I want to search for...

Permit #2018060837

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-00430-0090
CONDITIONED SPACE: 2208 sqft
GARAGE: 438 sqft
OPENED PORCH (WITH ROOF) : 35 sqft
OPENED PORCH (WITH ROOF) : 162 sqft
Total Square Footage: 2843 sqft
Block: 00430
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: (386) 246-6123
Location Address: 56 ESPERANTO DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/28/2018
NOC: RECORDED
Applicant name: BRIAN ANDREW GAZZOLI
Owner: CHARBONNIER, LAWRENCE K & DAWN M

Address

56 ESPERANTO DRIVE

PALM COAST, FL 32164

Lot: 0090
Contracted Stated Job Value: ¤196,310.00
Job Description: SINGLE FAMILY RESIDENTIAL
Type: CN

Contractor

SEAGATE HOMES, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

185 CYPRESS POINT PARKWAY

Palm Coast, FL 32137

SUITE 7

Palm Coast, FL 32137

CGC1518372 (Exp: 08/31/2026) 386-246-6132

Sub Contractors

RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 1963

BUNNELL, FL 32110

ES12001217 (Exp: 08/31/2026) 386-437-0607 386-437-1847
MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC052446 (Exp: 08/31/2026) 386-445-5023 386-446-4614
DENNIS GENE GAINEY
Status Location Address State License Number Phone Fax
INACTIVE

P.O. BOX 1203

Bunnell, FL 32110

CFC046004 (Exp: 08/31/2026) (386) 437-5637 386-437-3012
CHAD DAVID GRESSANI
Status Location Address State License Number Phone Fax
ACTIVE

2640 BROOKSHIRE CIRCLE

MELBOURNE, FL 32904

CCC1327235 (Exp: 08/31/2026) 321-288-6415 321-729-8997

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/26/2019 FINAL APPROVED DROCKWELL
ROW - FINAL APRON (AFTER POUR) 02/26/2019 APPROVED - AS NOTED KHOWELL
Note: SURVEY SAID THAT THE CULVERT PIPE IS OUT OF TOLERANCE, I SHOT IT AND IT IS IN TOLERANCE. I CALLED CONTRACTOR HE IS GOING TO HAVE SURVEYOR RESHOOT AND REVISE FINAL SURVEY
ROW - FINAL INSPECTION 02/26/2019 FINAL APPROVED KHOWELL
Note: CONTRACTOR IS AWARE THAT THE TOP OF BANK OF THE SWALE AT THE PROPERTY LINE IS LOWER THEN THE CENTER LINE OF THE ROAD
U -UTILITY RESIDENTIAL FINAL 02/22/2019 FINAL APPROVED MBACON
FINAL SURVEY (OFFICE USE ONLY) 02/22/2019 APPROVED JHINDMAN
ROW- PRE-APRON (PRE-POUR) 01/29/2019 APPROVED - AS NOTED KHOWELL
Note: It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist READY TO POUR upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete.
ROW- PRE-APRON (PRE-POUR) 01/25/2019 Disapproved -FEE REQUIRED KHOWELL
Note: 1. CULVERT PIPE IS PITCHED THE WRONG DIRECTION. 2. 4" OF CONCRETE REQUIRED PAST THE R.O.W. REMOVE DIRT AS REQUIRED TO GET TO 4" 3. REMOVE CONCRETE OVER POUR AT GARAGE ON THE LEFT AND RIGHT SIDES
ELECTRIC - EARLY POWER 01/22/2019 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED EARLY POWER 9:30
GRAVITY SEWER TEST 01/16/2019 APPROVED JGIBSON
U - SEWER TIE IN 01/16/2019 APPROVED JGIBSON
LATH/BRICK/ WATER BARRIER 12/13/2018 APPROVED - AS NOTED DROCKWELL
Note: Sorry Ernie
INSULATION 11/30/2018 APPROVED DROCKWELL
ALL ROUGH 11/27/2018 APPROVED DROCKWELL
ROOF VALLEY & METAL 11/19/2018 APPROVED RLEE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/13/2018 APPROVED DROCKWELL
TIE BEAM / LINTEL 10/19/2018 APPROVED DROCKWELL
FOUND SURVEY APPROVED (OFFICE) 09/19/2018 APPROVED DREWIS
MONOLITHIC SLAB 09/10/2018 APPROVED DROCKWELL
PLUMBING 1ST ROUGH UNDERGROUND 09/05/2018 APPROVED JGIBSON

Review History

Department Status Date In Date Out
SW1 COMPLETE 02/18/2019 02/22/2019
Note: Released By: JHINDMAN
SW1 COMPLETE 09/18/2018 09/19/2018
Note: Released By: DREWIS
ZON COMPLETE 06/27/2018 06/27/2018
Note: Released By: AMOBLEY
SWALE COMPLETE 06/21/2018 07/05/2018
Note: Released By: TBAKER
BLD COMPLETE 06/20/2018 06/26/2018
Note: Released By: JHINDMAN
ELEC COMPLETE 06/20/2018 06/25/2018
Note: Released By: DREWIS
ENGIN1 COMPLETE 06/20/2018 06/21/2018
Note: Released By: TBAKER
MECH COMPLETE 06/20/2018 06/26/2018
Note: Released By: FREODICA
PLUM COMPLETE 06/20/2018 06/26/2018
Note: Released By: FREODICA
SW1 COMPLETE 06/20/2018 06/25/2018
Note: Released By: DREWIS
UD1 COMPLETE 06/20/2018 06/26/2018
Note: Released By: MBACON This is a PEP Tank area. The Pep Panel will be placed 5 feet from the front corner of the building on the same side of the building as the PEP tank that is marked on the Utility marked Site plan. Make sure the electrician places the PEP power wire between 3 feet and 5 feet from the ground. The plumber should exit the slab with the sewer pipe on the side of the building the tank will be on and matching the utility marked site plan, this will reduce any piping under driveways or sidewalks and minimize the fall required. The sewer tie-in inspection must be called in the day before the tie-in. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in visual inspection so he can witness the tie-in. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
ZON HOLD 06/20/2018 06/20/2018
Note: Held By: AMOBLEY New flood maps effective 6/6/18. Surveys must have new flood information.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 02/26/2019
NEW RESIDENTIAL INSPECTIONS ¤542.00 06/28/2018
SITE PLAN 20 ¤20.00 06/28/2018
SURCHARGE FS 533.721 ¤13.58 06/28/2018
SURCHARGE - FS 468.631 ¤20.37 06/28/2018
STORM WATER PERMIT FEES ¤80.00 06/28/2018
3% TRANS IMPACT FEE CREDIT (¤48.96) 06/28/2018
ADMIN FEE ¤20.00 06/28/2018
ELECTRIC FEE ¤222.60 06/28/2018
3% FIRE IMPACT FEE CREDIT (¤6.56) 06/28/2018
IMPACT FEE FIRE NONRESIDENTIAL ¤218.79 06/28/2018
IMPACT FEE PARKS ¤849.24 06/28/2018
IMPACT FEE SCHOOL ¤3,600.00 06/28/2018
IMPACT FEE TRANSPORTATION ¤1,632.00 06/28/2018
MECHANICAL FEE ¤222.60 06/28/2018
3% PARKS IMPACT FEE CREDIT (¤25.48) 06/28/2018
PLAN CHECK FEE ¤108.40 06/28/2018
PLUMBING FEE ¤222.60 06/28/2018
Fees Total Due: ¤0.00 Total Paid: ¤7,731.18