I want to search for...

Permit #2018050851

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7037-00290-0200
GARAGE: 1162 sqft
CONDITIONED SPACE: 935 sqft
Total Square Footage: 2097 sqft
Block: 00290
Subdivision: -
Job Phone: 386-931-1905
Location Address: 64 LA MANCHA DR
Type: BA - BUILDING ADDITION
Issue Date: 08/24/2018
NOC: RECORDED
Applicant name: RICHARD JAMES SMITH
Owner: MILOGRANO ANITA L & JOHN R DAVIS W&H

Address

64 LAMANCHA DRIVE

PALM COAST, FL 32137

Lot: 0200
Contracted Stated Job Value: ¤170,000.00
Job Description: ADDING ROOM & ATTACHED GARAGE, REPLACING WINDOWS & DOORS
Type: CN

Contractor

HAMMOCK COMMUNITIES INC
Status Location Address State License Number Phone
INACTIVE

725 NORTH OCEANSHORE BLVD

FLAGLER BEACH, FL 32136

CGC1516033 (Exp: 08/31/2026) 386-693-4947

Sub Contractors

KENNETH J LEANDRO SR
Status Location Address State License Number Phone
CANCEL

115 N 2ND STREET

FLAGLER BEACH, FL 32136

ER13015308 (Exp: 08/31/2022) 386-569-4139
MICHAEL ANTONIO QUINONES
Status Location Address State License Number Phone
CANCEL

2948 1ST ST

ST AUGUSTINE, FL 32084

CFC1429017 (Exp: 08/31/2022) 904-735-5097
JOSE E ORTIZ JR
Status Location Address Mailing Address State License Number Phone
CANCEL

4601 E MOODY BLVD

BUNNELL, FL 32110

SUITE B7

BUNNELL, FL 32110

RC29027619 (Exp: 08/31/2023) 386-503-6922
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 08/30/2019 FINAL APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 08/29/2019 Disapproved -FEE REQUIRED JCOLASANTI
Note: GFCI’S NEEDED, 210.8-A, ALL 120 VOLT SINGLE PHASE 15 AND 20 AMP RECEPTICLES INSTALLED IN LOCATIONS SPECIFIED IN 1 TROUGH 8 SHALL HAVE GFCI PROTECTION (1. BATHROOMS,2. GARAGES, 3. OUT DOORS, 4. CRAWL SPACES, 5. UNFINISHED BASEMENTS, 6.KITCHENS, 7, SINKS-LOCATED IN AREAS OTHER THAN KITCHENS WITHIN 6ft OF THE EDGE OF THE SINK, 8 BOAT-HOUSES) (garage wall adjacent to bathroom gfi outlets not tripping and gfi plug hot/nue revervesd)
U -UTILITY RESIDENTIAL FINAL 08/26/2019 FINAL APPROVED JHARDING
FINAL SURVEY (OFFICE USE ONLY) 08/23/2019 APPROVED KHOWELL
ROW - FINAL APRON (AFTER POUR) 07/08/2019 APPROVED RGROSS
LATH/BRICK/ WATER BARRIER 05/16/2019 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
LATH/BRICK/ WATER BARRIER 05/03/2019 Disapproved - NO FEE MWILLIAMS
Note: THIS IS A REINSPECTION Prior inspection failure called for wire lathe on dormer above garage. No lathe present at this time
LATH/BRICK/ WATER BARRIER 04/04/2019 Disapproved -FEE REQUIRED JCOLASANTI
Note: need to install lathe at doormer area above garage doors.
ROW- PRE-APRON (PRE-POUR) 03/28/2019 APPROVED RGROSS
Note: READY TO POUR
ROW- PRE-APRON (PRE-POUR) 03/27/2019 Disapproved -FEE REQUIRED RGROSS
Note: APRON FULL OF WATER. NOT A MINIMUM OF 4" DEPTH THROUGHT THE POUR BEYOND THE ROW. SEE PAINT MARKS ON GROUND.
INSULATION 03/27/2019 APPROVED JCOLASANTI
ALL ROUGH 03/21/2019 APPROVED - AS NOTED JCOLASANTI
Note: need to inspect windows in existing residence...need nail plats at dryer vent (wrong size) and bathroom marked orange, ( check at insulation)
ALL ROUGH 03/19/2019 Disapproved -FEE REQUIRED JCOLASANTI
Note: MEMBERS LESS TH 1 ½” FROM NEAREST EDGE OF THE MEMBER, THE PIPE SHALL BE PROTECTED BY 2” STEEL SHIELD PLATES FBC..P2603.2.1 (Waste pipes check all)...check electircal penetrations 1 one quarter edge of hole to end of framing member...NEED TO SEAL EXHAUST BATH DUCT AT ROOF WITH MASTIC..FBC.. M1601.4.1.7...not sure if house windows are on seperate permit, need to inspect windows in house if same permit
ROW- PRE-APRON (PRE-POUR) 03/15/2019 Disapproved -FEE REQUIRED KHOWELL
Note: 1. 4"THICK CONCRETE MINIMUM REQUIRED ABOVE THE R.O.W. 2. DRIVEWAY IS FORMED WIDER THEN THE APPROVED SITE PLAN EITHER GET A REVISION OR REFORM TO APPROVED SITE PLAN. 3. DID NOT SHOOT CULVERT BECAUSE OF FORMS BEING WIDER
ROW- PROJECT STATUS 02/13/2019 APPROVED CTROHA
Note: met with contractor and site prep guys to discuss grading issues I recommended to them they follow their proposed plan or get a revision
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/22/2019 APPROVED JCOLASANTI
TIE BEAM / LINTEL 12/04/2018 APPROVED JCOLASANTI
TIE BEAM / LINTEL 11/30/2018 Disapproved -FEE REQUIRED JCOLASANTI
Note: missng steel in cell, missing down rod (orange paint) and need to epoxy lintel steel into existing block per detail 10 all marked on plan FBC 802
FOUND SURVEY APPROVED (OFFICE) 11/29/2018 APPROVED DREWIS
MONOLITHIC SLAB 10/16/2018 APPROVED - AS NOTED JCOLASANTI
Note: need inspection set of plans together for remainder of inspections
PLUMBING 1ST ROUGH UNDERGROUND 10/03/2018 APPROVED - AS NOTED JGIBSON
Note: MAIN SEWER TRUNK LINE P-2603.4 PIPES PASSING THROUGH FOUNDATION WALLS MUST BE ''2'' PIPE DIAMETERS LARGER THAN PIPE PASSING THROUGH OR A RELIEVING ARCH OVER PIPE, WILL CHECK AT MONOLITHIC SLAB INSPECTION

Review History

Department Status Date In Date Out
ZON COMPLETE 08/28/2019 08/28/2019
Note: Released By: AMOBLEY
ZON HOLD 05/20/2019 05/20/2019
Note: Held By: TDOAK Commercial garage doors not allowed on single family residence. Only standard residential garage doors are permitted.
BLD COMPLETE 05/13/2019 05/20/2019
Note: Released By: RLEE
ZON COMPLETE 03/18/2019 03/19/2019
Note: Released By: AMOBLEY
SW1 COMPLETE 03/18/2019 03/25/2019
Note: Released By: JHINDMAN
ENGIN1 COMPLETE 03/18/2019 03/25/2019
Note: Released By: TBAKER
UD1 COMPLETE 03/18/2019 03/25/2019
Note: Released By: AHALL All Concrete, Driveways, Pavers, Pools / Sidewalks ETC. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. The NFPA Clear Zone distance there can be no obstacles in front of the Hydrant and 7.5’ on the sides or 4’ behind.
ELEC COMPLETE 03/11/2019 03/18/2019
Note: Released By: JHINDMAN
ENGIN1 COMPLETE 02/12/2019 02/12/2019
Note: Released By: TBAKER
SWALE COMPLETE 02/12/2019 02/14/2019
Note: Released By: TBAKER
SW1 COMPLETE 11/27/2018 11/29/2018
Note: Released By: DREWIS
MECH COMPLETE 08/13/2018 08/13/2018
Note: Released By: FREODICA
MECH HOLD 08/03/2018 08/03/2018
Note: Held By: FREODICA Review comments due to changes in energy calcualtions and plans: 1. Provide signature of owner/agent on Florida energy code compliance certification per FBCEC 6th ed. R405.3. 2. Provide signature of builder on energy performance level (EPL) display card per FBC 6th ed. R401.3 3. Provide signature and license number of hvac contractor on hvac plan per FBC 6th ed. 105.3.1.2. 4. Provide balanced return air from Florida room per FBCR 6th ed. M1602.3. 5. Provide complete information on heating/cooling equipment summary for selected 3.5.- ton hvac units per FBCEC 6th ed. R403.7. F.Reodica -386-986-4734.
BLD COMPLETE 08/02/2018 08/03/2018
Note: Released By: JHINDMAN
ZON COMPLETE 08/01/2018 08/02/2018
Note: Released By: AMOBLEY
PLUM COMPLETE 08/01/2018 08/03/2018
Note: Released By: FREODICA
ZON HOLD 06/19/2018 06/20/2018
Note: Held By: AMOBLEY If not maintaining the original garage. The garage door and driveway will need to be removed and will need to provide a floor plan showing what the current garage will be enclosed to. If structure has a garage door it can not be conditioned space it must be a unconditioned garage space Garages shall not exceed 50 percent of the total living area of the principal dwelling unit Revised plans still show that the proposed garage plate height exceeds the height of the first story of the principal dwelling unit. City utilities have to release easement before permit can be released. Also an agreement will be done and have to be signed and recorded.
ELEC COMPLETE 06/19/2018 06/22/2018
Note: Released By: DREWIS Held By: DREWIS Provide a plan with darker building addition outline. Daniel Rewis 986-4736
PLUM HOLD 06/19/2018 06/22/2018
Note: Held By: FREODICA 1. Provide vent at the shower to comply with FBCR 6th ed. P3108.2.1 2. Laundry tub and washer vent shall comply with FBCR 6th P3104.4. F.Reodica -386-986-4734.
BLD COMPLETE 05/17/2018 05/21/2018
Note: Released By: JHINDMAN
SW1 COMPLETE 05/17/2018 05/21/2018
Note: Released By: DREWIS
ZON HOLD 05/17/2018 05/21/2018
Note: Held By: AMOBLEY Please provide a floor plan showing what the current garage will be enclosed to. All driveways must lead to a garage so current driveway will have to be removed. Garages shall not exceed the height of the first story of the principal dwelling unit. City utilities have to release easement before permit can be released. Also an agreement will be done and have to be signed and recorded.
ELEC HOLD 05/17/2018 05/21/2018
Note: Held By: DREWIS Provide plan signed/sealed by the designing engineer or the signature/license number of the electrical contractor, FBC 6th ed 107.1 Code to be referenced is the NEC 2014, FBC 6th ed. Daniel Rewis 986-4736
MECH COMPLETE 05/17/2018 05/21/2018
Note: Released By: FREODICA
PLUM HOLD 05/17/2018 05/22/2018
Note: Held By: FREODICA Provide sanitary riser diagram either prepared by design professional or a plumbing contractor with signature and licensse number per FBC 6th ed. 107.1. F.Reodica -386-986-4734.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 08/29/2019
REVISION ¤40.00 08/26/2019
CONTRACTOR CHANGE ¤40.00 08/26/2019
CONTRACTOR CHANGE ¤40.00 08/26/2019
REINSPECTION FEE ¤40.00 08/26/2019
REINSPECTION FEE ¤40.00 08/26/2019
REINSPECTION FEE ¤40.00 08/26/2019
REINSPECTION FEE ¤40.00 08/26/2019
REINSPECTION FEE ¤40.00 08/26/2019
ELECTRIC FEE ¤162.00 08/24/2018
RECORDING FEE REIMBURSE DOC ¤35.50 08/24/2018
MECHANICAL FEE ¤162.00 08/24/2018
PLAN CHECK FEE ¤68.00 08/24/2018
PLUMBING FEE ¤162.00 08/24/2018
SITE PLAN 20 ¤20.00 08/24/2018
SURCHARGE FS 533.721 ¤6.62 08/24/2018
SURCHARGE - FS 468.631 ¤9.93 08/24/2018
STORM WATER PERMIT FEES ¤80.00 08/24/2018
REMODEL/ADDITION/ACCES INSPECT ¤68.00 08/24/2018
ADMIN FEE ¤20.00 08/24/2018
Fees Total Due: ¤0.00 Total Paid: ¤1,154.05