I want to search for...
Permit #2018041211
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7023-00090-0060 |
| CONDITIONED SPACE: 1870 sqft |
| GARAGE: 483 sqft |
| OPENED PORCH (WITH ROOF) : 231 sqft |
| OPENED PORCH (WITH ROOF) : 118 sqft |
| Total Square Footage: 2702 sqft |
| Block: 00090 |
| Subdivision: 2191 - SECTION 23-WYNNFIELD |
| Job Phone: 386-447-2202 |
| Location Address: 18 WHITCOCK LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/10/2018 |
| NOC: RECORDED |
| Applicant name: MICHAEL J LILLY |
| Owner: AYM HOLDINGS LLC |
|
Address 24 CLARENDON CT S PALM COAST, FL 32137 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤135,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SERVPRO OF FLAGLER COUNTY
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
2205 DOBBS ROAD BUNNELL, FL 32110 |
CGC1514660 (Exp: 08/31/2024) | 904-429-4457 | 386-206-2188 |
Sub Contractors
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
BRIAN ALLEN MOLL
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
1 ENTERPRISE DRIVE BUNNELL, FL 32110 |
SUITE 8 BUNNELL, FL 32110 |
CAC1815106 (Exp: 08/31/2026) | 386-447-3782 |
MICHAEL ANTONIO QUINONES
| Status | Location Address | State License Number | Phone |
| CANCEL |
2948 1ST ST ST AUGUSTINE, FL 32084 |
CFC1429017 (Exp: 08/31/2022) | 904-735-5097 |
JAMES FRANCIS SUPLEE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1955 ST RF 16 ST AUGUSTINE, FL 32084 |
CCC1329903 (Exp: 08/31/2026) | 904-230-5548 | 904-230-5547 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 11/26/2019 | FINAL APPROVED | FWILLIS |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 11/25/2019 | CANCELLED BY APPLICANT | WMILLER |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 11/22/2019 | CANCELLED BY APPLICANT | JCOLASANTI |
| U -UTILITY RESIDENTIAL FINAL | 11/22/2019 | APPROVED - AS NOTED | MBACON |
| Note: THIS IS A REINSPECTION Sewer cleanout needs to be flush with sod grade | |||
| GRAVITY SEWER TEST | 11/21/2019 | APPROVED - AS NOTED | PBUCKLEY |
| Note: supporting letter on file | |||
| ROW - STORMWATER FINAL | 11/13/2019 | APPROVED | MMAJEWSKI |
| Note: THIS IS A REINSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | 11/01/2019 | Disapproved - NO FEE | LFITZGERALD |
| Note: pep tank sewer clean out cover not observed, please make visible with it being a flush mount cap that is flush with sod grades. | |||
| ROW - DRAINAGE | 11/01/2019 | APPROVED | MMAJEWSKI |
| Note: THIS IS A REINSPECTION | |||
| ROW - STORMWATER FINAL | 11/01/2019 | Disapproved - NO FEE | MMAJEWSKI |
| Note: THERE IS A 20 FOOT LONG AREA IN THE SWALE WHERE THE SOD HAS BEEN TORE UP. THIS WILL NEED TO BE REPLACED. | |||
| GRAVITY SEWER TEST | 11/01/2019 | Disapproved - NO FEE | JCOLASANTI |
| Note: THIS IS A REINSPECTION need to obtain ok from building official to clear inspection | |||
| MONOLITHIC SLAB | 11/01/2019 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION approved at previous inspection | |||
| ROW - FINAL APRON (AFTER POUR) | 10/30/2019 | APPROVED | MMAJEWSKI |
| Note: THIS IS A REINSPECTION | |||
| ROW - FINAL APRON (AFTER POUR) | 10/18/2019 | Disapproved -FEE REQUIRED | RGROSS |
| Note: THIS IS A REINSPECTION. ROAD REPAIR MUST BE HOT PATCH. NOT COLD PATCH. ALSO MUST BE REPAIRED SO AS NOT TO CREATE A TRIPPING HAZARD. | |||
| ROW - FINAL APRON (AFTER POUR) | 10/16/2019 | Disapproved -FEE REQUIRED | MMAJEWSKI |
| Note: THIS IS A REINSPECTION. PAVEMENT IN FRONT OF DRIVEWAY NOT REPAIRED | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/15/2019 | APPROVED | MMAJEWSKI |
| FINAL SURVEY (OFFICE USE ONLY) | 10/15/2019 | APPROVED | MMAJEWSKI |
| ROW - FINAL APRON (AFTER POUR) | 09/11/2019 | Disapproved -FEE REQUIRED | KHOWELL |
| Note: THIS IS A REINSPECTION CONCRETE APRON IS NOT ALLOWED TO BE PORED INTO THE ROADWAY. THIS INSPECTION CAN NOT BE DONE UNTIL THE FINAL SURVEY HGAS BEEN APPROVED TO VERIFY INVERT ELEVATION OF THE CULVERT PIPE IS CORRECT. THE MITERED ENDS IS REQUIRED TO HAVE 2" OF CONCRETE ABOVE THE OPENING OF ON THE CULVERT MITERED END SECTIONS. SAW CUT IS REQUIRED TO BE OVER THE CENTER OF THE CULVERT PIPE PER DETAIL. | |||
| ROW- PRE-APRON (PRE-POUR) | 09/10/2019 | Disapproved -FEE REQUIRED | RGROSS |
| Note: THIS IS A REINSPECTION. APRON SLOPE TOO STEEP. SEE CULVERT DETAIL. NEEDS MORE COMPACTION IN THE APRON. REMOVE ORGANIC GRASS GROWING IN THE POUR AREA. DISREGARD THIS INSPECTION RESULT. INSPECTOR ENTERED INFO ON THE WRONG ADDRESS. | |||
| ROW- PRE-APRON (PRE-POUR) | 09/10/2019 | APPROVED - AS NOTED | RGROSS |
| Note: THIS IS A REINSPECTION. ON SITE WITH SUPER TO ENSURE A FACE BOARD WAS USED ALONG THE ROAD EDGE. AFTER INSTALLED, READY TO POUR. NOTE: THE ORIGINAL INSPECTION FOR THIS CULVERT WAS MISTAKENLY FAILED BY THE INSPECTOR AT A DIFFERENT ADDRESS AND PRE POUR THAT FAILED. THIS WAS RE-SCHEDULED THE SAME DAY BY THE INSPECTOR. ANY QUESTIONS CALL ROBERT 386-793-3980. | |||
| ROW- PRE-APRON (PRE-POUR) | 08/28/2019 | Disapproved -FEE REQUIRED | RGROSS |
| Note: THIS IS A REINSPECTION. NO SWALE PLAN ON SITE. MITERED ENDS NOT FORMED CORRECTLY. SEE CITY WEB SITE SEARCH "DRIVEWAY CULVERT DETAIL" IT IS A PDF FOR HOW MITERED ENDS ARE TO BE FORMED. PHOTO'S ATTACHED. | |||
| ROW- PRE-APRON (PRE-POUR) | 08/14/2019 | Disapproved -FEE REQUIRED | KHOWELL |
| Note: SWALE SHEET NOT IN DOC BOX, PIN THE APRROVED SITE PLAN AND SWALE SHEET TOGETHER DID NOT SHOT CULVERT ELEVATION. REMOVE THE GRASS, REPAIR WASHOUTS AND COMPACT THE PAD AREA. 4" MINIMUM THICK CONCRETE REQUIRED PAST THE R.O.W., 5" MINIMUM THICK CONCRETE REQUIRED IN THE R.O.W. THE MITERED ENDS ARE NOT FORMED PER THE CITY STANDARD DETAIL. A ROAD FORM BOARD IS REQUIRED SO THE INSIDE OF THE FORM LINES UP WITH THE EXISTING EDGE OF PAVEMENT. THE CULVERT FOOTERS ARE REQUIRED TO BE MINIMUM OF 6" DEEP, SEE CITY STANDARD DRIVEWAY DETAIL | |||
| MONOLITHIC SLAB | 08/14/2019 | Disapproved - NO FEE | FWILLIS |
| Note: THIS IS A REINSPECTION Driveway Apron not 6" in areas as required by code. | |||
| ELECTRIC - EARLY POWER | 07/09/2019 | APPROVED | JDELBONIS |
| Note: THIS IS A REINSPECTION not conected in meter panel | |||
| U - SEWER TIE IN | 06/03/2019 | APPROVED - AS NOTED | JGIBSON |
| Note: THIS IS A REINSPECTION STILL NEED TEST ON GRAVITY SEWER AND GRAVITY SEWER INSPECTION | |||
| U - SEWER TIE IN | 05/22/2019 | Disapproved - NO FEE | JGIBSON |
| Note: per contractor NEED C/O AT TAPE LOCATION | |||
| GRAVITY SEWER TEST | 05/22/2019 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: P-312.6 GRAVITY SEWER TEST, NO 5' HEAD TEST | |||
| INSULATION | 03/18/2019 | APPROVED | JCOLASANTI |
| ALL ROUGH | 03/15/2019 | APPROVED - AS NOTED | WMILLER |
| Note: NEED TO SEE THE FOLLOWING BY INSULATION INSPECTION (WAS REQUEST ALREADY AT ALL-ROUGH INSPEDCTION PRIOR) provide 5ft test pressure on waste lines. 5th ed. FBC R P2503.5.1. 2 (SECOND REQUEST) | |||
| INSULATION | 03/13/2019 | Disapproved - NO FEE | JCOLASANTI |
| Note: need to have approved all rough inspection before insullation inspection | |||
| LATH/BRICK/ WATER BARRIER | 03/08/2019 | APPROVED | JCOLASANTI |
| ALL ROUGH | 03/05/2019 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: need to seal tub trench..need to install plastic, treat and seal slab at front guest bedroom... provide 5ft test pressure on waste lines. 5th ed. FBC R P2503.5.1. 2 | |||
| ROW - FINAL INSPECTION | 01/04/2019 | CANCELLED BY APPLICANT | STHOMAS |
| ALL ROUGH | 01/03/2019 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: need exterior doors and windows at time of inspection | |||
| ROOF VALLEY & METAL | 12/27/2018 | APPROVED | JCOLASANTI |
| U - SEWER TIE IN | 12/04/2018 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/03/2018 | APPROVED | MWILLIAMS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/19/2018 | Disapproved -FEE REQUIRED | RLEE |
| Note: need revision to show truss connection to block, detail shows twist straps for repair of missing straps 802 Also need full set of approved plans in organized fashion with truss engineering package on site for next inspection | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/09/2018 | Disapproved - NO FEE | JCOLASANTI |
| Note: need revision to show truss connection to block, detail shows twist straps for repair of missing straps 802 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/06/2018 | Disapproved - NO FEE | JCOLASANTI |
| Note: roof sheathing needs to be complete for this inspection | |||
| ROOF VALLEY & METAL | 11/05/2018 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: not ready for roof valley inspection | |||
| TIE BEAM / LINTEL | 10/09/2018 | APPROVED | JCOLASANTI |
| FOUND SURVEY APPROVED (OFFICE) | 10/08/2018 | APPROVED | DREWIS |
| MONOLITHIC SLAB | 09/25/2018 | APPROVED | JCOLASANTI |
| Note: this inspection already complete, need to call tie beam/lintel | |||
| MONOLITHIC SLAB - GREEN | 09/11/2018 | APPROVED | JCOLASANTI |
| MONOLITHIC SLAB | 09/10/2018 | Disapproved - NO FEE | JCOLASANTI |
| Note: DOCUMENTS MUST BE APPROVED AND KEPT ON SITE AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL 107.3,1. (need documents onsite at time of inspection) | |||
| ELECTRIC TEMP POLE | 08/23/2018 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO SUSAN FPL RELEASED TEMP POWER 10:00 | |||
| ELECTRIC - EARLY POWER | 08/22/2018 | Disapproved - NO FEE | RMARTIN |
| Note: WRONG INSPECTION IS CALLED IN, NEEDS TO BE TEMP POLE INSPECTION | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 08/16/2018 | APPROVED | JCOLASANTI |
| ROW - DRAINAGE | 08/15/2018 | Disapproved - NO FEE | KHOWELL |
| Note: EROSION FROM YOUR SITE IS RUNNING INTO THE SWALE AT 20 WHITCOCK LANE THAT NEEDS TO BE REMOVED AND SILT FENCE INSTALLED ALSO REMOVE DIRT FROM THE SWALE THAT IS BLOCKING THE FLOW OF WATER. THIS WILL BE REINSPECTED FOR CORRECTION ON TUESDAY AUGUST 21, 2018. IF IT HAS NOT BEEN CORRECTED THERE BE INSPECTION FEES FOR THIS UNTIL IT IS CORRECTED | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 08/14/2018 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: P-2503.2 CONCEALMENT-UNCOVER ALL FITTINGS AND PIPE FOR INSPECTION,P-2503.5.1 ROUGH PLUMBING TEST HEAD PRESSURE NOT HOLDING, NEED TO REMOVEALL TREE STUMPS FROM SLAB P-2604.1 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 08/13/2018 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: DOCUMENTS MUST BE APPROVED AND KEPT ON SITE AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL 107.3,1. (need documents onsite at time of inspection)....NOC need to be posted on site....need plumbing riser on site at time of inspection |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/04/2019 | 01/10/2019 |
| Note: Released By: JHINDMAN | |||
| BLD | COMPLETE | 11/14/2018 | 11/21/2018 |
| Note: Released By: RLEE | |||
| SW1 | COMPLETE | 10/03/2018 | 10/08/2018 |
| Note: Released By: DREWIS Foundation survey | |||
| MECH | COMPLETE | 06/29/2018 | 06/29/2018 |
| Note: Released By: FREODICA | |||
| MECH | HOLD | 06/21/2018 | 06/28/2018 |
| Note: Held By: FREODICA Review comments on submitted correction for energy caculations dated 6-21-18 : 1. Insulation R-value for exterior block wall, 8 inch thick (item 9c) shows manually input data of R=4.4 on EPL display card but anotther manually input data for the same wall shows R=0 on page 4 of energy calculation. These insulation R-value data shall be computer-entered into the energy calculation software and not manually- done to be included in the calculations per FBCEC 6th ed. R405.4. 2. Revised equipment sizing calculations shall be included in the submittal package due to changes per FBCEC 6th ed. R403. 7.1. F. Reodica -386-986-4734. | |||
| PLUM | COMPLETE | 06/14/2018 | 06/15/2018 |
| Note: Released By: FREODICA | |||
| MECH | HOLD | 06/14/2018 | 06/15/2018 |
| Note: Held By: FREODICA Repeat comment: Repeat comment: Provide complete package of energy calculations, the number of bedrooms and R- value on block wall stucco (item 9c) are not indicated per FBCEC 6th ed. R405. F.Reodica -386-986-4734. Note: The insulation R-value on block wll stucco (item 9c) on energy calculation still shows zero (0) value. | |||
| UD1 | COMPLETE | 06/07/2018 | 06/13/2018 |
| Note: Released By: LFITZGERALD PEP Tank areas new home This is a PEP Tank area. The Pep Panel will be placed 5 feet from the front corner of the building on the same side of the building as the PEP tank that is marked on the Utility marked Site plan. Make sure the electrician places the PEP power wire between 3 feet and 5 feet from the ground. The plumber should exit the slab with the sewer pipe on the side of the building the tank will be on and matching the utility marked site plan, this will reduce any piping under driveways or sidewalks and minimize the fall required. The sewer tie-in inspection must be called in the day before the tie-in. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in visual inspection so he can witness the tie-in. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. The NFPA Clear Zone distance there can be no obstacles in front of the Hydrant and 7.5’ on the sides or 4’ behind | |||
| PLUM | HOLD | 06/07/2018 | 06/08/2018 |
| Note: Held By: FREODICA Repeat comment: Provide complete pipe sizes and indicate the fixtures name for clarity per FBC 6th ed. 105.3.1. F.Reodica -386-986-4734. | |||
| MECH | HOLD | 06/07/2018 | 06/08/2018 |
| Note: Held By: FREODICA Repeat comment: Provide complete package of energy calculations, the number of bedrooms and R- value on block wall stucco (item 9c) are not indicated per FBCEC 6th ed. R405. F.Reodica -386-986-4734. | |||
| ZON | COMPLETE | 06/07/2018 | 06/08/2018 |
| Note: Released By: AMOBLEY | |||
| ELEC | COMPLETE | 06/07/2018 | 06/11/2018 |
| Note: Released By: DREWIS | |||
| ELEC | HOLD | 05/25/2018 | 05/29/2018 |
| Note: Held By: DREWIS Update code references to the FBC 6ht ed and 2014 NEC. Provide an additional GFCI in the laundry area, 210.52F Daniel Rewis 986-4736 | |||
| SW1 | COMPLETE | 05/25/2018 | 05/31/2018 |
| Note: Released By: DREWIS | |||
| BLD | COMPLETE | 05/25/2018 | 05/31/2018 |
| Note: Released By: JHINDMAN | |||
| UD1 | HOLD | 05/25/2018 | 05/29/2018 |
| Note: Held By: MBACON PEP Panel is not shown in the electrical plan. Submit a new electrical plan showing PEP Panel on the building on the same side of the building as indicated in the Utility marked site plan. | |||
| MECH | HOLD | 05/25/2018 | 05/29/2018 |
| Note: Held By: FREODICA Provide complete package of energy calculations, Energy Performace Level (EPL) display card and other mandatory requirements are missing, the number of bedrooms and R- value on block wall stucco (item 9c) are not indicated per FBCEC 6th ed. R405. F.Reodica -386-986-4734. | |||
| PLUM | HOLD | 05/25/2018 | 05/29/2018 |
| Note: Held By: FREODICA Provide complete pipe sizes and indicate the fixtures name for clarity per FBC 6th ed. 105.3.1. F.Reodica -386-986-4734. | |||
| ZON | HOLD | 05/25/2018 | 05/29/2018 |
| Note: Held By: TDOAK REPEAT COMMENTS: 1. Landscape plan must depict the following: a. There must be a minimum of 4 foundation plantings on the each side of home and 8 foundation plantings in the front. (THIS DOES NOT INCLUDE THE 7 GALLON PLANTS SCREENING THE A/C EQUIPMENT). b. Foundation plantings must wrap the corners of the home. c. What type of sod will be installed? If St Augustine, plans must note that an irrigation system will be included. d. Demonstrate which existing trees will be saved. Also note that saved trees must be barricaded to the dripline throughout the construction process. | |||
| ENGIN1 | COMPLETE | 05/25/2018 | 06/01/2018 |
| Note: Released By: TBAKER | |||
| ENGIN1 | COMPLETE | 05/09/2018 | 05/10/2018 |
| Note: Released By: TBAKER Held By: TBAKER SITE BENCHMARK NEEDS TO BE RESET DUE TO VANDALISM | |||
| SWALE | COMPLETE | 04/27/2018 | 06/01/2018 |
| Note: Released By: TBAKER | |||
| BLD | HOLD | 04/25/2018 | 05/01/2018 |
| Note: Held By: JHINDMAN 1. Provide signed and sealed plans 6th ed. FBC 107.1. J. Hindman 986-3784. | |||
| ELEC | HOLD | 04/25/2018 | 04/27/2018 |
| Note: Held By: DREWIS Provide signature and license number of the electrical contractor on the plans or the signature and seal of an engineer, FBC 6th ed. 107.1. Provide a plan with clear notes, notes provided are too blurred for review. Provide a riser diagram. Provide an additional GFCI in the laundry area, 210.52F Provide receptacles for kitchen counters, bedroom and great area, 210.52. Daniel Rewis 986-4736 | |||
| ENGIN1 | COMPLETE | 04/25/2018 | 04/27/2018 |
| Note: Released By: TBAKER | |||
| MECH | HOLD | 04/25/2018 | 05/02/2018 |
| Note: Held By: FREODICA 1. Provide energy calculations using peformance method per FBCEC 6th ed. R405. 2. Provide complete hvac plan either prepared by design professional or an hvac contractor with signature and license number per FBC 6th ed. 107.1. F.Reodica -386-986-4734. | |||
| PLUM | HOLD | 04/25/2018 | 05/02/2018 |
| Note: Held By: FREODICA Provide sanitary riser diagram either prepared by design professional or a plumbing contractor with signature and license number per FBC 6th ed. 107.1 F.Reodica -386-986-4734. | |||
| SW1 | HOLD | 04/25/2018 | 04/27/2018 |
| Note: Held By: DREWIS Leftside proposed elevation 28.4'-27.3' allow flow from the adjacent property, Tech. Manual Sec. 5 Eng. Standard 300.01 A1 c6. Daniel Rewis 986-4736 | |||
| UD1 | HOLD | 04/25/2018 | 05/02/2018 |
| Note: Held By: MBACON PEP Panel is not shown in the electrical plan. Submit a new electrical plan showing PEP Panel on the building on the same side of the building as indicated in the Utility marked site plan. | |||
| ZON | HOLD | 04/25/2018 | 04/26/2018 |
| Note: Held By: TDOAK 1. Landscape plan must depict the following: a. That as per Land Development Code 11.02.03.D.2, the plan must demonstrate that the minimum NUMBER, TYPE AND SIZE of foundation plantings is being met. b. There must be a minimum of 4 foundation plantings on the each side of home and 8 foundation plantings in the front. c. Foundation plantings must wrap the corners of the home. d. A/C must be screened from the public right-of-way as well as neighboring property with 7 gallon plantings. e. Demonstrate which existing trees will be saved. Also note that saved trees must be barricaded to the dripline throughout the construction process. 2. Color Sheet must depict the garage door color name, manufacturer and its LRV. 3. Plans must show all exterior elevations, not just the right and left. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ELECTRIC FEE | ¤205.20 | 07/10/2018 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.56) | 07/10/2018 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤218.79 | 07/10/2018 |
| IMPACT FEE PARKS | ¤849.24 | 07/10/2018 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 07/10/2018 |
| IMPACT FEE TRANSPORTATION | ¤1,632.00 | 07/10/2018 |
| MECHANICAL FEE | ¤205.20 | 07/10/2018 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 07/10/2018 |
| PLAN CHECK FEE | ¤96.80 | 07/10/2018 |
| PLUMBING FEE | ¤205.20 | 07/10/2018 |
| ADMIN FEE | ¤20.00 | 07/10/2018 |
| NEW RESIDENTIAL INSPECTIONS | ¤484.00 | 07/10/2018 |
| SITE PLAN 20 | ¤20.00 | 07/10/2018 |
| SURCHARGE FS 533.721 | ¤12.36 | 07/10/2018 |
| SURCHARGE - FS 468.631 | ¤18.55 | 07/10/2018 |
| STORM WATER PERMIT FEES | ¤80.00 | 07/10/2018 |
| 3% TRANS IMPACT FEE CREDIT | (¤48.96) | 07/10/2018 |
| REVISION | ¤40.00 | |
| CONTRACTOR CHANGE | ¤40.00 | |
| CONTRACTOR CHANGE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| Fees | Total Due: ¤640.00 | Total Paid: ¤7,566.34 |