I want to search for...

Permit #2017090492

Permit Details

Status: COED

Parcel Id: 33-11-31-3061-00020-0050
CONDITIONED SPACE: 2445 sqft
GARAGE: 686 sqft
OPENED PORCH (WITH ROOF) : 324 sqft
OPENED PORCH (WITH ROOF) : 42 sqft
Total Square Footage: 3497 sqft
Block: 00020
Subdivision: 2108 - Hidden Lakes- Phase II-Toscana
Job Phone: 863-420-2100
Location Address: 18 NEW WATER OAK DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/16/2017
NOC: RECORDED
Applicant name: YUVAL BOTANSKY
Owner: APPLIED BUILDING DEVELOPMENT OF ORLANDO - PC INC

Address

131 CHADWICK DRIVE

DAVENPORT, FL 33837

Lot: 0050
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

APPLIED BUILDING DEVELOPMENT COMPANY - OAKHILLS IN
Status Location Address State License Number Phone Fax
ACTIVE

131 CHADWICK DRIVE

DAVENPORT, FL 33837

CRC1330762 (Exp: 08/31/2026) 863-420-2100 386-517-6865

Sub Contractors

TERRY HILE BURD
Status Location Address State License Number Phone Fax
INACTIVE

PO Box 180308

CASSELBERRY, FL 32707

CAC1814423 (Exp: 08/31/2024) (407) 831-3600 (407)831-2893
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937
JOSEPH H STRADA JR
Status Location Address State License Number Phone
CANCEL

3400 ST JOHNS PKWY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2022) 877-906-1113

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/11/2018 FINAL APPROVED WMILLER
Note: FINAL APPROVED
BLD - BUILDING FINAL 12/10/2018 Disapproved -FEE REQUIRED WMILLER
Note: could check the following (house locked 1. FIREBLOCKING R302.11 (4) PIPES, DUCTS, CABLES, AND WIRES AT CEILING AND FLOOR LEVEL (WITH APPROVED MATERIAL)GARAGE WALLS 2. HOLES IN WALLS OR CEILINGS MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 3- R402.4.1 GARAGE WALLS
BLD - BUILDING FINAL 12/04/2018 Disapproved -FEE REQUIRED WMILLER
Note: 1. ADDRESS NUMBERS, SITE ADDRESS NUMBERS FBC R319.1 2. VENT STACKS/PIPES FBC, R, P3103.1 MUST TERMINATE NOT LESS THAN 6 INCHES ABOVE THE ROOF 3. TEST CAPS ON FUTURE DWV…. P3005.1.5 4. FIREBLOCKING R302.11 (4) PIPES, DUCTS, CABLES, AND WIRES AT CEILING AND FLOOR LEVEL (WITH APPROVED MATERIAL)GARAGE WALLS 5. HOLES IN WALLS OR CEILINGS MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 GARAGE WALLS
U-CROSS CONNECTION 11/15/2018 APPROVED LFITZGERALD
ROW - FINAL APRON (AFTER POUR) 11/15/2018 APPROVED KHOWELL
ROW - FINAL INSPECTION 11/15/2018 FINAL APPROVED KHOWELL
U -UTILITY RESIDENTIAL FINAL 11/15/2018 FINAL APPROVED LFITZGERALD
FINAL SURVEY (OFFICE USE ONLY) 11/08/2018 APPROVED DREWIS
TUB SET 10/12/2018 APPROVED JGIBSON
ROW- PRE-APRON (PRE-POUR) 09/25/2018 APPROVED KHOWELL
ROW- PRE-APRON (PRE-POUR) 09/20/2018 PARTIALLY APPROVED KHOWELL
Note: APRON AND SIDEWALK ONLY PAVER DRIVEWAY
ELECTRIC - EARLY POWER 08/29/2018 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED EARLY POWER 11:15
GRAVITY SEWER TEST 08/06/2018 APPROVED JGIBSON
U - SEWER TIE IN 08/06/2018 APPROVED LFITZGERALD
LATH/BRICK/ WATER BARRIER 07/17/2018 APPROVED CMINI
INSULATION 07/03/2018 APPROVED DROCKWELL
ALL ROUGH 06/28/2018 APPROVED WMILLER
ALL ROUGH 06/25/2018 Disapproved -FEE REQUIRED WMILLER
Note: 1. ELECTRIC FOR OPTIONAL SUMMER KITCHEN WAS PLACED HOWEVER ELECTRIC NEED TO USE UNDERGROUND WIRE.... INSTALLATIONS... FBC 3803,10 WET LOCATIONS, UNDERGROUND CONDUCTORS MUST LISTED FOR USE IN WET LOCATIONS 2. 10ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) 3. wire from rear of refrigeration needs terminated and shown on plan for use
ALL ROUGH 06/20/2018 Disapproved -FEE REQUIRED CMINI
Note: 1. PLUMBING FOR OPTIONAL SUMMER KITCHEN WAS PLACED HOWEVER ELECTRIC WAS NOT PLACED. (WAS THE ELECTRIC OVERLOOKED OR OMITTED, NEED EXPLANATION) 2. 10ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) 3. wire from rear of refrigeration needs terminated and shown on plan for use.
ALL ROUGH 06/13/2018 Disapproved -FEE REQUIRED WMILLER
Note: 1. PLUMBING FOR OPTIONAL SUMMER KITCHEN WAS PLACED HOWEVER ELECTRIC WAS NOT PLACED. (WAS THE ELECTRIC OVERLOOKED OR OMITTED, NEED EXPLANATION) 2. ALL METAL BOXES SHALL BE GROUNDED R,E 3905.2 AND NEC.314.4 (LOOSE GROUND LUG AT CARRIAGE LIGHT AT RIGHT SODE OF GARAGE) 3. NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE. (BACK SIDE OF HOT WATER SUPPLY TOP PLATE BEDROOM 4 BATH SINK). 4. 10ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) 5. MISSING ELECTRIC FEED TO KITCHEN ISLAND 6. NEED TO SEAL EXHAUST BATH DUCT AT ROOF WITH MASTIC..FBC.. M1601.4.1 26. (BATHS AT BEDROOMS 3 AND 4
ROOF VALLEY & METAL 06/08/2018 APPROVED CMINI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/24/2018 APPROVED - AS NOTED CMINI
Note: need letter for mono truss bearing point
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/23/2018 Disapproved -FEE REQUIRED CMINI
Note: copala needs to expose all tie downs and complete per plan. expose front entry header. double mono truss needs to be bearing per code, missing strap on bo2. missing strap at rear lvl truss. check all. incomplete inspection
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/21/2018 CANCELLED BY APPLICANT WEB
ELECTRIC-TUG 05/16/2018 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED TUG POWER 11:15
ELECTRIC-TUG 05/09/2018 Disapproved -FEE REQUIRED RMARTIN
Note: SERVICE IS NOT GROUNDED NEC 250.24
ROOF SHEATHING 05/07/2018 APPROVED CMINI
TIE BEAM / LINTEL 04/27/2018 APPROVED CMINI
FOUND SURVEY APPROVED (OFFICE) 04/26/2018 APPROVED DREWIS
MONOLITHIC SLAB 03/28/2018 APPROVED CMINI
MONOLITHIC SLAB 03/23/2018 CANCELLED BY APPLICANT CMINI
PLUMBING 1ST ROUGH UNDERGROUND 03/08/2018 APPROVED JGIBSON
FOOTER 02/13/2018 APPROVED CMINI

Review History

Department Status Date In Date Out
SW1 COMPLETE 11/05/2018 11/08/2018
Note: Released By: DREWIS
BLD COMPLETE 06/05/2018 06/12/2018
Note: Released By: JHINDMAN
SW1 COMPLETE 04/25/2018 04/26/2018
Note: Released By: DREWIS foundations
SW1 COMPLETE 11/14/2017 11/16/2017
Note: Released By: DREWIS
ZON COMPLETE 11/14/2017 11/15/2017
Note: Released By: AMOBLEY
SW1 HOLD 10/23/2017 10/24/2017
Note: Held By: DREWIS Proposed grade of 23.8(at foundation wall) to 23.5'(10' away from foundation wall) in front area of home does not meet FBC R401.3 requirements. D. Rewis 986-4736
BLD COMPLETE 10/12/2017 10/13/2017
Note: Released By: FREODICA
ZON COMPLETE 10/12/2017 10/13/2017
Note: Released By: TAWILLIAMS
SW1 HOLD 10/12/2017 10/17/2017
Note: Held By: DREWIS Proposed measurment at front of home does not meet FBC R401.3 requirments. In addition please provide additional proposed measurements for the sides of home for grade at the foundation wall and 10' away, FBC R401.3. D. Rewis 986-4736
URB COMPLETE 10/12/2017 10/13/2017
Note: Released By: JBEAUDET
ZON HOLD 10/06/2017 10/06/2017
Note: Held By: TAWILLIAMS Repeat comment Please provide a landscape plan
MECH COMPLETE 10/06/2017 10/13/2017
Note: Released By: FREODICA
BLD HOLD 10/06/2017 10/06/2017
Note: Held By: JHINDMAN Provide manufacturer's specifications and installation instructions of spray foam insulation per FBCR 5th ed. R316. 2nd request. J. Hindman 986-3784
URB HOLD 10/06/2017 10/10/2017
Note: Held By: JBEAUDET Need to submit a landscape plan.
SW1 HOLD 10/06/2017 10/09/2017
Note: Held By: DREWIS Site plan not included in attachments D. Rewis 986-4736
URB HOLD 09/20/2017 09/26/2017
Note: Held By: JBEAUDET Need to submit a Landscape plan
BLD HOLD 09/20/2017 09/25/2017
Note: Held By: FREODICA Provide manufacturer's specifications and installation instructions of spray foam insulation per FBCR 5th ed. R316. F. Reodica -386-986-4734.
ELEC COMPLETE 09/20/2017 09/20/2017
Note: Released By: JHINDMAN
ENGIN1 COMPLETE 09/20/2017 09/21/2017
Note: Released By: TBAKER
MECH HOLD 09/20/2017 09/25/2017
Note: Held By: FREODICA 1. Ptovide signature of owner/agent on energy calculation, and address, date of new home on energy performance level (EPL) display card per FBCEC 5th ed. R401.3?107.2.1.
PLUM COMPLETE 09/20/2017 09/25/2017
Note: Released By: FREODICA
SW1 HOLD 09/20/2017 09/20/2017
Note: Held By: JHINDMAN 1. Provide a proposed drainage plan that includes. The elevations on all adjacent properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. The elevations at 20 foot intervals along all property lines. The interior elevations at no greater than a 20 foot grid. per ULDC Technical manual ch.5. 2. Provide a grade with a 6" fall 10 foot away from the foundation of the house. 5th ed. FBC R403.1. J. Hindman 986-3784.
UD1 COMPLETE 09/20/2017 09/22/2017
Note: Released By: MBACON This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
ZON HOLD 09/20/2017 09/20/2017
Note: Held By: AMOBLEY Please provide a landscape plan

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 12/11/2018
REINSPECTION FEE ¤40.00 12/11/2018
REINSPECTION FEE ¤40.00 06/25/2018
REINSPECTION FEE ¤40.00 06/25/2018
REINSPECTION FEE ¤40.00 06/25/2018
REINSPECTION FEE ¤40.00 06/25/2018
REINSPECTION FEE ¤40.00 06/25/2018
REVISION ¤40.00 06/25/2018
SITE PLAN 20 ¤20.00 11/16/2017
SURCHARGE FS 533.721 ¤15.39 11/16/2017
SURCHARGE - FS 468.631 ¤23.08 11/16/2017
STORM WATER PERMIT FEES ¤80.00 11/16/2017
3% TRANS IMPACT FEE CREDIT (¤93.74) 11/16/2017
ADMIN FEE ¤20.00 11/16/2017
ELECTRIC FEE ¤248.40 11/16/2017
3% FIRE IMPACT FEE CREDIT (¤6.56) 11/16/2017
IMPACT FEE FIRE NONRESIDENTIAL ¤218.79 11/16/2017
IMPACT FEE PARKS ¤849.24 11/16/2017
IMPACT FEE SCHOOL ¤3,600.00 11/16/2017
IMPACT FEE TRANSPORTATION ¤3,124.67 11/16/2017
MECHANICAL FEE ¤248.40 11/16/2017
3% PARKS IMPACT FEE CREDIT (¤25.48) 11/16/2017
PLAN CHECK FEE ¤125.60 11/16/2017
PLUMBING FEE ¤248.40 11/16/2017
NEW RESIDENTIAL INSPECTIONS ¤628.00 11/16/2017
Fees Total Due: ¤0.00 Total Paid: ¤9,644.19