I want to search for...
Permit #2018060250
Permit Details
Status: COED
| Parcel Id: 41-11-31-0000-01050-0000 |
| Block: 01050 |
| Subdivision: - |
| Job Phone: 386-237-0328 |
| Location Address: 303 PALM COAST PKWY |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 09/24/2018 |
| NOC: RECORDED |
| Applicant name: JAMES JOSEPH ALBANO |
| Owner: ST MARK BY THE SEA LUTHERAN CHURCH OF PALM COAST F |
|
Address 303 PALM COAST PKWY NE PALM COAST, FL 32137 |
| Lot: 0000 |
| Contracted Stated Job Value: ¤125,000.00 |
| Job Description: KITCHEN RENOVATION |
| Type: CN |
Contractor
ALBANO DESIGNS STUDIOS, INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
82 LEE DR PALM COAST, FL 32137 |
CBC050078 (Exp: 08/31/2026) | 386-237-0328 |
Sub Contractors
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
KURT A UMBACH
| Status | Location Address | State License Number | Phone | Fax |
| HOLD |
110 Foster Lane Palm Coast, FL 32137 |
EC13003356 (Exp: 08/31/2020) | (386) 446-3616 | (386)446-3548 |
KEN DEPRINZIO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
325 WALKER STREET HOLLY HILL, FL 32117 |
11351 (Exp: 08/31/2026) | 386-672-8494 | 386-673-7856 |
SHAWN MICHAEL HISS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1315 LPGA BLVD HOLLY HILL, FL 32117 |
CAC1813585 (Exp: 08/31/2026) | (386)672-8688 |
Inspection History
| Type | Request Date | Result | Inspector |
| GAS FINAL | 04/24/2019 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | 03/15/2019 | APPROVED | JHINDMAN |
| BUILDING FINAL | 03/14/2019 | APPROVED | MWILLIAMS |
| ELECTRIC FINAL | 03/14/2019 | APPROVED | RMARTIN |
| GAS ROUGH | 03/14/2019 | APPROVED - AS NOTED | JGIBSON |
| Note: PRESSURE WAS GOOD WATER HEATER WORKING | |||
| GAS FINAL | 03/14/2019 | Disapproved - NO FEE | JGIBSON |
| Note: NEED TO HAVE SAFETY BALLARDS IN PLACE PER CODE AND PLANS | |||
| U - UTILITY COMMERCIAL FINAL | 02/12/2019 | FINAL APPROVED | JNICHOLS |
| U-GREASE INTERCEPTOR PRE-INSTALLATION | 02/12/2019 | APPROVED | JNICHOLS |
| U-GREASE INTERCEPTOR INSTALLED/PLUMBED | 02/11/2019 | APPROVED | JNICHOLS |
| U-GREASE INTERCEPTOR FLOW/DYE TESTED | 02/11/2019 | APPROVED | JNICHOLS |
| GAS ROUGH | 02/11/2019 | Disapproved - NO FEE | JHINDMAN |
| Note: provide test guage on line.6th ed. FBC FG 406 | |||
| ABOVE CEILING | 02/11/2019 | APPROVED | JHINDMAN |
| PLUMBING FINAL | 02/11/2019 | APPROVED - AS NOTED | JHINDMAN |
| Note: check hot water at gas final | |||
| HVAC FINAL | 02/11/2019 | APPROVED | JHINDMAN |
| PLUMBING 2ND ROUGH | 10/31/2018 | APPROVED | JGIBSON |
| HVAC ROUGH | 10/30/2018 | APPROVED | JHINDMAN |
| PLUMBING 2ND ROUGH | 10/30/2018 | CANCELLED BY APPLICANT | JGIBSON |
| Note: CONTRACTOR CALL TO CANCEAL | |||
| GAS ROUGH | 10/30/2018 | PARTIALLY APPROVED | JGIBSON |
| Note: THIS WAS FOR INSIDE LINES ONLY, NEED UNDERGROUND FROM TANK TO BUILDING | |||
| ELECTRIC 2ND ROUGH | 10/26/2018 | APPROVED - AS NOTED | RMARTIN |
| Note: NEED REVISION BY ELECTRIC FINAL ON ADDED AND DELETED SWITCHES/OUTLETS | |||
| FRAMING | 10/24/2018 | APPROVED | WMILLER |
| Note: APPROVED | |||
| ELECTRIC 2ND ROUGH | 10/23/2018 | PARTIALLY APPROVED | RMARTIN |
| Note: WALLS ONLY | |||
| PLUMBING 1ST ROUGH | 10/23/2018 | APPROVED - AS NOTED | JGIBSON |
| Note: THIS WAS FOR SANITARY AND FOR GREASE LINES PER PLAN AND INDIRECT SPECIAL WASTE CODED 802.1.1 |
Review History
| Department | Status | Date In | Date Out |
| FI1 | COMPLETE | 08/16/2018 | 08/28/2018 |
| Note: Released By: JHINDMAN | |||
| MECH | COMPLETE | 08/16/2018 | 08/16/2018 |
| Note: Released By: FREODICA Separate hood permit will be applied by climate control per contractor's note on correction form. | |||
| PLUM | COMPLETE | 08/16/2018 | 08/16/2018 |
| Note: Released By: FREODICA | |||
| BLD | COMPLETE | 07/10/2018 | 07/19/2018 |
| Note: Released By: JHINDMAN | |||
| FI1 | HOLD | 07/10/2018 | 07/18/2018 |
| Note: Held By: DREWIS Cannot release until additional permits applied for. Daniel Rewis 986-4736 | |||
| MECH | HOLD | 07/10/2018 | 07/20/2018 |
| Note: Held By: FREODICA Repaet comment for item 1: 1. Provide existing and proposed hvac plan either prepared by design professional or an hvac contractor with signature and license number per FBC 6th ed.105.3.1.2. C503,1/C403.2.1. F.REodica -386-986-4734. | |||
| PLUM | HOLD | 07/10/2018 | 07/20/2018 |
| Note: Held By: FREODICA 1, Plumbing riser diagram shows (2) hand sinks but floor plan shows only (1) hand sink. Coordinate per FBC 6th ed. 107.1 2. Provide gas riser diagram complete with pipe sizes and materials with signature and license number of gas contractor per FBCFG 6th ed. 402/403. F.Reodica -386-986-4734. | |||
| UD1 | COMPLETE | 07/10/2018 | 07/11/2018 |
| Note: Released By: CJOHNSON | |||
| BLD | HOLD | 06/06/2018 | 06/19/2018 |
| Note: Held By: JHINDMAN 1. Provide a complete scope of work with an existing fixture and floorplan. J. Hindman 986-3784.6th ed. FBC 107.2.1. | |||
| ELEC | COMPLETE | 06/06/2018 | 06/11/2018 |
| Note: Released By: DREWIS | |||
| FI1 | HOLD | 06/06/2018 | 06/19/2018 |
| Note: Held By: JHINDMAN 1. Provide a complete scope of work. If Exhaust hood is new seperate permits for the hood and suppression systems will be required. J. Hindman 986-3784. | |||
| MECH | HOLD | 06/06/2018 | 06/19/2018 |
| Note: Held By: FREODICA 1. Provide existing and proposed hvac plan either prepared by design professional or an hvac contractor with signature and license number per FBC 6th ed.105.3.1.2. 2. Provide hvac contractor per F.S. 489. 3. Provide separate permit for kitchen hood per FBC 6th ed. 107.1. 4. Provide hvac equipment sizing calculation for heating and cooling loads to verify if existing hvac units can handle the loaad or a new units are required per FBCEC 6th ed. C503,1/C403.2.1. F.REodica -386-986-4734. | |||
| PLUM | HOLD | 06/06/2018 | 06/19/2018 |
| Note: Held By: FREODICA Provide sanitary, domestic water (hot and cold) and gas riser diagrams either prepared by design professional or registered contractors (plumbing and gas) with signature and license number per FBC 6th ed. 107.3.5. F.Reodica -386-986-4734. | |||
| UD1 | HOLD | 06/06/2018 | 06/25/2018 |
| Note: Held By: CJOHNSON Revise A3 per approved grease intereceptor exemption form plan that was submitted. | |||
| ZON | COMPLETE | 06/06/2018 | 06/07/2018 |
| Note: Released By: JGONZALEZ |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN COMMERCIAL | ¤60.00 | 09/24/2018 |
| INSPECTION - COMMERCIAL ADD | ¤875.00 | 09/24/2018 |
| CONTRACTOR CHANGE | ¤40.00 | 09/24/2018 |
| ELECTRIC FEE | ¤135.00 | 09/24/2018 |
| MECHANICAL FEE | ¤135.00 | 09/24/2018 |
| PLAN CHECK FEE | ¤143.75 | 09/24/2018 |
| PLUMBING FEE | ¤135.00 | 09/24/2018 |
| SITE PLAN 20 | ¤20.00 | 09/24/2018 |
| SURCHARGE FS 533.721 | ¤6.29 | 09/24/2018 |
| SURCHARGE - FS 468.631 | ¤9.43 | 09/24/2018 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤1,559.47 |