Permit #2018040698

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7002-00010-0200
Block: 00010
Subdivision: 2218 - SECTION 2-FLORIDA PARK
Job Phone: 386-767-4972
Location Address: 39 FARRADAY LN
Type: SW - SEAWALL
Issue Date: 06/08/2018
NOC: RECORDED
Applicant name: THAD RAYMOND ADAMEK
Owner: XU LIN & SHI LI XU

Address

39 FARRADAY LANE

PALM COAST, FL 32137

Lot: 0200
Contracted Stated Job Value: ¤15,000.00
Job Description: REPLACE SEAWALL
Type: CN

Contractor

HALIFAX MARINE CONSTRUCTION, INC
Status Location Address State License Number Phone
ACTIVE

945 DUNCAN ROAD

SOUTH DAYTONA, FL 32119

CRC1330178 (Exp: 08/31/2026) 386-767-4972

Inspection History

Type Request Date Result Inspector
SEAWALL FINAL 05/10/2019 APPROVED MWILLIAMS
LDSC-LANDSCAPE/IRRIGATION FINAL 11/08/2018 APPROVED CTROHA
ROW - FINAL INSPECTION 11/08/2018 APPROVED CTROHA
Note: THIS IS A REINSPECTION
SEAWALL DEADMAN CAP 08/14/2018 APPROVED - AS NOTED WMILLER
Note: THIS IS A REINSPECTION APPROVED PRIOR
ROW - FINAL INSPECTION 08/10/2018 Disapproved -FEE REQUIRED KHOWELL
Note: SOD R.O.W. MATCH EXISTING GRADE NEXT TO DISTURBED AREAS, REAR OF PROPERTY NEEDS TO BE STABILIZED TO PREVENT EROSION
PROJECT STATUS (OFFICE USE) 06/26/2018 APPROVED - AS NOTED WMILLER
Note: debris has been removed, ready for back fill
SEAWALL DEADMAN CAP 06/15/2018 APPROVED - AS NOTED WMILLER
Note: (1) 1804.3 Placement of backfill. The excavation outside the foundation shall be backfilled with soil that is free of organic material, construction debris, cobbles and boulders or with a controlled low-strength material (CLSM). The backfill shall be placed in lifts and compacted in a manner that does not damage the foundation or the waterproofing or dampproofing material. (2) EXISTING BUILDINGBG] 1501.4 Manner of removal Waste materials shall be removed in a manner which prevents injury or damage to persons, adjoining properties, and public rights-of-way. (3) OK TO POUR IF CONTRACTOR ADDS A PROJECT STATUS INSPECTION PRIOR TO BACK FILLING
TURBIDITY BARRIER 06/14/2018 APPROVED WMILLER
LDSC-PRE-CLEARING 06/13/2018 APPROVED - AS NOTED RGROSS
Note: NO CLEARING NEEDED. PRE EXISTING HOME ON THIS LOT. SEA WALL REPLACEMENT.

Review History

Department Status Date In Date Out
BLD COMPLETE 06/01/2018 06/06/2018
Note: Released By: JHINDMAN
BLD HOLD 04/13/2018 04/16/2018
Note: Held By: JHINDMAN 1. Identify how the ends of the seawall are to be terminated on the plans. 6th ed. FBC 107.2.1. J. Hindman
ENGIN1 COMPLETE 04/13/2018 04/18/2018
Note: Released By: TBAKER PROVIDE RETURN WALL AT LEFT SIDE OF PROPERRTY
SW1 COMPLETE 04/13/2018 04/16/2018
Note: Released By: JHINDMAN
ZON COMPLETE 04/13/2018 04/16/2018
Note: Released By: TDOAK

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 08/23/2018
REMODEL/ADDITION/ACCES INSPECT ¤40.00 06/08/2018
SITE PLAN 20 ¤20.00 06/08/2018
SURCHARGE FS 533.721 ¤2.00 06/08/2018
SURCHARGE - FS 468.631 ¤2.00 06/08/2018
STORM WATER PERMIT FEES ¤80.00 06/08/2018
ADMIN FEE ¤20.00 06/08/2018
PLAN CHECK FEE ¤40.00 06/08/2018
Fees Total Due: ¤0.00 Total Paid: ¤244.00