Permit #2018040528

Permit Details

Status: COED

Parcel Id: 07-11-31-7030-00200-0031
CONDITIONED SPACE: 1461 sqft
CONDITIONED SPACE: 1461 sqft
GARAGE: 510 sqft
GARAGE: 510 sqft
OPENED PORCH (WITH ROOF) : 150 sqft
OPENED PORCH (WITH ROOF) : 150 sqft
OPENED PORCH (WITH ROOF) : 74 sqft
OPENED PORCH (WITH ROOF) : 74 sqft
Total Square Footage: 4390 sqft
Block: 00200
Subdivision: 2154 - SECTION 30-ROYAL PALMS
Location Address: 52 RAINTREE PL
Type: TH2 - TOWNHOUSE -2 UNIT (INFILL LOT)
Issue Date: 05/30/2018
NOC: RECORDED
Applicant name: LUIS JORGE MEDEIROS
Owner: LIZ LEANDRO S CAMPOS

Address

52 RAINTREE PLACE #B

PALM COAST, FL 32164

Lot: 0031
Contracted Stated Job Value: ¤230,000.00
Job Description: SIDE A - 2 UNIT TOWNHOUSE
Type: CN

Contractor

SUN STATE CUSTOM BUILDERS, LLC
Status Location Address State License Number
CANCEL

946 SHADICH DRIVE

ORANGE CITY, FL

CGC1519145 (Exp: 08/31/2022)

Sub Contractors

STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
JOHN ROBERT BLEVINS JR
Status Location Address State License Number Phone Fax
ACTIVE

17 PORWYN LANE

PALM COAST, FL 32164

CAC1816125 (Exp: 08/31/2026) 386-585-8283 386-263-2096
RUSSELL J CARTER
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 302

DELAND, FL 32721

CFC1425938 (Exp: 08/31/2026) 386-736-4220 386-736-4219
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937

Inspection History

Type Request Date Result Inspector
ROW - FINAL APRON (AFTER POUR) 10/03/2019 FINAL APPROVED KHOWELL
Note: THIS IS A REINSPECTION
ROW - FINAL APRON (AFTER POUR) 10/01/2019 Disapproved - NO FEE KHOWELL
Note: THIS IS A REINSPECTION REMOVE CONCRETE THAT IS POURED PAST THE FOOTER INTO THE SWALE AREA ON THE RIGHT SIDE AND RE-SOD
BLD - BUILDING FINAL 09/27/2019 FINAL APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 09/26/2019 Disapproved - NO FEE DROCKWELL
Note: Side A no water pressure/remove wrapping from all alarms...Side B..rem ove all wrapping from alarms
ROW - STORMWATER FINAL 09/26/2019 APPROVED - AS NOTED KHOWELL
Note: REMOVE THE CONCRETE THAT IS POURED PAST THE END OF THE FOOTER OF CULVERT PIPE INTO THE SWALE AREA AND SOD PRIOR TO CALLING THE FINAL AFTER POUR INSPECTION IN
U -UTILITY RESIDENTIAL FINAL 09/26/2019 FINAL APPROVED LFITZGERALD
FINAL SURVEY (OFFICE USE ONLY) 09/25/2019 APPROVED KHOWELL
Note: THIS IS A REINSPECTION
FINAL SURVEY (OFFICE USE ONLY) 07/10/2019 Disapproved - NO FEE KHOWELL
Note: THIS IS A REINSPECTION NEED TO SET UP A SITE MEETING TO LOOK AT THE SURVEY IN THE FIELD
ELECTRIC - EARLY POWER 06/21/2019 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED POWER 2:45
ROW - FINAL APRON (AFTER POUR) 06/21/2019 Disapproved - NO FEE KHOWELL
Note: FINAL SURVEY HAS TO BE APPROVED BEFORE THIS INSPECTION IS DONE
FINAL SURVEY (OFFICE USE ONLY) 06/14/2019 Disapproved - NO FEE KHOWELL
Note: see survey mark up
ROW- PRE-APRON (PRE-POUR) 05/07/2019 APPROVED - AS NOTED KHOWELL
Note: It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist READY TO POUR upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete.
U - SEWER TIE IN 05/01/2019 APPROVED JGIBSON
GRAVITY SEWER TEST 05/01/2019 APPROVED JGIBSON
LATH/BRICK/ WATER BARRIER 03/21/2019 APPROVED DROCKWELL
INSULATION 03/20/2019 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
INSULATION 03/19/2019 Disapproved - NO FEE WMILLER
Note: DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL MISSING ENERGRY CALCS FOR 52 RAINTREE (ALSO SEPARATE PAPERWORK, NEED ONLY THE PAPERWORK FOR THE ADDRESSED PROPERTY BEING INSPECTED).
LATH/BRICK/ WATER BARRIER 03/19/2019 Disapproved -FEE REQUIRED WMILLER
Note: 1. CORNER BEADS NEEDED, 7/8 inch MINIMUM THICKNESS, TABLE R702.1 (1) SEVEN EIGHTHS OF AN INCH REQUIRED OVER WIRE LATH AND SHEATHING (EXTRERIOR) (FRONT DOORS) 2. WEATHER RESISTANT BARRIER (TYVEC/etc.) OVERLAP AT WOOD TO BLOCK INTERSECTION PER MANUFACTURER SPECS AND ASTM SPECS (SLIDERS)
ALL ROUGH 03/15/2019 APPROVED MWILLIAMS
FIREWALL 03/06/2019 APPROVED WMILLER
Note: APPROVED
ROOF VALLEY & METAL 02/05/2019 APPROVED DROCKWELL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/23/2019 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/18/2019 Disapproved -FEE REQUIRED DROCKWELL
Note: Provide solid blocking between trusses top and bottom as so exterior sheathing can be nailed per plan/T-05 strap not nailed/Firewall truss strap not nailed back both sides/Strap trusses to bearing wall right side
LATH/BRICK/ WATER BARRIER 01/18/2019 CANCELLED BY APPLICANT JMONTARULI
TIE BEAM / LINTEL 12/11/2018 APPROVED DROCKWELL
FOUND SURVEY APPROVED (OFFICE) 12/06/2018 APPROVED DREWIS
MONOLITHIC SLAB 11/07/2018 APPROVED DROCKWELL
PLUMBING 1ST ROUGH UNDERGROUND 10/30/2018 APPROVED JGIBSON
STEM WALL FOUNDATION 09/27/2018 APPROVED DROCKWELL
FOOTER 09/11/2018 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
BLD COMPLETE 05/22/2019 09/30/2019
Note: Released By: JMONTARULI Complete all Ricky Lee's conditions
BLD HOLD 04/24/2019 04/26/2019
Note: Held By: RLEE Development order has been issued for lot split for townhouses. A separate permit and a permit modification for this duplex to convert to townhouse. Both permit applications to show new parcel Ids and addressses. Separate finals and COs will have to be issued The final survey to show the lot split.
SW1 COMPLETE 12/06/2018 12/06/2018
Note: Released By: DREWIS foundation s
ZON COMPLETE 05/14/2018 05/14/2018
Note: Released By: AMOBLEY
UD1 COMPLETE 05/14/2018 05/16/2018
Note: Released By: MBACON This is a PEP Tank area. The Pep Panel will be placed 5 feet from the front corner of the building on the same side of the building as the PEP tank that is marked on the Utility marked Site plan. Make sure the electrician places the PEP power wire between 3 feet and 5 feet from the ground. The plumber should exit the slab with the sewer pipe on the side of the building the tank will be on and matching the utility marked site plan, this will reduce any piping under driveways or sidewalks and minimize the fall required. The sewer tie-in inspection must be called in the day before the tie-in. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in visual inspection so he can witness the tie-in. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
ZON HOLD 05/08/2018 05/08/2018
Note: Held By: AMOBLEY Shrubs must wrap both corners of house
ELEC COMPLETE 05/08/2018 05/08/2018
Note: Released By: JHINDMAN
BLD COMPLETE 05/08/2018 05/08/2018
Note: Released By: JHINDMAN
UD1 HOLD 05/08/2018 05/11/2018
Note: Held By: MBACON Both PEP panels must be located on the same side as the PEP tank. Please show both PEP panels located on the same side as the PEP tank. Remove the one on the wrong side.
UD1 HOLD 04/27/2018 05/04/2018
Note: Held By: LFITZGERALD PEP Panels not shown on correct side of building on electrical plans PEP Panel is not shown on the same side as the tank in the electrical plan as the utility marked site plans. Submit a new electrical plan showing PEP Panel on the same side of the building as indicated in the Utility marked site plan
ZON HOLD 04/27/2018 04/27/2018
Note: Held By: AMOBLEY Landscape plan should state sod type and if irrigation will be installed
BLD HOLD 04/27/2018 05/01/2018
Note: Held By: JHINDMAN 1. Provide signed and sealed structural pages. 6th ed. FBC 107.1.2. only s-3 was provided.J. Hindman 986-3784.
ELEC HOLD 04/27/2018 04/30/2018
Note: Held By: DREWIS Provide riser diagram. Daniel Rewis 986-4736
MECH COMPLETE 04/27/2018 05/03/2018
Note: Released By: FREODICA
PLUM COMPLETE 04/27/2018 05/03/2018
Note: Released By: FREODICA
SWALE COMPLETE 04/16/2018 04/25/2018
Note: Released By: TBAKER
BLD HOLD 04/10/2018 04/11/2018
Note: Held By: JHINDMAN 1. Provide signed and sealed structural pages. 6th ed. FBC 107.1.2. Identify the locations of the anchors for the truss to wall connections. 6th ed. FBC R 107.3.5.J. Hindman 986-3784.
ELEC HOLD 04/10/2018 04/11/2018
Note: Held By: JHINDMAN 1.Provide an electrical riser diagram and electrical load calculations 2014 NEC art 220. J. Hindman 986-3784.
ENGIN1 COMPLETE 04/10/2018 04/16/2018
Note: Released By: TBAKER
MECH HOLD 04/10/2018 04/12/2018
Note: Held By: FREODICA 1. Energy performance level (EPL) display card shall be signed by thebuilder per FBCEC 6th ed. R401.3. 2. Energy calculations and Energy performance level (EPL) display card shall be correctly/completely filled- out on items 2,3,12 and 13; design location - either St. Agustine or Daytona beach, Jurisdiction for clarity per FBC 6th 107.2.1. F.Reodica -386-986-4734.
PLUM HOLD 04/10/2018 04/12/2018
Note: Held By: FREODICA Provide sanitary riser diagram either prepared by design professional or a plumbing contractor with signature and license number per FBC 6th ed. 107.1. F.Reodica -386-986-4734.
SW1 COMPLETE 04/10/2018 04/11/2018
Note: Released By: JHINDMAN
UD1 HOLD 04/10/2018 04/11/2018
Note: Held By: MBACON PEP Panel is not shown in the electrical plan. Submit a new electrical plan showing PEP Panel on the building on the same side of the building as indicated in the Utility marked site plan.
ZON HOLD 04/10/2018 04/11/2018
Note: Held By: AMOBLEY Landscape plan should state sod type and if irrigation will be installed Ac pad should be screened with 7 gallon shrubs Must have shrubs wrapping both corners of house

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 09/27/2019
REINSPECTION FEE ¤40.00 09/27/2019
NEW RESIDENTIAL INSPECTIONS ¤770.00 05/30/2018
SITE PLAN 20 ¤20.00 05/30/2018
SURCHARGE FS 533.721 ¤18.37 05/30/2018
SURCHARGE - FS 468.631 ¤27.56 05/30/2018
STORM WATER PERMIT FEES ¤80.00 05/30/2018
TRANSPORTATION IMPACT FEE ¤2,532.00 05/30/2018
3% TRANS IMPACT FEE CREDIT (¤75.96) 05/30/2018
ADMIN FEE ¤20.00 05/30/2018
ELECTRIC FEE ¤291.00 05/30/2018
3% FIRE IMPACT FEE CREDIT (¤13.13) 05/30/2018
IMPACT FEE FIRE NONRESIDENTIAL ¤437.58 05/30/2018
IMPACT FEE PARKS ¤1,698.48 05/30/2018
IMPACT FEE SCHOOL ¤7,200.00 05/30/2018
MECHANICAL FEE ¤291.00 05/30/2018
3% PARKS IMPACT FEE CREDIT (¤50.95) 05/30/2018
PLAN CHECK FEE ¤154.00 05/30/2018
PLUMBING FEE ¤291.00 05/30/2018
Fees Total Due: ¤0.00 Total Paid: ¤13,770.95