I want to search for...

Permit #2017100770

Permit Details

Status: COED

Parcel Id: 33-11-31-3061-00010-0120
CONDITIONED SPACE: 2443 sqft
CONDITIONED SPACE: 269 sqft
GARAGE: 764 sqft
OPENED PORCH (WITH ROOF) : 91 sqft
OPENED PORCH (WITH ROOF) : 442 sqft
Total Square Footage: 4009 sqft
Block: 00010
Subdivision: 2108 - Hidden Lakes- Phase II-Toscana
Job Phone: 863-420-2100
Location Address: 23 NEW LEATHERWOOD DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/08/2017
NOC: RECORDED
Applicant name: YUVAL BOTANSKY
Owner: APPLIED BUILDING DEVELOPMENT OF ORLANDO - PC INC

Address

131 CHADWICK DRIVE

DAVENPORT, FL 33837

Lot: 0120
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

APPLIED BUILDING DEVELOPMENT COMPANY - OAKHILLS IN
Status Location Address State License Number Phone Fax
ACTIVE

131 CHADWICK DRIVE

DAVENPORT, FL 33837

CRC1330762 (Exp: 08/31/2026) 863-420-2100 386-517-6865

Sub Contractors

TERRY HILE BURD
Status Location Address State License Number Phone Fax
INACTIVE

PO Box 180308

CASSELBERRY, FL 32707

CAC1814423 (Exp: 08/31/2024) (407) 831-3600 (407)831-2893
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937
JOSEPH H STRADA JR
Status Location Address State License Number Phone
CANCEL

3400 ST JOHNS PKWY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2022) 877-906-1113

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 11/02/2018 FINAL APPROVED DROCKWELL
U-CROSS CONNECTION 11/02/2018 APPROVED MBACON
ROW - FINAL APRON (AFTER POUR) 11/02/2018 APPROVED KHOWELL
ROW - FINAL INSPECTION 11/02/2018 FINAL APPROVED KHOWELL
U -UTILITY RESIDENTIAL FINAL 11/02/2018 FINAL APPROVED MBACON
FINAL SURVEY (OFFICE USE ONLY) 10/31/2018 APPROVED DREWIS
Note: THIS IS A REINSPECTION
FINAL SURVEY (OFFICE USE ONLY) 10/26/2018 Disapproved - NO FEE DREWIS
Note: Property line elevations allow flow onto the adjacent properties, Tech. Manual Sec. 5 Eng. Standard 300.01 A1 c6. Daniel Rewis 986-4736
ROW- PRE-APRON (PRE-POUR) 10/17/2018 APPROVED KHOWELL
ROW- PRE-APRON (PRE-POUR) 10/15/2018 PARTIALLY APPROVED RGROSS
Note: APPROVED FOR APRON AND SIDEWALK POUR ONLY.
U - SEWER TIE IN 10/12/2018 APPROVED LFITZGERALD
GRAVITY SEWER TEST 10/12/2018 APPROVED JGIBSON
TUB SET 10/09/2018 APPROVED JGIBSON
TUB SET 10/05/2018 CANCELLED BY APPLICANT DROCKWELL
ELECTRIC - EARLY POWER 10/05/2018 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED EARLY POWER 3:17
LATH/BRICK/ WATER BARRIER 08/29/2018 APPROVED WMILLER
Note: approved
INSULATION 08/15/2018 APPROVED WMILLER
Note: insulation approved
INSULATION 08/14/2018 Disapproved -FEE REQUIRED WMILLER
Note: DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL
ALL ROUGH 08/10/2018 APPROVED CMINI
ALL ROUGH 08/07/2018 Disapproved -FEE REQUIRED WMILLER
Note: 1. SER SUPPORT STRAPPING FBC R E 3605.7 AND NEC.334 NEEDS TO BE STRAPPED PER NEC 334 (WITHIN 12 INCHES AND AT 30 INCH ENTERVALS ) 2. FIRE BLOCKING AT DROP CIELING IN POOL BATH.... FIREBLOCKING R302.11 1-6 3. 10ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1), 4. NEED A/C LAYOUT/DIAGRAM ON SITE AT TIME OF INSPECTION (WRONG ONE ON SITE)
ELECTRIC-TUG 08/07/2018 APPROVED WMILLER
Note: TALKED TO DELL AT FPL
ELECTRIC-TUG 08/06/2018 CANCELLED BY APPLICANT WEB
GAS ROUGH 08/02/2018 APPROVED JGIBSON
ELECTRIC-TUG 08/02/2018 Disapproved -FEE REQUIRED RMARTIN
Note: TUG OUTLET NEEDS TO BE SECURED
GAS ROUGH 07/27/2018 CANCELLED BY APPLICANT JGIBSON
Note: SUPER CALLED AND CANCEALED
GAS ROUGH 07/25/2018 CANCELLED BY APPLICANT WEB
ROOF VALLEY & METAL 07/25/2018 APPROVED CMINI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/24/2018 APPROVED CMINI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/19/2018 Disapproved -FEE REQUIRED CMINI
Note: cupola not framed correctly, also missing continuous load path . missing structural facia connections. straps incorrect sizes on girder truss. not ready
ROOF SHEATHING 06/08/2018 APPROVED CMINI
TIE BEAM / LINTEL 05/25/2018 APPROVED CMINI
MONOLITHIC SLAB 04/13/2018 APPROVED CMINI
PLUMBING 1ST ROUGH UNDERGROUND 04/05/2018 APPROVED JGIBSON
FOUND SURVEY APPROVED (OFFICE) 03/21/2018 APPROVED DREWIS
FOOTER 01/24/2018 APPROVED CMINI
ELECTRIC TEMP POLE 12/27/2017 Disapproved - NO FEE RMARTIN
Note: THERE IS ALREADY A TEMP POLE AT 23 MAYBE WRONG ADDRESS ......27?

Review History

Department Status Date In Date Out
SW1 COMPLETE 10/29/2018 10/31/2018
Note: Released By: DREWIS
SW1 HOLD 10/23/2018 10/26/2018
Note: Held By: DREWIS final s Property line elevations allow flow onto the adjacent properties, Tech. Manual Sec. 5 Eng. Standard 300.01 A1 c6. Daniel Rewis 986-4736
BLD COMPLETE 07/13/2018 07/16/2018
Note: Released By: JHINDMAN
BLD HOLD 07/06/2018 07/06/2018
Note: Held By: JHINDMAN 1. Identify the location of the ventless fireplace and provide manufacturers specifications. 6th ed. FBC 107.3.5. J. Hindman 986-3784.
PLUM COMPLETE 07/02/2018 07/06/2018
Note: Released By: JHINDMAN
SW1 COMPLETE 03/20/2018 03/21/2018
Note: Released By: DREWIS foundation s
MECH COMPLETE 12/01/2017 12/01/2017
Note: Released By: JHINDMAN
SW1 COMPLETE 11/14/2017 11/16/2017
Note: Released By: DREWIS
MECH HOLD 11/14/2017 11/27/2017
Note: Held By: JHINDMAN 1. Insulation R-value for exterior wood frame shown on energy calculation does not meet with FBCEC 5th ed. R402.1.1. 2nd request. J. Hindman 986-3784.
ZON COMPLETE 11/14/2017 11/15/2017
Note: Released By: TAWILLIAMS
BLD COMPLETE 10/17/2017 10/23/2017
Note: Released By: FREODICA
ELEC COMPLETE 10/17/2017 10/19/2017
Note: Released By: DREWIS
ENGIN1 COMPLETE 10/17/2017 10/18/2017
Note: Released By: TBAKER
MECH HOLD 10/17/2017 10/23/2017
Note: Held By: FREODICA 1. Insulation R-value for exterior wood frame shown on energy calculation does not meet with FBCEC 5th ed. R402.1.1. 2. Provide hvac plan with complete building background (full house) with sufficient clarity for review, construction and inspection and with signature and license number of an hvac contractor FBC 5th ed. 107.2.1/FBC 5th ed. 105.3.1.2. F.Reodica -386-986-4734.
PLUM COMPLETE 10/17/2017 10/23/2017
Note: Released By: FREODICA
SW1 HOLD 10/17/2017 10/19/2017
Note: Held By: DREWIS Please provide proposed survey measurements for grade at foundation wall, 10' away in back and front and on sides per FBC 401.3 D. Rewis 986-4736
UD1 COMPLETE 10/17/2017 10/23/2017
Note: Released By: LFITZGERALD Gravity Sewer new homes This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. The NFPA Clear Zone distance there can be no obstacles in front of the Hydrant and 7.5’ on the sides or 4’ behind.
ZON COMPLETE 10/17/2017 10/18/2017
Note: Released By: AMOBLEY

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 09/25/2018
REINSPECTION FEE ¤40.00 09/25/2018
REINSPECTION FEE ¤40.00 09/25/2018
REVISION ¤40.00 07/20/2018
REVISION ¤40.00 07/20/2018
REINSPECTION FEE ¤40.00 07/20/2018
SITE PLAN 20 ¤20.00 12/08/2017
SURCHARGE FS 533.721 ¤17.07 12/08/2017
SURCHARGE - FS 468.631 ¤25.60 12/08/2017
STORM WATER PERMIT FEES ¤80.00 12/08/2017
3% TRANS IMPACT FEE CREDIT (¤93.74) 12/08/2017
NEW RESIDENTIAL INSPECTIONS ¤708.00 12/08/2017
ADMIN FEE ¤20.00 12/08/2017
ELECTRIC FEE ¤272.40 12/08/2017
3% FIRE IMPACT FEE CREDIT (¤6.56) 12/08/2017
IMPACT FEE FIRE NONRESIDENTIAL ¤218.79 12/08/2017
IMPACT FEE PARKS ¤849.24 12/08/2017
IMPACT FEE SCHOOL ¤3,600.00 12/08/2017
IMPACT FEE TRANSPORTATION ¤3,124.67 12/08/2017
MECHANICAL FEE ¤272.40 12/08/2017
3% PARKS IMPACT FEE CREDIT (¤25.48) 12/08/2017
PLAN CHECK FEE ¤141.60 12/08/2017
PLUMBING FEE ¤272.40 12/08/2017
Fees Total Due: ¤0.00 Total Paid: ¤9,736.39