Permit #2018041290

Permit Details

Status: COED

Parcel Id: 42-10-30-3210-00000-2930
CONDITIONED SPACE: 2856 sqft
OPENED PORCH (WITH ROOF) : 395 sqft
OPENED PORCH (WITH ROOF) : 131 sqft
GARAGE: 590 sqft
Total Square Footage: 3972 sqft
Block: 0
Subdivision: 2094 - CONSERVATORY AT HAMMOCK BEACH
Job Phone: 386-947-4481
Location Address: 450 SWEETGUM LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/03/2018
NOC: RECORDED
Applicant name: ERIC CHRISTOPHER OLSEN
Owner: MANN GERALD F & JOANNE L H&W

Address

7745 SUMMIT ROCH POINT

COLUMBUS, OH 43235

Lot: 293
Contracted Stated Job Value: ¤687,000.00
Job Description: NEW SINGLE FAMILY RESIDENTIAL
Type: CN

Contractor

OLSEN CUSTOM HOMES AND CONSULTING INC
Status Location Address State License Number Phone Fax
ACTIVE

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

CGC1508852 (Exp: 08/31/2026) 386-947-4481 (386)947-4484

Sub Contractors

BERT S MCLAUGHLIN
Status Location Address State License Number Phone
ACTIVE

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

EC13006455 (Exp: 08/31/2026) 386-265-2687
JEFFREY DALE KNIGHT
Status Location Address State License Number Phone Fax
INACTIVE

923 ASHMEADE CT

PORT ORANGE, FL 32127

CFC057351 (Exp: 08/31/2026) 386-345-3857 386-345-4443
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/07/2019 APPROVED MWILLIAMS
BLD - BUILDING FINAL 01/17/2019 Disapproved -FEE REQUIRED WMILLER
Note: 1. HOLES IN WALLS OR CEILINGS MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 BUILDING (AHU ceiling) 2. SPACES AROUND PIPES MUST BE SEALED….SEALING OF ANNULAR SPACES…P2606.1 (behind consenser) 3. EXHAUST VENTS TERMINATE 3 feet FROM OPENINGS FBC.R.M1506 CANNOT TERMINATE WITHIN 3 feet OF OPENINGS (OPERABLE OR NON-OPERABLE) 4. WEATHER STRIPPING NEEDS TO BE INSTALLED R 612.1 FBC 5. HALL LIGHT AT POOL BATH NOT WORKING 6. EXHAUST FANS IN BOTH BATHS ON RIGHT SIDE OF HOUSE NOT WORKING
ROW - FINAL INSPECTION 01/16/2019 APPROVED - AS NOTED RGROSS
Note: PER SUPER. SLEEVES CUT AND CAPPED WITH TEMPORARY CAPS IN DRIVEWAY UNTIL BRASS CAPS ARRIVE. BRASS CAPS HAVE BEEN ORDERED.
ROW - FINAL INSPECTION 01/11/2019 Disapproved -FEE REQUIRED CTROHA
Note: Repair erosion from roof drains Valve sleves need to be cut and capped in the driveway
ROW- PRE-APRON (PRE-POUR) 01/11/2019 APPROVED CTROHA
ROW - FINAL APRON (AFTER POUR) 01/11/2019 APPROVED - AS NOTED CTROHA
Note: The Conservatory has valve sleves in the driveway that need cut and capped before final row inspection
FINAL SURVEY (OFFICE USE ONLY) 01/11/2019 APPROVED JHINDMAN
ROW- PAVER RESTRAINTS 12/13/2018 APPROVED RGROSS
U -UTILITY RESIDENTIAL FINAL 12/13/2018 FINAL APPROVED JNICHOLS
ROW - FINAL APRON (AFTER POUR) 12/06/2018 Disapproved - NO FEE RGROSS
Note: NOT READY FOR FINAL INSPECTION. POSSIBLE WRONG INSPECTION SCHEDULED. NO FEE.
ROW- PRE-APRON (PRE-POUR) 11/16/2018 PARTIALLY APPROVED RGROSS
Note: APPROVED FOR CONCRETE APRON POUR ONLY. PAVER DRIVEWAY. PAVER RESTRAINTS NOT READY.
ELECTRIC - EARLY POWER 11/07/2018 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED EARLY POWER 3:35
ELECTRIC - EARLY POWER 11/06/2018 Disapproved -FEE REQUIRED RMARTIN
Note: NEED APPROVED REVISION OF ELECTRIC SERVICE CHANGE ON SITE, ALSO PLANS ON SITE NEED ATTENTION
GRAVITY SEWER TEST 10/15/2018 APPROVED WMILLER
Note: APPROVED
U - SEWER TIE IN 10/15/2018 APPROVED DSPENCER
LATH/BRICK/ WATER BARRIER 10/01/2018 APPROVED CMINI
INSULATION 09/24/2018 APPROVED CMINI
INSULATION 09/21/2018 Disapproved -FEE REQUIRED WMILLER
Note: CORRECTIONS NOT MADE 1. STILL NEED NAIL PLATE AT DRYER VENT (ASKED FOR AT ALL-ROUGH AND ALL-ROUGH REINSPECT) 2. FIREBLOCKING R302.11 1-6 ELECTRIC THROUGH FIRE BLOCKING AND TOP PLATE AT REF. AND PANTRY
INSULATION 09/13/2018 Disapproved -FEE REQUIRED WMILLER
Note: 1. STILL NEED NAIL PLATE AT DRYER VENT (ASKED FOR AT ALL-ROUGH AND ALL-ROUGH REINSPECT) 2. FIREBLOCKING R302.11 1-6 ELECTRIC THROUGH FIRE BLOCKING AND TOP PLATE AT REF. AND PANTRY
ALL ROUGH 09/07/2018 APPROVED - AS NOTED CMINI
Note: nail plate at dryer vent
ALL ROUGH 09/05/2018 Disapproved -FEE REQUIRED WMILLER
Note: TO MANY DEFICIENT ITEMS, INSPECTION STOPPED, INCOMPLETE LIST, 1. BOX OUT AROUND ELECT OVER PANELS 2. 5ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) 3. PRESSURE TEST FOR SUPPLLY LINES P2503.7 WATER SUPPLY-SYSTEM TESTING. 4. NEED TO SEAL DRYER DUCT AT ROOF WITH MASTIC..FBC.. M1502.4.2 AND M1601.4.1 26 5. NAIL PLATES FBC 26 R, M1308.2 PROTECTION FROM PHYSICAL DAMAGE 26 INSPECTION STOPPED NOTHING FURTHER LOOKED AT
ELECTRIC-TUG 08/27/2018 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED TUG POWER 2:50 NEED REVISION ON 300 AMP SERVICE BY EARLY POWER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/20/2018 APPROVED WMILLER
ROOF VALLEY & METAL 08/20/2018 APPROVED WMILLER
ROOF VALLEY & METAL 08/17/2018 Disapproved - NO FEE CMINI
Note: roof sheathing/braces/ties and down cell inspection 2460, needs to be passed before this inspection can be passed
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/03/2018 Disapproved - NO FEE CMINI
Note: sheathing only nail down, need to call back when anchor,ties and engineering complete
TIE BEAM / LINTEL 07/23/2018 APPROVED WMILLER
TIE BEAM / LINTEL 07/20/2018 Disapproved -FEE REQUIRED WMILLER
Note: OVERBEND DOWEL BAR FBC R606.13.3 EXCEPTION 26.. MARKED ON SHEET 5
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/20/2018 CANCELLED BY APPLICANT WEB
FOUND SURVEY APPROVED (OFFICE) 07/13/2018 APPROVED DREWIS
MONOLITHIC SLAB 06/27/2018 APPROVED WMILLER
MONOLITHIC SLAB 06/25/2018 Disapproved -FEE REQUIRED WMILLER
Note: not ready for inspection, incomplete
PLUMBING 1ST ROUGH UNDERGROUND 06/19/2018 APPROVED - AS NOTED JGIBSON
Note: NEED REVISION TO SHOW SUMMER KIT. ON RISER AT BACK BATH ROOM,NEED BY LINTEL INSPECTION

Review History

Department Status Date In Date Out
MECH COMPLETE 01/31/2019 02/06/2019
Note: Released By: JHINDMAN
MECH HOLD 01/22/2019 01/29/2019
Note: Held By: JHINDMAN 1. Provide the builders signature on page 1 of form r405 and the EPL card on the revised calculations
SW1 COMPLETE 01/08/2019 01/10/2019
Note: Released By: JHINDMAN Final S
BLD COMPLETE 12/20/2018 12/28/2018
Note: Released By: RLEE
ELEC COMPLETE 09/04/2018 09/10/2018
Note: Released By: JHINDMAN
SW1 COMPLETE 07/12/2018 07/13/2018
Note: Released By: DREWIS foundation s
PLUM COMPLETE 06/29/2018 07/05/2018
Note: Released By: FREODICA Revision : changed sanitary risesr diagram-added summer kitchen sink.:
ZON COMPLETE 06/21/2018 06/21/2018
Note: Released By: AMOBLEY
BLD COMPLETE 06/14/2018 06/21/2018
Note: Released By: JHINDMAN
BLD COMPLETE 04/26/2018 05/01/2018
Note: Released By: JHINDMAN
ELEC COMPLETE 04/26/2018 04/27/2018
Note: Released By: DREWIS
ENGIN1 COMPLETE 04/26/2018 04/27/2018
Note: Released By: TBAKER
MECH COMPLETE 04/26/2018 05/02/2018
Note: Released By: FREODICA
PLUM COMPLETE 04/26/2018 05/02/2018
Note: Released By: FREODICA
SW1 COMPLETE 04/26/2018 04/27/2018
Note: Released By: DREWIS
UD1 COMPLETE 04/26/2018 05/03/2018
Note: Released By: MBACON This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
ZON COMPLETE 04/26/2018 04/27/2018
Note: Released By: AMOBLEY

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 02/06/2019
REINSPECTION FEE ¤40.00 02/06/2019
REINSPECTION FEE ¤40.00 01/10/2019
REINSPECTION FEE ¤40.00 01/10/2019
REINSPECTION FEE ¤40.00 01/10/2019
REINSPECTION FEE ¤40.00 01/10/2019
REINSPECTION FEE ¤40.00 01/10/2019
REINSPECTION FEE ¤40.00 01/10/2019
REVISION ¤40.00 01/10/2019
REVISION ¤40.00 01/10/2019
SITE PLAN 20 ¤20.00 05/03/2018
SURCHARGE FS 533.721 ¤31.05 05/03/2018
SURCHARGE - FS 468.631 ¤46.58 05/03/2018
STORM WATER PERMIT FEES ¤80.00 05/03/2018
3% TRANS IMPACT FEE CREDIT (¤93.74) 05/03/2018
ADMIN FEE ¤20.00 05/03/2018
ELECTRIC FEE ¤472.20 05/03/2018
3% FIRE IMPACT FEE CREDIT (¤6.56) 05/03/2018
IMPACT FEE FIRE NONRESIDENTIAL ¤218.79 05/03/2018
IMPACT FEE PARKS ¤849.24 05/03/2018
IMPACT FEE SCHOOL ¤3,600.00 05/03/2018
IMPACT FEE TRANSPORTATION ¤3,124.67 05/03/2018
MECHANICAL FEE ¤472.20 05/03/2018
3% PARKS IMPACT FEE CREDIT (¤25.48) 05/03/2018
PLAN CHECK FEE ¤274.80 05/03/2018
PLUMBING FEE ¤472.20 05/03/2018
NEW RESIDENTIAL INSPECTIONS ¤1,374.00 05/03/2018
Fees Total Due: ¤0.00 Total Paid: ¤11,329.95