Permit #2018041451
Permit Details
Status: COED
| Parcel Id: 07-11-31-7015-00030-0420 |
| CONDITIONED SPACE: 2518 sqft |
| OPENED PORCH (WITH ROOF) : 72 sqft |
| OPENED PORCH (WITH ROOF) : 298 sqft |
| GARAGE: 495 sqft |
| Total Square Footage: 3383 sqft |
| Block: 00030 |
| Subdivision: 2127 - COUNTRY CLUB HARBOR |
| Job Phone: (386)446-5161 |
| Location Address: 36 CHEROKEE CT W |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/15/2018 |
| NOC: RECORDED |
| Applicant name: HUGO A CAMACHO |
| Owner: SOUSA, CARMEN |
|
Address 11536 JORDANUS DRIVE RALEIGH, NC 27617 |
| Lot: 0420 |
| Contracted Stated Job Value: ¤350,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
IDEAL HOMES AT PALM COAST, INC.
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO BOX 353639 PALM COAST, FL 32137 |
CBC1250774 (Exp: 08/31/2026) | (386)446-5161 | (386)447-0238 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
THOMAS A REGULA
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
11320 PHILLIPS PKWY DRIVE E JACKSONVILLE, FL 32256 |
CMC1250075 (Exp: 08/31/2026) | 904-278-0339 | 904-278-0366 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
JOANNA S REELEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
2 MARKET PLACE D PALM COAST, FL 32137 |
CCC1327485 (Exp: 08/31/2020) | 386-445-7945 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/17/2019 | FINAL APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 05/16/2019 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 1. NEED ALARMS ON DOORS OR DEVICES IN BOTH BODIES OF WATER (POOL IS FULL) 2. EXHAUST VENTS TERMINATE 3 feet FROM OPENINGS FBC.R.M1506 CANNOT TERMINATE WITHIN 3 feet OF OPENINGS (OPERABLE OR NON-OPERABLE) 3. TEST CAPS ON FUTURE DWV…. P3005.1.5 PROVISIONS FOR FUTURE FIXTURES. REPLACE TEST CAPS WITH PERMANENT PLUG OR CAP FITTING (SCHEDULE 40) (NOT A TEST CAP) (SUMMER KITCHEN) 4. MOCP RATING NOT MATCHING BREAKERS MFBC 1303 (A/C CALLS FOR 40,... 60 IS INSTALLED) | |||
| ROW - DRAINAGE | 05/08/2019 | APPROVED | RGROSS |
| ROW - STORMWATER FINAL | 05/08/2019 | APPROVED | RGROSS |
| ROW - FINAL INSPECTION | 05/08/2019 | APPROVED | RGROSS |
| U -UTILITY RESIDENTIAL FINAL | 05/08/2019 | FINAL APPROVED | JNICHOLS |
| FINAL SURVEY (OFFICE USE ONLY) | 05/06/2019 | APPROVED | JHINDMAN |
| ROW- PRE-APRON (PRE-POUR) | 04/05/2019 | APPROVED - AS NOTED | RGROSS |
| Note: A COMPLETE CONCRETE UNDER BASE WAS POURED ON THE PARTIAL. READY FOR PAVERS. | |||
| ELECTRIC - EARLY POWER | 04/03/2019 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO SUSAN FPL RELEASED POWER 3:50 | |||
| ROW- PAVER RESTRAINTS | 03/22/2019 | APPROVED - AS NOTED | RGROSS |
| Note: INSPECTED DURING THE PRE POUR. | |||
| ROW- PRE-APRON (PRE-POUR) | 03/22/2019 | PARTIALLY APPROVED | RGROSS |
| Note: APPROVED FOR THE CONCRETE OVER PIPE, APRON AND PAVER RESTRAINTS POUR. PAVER DRIVEWAY | |||
| U - SEWER TIE IN | 03/07/2019 | APPROVED | JGIBSON |
| GRAVITY SEWER TEST | 03/07/2019 | APPROVED | JGIBSON |
| INSULATION | 02/12/2019 | APPROVED | WMILLER |
| Note: APPROVED | |||
| INSULATION | 02/11/2019 | Disapproved -FEE REQUIRED | WMILLER |
| Note: NEED INSULATION CERTIFICATE ON SITE AT TIME OF INSPECTION | |||
| ALL ROUGH | 02/07/2019 | APPROVED | WMILLER |
| Note: approved | |||
| ALL ROUGH | 02/06/2019 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 1. SER SUPPORT STRAPPING FBC R E 3605.7 AND NEC.334 NEEDS TO BE STRAPPED PER NEC 334 (WITHIN 12 INCHES AND AT 30 INCH ENTERVALS ) 2. ALL METAL BOXES SHALL BE GROUNDED R,E 3905.2 AND NEC.314.4 (LOW VOLTAGE CONSOLE) 3. MISSING BOND AT JACUZZI TUB... WHIRLPOOL PUMPS BONDING 680.62 (B) (JACUZZI TUB NEEDS TO BE BONDED TO METAL PIPES AT FAUCET, REMOVE GROUND TO OUTLET) 4. FIREBLOCKING R302.11 1-6 (ARCH AREA NEAR MASTER) | |||
| ALL ROUGH | 02/04/2019 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 1. SER SUPPORT STRAPPING FBC R E 3605.7 AND NEC.334 NEEDS TO BE STRAPPED PER NEC 334 (WITHIN 12 INCHES AND AT 30 INCH ENTERVALS ) 2. NAIL PLATES ON ELECTRIC FBC E3802.1 (table), AND 3802.3.2 OR NEC 334.15 b. (RESPECTIVELY) protection from physical damage. (SER AGAINST UNDERSIDE OF ROOF DECKING 3. ALL METAL BOXES SHALL BE GROUNDED R,E 3905.2 AND NEC.314.4 4. MISSING BOND AT JACUZZI TUB... WHIRLPOOL PUMPS BONDING 680.62 (B) 5. NEED TO PHASE OUT HOT CONDUCTORS IN PANEL BOX. NEC.210.5(C).. 6. FIREBLOCKING R302.11 1-6 (ARCH AREA NEAR MASTER) | |||
| LATH/BRICK/ WATER BARRIER | 01/29/2019 | APPROVED | WMILLER |
| Note: approved | |||
| ROOF VALLEY & METAL | 12/04/2018 | APPROVED | WMILLER |
| Note: APPROVED | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/03/2018 | APPROVED | WMILLER |
| Note: APPROVED | |||
| ELECTRIC-TUG | 11/13/2018 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO SUSAN FPL RELEASED TUG 4:00 | |||
| ELECTRIC-TUG | 10/31/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL | |||
| TIE BEAM / LINTEL | 10/29/2018 | APPROVED | WMILLER |
| Note: APPROVED | |||
| FOUND SURVEY APPROVED (OFFICE) | 10/26/2018 | APPROVED | DREWIS |
| MONOLITHIC SLAB | 10/02/2018 | APPROVED | CMINI |
| PLUMBING 1ST ROUGH UNDERGROUND | 09/24/2018 | APPROVED | JGIBSON |
| RETAINING WALL | 08/09/2018 | APPROVED | WMILLER |
| RETAINING WALL FOUNDATION | 07/20/2018 | APPROVED | WMILLER |
Review History
| Department | Status | Date In | Date Out |
| PLFM | COMPLETE | 05/06/2019 | 05/06/2019 |
| Note: Released By: JMYERS The Final elevation certificate has been accepted. | |||
| SW1 | COMPLETE | 05/03/2019 | 05/06/2019 |
| Note: Released By: JHINDMAN final | |||
| ZON | COMPLETE | 04/09/2019 | 04/09/2019 |
| Note: Released By: AMOBLEY | |||
| PLFM | COMPLETE | 03/20/2019 | 03/20/2019 |
| Note: Released By: MDEFREITAS | |||
| ZON | COMPLETE | 03/15/2019 | 03/18/2019 |
| Note: Released By: AMOBLEY | |||
| PLFM | HOLD | 03/15/2019 | 03/15/2019 |
| Note: Held By: JMYERS Based on Site Plan submitted on 3/15/19 the structure does fall within the Special Flood Hazard Area. Due to the late stage of construction, only a Final Elevation Certificate will be required. | |||
| ENGIN1 | COMPLETE | 03/08/2019 | 03/12/2019 |
| Note: Released By: TBAKER | |||
| SW1 | COMPLETE | 03/08/2019 | 03/15/2019 |
| Note: Released By: JHINDMAN | |||
| UD1 | COMPLETE | 03/08/2019 | 03/13/2019 |
| Note: Released By: AHALL Gravity Sewer new homes This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. The NFPA Clear Zone distance there can be no obstacles in front of the Hydrant and 3.0’ on both sides and 4’ behind. | |||
| ZON | HOLD | 03/08/2019 | 03/08/2019 |
| Note: Held By: AMOBLEY Revision Site plan survey should have the updated flood information on it. | |||
| PLFM | HOLD | 03/08/2019 | 03/08/2019 |
| Note: Held By: JMYERS Due to the FEMA FIRM change on 6/6/18, there is now a Special Flood Hazard Area on this property. Please provide an updated Site Plan that shows the extent of the Special Flood Hazard Area. If the structure should fall within the Special Flood Hazard Area, a Final elevation certificate will be required due to the building already being under construction. | |||
| ELEC | COMPLETE | 01/16/2019 | 01/24/2019 |
| Note: Released By: JHINDMAN | |||
| ELEC | CANCEL | 11/28/2018 | 11/30/2018 |
| Note: No electrical revision | |||
| BLD | COMPLETE | 11/28/2018 | 11/30/2018 |
| Note: Released By: JHINDMAN | |||
| ELEC | COMPLETE | 11/06/2018 | 11/09/2018 |
| Note: Released By: DREWIS | |||
| SW1 | COMPLETE | 10/23/2018 | 10/26/2018 |
| Note: Released By: DREWIS | |||
| BLD | COMPLETE | 06/20/2018 | 06/26/2018 |
| Note: Released By: JHINDMAN Released By: JHINDMAN | |||
| ENGIN1 | COMPLETE | 06/20/2018 | 06/21/2018 |
| Note: Released By: TBAKER | |||
| SW1 | COMPLETE | 06/20/2018 | 06/25/2018 |
| Note: Released By: DREWIS | |||
| UD1 | COMPLETE | 06/20/2018 | 06/26/2018 |
| Note: Released By: MBACON This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. | |||
| ZON | COMPLETE | 06/20/2018 | 06/20/2018 |
| Note: Released By: AMOBLEY | |||
| ZON | COMPLETE | 05/09/2018 | 05/09/2018 |
| Note: Released By: AMOBLEY | |||
| SWALE | COMPLETE | 05/09/2018 | 05/21/2018 |
| Note: Released By: TBAKER | |||
| MECH | COMPLETE | 05/09/2018 | 05/14/2018 |
| Note: Released By: FREODICA | |||
| BLD | COMPLETE | 05/01/2018 | 05/03/2018 |
| Note: Released By: JHINDMAN | |||
| ELEC | COMPLETE | 05/01/2018 | 05/02/2018 |
| Note: Released By: DREWIS | |||
| ENGIN1 | COMPLETE | 05/01/2018 | 05/03/2018 |
| Note: Released By: TBAKER | |||
| MECH | HOLD | 05/01/2018 | 05/04/2018 |
| Note: Held By: FREODICA Building orientation shown on energy calculations does not match with site plan. Coordinate to comply with FBCEC 6the ed. R403.7.1. F.Reodica -386-986-4734. | |||
| PLUM | COMPLETE | 05/01/2018 | 05/04/2018 |
| Note: Released By: FREODICA | |||
| SW1 | COMPLETE | 05/01/2018 | 05/02/2018 |
| Note: Released By: DREWIS | |||
| UD1 | COMPLETE | 05/01/2018 | 05/07/2018 |
| Note: Released By: MBACON This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. | |||
| ZON | HOLD | 05/01/2018 | 05/01/2018 |
| Note: Held By: AMOBLEY Please provide a color swatch of body color Row utilization agreement is not notarized correctly. Please provide a corrected original copy |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REVISION | ¤40.00 | 05/17/2019 |
| REVISION | ¤40.00 | 05/17/2019 |
| REVISION | ¤40.00 | 05/17/2019 |
| REVISION | ¤40.00 | 05/17/2019 |
| REVISION | ¤40.00 | 05/17/2019 |
| REINSPECTION FEE | ¤40.00 | 05/17/2019 |
| REINSPECTION FEE | ¤40.00 | 05/17/2019 |
| REINSPECTION FEE | ¤40.00 | 05/17/2019 |
| REINSPECTION FEE | ¤40.00 | 05/17/2019 |
| REINSPECTION FEE | ¤40.00 | 05/17/2019 |
| NEW RESIDENTIAL INSPECTIONS | ¤700.00 | 05/15/2018 |
| SITE PLAN 20 | ¤20.00 | 05/15/2018 |
| SURCHARGE FS 533.721 | ¤16.90 | 05/15/2018 |
| SURCHARGE - FS 468.631 | ¤25.35 | 05/15/2018 |
| STORM WATER PERMIT FEES | ¤80.00 | 05/15/2018 |
| 3% TRANS IMPACT FEE CREDIT | (¤93.74) | 05/15/2018 |
| ADMIN FEE | ¤20.00 | 05/15/2018 |
| ELECTRIC FEE | ¤270.00 | 05/15/2018 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.56) | 05/15/2018 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤218.79 | 05/15/2018 |
| IMPACT FEE PARKS | ¤849.24 | 05/15/2018 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 05/15/2018 |
| RECORDING FEE REIMBURSE DOC | ¤52.50 | 05/15/2018 |
| IMPACT FEE TRANSPORTATION | ¤3,124.67 | 05/15/2018 |
| MECHANICAL FEE | ¤270.00 | 05/15/2018 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 05/15/2018 |
| PLAN CHECK FEE | ¤140.00 | 05/15/2018 |
| PLUMBING FEE | ¤270.00 | 05/15/2018 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,931.67 |