 | APPROVED | DROCKWELL |
| ALL ROUGH | 06/28/2018 | APPROVED | WMILLER |
| ALL ROUGH | 06/25/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 1. ELECTRIC FOR OPTIONAL SUMMER KITCHEN WAS PLACED HOWEVER ELECTRIC NEED TO USE UNDERGROUND WIRE.... INSTALLATIONS... FBC 3803,10 WET LOCATIONS, UNDERGROUND CONDUCTORS MUST LISTED FOR USE IN WET LOCATIONS 2. 10ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) 3. wire from rear of refrigeration needs terminated and shown on plan for use | |||
| ALL ROUGH | 06/20/2018 | Disapproved -FEE REQUIRED | CMINI |
| Note: 1. PLUMBING FOR OPTIONAL SUMMER KITCHEN WAS PLACED HOWEVER ELECTRIC WAS NOT PLACED. (WAS THE ELECTRIC OVERLOOKED OR OMITTED, NEED EXPLANATION) 2. 10ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) 3. wire from rear of refrigeration needs terminated and shown on plan for use. | |||
| ALL ROUGH | 06/13/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 1. PLUMBING FOR OPTIONAL SUMMER KITCHEN WAS PLACED HOWEVER ELECTRIC WAS NOT PLACED. (WAS THE ELECTRIC OVERLOOKED OR OMITTED, NEED EXPLANATION) 2. ALL METAL BOXES SHALL BE GROUNDED R,E 3905.2 AND NEC.314.4 (LOOSE GROUND LUG AT CARRIAGE LIGHT AT RIGHT SODE OF GARAGE) 3. NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE. (BACK SIDE OF HOT WATER SUPPLY TOP PLATE BEDROOM 4 BATH SINK). 4. 10ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) 5. MISSING ELECTRIC FEED TO KITCHEN ISLAND 6. NEED TO SEAL EXHAUST BATH DUCT AT ROOF WITH MASTIC..FBC.. M1601.4.1 26. (BATHS AT BEDROOMS 3 AND 4 | |||
| ROOF VALLEY & METAL | 06/08/2018 | APPROVED | CMINI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/24/2018 | APPROVED - AS NOTED | CMINI |
| Note: need letter for mono truss bearing point | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/23/2018 | Disapproved -FEE REQUIRED | CMINI |
| Note: copala needs to expose all tie downs and complete per plan. expose front entry header. double mono truss needs to be bearing per code, missing strap on bo2. missing strap at rear lvl truss. check all. incomplete inspection | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/21/2018 | CANCELLED BY APPLICANT | WEB |
| ELECTRIC-TUG | 05/16/2018 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO SUSAN FPL RELEASED TUG POWER 11:15 | |||
| ELECTRIC-TUG | 05/09/2018 | Disapproved -FEE REQUIRED | RMARTIN |
| Note: SERVICE IS NOT GROUNDED NEC 250.24 | |||
| ROOF SHEATHING | 05/07/2018 | APPROVED | CMINI |
| TIE BEAM / LINTEL | 04/27/2018 | APPROVED | CMINI |
| FOUND SURVEY APPROVED (OFFICE) | 04/26/2018 | APPROVED | DREWIS |
| MONOLITHIC SLAB | 03/28/2018 | APPROVED | CMINI |
| MONOLITHIC SLAB | 03/23/2018 | CANCELLED BY APPLICANT | CMINI |
| PLUMBING 1ST ROUGH UNDERGROUND | 03/08/2018 | APPROVED | JGIBSON |
| FOOTER | 02/13/2018 | APPROVED | CMINI |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 11/05/2018 | 11/08/2018 |
| Note: Released By: DREWIS | |||
| BLD | COMPLETE | 06/05/2018 | 06/12/2018 |
| Note: Released By: JHINDMAN | |||
| SW1 | COMPLETE | 04/25/2018 | 04/26/2018 |
| Note: Released By: DREWIS foundations | |||
| SW1 | COMPLETE | 11/14/2017 | 11/16/2017 |
| Note: Released By: DREWIS | |||
| ZON | COMPLETE | 11/14/2017 | 11/15/2017 |
| Note: Released By: AMOBLEY | |||
| SW1 | HOLD | 10/23/2017 | 10/24/2017 |
| Note: Held By: DREWIS Proposed grade of 23.8(at foundation wall) to 23.5'(10' away from foundation wall) in front area of home does not meet FBC R401.3 requirements. D. Rewis 986-4736 | |||
| BLD | COMPLETE | 10/12/2017 | 10/13/2017 |
| Note: Released By: FREODICA | |||
| ZON | COMPLETE | 10/12/2017 | 10/13/2017 |
| Note: Released By: TAWILLIAMS | |||
| SW1 | HOLD | 10/12/2017 | 10/17/2017 |
| Note: Held By: DREWIS Proposed measurment at front of home does not meet FBC R401.3 requirments. In addition please provide additional proposed measurements for the sides of home for grade at the foundation wall and 10' away, FBC R401.3. D. Rewis 986-4736 | |||
| URB | COMPLETE | 10/12/2017 | 10/13/2017 |
| Note: Released By: JBEAUDET | |||
| ZON | HOLD | 10/06/2017 | 10/06/2017 |
| Note: Held By: TAWILLIAMS Repeat comment Please provide a landscape plan | |||
| MECH | COMPLETE | 10/06/2017 | 10/13/2017 |
| Note: Released By: FREODICA | |||
| BLD | HOLD | 10/06/2017 | 10/06/2017 |
| Note: Held By: JHINDMAN Provide manufacturer's specifications and installation instructions of spray foam insulation per FBCR 5th ed. R316. 2nd request. J. Hindman 986-3784 | |||
| URB | HOLD | 10/06/2017 | 10/10/2017 |
| Note: Held By: JBEAUDET Need to submit a landscape plan. | |||
| SW1 | HOLD | 10/06/2017 | 10/09/2017 |
| Note: Held By: DREWIS Site plan not included in attachments D. Rewis 986-4736 | |||
| URB | HOLD | 09/20/2017 | 09/26/2017 |
| Note: Held By: JBEAUDET Need to submit a Landscape plan | |||
| BLD | HOLD | 09/20/2017 | 09/25/2017 |
| Note: Held By: FREODICA Provide manufacturer's specifications and installation instructions of spray foam insulation per FBCR 5th ed. R316. F. Reodica -386-986-4734. | |||
| ELEC | COMPLETE | 09/20/2017 | 09/20/2017 |
| Note: Released By: JHINDMAN | |||
| ENGIN1 | COMPLETE | 09/20/2017 | 09/21/2017 |
| Note: Released By: TBAKER | |||
| MECH | HOLD | 09/20/2017 | 09/25/2017 |
| Note: Held By: FREODICA 1. Ptovide signature of owner/agent on energy calculation, and address, date of new home on energy performance level (EPL) display card per FBCEC 5th ed. R401.3?107.2.1. | |||
| PLUM | COMPLETE | 09/20/2017 | 09/25/2017 |
| Note: Released By: FREODICA | |||
| SW1 | HOLD | 09/20/2017 | 09/20/2017 |
| Note: Held By: JHINDMAN 1. Provide a proposed drainage plan that includes. The elevations on all adjacent properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. The elevations at 20 foot intervals along all property lines. The interior elevations at no greater than a 20 foot grid. per ULDC Technical manual ch.5. 2. Provide a grade with a 6" fall 10 foot away from the foundation of the house. 5th ed. FBC R403.1. J. Hindman 986-3784. | |||
| UD1 | COMPLETE | 09/20/2017 | 09/22/2017 |
| Note: Released By: MBACON This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. | |||
| ZON | HOLD | 09/20/2017 | 09/20/2017 |
| Note: Held By: AMOBLEY Please provide a landscape plan |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 12/11/2018 |
| REINSPECTION FEE | ¤40.00 | 12/11/2018 |
| REINSPECTION FEE | ¤40.00 | 06/25/2018 |
| REINSPECTION FEE | ¤40.00 | 06/25/2018 |
| REINSPECTION FEE | ¤40.00 | 06/25/2018 |
| REINSPECTION FEE | ¤40.00 | 06/25/2018 |
| REINSPECTION FEE | ¤40.00 | 06/25/2018 |
| REVISION | ¤40.00 | 06/25/2018 |
| SITE PLAN 20 | ¤20.00 | 11/16/2017 |
| SURCHARGE FS 533.721 | ¤15.39 | 11/16/2017 |
| SURCHARGE - FS 468.631 | ¤23.08 | 11/16/2017 |
| STORM WATER PERMIT FEES | ¤80.00 | 11/16/2017 |
| 3% TRANS IMPACT FEE CREDIT | (¤93.74) | 11/16/2017 |
| ADMIN FEE | ¤20.00 | 11/16/2017 |
| ELECTRIC FEE | ¤248.40 | 11/16/2017 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.56) | 11/16/2017 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤218.79 | 11/16/2017 |
| IMPACT FEE PARKS | ¤849.24 | 11/16/2017 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 11/16/2017 |
| IMPACT FEE TRANSPORTATION | ¤3,124.67 | 11/16/2017 |
| MECHANICAL FEE | ¤248.40 | 11/16/2017 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 11/16/2017 |
| PLAN CHECK FEE | ¤125.60 | 11/16/2017 |
| PLUMBING FEE | ¤248.40 | 11/16/2017 |
| NEW RESIDENTIAL INSPECTIONS | ¤628.00 | 11/16/2017 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,644.19 |