Permit #2017100441
Permit Details
Status: COED
| Parcel Id: 16-11-31-1260-00000-0450 |
| CONDITIONED SPACE: 2745 sqft |
| GARAGE: 668 sqft |
| OPENED PORCH (WITH ROOF) : 126 sqft |
| OPENED PORCH (WITH ROOF) : 372 sqft |
| Total Square Footage: 3911 sqft |
| Block: 00000 |
| Subdivision: 2081 - Creekside Village at Grand Haven |
| Job Phone: 386-236-4133 |
| Location Address: 26 CREEKSIDE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 11/13/2017 |
| NOC: RECORDED |
| Applicant name: LEONARDO CIRO SANCLEMENTE |
| Owner: PANELLINO, CHARLES & CLARISSE |
|
Address 45 HOFSTRA DR SMITHTOWN, NY 11787 |
| Lot: 0450 |
| Contracted Stated Job Value: ¤410,634.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
INTERVEST CONSTRUCTION, INC.
| Status | Location Address | State License Number | Phone |
| CANCEL |
2379 BEVILLE RD DAYTONA BEACH, FL 32119 |
CBC1261237 (Exp: 08/31/2020) | 386-236-4133 |
Sub Contractors
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
ROBERT CRAIG KULP
| Status | Location Address | State License Number | Phone |
| CANCEL |
5401 ENERGY AIR CT ORLANDO, FL 32810 |
CAC1816317 (Exp: 08/31/2022) | 407-886-3729 |
JEFFREY DALE KNIGHT
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
923 ASHMEADE CT PORT ORANGE, FL 32127 |
CFC057351 (Exp: 08/31/2026) | 386-345-3857 | 386-345-4443 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
KEN DEPRINZIO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
325 WALKER STREET HOLLY HILL, FL 32117 |
11351 (Exp: 08/31/2026) | 386-672-8494 | 386-673-7856 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL INSPECTION | 06/04/2018 | APPROVED | RGROSS |
| BLD - BUILDING FINAL | 06/01/2018 | FINAL APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 05/31/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 1. seal around range hood and hood for future grill 2. lighting at rear door not working 3. missing hall lights 4. seal space around pipes in walls and ceilings (check all) 5. seal walls at elivated air handler 6. seal liquid lines at same location 7. lights in jack and jill bath need bulbs install outlet at master bath counter by shower | |||
| FINAL SURVEY (OFFICE USE ONLY) | 05/30/2018 | APPROVED | DREWIS |
| U -UTILITY RESIDENTIAL FINAL | 05/24/2018 | FINAL APPROVED | DSPENCER |
| ROW - FINAL APRON (AFTER POUR) | 05/24/2018 | APPROVED | RGROSS |
| ROW- PRE-APRON (PRE-POUR) | 05/14/2018 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION. READY TO POUR | |||
| PROJECT STATUS (OFFICE USE) | 05/09/2018 | APPROVED | KHOWELL |
| Note: WILLIAM WITH I.C.I. CALLED AND WANTED ME TO LOOK AT THE MIAMI CURB FOR REPAIRS | |||
| ROW- PRE-APRON (PRE-POUR) | 05/03/2018 | PARTIALLY APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION. APPROVED FOR APRON POUR ONLY. PAVER DRIVEWAY. UPPER RESTRAINTS NOT FORMED. | |||
| ROW- PRE-APRON (PRE-POUR) | 05/01/2018 | CANCELLED BY APPLICANT | KHOWELL |
| Note: WILLIAM WITH ICI CALLED TO CANCELL | |||
| ELECTRIC - EARLY POWER | 04/24/2018 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO SUSAN FPL RELEASED EARLY POWER 2:40 | |||
| LATH/BRICK/ WATER BARRIER | 03/19/2018 | APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 03/16/2018 | CANCELLED BY APPLICANT | WMILLER |
| INSULATION | 03/09/2018 | APPROVED | DROCKWELL |
| GAS ROUGH | 03/09/2018 | APPROVED | DROCKWELL |
| ALL ROUGH | 03/07/2018 | APPROVED - AS NOTED | WMILLER |
| Note: need gas riser diagram by insulation | |||
| U - SEWER TIE IN | 03/06/2018 | APPROVED | LFITZGERALD |
| Note: THIS IS A REINSPECTION | |||
| U - SEWER TIE IN | 03/02/2018 | CANCELLED BY APPLICANT | MBACON |
| ROOF VALLEY & METAL | 03/02/2018 | APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/02/2018 | APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING | 03/02/2018 | CANCELLED BY INSPECTOR | WMILLER |
| GRAVITY SEWER TEST | 03/02/2018 | APPROVED | JGIBSON |
| ROOF VALLEY & METAL | 02/28/2018 | CANCELLED BY APPLICANT | WMILLER |
| WALL SHEATHING | 02/28/2018 | APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/28/2018 | CANCELLED BY APPLICANT | WMILLER |
| WALL SHEATHING | 02/22/2018 | CANCELLED BY APPLICANT | DROCKWELL |
| ELECTRIC-TUG | 02/07/2018 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO SUSAN FPL RELEASED TUG POWER 3:45 | |||
| TIE BEAM / LINTEL | 01/30/2018 | APPROVED | CMINI |
| FOUND SURVEY APPROVED (OFFICE) | 01/29/2018 | APPROVED | DREWIS |
| MONOLITHIC SLAB | 01/16/2018 | APPROVED | DROCKWELL |
| PLUMBING 1ST ROUGH UNDERGROUND | 01/09/2018 | APPROVED - AS NOTED | JGIBSON |
| Note: REVISION FOR ''VTR'' ON MASTER VANITIES, BUT ''AAV'' ARE BEING USED |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 05/30/2018 | 05/30/2018 |
| Note: Released By: DREWIS | |||
| SW1 | HOLD | 05/24/2018 | 05/25/2018 |
| Note: Held By: DREWIS final s Provide grade elevations at the foundation in addition to 10' away from the foundation per FBC 6th ed. R401.3 Daniel Rewis 986-4736 | |||
| SW1 | COMPLETE | 01/25/2018 | 01/29/2018 |
| Note: Released By: DREWIS foundation survey | |||
| PLUM | CANCEL | 01/18/2018 | 01/23/2018 |
| Note: Revision: changed sanitary riser diagram. Owner's bathroom group vent through the roof was changed to air admittance valve. | |||
| SW1 | COMPLETE | 11/03/2017 | 11/08/2017 |
| Note: Released By: DREWIS | |||
| ELEC | COMPLETE | 11/03/2017 | 11/08/2017 |
| Note: Released By: DREWIS | |||
| PLUM | COMPLETE | 11/03/2017 | 11/08/2017 |
| Note: Released By: FREODICA | |||
| BLD | COMPLETE | 10/10/2017 | 10/19/2017 |
| Note: Released By: FREODICA | |||
| ELEC | HOLD | 10/10/2017 | 10/16/2017 |
| Note: Held By: DREWIS Provide signature and seal of designer or the signature and license number of the elctrical contractor on load calculations and plans, FBC 107.1. Provide a disconnect for the AHU, NEC 2011 440.14. D. Rewis 986-4736 | |||
| ENGIN1 | COMPLETE | 10/10/2017 | 10/12/2017 |
| Note: Released By: TBAKER | |||
| MECH | COMPLETE | 10/10/2017 | 10/19/2017 |
| Note: Released By: FREODICA | |||
| PLUM | HOLD | 10/10/2017 | 10/19/2017 |
| Note: Held By: FREODICA Held By: FREODICA Provide signature and license number of gas contractor on gas riser diagram per FBC 5th ed. 107.1. F.Reodica -386-986-4734. | |||
| SW1 | HOLD | 10/10/2017 | 10/16/2017 |
| Note: Held By: DREWIS Please provide proposed survey measurements at foundation wall and 10' away from foundation wall of residence to assure compliance with FBC R401.3. D. Rewis 986-4736 | |||
| UD1 | COMPLETE | 10/10/2017 | 10/13/2017 |
| Note: Released By: LFITZGERALD Gravity Sewer new homes This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. The NFPA Clear Zone distance there can be no obstacles in front of the Hydrant and 7.5’ on the sides or 4’ behind | |||
| ZON | COMPLETE | 10/10/2017 | 10/10/2017 |
| Note: Released By: AMOBLEY |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REVISION | ¤40.00 | 06/01/2018 |
| REINSPECTION FEE | ¤40.00 | 06/01/2018 |
| NEW RESIDENTIAL INSPECTIONS | ¤822.00 | 11/13/2017 |
| SITE PLAN 20 | ¤20.00 | 11/13/2017 |
| SURCHARGE FS 533.721 | ¤19.46 | 11/13/2017 |
| SURCHARGE - FS 468.631 | ¤29.19 | 11/13/2017 |
| STORM WATER PERMIT FEES | ¤80.00 | 11/13/2017 |
| 3% TRANS IMPACT FEE CREDIT | (¤93.74) | 11/13/2017 |
| ADMIN FEE | ¤20.00 | 11/13/2017 |
| ELECTRIC FEE | ¤306.60 | 11/13/2017 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.56) | 11/13/2017 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤218.79 | 11/13/2017 |
| IMPACT FEE PARKS | ¤849.24 | 11/13/2017 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 11/13/2017 |
| IMPACT FEE TRANSPORTATION | ¤3,124.67 | 11/13/2017 |
| MECHANICAL FEE | ¤306.60 | 11/13/2017 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 11/13/2017 |
| PLAN CHECK FEE | ¤164.40 | 11/13/2017 |
| PLUMBING FEE | ¤306.60 | 11/13/2017 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,821.77 |