I want to search for...

Permit #2018031208

Permit Details

Status: COED

Parcel Id: 20-12-31-2950-00000-0500
CONDITIONED SPACE: 2335 sqft
GARAGE: 634 sqft
OPENED PORCH (WITH ROOF) : 260 sqft
OPENED PORCH (WITH ROOF) : 97 sqft
SCREEN PORCH (SOLID ROOF) : 315 sqft
Total Square Footage: 3641 sqft
Block: 00000
Subdivision: 2133 - GRAND LANDINGS - PHASE 1
Job Phone: (386) 446-5850
Location Address: 119 COOPERS HAWK WAY
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/06/2018
NOC: RECORDED
Applicant name: CHARLES DALLAS RINEK
Owner: JOHN & CAROLYN SIERRA

Address

119 S COOPERS HAWK

PALM COAST, FL 32137

Lot: 0500
Contracted Stated Job Value: ¤175,000.00
Job Description: New Single Family Home
Type: CN

Contractor

CHARLES RINEK CONSTRUCTION, INC.
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 352502

Palm Coast, FL 32137

CGC046080 (Exp: 08/31/2026) (386) 446-5850 (386)445-9992

Sub Contractors

JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
THOMAS A REGULA
Status Location Address State License Number Phone Fax
INACTIVE

11320 PHILLIPS PKWY DRIVE E

JACKSONVILLE, FL 32256

CMC1250075 (Exp: 08/31/2026) 904-278-0339 904-278-0366
BERT S MCLAUGHLIN
Status Location Address State License Number Phone
ACTIVE

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

EC13006455 (Exp: 08/31/2026) 386-265-2687
STEPHEN CARMAN KENNY
Status Location Address State License Number Phone
ACTIVE

PO BOX 246

FLAGLER BEACH, FL 32136

CCC1330218 (Exp: 08/31/2026) 386-931-4614

Inspection History

Type Request Date Result Inspector
ROW - FINAL INSPECTION 01/04/2019 FINAL APPROVED KHOWELL
BLD - BUILDING FINAL 01/03/2019 FINAL APPROVED DROCKWELL
U-CROSS CONNECTION 12/20/2018 APPROVED MBACON
U -UTILITY RESIDENTIAL FINAL 12/20/2018 FINAL APPROVED MBACON
ROW - FINAL APRON (AFTER POUR) 12/20/2018 APPROVED CTROHA
ROW - FINAL INSPECTION 12/20/2018 Disapproved -FEE REQUIRED CTROHA
Note: A SECTION OF THE SIDEWALK WAS REPOURED WITH OUT AN INSPECTION WHERE THE RE-USE VALVE IS LOCATED MIAMI CURB WAS PATCHED AND IF FAILING I RECOMMEND USING CONCRETE WITH A BINDER OR MASTIC MIX SO THE PATCH WILL HOLD
FINAL SURVEY (OFFICE USE ONLY) 12/19/2018 APPROVED DREWIS
Note: THIS IS A REINSPECTION
FINAL SURVEY (OFFICE USE ONLY) 12/12/2018 Disapproved - NO FEE DREWIS
Note: Provide additonal elevations for drainage per the City of Palm Coast Tech. Manual Sec. 5 Eng. Standard 300 and additional elevations for grade at and away from the foundation wall per Residential Florida Building Code R401.3. Daniel Rewis 986-4736
ROW - FINAL APRON (AFTER POUR) 11/09/2018 Disapproved - NO FEE CTROHA
Note: NOT READY FOR INSPECTION PAVERS NOT INSTALLED NOTE: BASE IS TOO WET I RECCOMEND PUTTING IN SOME DRY MATERILA AND COMPACTING BEFORE LAYING PAVERS
TUB SET 11/07/2018 APPROVED JGIBSON
ROW- PRE-APRON (PRE-POUR) 11/05/2018 APPROVED CTROHA
Note: READY TO POUR It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete.
ROW- PAVER RESTRAINTS 11/05/2018 APPROVED CTROHA
U - SEWER TIE IN 10/05/2018 APPROVED MBACON
GRAVITY SEWER TEST 10/05/2018 APPROVED JGIBSON
LATH/BRICK/ WATER BARRIER 09/28/2018 APPROVED DROCKWELL
ELECTRIC - EARLY POWER 09/25/2018 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED EARLY POWER 2:00
LATH/BRICK/ WATER BARRIER 08/08/2018 APPROVED DROCKWELL
PROJECT STATUS (OFFICE USE) 08/07/2018 CANCELLED BY APPLICANT WEB
LATH/BRICK/ WATER BARRIER 08/07/2018 CANCELLED BY APPLICANT DROCKWELL
ELECTRIC-TUG 08/06/2018 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED POWER 11:30
INSULATION 08/02/2018 APPROVED JHINDMAN
ALL ROUGH 07/27/2018 APPROVED - AS NOTED DROCKWELL
Note: Need water test on shower liner min2in/Tighten all threaded rods/Nail truss strap garage left side.Call in a tub set inspection when ready
ROOF VALLEY & METAL 07/19/2018 APPROVED DROCKWELL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/09/2018 APPROVED CMINI
WALL SHEATHING 07/06/2018 APPROVED CMINI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/06/2018 CANCELLED BY APPLICANT CMINI
FOUND SURVEY APPROVED (OFFICE) 06/25/2018 APPROVED DREWIS
MONOLITHIC SLAB 06/14/2018 CANCELLED BY APPLICANT AIRS WEB
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB 06/13/2018 APPROVED DROCKWELL
PLUMBING 1ST ROUGH UNDERGROUND 06/07/2018 APPROVED JGIBSON

Review History

Department Status Date In Date Out
SW1 COMPLETE 12/17/2018 12/19/2018
Note: Released By: DREWIS
SW1 HOLD 12/11/2018 12/12/2018
Note: Held By: DREWIS Provide additonal elevations for drainage per the City of Palm Coast Tech. Manual Sec. 5 Eng. Standard 300 and additional elevations for grade at and away from the foundation wall per Residential Florida Building Code R401.3. Daniel Rewis 986-4736
BLD COMPLETE 06/27/2018 07/03/2018
Note: Released By: JHINDMAN
SW1 COMPLETE 06/22/2018 06/25/2018
Note: Released By: DREWIS foundation s
ZON COMPLETE 04/02/2018 04/03/2018
Note: Released By: AMOBLEY
MECH COMPLETE 04/02/2018 04/03/2018
Note: Released By: FREODICA
SW1 COMPLETE 04/02/2018 04/03/2018
Note: Released By: DREWIS
ENGIN1 COMPLETE 04/02/2018 04/03/2018
Note: Released By: TBAKER
BLD COMPLETE 03/27/2018 03/27/2018
Note: Released By: JHINDMAN
ELEC COMPLETE 03/27/2018 03/29/2018
Note: Released By: JHINDMAN
ENGIN1 COMPLETE 03/27/2018 03/27/2018
Note: Released By: TBAKER
MECH HOLD 03/27/2018 03/28/2018
Note: Held By: FREODICA 1. Certification for energy code compliance on energy calculation shall be signed by the owner/agent per FBCEC 6th ed. R401.2. 2. Energy performance level (EPL) display card shalll be signed by the builder per FBCEC 6th ed. R401.3. F.Reodica -386-986-4734.
PLUM COMPLETE 03/27/2018 03/28/2018
Note: Released By: FREODICA
SW1 HOLD 03/27/2018 03/29/2018
Note: Held By: DREWIS Provide the roadway centerline elevation. Daniel Rewis 986-4736
UD1 COMPLETE 03/27/2018 04/02/2018
Note: Released By: MBACON This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
ZON HOLD 03/27/2018 03/27/2018
Note: Held By: AMOBLEY Survey should have total lot square footage Please specify on survey that driveway will be pavers not brick
URB COMPLETE 03/27/2018 03/28/2018
Note: Released By: JBEAUDET

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 01/04/2019
REVISION ¤40.00 12/11/2018
CONTRACTOR CHANGE ¤40.00 12/11/2018
REINSPECTION FEE ¤40.00 12/11/2018
CONTRACTOR CHANGE ¤40.00 06/13/2018
ADMIN FEE ¤20.00 04/06/2018
NEW RESIDENTIAL INSPECTIONS ¤626.00 04/06/2018
SITE PLAN 20 ¤20.00 04/06/2018
SURCHARGE FS 533.721 ¤15.35 04/06/2018
SURCHARGE - FS 468.631 ¤23.02 04/06/2018
STORM WATER PERMIT FEES ¤80.00 04/06/2018
3% TRANS IMPACT FEE CREDIT (¤93.74) 04/06/2018
ELECTRIC FEE ¤247.80 04/06/2018
3% FIRE IMPACT FEE CREDIT (¤6.56) 04/06/2018
IMPACT FEE FIRE NONRESIDENTIAL ¤218.79 04/06/2018
IMPACT FEE PARKS ¤849.24 04/06/2018
IMPACT FEE SCHOOL ¤3,600.00 04/06/2018
IMPACT FEE TRANSPORTATION ¤3,124.67 04/06/2018
MECHANICAL FEE ¤247.80 04/06/2018
3% PARKS IMPACT FEE CREDIT (¤25.48) 04/06/2018
PLAN CHECK FEE ¤125.20 04/06/2018
PLUMBING FEE ¤247.80 04/06/2018
Fees Total Due: ¤0.00 Total Paid: ¤9,519.89