I want to search for...

Permit #2017120574

Permit Details

Status: COED

Parcel Id: 39-12-31-3380-00000-0080
Total Square Footage: 0 sqft
Block: 00000
Subdivision: 2141 - KINGS POINTE COMMERCIAL SUBDIVISION
Job Phone: 407-791-9000
Location Address: 6100 STATE RD 100 E
Type: BC - BUILDING COMMERCIAL
Issue Date: 06/12/2018
NOC: RECORDED
Applicant name: ASHLEY RAY RUMBLE
Owner: LOT 8 KINGS POINTE LLC

Address

2 LAMBERT COVE

FLAGLER BEACH, FL 32136

Lot: 0080
Contracted Stated Job Value: ¤1,300,000.00
Job Description: RaceTrac convenience store 5,411 sq ft
Type: CN

Contractor

CCS CONSTRUCTION , LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

2345 W SAND LAKE ROAD

ORLANDO, FL 32809

SUITE 100

ORLANDO, FL 32809

CBC1257461 (Exp: 08/31/2026) 407-791-9000

Sub Contractors

ROBERT W BINNS
Status Location Address Mailing Address State License Number Phone Fax
INACTIVE

ROBERT BINNS ROOFING INC

WINTER HAVEN, FL 33880

5918 COUNTY RD 542 W`

WINTER HAVEN, FL 33880

CCC1325548 (Exp: 08/31/2024) 863-984-9685 863-984-9688
JAMES W GENGLER
Status Location Address State License Number Phone
INACTIVE

205 COMPLEX DRIVE

LAKELAND, FL 33801

CAC058235 (Exp: 08/31/2022) 863-682-3803
JOHN FRANKLIN GERVOLINO
Status Location Address State License Number Phone
INACTIVE

3957 SALMON DR

ORLANDO, FL 32835

EC13001387 (Exp: 08/31/2020) 407-325-5323
ZENON ANTHONY SZOT
Status Location Address State License Number Phone Fax
CANCEL

2126 LARISSA COURT

TRINITY, FL 34655

CFC057530 (Exp: 08/31/2020) 727-376-8319 727-326-8576
DERRICK SCOTT HARGER
Status Location Address State License Number Phone Fax
ACTIVE

975 SUNSHINE LANE

ALTAMONTE SPRINGS, FL 32714

CFC1425861 (Exp: 08/31/2026) (407)295-1000 (407)295-0000

Inspection History

Type Request Date Result Inspector
U - UTILITY COMMERCIAL FINAL 12/11/2018 FINAL APPROVED MBACON
U - UTILITY COMMERCIAL FINAL 12/10/2018 CANCELLED BY INSPECTOR DSPENCER
Note: THIS IS A REINSPECTION all of the conditions of the developement order are not complete not ready for this inspection at this time no fee
U - UTILITY COMMERCIAL FINAL 12/07/2018 CANCELLED BY APPLICANT LFITZGERALD
Note: THIS IS A REINSPECTION-final site still not ready
U - UTILITY COMMERCIAL FINAL 12/06/2018 CANCELLED BY APPLICANT MBACON
Note: Not Ready
BUILDING FINAL 12/06/2018 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
LDSC- LANDSCAPE FINAL 12/06/2018 CANCELLED BY INSPECTOR BDAWSON
FIRE FINAL 11/19/2018 APPROVED DREWIS
BUILDING FINAL 11/19/2018 PARTIALLY APPROVED RLEE
Note: still need to complete building items stone missing on exterior bath accessory fixtures need hung
ELECTRIC FINAL 11/16/2018 APPROVED - AS NOTED RMARTIN
Note: NEED SIGN AT ROLL UP DOOR INDICATING SERVICE DISCONNECT
U-GREASE INTERCEPTOR PRE-INSTALLATION 11/15/2018 APPROVED MBACON
U-GREASE INTERCEPTOR INSTALLED/PLUMBED 11/15/2018 APPROVED MBACON
U-GREASE INTERCEPTOR FLOW/DYE TESTED 11/15/2018 APPROVED MBACON
U - SEWER TIE IN 11/15/2018 APPROVED - AS NOTED JGIBSON
Note: MARTY BACON MEET ME ON THIS INSPECTION BECAUSE OF HIS KNOWLEDGE OF JOB SITE
PLUMBING FINAL 11/14/2018 APPROVED - AS NOTED JGIBSON
Note: NEED TO PLUG DRAIN ON ROOF TOP YARD HYDRANT, NEED TO INSTALL NEW CELINOID FOR BUBBLER BEFORE BUILDING FINAL
ELECTRIC FINAL 11/09/2018 PARTIALLY APPROVED RMARTIN
Note: PENDING HEADS ON POLES,TESTING THEM,MAIN DISCONNECT LABEL ON ROLL UP DOOR
ELECTRIC OTHER 11/07/2018 APPROVED - AS NOTED RMARTIN
Note: LOOKED AT RTU MOCP ALL ROOF TOP UNITS
ELECTRIC - EARLY POWER 11/07/2018 APPROVED RMARTIN
ELECTRIC 2ND ROUGH 10/31/2018 APPROVED RMARTIN
ELECTRIC - EARLY POWER 10/30/2018 APPROVED RMARTIN
PLUMBING FINAL 10/30/2018 Disapproved -FEE REQUIRED JGIBSON
Note: NOT READY SINKS NOT IN MISSING MIXING VALVE AT HEATER SAN - TEES AT 3 COMPARTMENT SINK ROOF HYDRANT NOT INSTALLED INCOMPLETE INSPECTION
HVAC FINAL 10/29/2018 APPROVED JHINDMAN
HVAC FINAL 10/26/2018 Disapproved - NO FEE JHINDMAN
Note: units must be operational for inspection. 6th ed. FBC 110.
ELECTRIC - EARLY POWER 10/26/2018 APPROVED - AS NOTED RMARTIN
Note: panels
ELECTRIC - EARLY POWER 10/24/2018 APPROVED RMARTIN
ELECTRIC - EARLY POWER 10/23/2018 APPROVED - AS NOTED RMARTIN
Note: panels m1,m2
HVAC ROUGH 10/22/2018 APPROVED CMINI
PLUMBING 2ND ROUGH 10/22/2018 APPROVED - AS NOTED JGIBSON
Note: THIS WAS FOR INSULATION ON WATER LINES IN CEILING AREAS
ABOVE CEILING 10/22/2018 APPROVED CMINI
FRAMING 10/19/2018 APPROVED - AS NOTED DROCKWELL
Note: Patio column wraps
ELECTRIC - EARLY POWER 10/19/2018 APPROVED - AS NOTED RMARTIN
Note: POWER TO PANEL FOR RTU1 AND2
ELECTRIC - EARLY POWER 10/17/2018 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED EARLY POWER 2:45
LATH/BRICK/WATER BARRIER 10/08/2018 APPROVED DROCKWELL
ELECTRIC 2ND ROUGH 09/14/2018 Disapproved - NO FEE RMARTIN
Note: NOT READY, CONDUITS ABOVE MDP
HVAC ROUGH 09/13/2018 PARTIALLY APPROVED CMINI
Note: duct seal on all, ok to wrap all
HVAC ROUGH 09/12/2018 PARTIALLY APPROVED CMINI
Note: main trunck lines duct seal, highlighted on plan
WINDOW NAILING 09/12/2018 APPROVED CMINI
MONOLITHIC SLAB 09/12/2018 PARTIALLY APPROVED CMINI
Note: tank slab
WINDOW NAILING 09/07/2018 CANCELLED BY APPLICANT DROCKWELL
INSULATION 09/07/2018 APPROVED DROCKWELL
PLUMBING 2ND ROUGH 09/07/2018 PARTIALLY APPROVED JGIBSON
Note: THIS WAS FOR ROOF DRAINS ''3''
ELECTRIC 2ND ROUGH 09/07/2018 APPROVED RMARTIN
ELECTRIC 2ND ROUGH 09/06/2018 APPROVED - AS NOTED RMARTIN
Note: HIGH CEILING ONLY
PLUMBING 2ND ROUGH 09/06/2018 PARTIALLY APPROVED JGIBSON
Note: BATHROOM AND KITCHEN WALL AREAS ARE GOOD AND PER PLAN, NEED ROOF DRAINS TESTED AND INSPECTED, WILL CALL WHEN READY
EXTERIOR WALL SHEATHING / SHEARWALL 09/06/2018 APPROVED CMINI
FRAMING 09/06/2018 PARTIALLY APPROVED CMINI
Note: interior framing
FRAMING 09/05/2018 CANCELLED BY APPLICANT CMINI
Note: THIS IS A REINSPECTION. plumbing inspection did not pass, need to have allelec tric and plumbing pass before framing inspection
PLUMBING 1ST ROUGH 09/05/2018 CANCELLED BY INSPECTOR JGIBSON
Note: THIS IS A REINSPECTION this was wrong inspection called in needs to have second rough plumbing added to permit
ELECTRIC 2ND ROUGH 09/05/2018 PARTIALLY APPROVED RMARTIN
Note: THIS IS A REINSPECTION walls only
ELECTRIC 2ND ROUGH 08/31/2018 PARTIALLY APPROVED RMARTIN
Note: THIS IS A REINSPECTION patio marked on print
INSULATION 08/31/2018 CANCELLED BY APPLICANT DROCKWELL
Note: THIS IS A REINSPECTION
INSULATION 08/29/2018 PARTIALLY APPROVED DROCKWELL
Note: Exterior wall insulation where coolers will be located
ELECTRIC 2ND ROUGH 08/28/2018 PARTIALLY APPROVED RMARTIN
Note: COOLER WALLS MARKED ON PRINT
EXTERIOR WALL SHEATHING / SHEARWALL 08/27/2018 PARTIALLY APPROVED DROCKWELL
Note: Exterior walls only.No entry columns or overhange yet
ROOF SHEATHING / BRACE / TIE DOWN 08/23/2018 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION. ISO board screw down
MONOLITHIC SLAB 08/23/2018 APPROVED - AS NOTED CMINI
Note: patio slab at front
HVAC ROUGH 08/23/2018 CANCELLED BY APPLICANT CMINI
FRAMING 08/20/2018 PARTIALLY APPROVED DROCKWELL
Note: THIS IS A REINSPECTION/ Lower exterior wall framing and upper framing complete
ROOF SHEATHING / BRACE / TIE DOWN 08/20/2018 PARTIALLY APPROVED DROCKWELL
Note: Upper exterior wall sheathing at the interior of the studs roof side.Needed for dry-in prep Marked and dated on plans
FRAMING 08/16/2018 PARTIALLY APPROVED DROCKWELL
Note: Roof framing exterior walls only
FOOTER 07/24/2018 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION, 2 pier columns changed to concrete, need revision by next inspection
ELECTRIC TEMP POLE 07/24/2018 CANCELLED BY INSPECTOR DREWIS
Note: Temp pole will be inspected under permit 2018070868. Daniel Rewis 986-4736
ELECTRIC OTHER 07/20/2018 APPROVED - AS NOTED RMARTIN
Note: UFER BONDING IN SLAB
MONOLITHIC SLAB 07/20/2018 APPROVED DROCKWELL
ELECTRIC 1ST ROUGH 07/18/2018 APPROVED RMARTIN
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH 07/13/2018 APPROVED JGIBSON
Note: THIS COMPLETES ALL UNDER GROUND PLUMBING
PLUMBING 1ST ROUGH 07/12/2018 PARTIALLY APPROVED JGIBSON
Note: BATHROOMS AND PATIO FLOOR DRAINS THAT ARE NOT TIED INTO SANITARY THEY ARE TIED INTO STORM DRAIN NO PRIMERS NEEDED
ELECTRIC 1ST ROUGH 07/11/2018 PARTIALLY APPROVED RMARTIN
Note: UNDERGROUND OUT OF BUILDING, MARKED ON PLAN
FOOTER 07/05/2018 PARTIALLY APPROVED DROCKWELL
Note: THIS IS A REINSPECTION/ Column footers only.Marked and dated on plans
FOOTER 06/29/2018 PARTIALLY APPROVED JHINDMAN
Note: spread footings inside building. 2. informed contractor to remove generator from conx roof and ground the system.

Review History

Department Status Date In Date Out
PLUM COMPLETE 07/30/2018 07/30/2018
Note: Released By: FREODICA Revision 4 dated 06-01-18
MECH COMPLETE 07/30/2018 07/31/2018
Note: Released By: FREODICA Revision 4 dated 06-01-18
BLD COMPLETE 06/13/2018 06/27/2018
Note: Released By: JHINDMAN
ELEC COMPLETE 06/13/2018 06/21/2018
Note: Released By: DREWIS
MECH HOLD 06/13/2018 06/21/2018
Note: Held By: FREODICA Revision 4 dated 6-1-18: Provide revision form with description of changes and a "clowded symbol " on revised mechanical plans to identify the changes done per FBC 6th ed. 107.2.1. F.Reodica -386-986-4734.
PLUM HOLD 06/13/2018 06/21/2018
Note: Held By: FREODICA Revision 4 dated 6-1-18: Provide revision form with description of changes and a "clowded symbol " on revised plumbing plans to identify the changes done per FBC 6th ed. 107.2.1. F.Reodica -386-986-4734.
FI1 COMPLETE 06/13/2018 06/28/2018
Note: Released By: JHINDMAN
UD1 COMPLETE 03/12/2018 03/12/2018
Note: Released By: DRAMIREZ
DSD COMPLETE 02/28/2018 03/06/2018
Note: Released By: DRAMIREZ
BLD COMPLETE 02/27/2018 02/28/2018
Note: Released By: JHINDMAN
FI1 COMPLETE 02/27/2018 02/28/2018
Note: Released By: JHINDMAN
ZON COMPLETE 02/27/2018 02/28/2018
Note: Released By: JGONZALEZ
UD1 HOLD 02/27/2018 03/01/2018
Note: Held By: CJOHNSON Fees and agreements shall be complete prior to issuance of building permit
ZON HOLD 02/13/2018 02/15/2018
Note: Held By: JGONZALEZ Approved Development order required
UD1 HOLD 02/13/2018 02/20/2018
Note: Held By: CJOHNSON Fees and agreements shall be complete prior to issuance of building permit
MECH COMPLETE 02/13/2018 02/14/2018
Note: Released By: FREODICA
PLUM COMPLETE 02/13/2018 02/14/2018
Note: Released By: FREODICA
FI1 HOLD 02/13/2018 02/15/2018
Note: Held By: JHINDMAN 1. Provide technical specification that the unit has been tested for ventless operation. UL 710b. J. hindman 986-3784.
BLD HOLD 02/13/2018 02/15/2018
Note: Held By: JHINDMAN 1 The revised plans are not digitally signed and sealed. Provide a digitally signed and sealed set of plans. Digital signatures must comply with Florida Statues Chapter 481 and Florida Administrative Rule 61G1-16.005 for architects or Florida Statutes Chapter 471 and Florida Administrative Rule 61G15-23.003 for Engineers. The following statement must accompany a digital signature “This item has been electronically signed and sealed by (name) On (date) using a Digital Signature”. Certificate Authority services can be purchased through a third party certification authority to include, but not limited to: • • Entrust • • eTrust • • GeoTrust • • GlobalSign • • IdenTrust • • Verisign A digitally created image of the seal must be on the plans for printing purposes. J. Hindman 986-3784.
BLD HOLD 12/18/2017 12/29/2017
Note: Held By: JHINDMAN 1. Provide the correct code reference 2011 National Electric Code not the 2014 NEC. 2. Seperate permits are required for the Fuel Canopy, Dumpster enclosure, Hood and Suppression systems. J. Hindman 986-3784.
ELEC COMPLETE 12/18/2017 12/20/2017
Note: Released By: DREWIS
FI1 HOLD 12/18/2017 12/29/2017
Note: Held By: JHINDMAN 1. Provide a type 1 hood with supression system for the convection ovens. nfpa96.
MECH HOLD 12/18/2017 12/28/2017
Note: Held By: FREODICA Mechanical plans shall be digitally signed and sealed by design engineer per FBC 5th ed. 107.3. F.Reodica - 386-986-4734.
PLUM HOLD 12/18/2017 12/29/2017
Note: Held By: FREODICA Provide digitally signed and sealed plumbing plans by design engineer per FBC 5th ed. 107.3. F.Reodica -386-986-4734.
UD1 HOLD 12/18/2017 12/22/2017
Note: Held By: CJOHNSON Fees, agreements and FDEP permits or Engineers Letter of Determination shall be complete prior to issuance of building permit
ZON HOLD 12/18/2017 12/19/2017
Note: Held By: JGONZALEZ Approved Development order required .

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
AUTHORIZATION LETTER ¤500.00 11/19/2018
REINSPECTION FEE ¤40.00 11/13/2018
REVISION ¤40.00 08/17/2018
REVISION ¤40.00 08/17/2018
CONTRACTOR CHANGE ¤40.00 08/17/2018
CONTRACTOR CHANGE ¤40.00 08/17/2018
ELECTRIC FEE ¤840.00 06/12/2018
3% FIRE IMPACT FEE CREDIT (¤45.03) 06/12/2018
IMPACT FEE FIRE NONRESIDENTIAL ¤1,501.01 06/12/2018
IMPACT FEE TRANSPORTATION ¤104,751.44 06/12/2018
MECHANICAL FEE ¤840.00 06/12/2018
PLAN CHECK FEE ¤1,495.00 06/12/2018
PLUMBING FEE ¤840.00 06/12/2018
SITE PLAN 20 ¤20.00 06/12/2018
SURCHARGE FS 533.721 ¤40.95 06/12/2018
SURCHARGE - FS 468.631 ¤61.43 06/12/2018
3% TRANS IMPACT FEE CREDIT (¤3,142.54) 06/12/2018
INSPECTION - COMMERCIAL ADD ¤9,100.00 06/12/2018
CONTRACTOR CHANGE ¤40.00 06/12/2018
CONTRACTOR CHANGE ¤80.00 06/12/2018
ADMIN COMMERCIAL ¤60.00 06/12/2018
Fees Total Due: ¤0.00 Total Paid: ¤117,182.26