I want to search for...

Permit #2018060042

Permit Details

Status: CANCEL

Parcel Id: 07-11-31-7014-00030-0410
Block: 00030
Subdivision: 2202 - SECTION 14-COUNTRY CLUB COVE
Location Address: 29 CIMMARON DR
Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION
NOC: NO DOCUMENTATION
Applicant name: MICHAEL JORDAN HUBER
Owner: SWAIN GWENDOLYN E & JACKIE R W&H

Address

29 CIMMARON DR

PALM COAST, FL 32137

Lot: 0410
Contracted Stated Job Value: ¤9,000.00
Job Description: CONVERT BACK PORCH TO SUNROOM
Type: CN

Contractor

HUBCO BUILDING & REMODELING, LLC
Status Location Address State License Number Phone
ACTIVE

2553 GREENTREE STREET

BUNNELL, FL 32110

CRC1330947 (Exp: 08/31/2026) 386-283-1059

Sub Contractors

RICHARD PAUL NEUMANN
Status Location Address State License Number Phone Fax
ACTIVE

135 BEAU RIVAGE DR.

ORMOND BEACH, FL 32176

EC13007384 (Exp: 08/31/2026) 386-441-4212 386-441-6889
JUAN EUGENIO CAMPELO
Status Location Address State License Number Phone Fax
INACTIVE

114 ALLGOOD CIRCLE SUITE #101

ST AUGUSTINE, FL 32086

CAC1813797 (Exp: 08/31/2026) 904-824-4275 904-824-4614

Inspection History

Type Request Date Result Inspector
ALL ROUGH
ROOF SHEATHING / BRACES/TIES/DOWN CELL
INSULATION
BLD - BUILDING FINAL

Review History

Department Status Date In Date Out
ZON COMPLETE 06/29/2018 06/29/2018
Note: Released By: AMOBLEY
BLD HOLD 06/29/2018 07/05/2018
Note: Held By: JHINDMAN 1.; Provide a signed and sealed revised plan. 6th ed. FBC 107.1 J. Hindman 986-3784.
MECH HOLD 06/29/2018 07/05/2018
Note: Held By: FREODICA Repeat comment item 3: he proposed enclosure of existing space is not classified as a sunroom by definition per FBCR 6th edition. It is considerd as a building addition and habitable space which requires heating or cooling. Please provide the following: 1. Hvac contractor per FS 489, 2. Hvac plan with signature and license number of an hvac contractor per FBC 6th ed. 105.3.1.2. 3. Energy calcuations/equipmen sizing calc. per FBCEC 6th ed. 502.1.
ELEC COMPLETE 06/11/2018 06/12/2018
Note: Released By: DREWIS
MECH HOLD 06/11/2018 06/15/2018
Note: Held By: FREODICA The proposed enclosure of existing space is not classified as a sunroom by definition per FBCR 6th edition. It is considerd as a building addition and habitable space which requires heating or cooling. Please provide the following: 1. Hvac contractor per FS 489, 2. Hvac plan with signature and license number of an hvac contractor per FBC 6th ed. 105.3.1.2. 3. Energy calcuations/equipmen sizing calc. per FBCEC 6th ed. 502.1.
BLD HOLD 06/04/2018 06/11/2018
Note: Held By: JHINDMAN 1. Identify the sunroom category type per the 6th edition florida Building Code Residential r301.2.1.1.1. J. Hindman 986-3784.
ZON HOLD 06/04/2018 06/04/2018
Note: Held By: AMOBLEY Please provide site plan showing existing porch being converted
MECH CANCEL
BLD CANCEL

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤40.00