Permit Details
Status: COED
| Parcel Id: 15-11-31-2970-00000-1250 |
| CONDITIONED SPACE: 2123 sqft |
| GARAGE: 476 sqft |
| OPENED PORCH (WITH ROOF) : 171 sqft |
| OPENED PORCH (WITH ROOF) : 25 sqft |
| Total Square Footage: 2795 sqft |
| Block: 00000 |
| Subdivision: 2070 - Grand Haven North Phase 1 @ Grand Haven |
| Job Phone: 386-236-4133 |
| Location Address: 1 PARK LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/15/2017 |
| NOC: RECORDED |
| Applicant name: LEONARDO CIRO SANCLEMENTE |
| Owner: TADA PROPERTIES LLC |
|
Address 8 LONG LAKE WAY PALM COAST, FL 32137 |
| Lot: 1250 |
| Contracted Stated Job Value: ¤262,410.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
INTERVEST CONSTRUCTION, INC.
| Status | Location Address | State License Number | Phone |
| CANCEL |
2379 BEVILLE RD DAYTONA BEACH, FL 32119 |
CBC1261237 (Exp: 08/31/2020) | 386-236-4133 |
Sub Contractors
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
JEFFREY DALE KNIGHT
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
923 ASHMEADE CT PORT ORANGE, FL 32127 |
CFC057351 (Exp: 08/31/2026) | 386-345-3857 | 386-345-4443 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
ROBERT CRAIG KULP
| Status | Location Address | State License Number | Phone |
| CANCEL |
5401 ENERGY AIR CT ORLANDO, FL 32810 |
CAC1816317 (Exp: 08/31/2022) | 407-886-3729 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 07/26/2018 | FINAL APPROVED | WMILLER |
| U -UTILITY RESIDENTIAL FINAL | 07/26/2018 | FINAL APPROVED | MBACON |
| Note: THIS IS A REINSPECTION | |||
| ROW - FINAL INSPECTION | 07/19/2018 | FINAL APPROVED | KHOWELL |
| U -UTILITY RESIDENTIAL FINAL | 07/19/2018 | Disapproved - NO FEE | LFITZGERALD |
| Note: the 6inch sewer clean out is capped closed, requires a flush mount srew on/off cap so the city has access to this 6 inch service . There is a 4inch, which in future , should be capped and buried leaving only the 6inch. | |||
| ROW - FINAL APRON (AFTER POUR) | 07/19/2018 | APPROVED - AS NOTED | KHOWELL |
| Note: WILLIAM WITH ICI WILL REPLACE 10' OF DAMAGED SIDEWALK | |||
| FINAL SURVEY (OFFICE USE ONLY) | 07/09/2018 | APPROVED | DREWIS |
| ELECTRIC - EARLY POWER | 06/25/2018 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO SUSAN FPL RELEASED EARLY POWER 3:25 | |||
| ROW - FINAL APRON (AFTER POUR) | 06/15/2018 | APPROVED | KHOWELL |
| ROW - DRAINAGE | 06/11/2018 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION. STORM DRAIN NEEDS PROTECTED FROM WASHOUT. | |||
| ROW - DRAINAGE | 06/07/2018 | Disapproved - NO FEE | RGROSS |
| Note: STORMWATER DRAIN NEEDS PROTECTED FROM SEDIMENT WASHOUT. PHONE CALL WARNING WHEN INSPECTION SCHEDULED. NEXT INSPECTION WILL BE FAILED WITH A FEE. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/06/2018 | APPROVED - AS NOTED | RGROSS |
| Note: READY TO POUR. SPOKE TO BUILDER ABOUT PROTECTING THE CATCH BASIN FROM STORM WATER SEDIMENT WASHOUT. | |||
| LATH/BRICK/ WATER BARRIER | 05/14/2018 | APPROVED | WMILLER |
| INSULATION | 04/24/2018 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 04/23/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: THIS IS A REINSPECTION NEED FIREBLOCKING AT BOX-OUT SOFFIT FOR RANGE VENT ...FIREBLOCKING R302.11 (4) PIPES, DUCTS, CABLES, AND WIRES AT CEILING AND FLOOR LEVEL (WITH APPROVED MATERIAL) | |||
| INSULATION | 04/20/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 1. STILL NEED FIRE FOAM AT DRYER EXAUST TOP PLAT. 2. NEED FIRE FOAM AT THERMOSTAT WIRE THROUGH TOP PLATE 3. NEED FIREBLOCKING AT BOX-OUT SOFFIT FOR RANGE VENT ...FIREBLOCKING R302.11 (4) PIPES, DUCTS, CABLES, AND WIRES AT CEILING AND FLOOR LEVEL (WITH APPROVED MATERIAL) 4. STILL NEED 10 FOOT HEAD ...10ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) | |||
| ROOF VALLEY & METAL | 04/18/2018 | APPROVED | CMINI |
| ALL ROUGH | 04/09/2018 | APPROVED - AS NOTED | WMILLER |
| Note: 1. CHANGE OUT FOAM TO FIRE RATED FOAM AT DRYER DUCT AND RANGE VENT FIREBLOCKING R302.11 (4) PIPES, DUCTS, CABLES, AND WIRES AT CEILING AND FLOOR LEVEL (WITH APPROVED MATERIAL) 2. 10ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/06/2018 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| GRAVITY SEWER TEST | 03/29/2018 | APPROVED | JGIBSON |
| U - SEWER TIE IN | 03/29/2018 | APPROVED | JNICHOLS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/27/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: missing required engineering (see detail A/FR1) | |||
| ROOF SHEATHING | 03/20/2018 | APPROVED | WMILLER |
| WALL SHEATHING | 03/20/2018 | APPROVED | WMILLER |
| TIE BEAM / LINTEL | 02/20/2018 | APPROVED | WMILLER |
| ELECTRIC-TUG | 02/16/2018 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO SUSAN FPL RELEASED TUG 3:20 | |||
| FOUND SURVEY APPROVED (OFFICE) | 02/16/2018 | APPROVED | DREWIS |
| MONOLITHIC SLAB | 02/07/2018 | APPROVED | DROCKWELL |
| Note: per William | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/05/2018 | APPROVED - AS NOTED | JGIBSON |
| Note: NEED SLEEVING ON SEWER MAIN WHERE PASSING THRIUGH GARAGE, AND WATER LINES |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 07/06/2018 | 07/09/2018 |
| Note: Released By: DREWIS final survey | |||
| UTL | COMPLETE | 06/13/2018 | 06/26/2018 |
| Note: Released By: MBACON This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. | |||
| ZON | COMPLETE | 06/13/2018 | 06/13/2018 |
| Note: Released By: AMOBLEY | |||
| SW1 | COMPLETE | 06/13/2018 | 06/19/2018 |
| Note: Released By: DREWIS | |||
| ENGIN1 | COMPLETE | 06/13/2018 | 06/14/2018 |
| Note: Released By: TBAKER | |||
| SW1 | COMPLETE | 02/16/2018 | 02/16/2018 |
| Note: Released By: DREWIS foundations | |||
| SW1 | COMPLETE | 12/07/2017 | 12/14/2017 |
| Note: Released By: DREWIS | |||
| BLD | COMPLETE | 12/07/2017 | 12/11/2017 |
| Note: Released By: JHINDMAN | |||
| ZON | COMPLETE | 12/07/2017 | 12/07/2017 |
| Note: Released By: AMOBLEY | |||
| BLD | HOLD | 11/16/2017 | 11/28/2017 |
| Note: Held By: JHINDMAN 1. The attic ventilation calculation does not meet exception 2 for 1/300 per 5th ed. FBC R806 R806.2 Minimum vent area. The minimum net free ventilating area shall be 1/150 of the area of the vented space. Exception: The minimum net free ventilation area shall be 1/300 of the vented space provided one or more of the following conditions are met: 1. In Climate Zones 6, 7 and 8, a Class I or II vapor retarder is installed on the warm-in-winter side of the ceiling. 2. At least 40 percent and not more than 50 percent of the required ventilating area is provided by ventilators located in the upper portion of the attic or rafter space. Upper ventilators shall be located no more than 3 feet (914 mm) below the ridge or highest point of the space, measured vertically, with the balance of the required ventilation provided by eave or cornice vents. Where the location of wall or roof framing members conflicts with the installation of upper ventilators, installation more than 3 feet (914 mm) below the ridge or highest point of the space shall be permitted.. | |||
| ELEC | COMPLETE | 11/16/2017 | 11/17/2017 |
| Note: Released By: DREWIS | |||
| ENGIN1 | COMPLETE | 11/16/2017 | 11/20/2017 |
| Note: Released By: TBAKER | |||
| MECH | COMPLETE | 11/16/2017 | 11/28/2017 |
| Note: Released By: JHINDMAN | |||
| PLUM | COMPLETE | 11/16/2017 | 11/28/2017 |
| Note: Released By: JHINDMAN | |||
| SW1 | HOLD | 11/16/2017 | 11/17/2017 |
| Note: Held By: DREWIS Please provide a site plan with proposed survey measurements depicting: Drainage, Tech. Manual Sec. 5 Eng. Standard 300.01. 5% slope away from foundation wall, FBC R401.3. Daniel Rewis 986-4736 | |||
| UD1 | COMPLETE | 11/16/2017 | 11/20/2017 |
| Note: Released By: MBACON This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. | |||
| ZON | COMPLETE | 11/16/2017 | 11/17/2017 |
| Note: Released By: AMOBLEY |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 07/27/2018 |
| REINSPECTION FEE | ¤40.00 | 07/27/2018 |
| REINSPECTION FEE | ¤40.00 | 07/27/2018 |
| REVISION | ¤40.00 | 07/27/2018 |
| SITE PLAN 20 | ¤20.00 | 12/15/2017 |
| SURCHARGE FS 533.721 | ¤13.25 | 12/15/2017 |
| SURCHARGE - FS 468.631 | ¤19.87 | 12/15/2017 |
| STORM WATER PERMIT FEES | ¤80.00 | 12/15/2017 |
| 3% TRANS IMPACT FEE CREDIT | (¤93.74) | 12/15/2017 |
| NEW RESIDENTIAL INSPECTIONS | ¤526.00 | 12/15/2017 |
| ADMIN FEE | ¤20.00 | 12/15/2017 |
| ELECTRIC FEE | ¤217.80 | 12/15/2017 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.56) | 12/15/2017 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤218.79 | 12/15/2017 |
| IMPACT FEE PARKS | ¤849.24 | 12/15/2017 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 12/15/2017 |
| IMPACT FEE TRANSPORTATION | ¤3,124.67 | 12/15/2017 |
| MECHANICAL FEE | ¤217.80 | 12/15/2017 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 12/15/2017 |
| PLAN CHECK FEE | ¤105.20 | 12/15/2017 |
| PLUMBING FEE | ¤217.80 | 12/15/2017 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,264.64 |