I want to search for...

Permit #2017100116

Permit Details

Status: COED

Block: 00080
Subdivision: 2121 - Pinnacles Professional Park
Job Phone: 386-503-0906
Location Address: 84 PINNACLES DR
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 11/13/2017
NOC: RECORDED
Applicant name: ANTHONY FALLONE
Owner: BELLANDONI LLC

Address

84 PINNACLES DR

PALM COAST, FL 32164

Address

SUITE 200

PALM COAST, FL 32164

Lot: 0010
Contracted Stated Job Value: ¤14,000.00
Job Description: UNIT 400- INSTALLING BATHROOM
Type: CN

Contractor

FONTANA CONSTRUCTION, INC.
Status Location Address State License Number Phone Fax
CANCEL

P.O. BOX 351222

PALM COAST, FL 32137

CBC1250596 (Exp: 08/31/2022) 386-503-0906 (386)986-1305

Sub Contractors

JOHN CHARLES GRAY
Status Location Address State License Number Phone Fax
ACTIVE

2707 ANNETTE STREET

FLAGLER BEACH, FL 32136

CFC1425975 (Exp: 08/31/2026) (386)793-3690 (386)439-7585
JESSE E MORRIS
Status Location Address State License Number Phone
INACTIVE

60 COPPER LANE

PALM COAST, FL 32137

EC13007529 (Exp: 08/31/2018) 847-815-2885

Inspection History

Type Request Date Result Inspector
PLUMBING FINAL 09/26/2018 APPROVED JGIBSON
ELECTRIC FINAL 09/26/2018 APPROVED RMARTIN
BUILDING FINAL 09/26/2018 FINAL APPROVED CMINI
ELECTRIC FINAL 08/06/2018 PARTIALLY APPROVED RMARTIN
Note: THERE WAS ONLY FINAL ADDED TO PERMIT, LOOKED AT WALLS/ROUGH, NEED REVISION ON OUTLETS ADDED UP HIGH BY FINAL
FRAMING 08/06/2018 APPROVED - AS NOTED DROCKWELL
Note: Exam room framing 3 units
PLUMBING FINAL 04/13/2018 Disapproved -FEE REQUIRED JHINDMAN
Note: THIS IS A REINSPECTION Revise plans to show added plumbing and mechanical at washer/dryer. 6th ed. FBC 107.4
BUILDING FINAL 04/13/2018 Disapproved - NO FEE JHINDMAN
Note: Revise plans to show added plumbing and mechanical at washer/dryer. 6th ed. FBC 107.4
FIRE FINAL 04/13/2018 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
U - UTILITY COMMERCIAL FINAL 03/01/2018 FINAL APPROVED MBACON
FIRE FINAL 03/01/2018 Disapproved -FEE REQUIRED JHINDMAN
Note: 1. rear fire extinguisher needs to be mounted nfpa10. 2, restroom missing fire sprinkler head nfpa 13
PLUMBING FINAL 03/01/2018 Disapproved -FEE REQUIRED JGIBSON
Note: MISSING AUTO VENT AT SINK IN BREAK ROOM CONCEAL ALL PLUMBING PIPES ON WALL SERVING SINK THAT'S MISSING AUTO VENT
ELECTRIC FINAL 03/01/2018 APPROVED RMARTIN
Note: THIS IS A REINSPECTION
ABOVE CEILING 03/01/2018 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
ABOVE CEILING 01/22/2018 Disapproved -FEE REQUIRED JHINDMAN
Note: THIS IS A REINSPECTION ceiling is covered up cannot inspect. 5th ed. FBC 110.1
FIRE FINAL 01/22/2018 Disapproved -FEE REQUIRED JHINDMAN
Note: rear fire extinguisher needs to be mounted nfpa10.
FLOOR/WALL PENETRATION 12/18/2017 APPROVED JHINDMAN
ABOVE CEILING 12/18/2017 Disapproved - NO FEE JHINDMAN
Note: not ready
ELECTRIC FINAL 12/18/2017 Disapproved - NO FEE RMARTIN
Note: NEED TO HAVE LAY-IN LIGHTS IN CORRECT LOCATION AND SUPPORTED PER NEC 410.36B AND MC NEEDS STRAPPING IN THIS AREA ALSO PER NEC 330.30 B AND C
MONOLITHIC SLAB 11/30/2017 APPROVED CMINI
FRAMING 11/29/2017 APPROVED CMINI
Note: THIS IS A REINSPECTION
FRAMING 11/28/2017 Disapproved -FEE REQUIRED CMINI
Note: no access to unit, doors locked
ELECTRIC 2ND ROUGH 11/22/2017 APPROVED - AS NOTED RMARTIN
Note: ANY CHANGE IN PLAN NEEDS TO BE REVISED BY FINAL
PLUMBING 1ST ROUGH 11/22/2017 APPROVED JGIBSON
PLUMBING 2ND ROUGH 11/22/2017 APPROVED JGIBSON

Review History

Department Status Date In Date Out
MECH COMPLETE 08/01/2018 08/03/2018
Note: Released By: FREODICA
PLUM COMPLETE 08/01/2018 08/03/2018
Note: Released By: FREODICA
BLD COMPLETE 07/18/2018 07/18/2018
Note: Released By: JHINDMAN
ELEC COMPLETE 07/03/2018 07/06/2018
Note: Released By: DREWIS
BLD HOLD 07/03/2018 07/13/2018
Note: Held By: JHINDMAN 1. The new restroom appears to be part of another unit. If it is then it must be a seperate permit for that unit. If it is part of the unit for this permit then we will need a full set of plans for reconfiguring the old and new units. J. Hindman 986-3784. As an informational note the plumbing for the washer must be resolved as it was not shown on your plans. J. Hindman 986-3784.
PLUM HOLD 07/03/2018 07/18/2018
Note: Held By: FREODICA Revision: 1. Submitted revision of new additional bathroom is loacated in adjacent area A which is not covered by the approved permit (suite 400 - area B) and shall be applied under separate permit per FBC 6th ed. 107.1. 2. Provide the sanitary riser diagram for the new washer and domeatic water (hot and cold water ) to include the restroom at the permitted area (suite 400) per FBC 6th ed. 107.3.5. F.Reodica -386-986-4734.
MECH HOLD 07/03/2018 07/18/2018
Note: Held By: FREODICA Revision: 1. Provide balanced return air from new offices per FBCM 6th ed. 601.6. 2. Provide hvac contractor per F.S. 489. F.Reodica 386-986-4734.
ELEC HOLD 06/28/2018 06/28/2018
Note: Held By: DREWIS Provide electrical specifications for the newly added washer and dryer. Daniel Rewis 986-4736
MECH HOLD 06/27/2018 06/27/2018
Note: Held By: FREODICA Revision: The revised plan shows (3) new offices at area "B" but not mentioned on revision. Clarify as these offices require mechanical ventilation and permit application shall be revised too per FBC 6th ed. 107.3.5./107.1. F.Reodica -386-986-4734.
BLD HOLD 06/15/2018 06/26/2018
Note: Held By: JHINDMAN 1. Identify the changes to the plans 6th ed. FBC 107.3.5. J. Hindman 986-3784.
PLUM HOLD 06/15/2018 06/27/2018
Note: Held By: FREODICA Revision: 1. Provide sanitary and domestic water riser diagrams (hot and cold) for the new bathroom at area "A" per FBC 6th ed. 107.3.5. F.Reodica -386-9864734..
BLD COMPLETE 10/26/2017 11/09/2017
Note: Released By: JHINDMAN
PLUM COMPLETE 10/26/2017 11/09/2017
Note: Released By: FREODICA
MECH COMPLETE 10/26/2017 11/09/2017
Note: Released By: FREODICA Not applicable.
BLD HOLD 10/04/2017 10/18/2017
Note: Held By: RLEE plans incomplete Provide plans identifying handicap accessible clear floor space and grab bars, etc for handicap accessibility.
ELEC COMPLETE 10/04/2017 10/09/2017
Note: Released By: DREWIS
FI1 COMPLETE 10/04/2017 10/19/2017
Note: Released By: WMILLER
MECH HOLD 10/04/2017 10/18/2017
Note: Held By: FREODICA Provide hvac system information on suite 300 and suite 400 due to firewall separation between those suites and if there is a change, provide hvac contarctor and hvac plans per FS 489/FBC 5th ed. 107.2.1. F.Reodica -386-986-4734.
PLUM HOLD 10/04/2017 10/18/2017
Note: Held By: FREODICA Plans incomplete. Provide plumbing risers diagrams, and layout. signed and sealed per FBC 5th ed. 107.2.5. F.Reodica -386-986-4734.
UD1 COMPLETE 10/04/2017 10/09/2017
Note: Released By: CJOHNSON
ZON COMPLETE 10/04/2017 10/04/2017
Note: Released By: JGONZALEZ

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 09/25/2018
REVISION ¤40.00 09/25/2018
REVISION ¤40.00 09/25/2018
REINSPECTION FEE ¤40.00 04/12/2018
REINSPECTION FEE ¤40.00 04/12/2018
REINSPECTION FEE ¤40.00 04/12/2018
REINSPECTION FEE ¤40.00 04/12/2018
REINSPECTION FEE ¤40.00 04/12/2018
ADMIN COMMERCIAL ¤60.00 11/13/2017
INSPECTION - COMMERCIAL ADD ¤98.00 11/13/2017
ELECTRIC FEE ¤68.40 11/13/2017
PLAN CHECK FEE ¤100.00 11/13/2017
PLUMBING FEE ¤68.40 11/13/2017
SITE PLAN 20 ¤20.00 11/13/2017
SURCHARGE FS 533.721 ¤3.17 11/13/2017
SURCHARGE - FS 468.631 ¤4.75 11/13/2017
Fees Total Due: ¤0.00 Total Paid: ¤742.72