I want to search for...

Permit #2018061245

Permit Details

Status: COED

Parcel Id: 33-11-31-3061-00010-0150
CONDITIONED SPACE: 2632 sqft
GARAGE: 705 sqft
OPENED PORCH (WITH ROOF) : 331 sqft
OPENED PORCH (WITH ROOF) : 72 sqft
Total Square Footage: 3740 sqft
Block: 00010
Subdivision: 2108 - HIDDEN LAKES PHASE II - TOSCANA
Job Phone: 863-420-2100
Location Address: 29 NEW LEATHERWOOD DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/01/2018
NOC: RECORDED
Applicant name: YUVAL BOTANSKY
Owner: APPLIED BUILDING DEVELOPMENT OF ORLANDO - PC INC

Address

131 CHADWICK DRIVE

DAVENPORT, FL 33837

Lot: 0150
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

APPLIED BUILDING DEVELOPMENT COMPANY - OAKHILLS IN
Status Location Address State License Number Phone Fax
ACTIVE

131 CHADWICK DRIVE

DAVENPORT, FL 33837

CRC1330762 (Exp: 08/31/2026) 863-420-2100 386-517-6865

Sub Contractors

YUVAL BOTANSKY
Status Location Address State License Number Phone Fax
ACTIVE

131 CHADWICK DRIVE

DAVENPORT, FL 33837

CRC1330762 (Exp: 08/31/2026) 863-420-2100 386-517-6865
JOSEPH H STRADA JR
Status Location Address State License Number Phone
CANCEL

3400 ST JOHNS PKWY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2022) 877-906-1113
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
TERRY HILE BURD
Status Location Address State License Number Phone Fax
INACTIVE

PO Box 180308

CASSELBERRY, FL 32707

CAC1814423 (Exp: 08/31/2024) (407) 831-3600 (407)831-2893
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 08/13/2019 FINAL APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION-wo in to utility to raise the water meter pit and reclaim
BLD - BUILDING FINAL 08/12/2019 APPROVED MWILLIAMS
U-CROSS CONNECTION 08/08/2019 CANCELLED BY INSPECTOR LFITZGERALD
Note: water meter pit could not be located due to being covered over by sod
ROW - FINAL APRON (AFTER POUR) 08/08/2019 APPROVED KHOWELL
ROW - STORMWATER FINAL 08/08/2019 FINAL APPROVED KHOWELL
U -UTILITY RESIDENTIAL FINAL 08/08/2019 Disapproved -FEE REQUIRED LFITZGERALD
Note: water metere pit and sewer clean out were unable to be inspected due to being covered over by sod
BLD - BUILDING FINAL 08/02/2019 CANCELLED BY APPLICANT WEB
FINAL SURVEY (OFFICE USE ONLY) 06/12/2019 APPROVED KHOWELL
ROW FIELD SURVEY /GRADING CERTIFICATION 06/12/2019 APPROVED KHOWELL
TUB SET 05/22/2019 APPROVED JGIBSON
ROW- PRE-APRON (PRE-POUR) 05/02/2019 APPROVED KHOWELL
Note: THIS IS A REINSPECTION
ROW- PAVER RESTRAINTS 04/26/2019 APPROVED KHOWELL
ROW- PRE-APRON (PRE-POUR) 04/26/2019 PARTIALLY APPROVED KHOWELL
Note: SIDEWALK AND APRON POUR PAVER DRIVEWAY
ELECTRIC - EARLY POWER 04/15/2019 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED POWER 3:50
GRAVITY SEWER TEST 02/28/2019 APPROVED JGIBSON
U - SEWER TIE IN 02/28/2019 APPROVED - AS NOTED JGIBSON
Note: PLUMBER SENT VIDEO OF U-TIE IN
LATH/BRICK/ WATER BARRIER 02/26/2019 APPROVED MWILLIAMS
INSULATION 02/19/2019 APPROVED MWILLIAMS
INSULATION 02/15/2019 Disapproved -FEE REQUIRED DROCKWELL
Note: Fireblock chase left after entry see coke can look up
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/13/2019 APPROVED MWILLIAMS
ALL ROUGH 02/13/2019 APPROVED MWILLIAMS
ALL ROUGH 02/08/2019 Disapproved -FEE REQUIRED WMILLER
Note: 1. NEED TO CALL IN TUB SET PRIOR TO CLOSING SUPPORT 2. SUPPORT STRAPPING FBC R E 3605.7 AND NEC.334 NEEDS TO BE STRAPPED PER NEC 334 (WITHIN 12 INCHES AND AT 30 INCH ENTERVALS ) (CHECK SER IN ATTIC SPACE AND WIRING AT PANEL) 3. NAIL PLATES FOR ELECTRIC, PLUMBING AND MECHANICAL (HIGHLIGHTED ON PLANS) (AND AT ALL LOW VOLTAGE) CAN NOT CALL IN THIS INSPECTION UNTIL PASSING ROOF SHEATHING BRACES TIES DOWN CELL (SEE NOTES FROM INSPECTOR MW PRIOR) (ALSO GROUT CELL SOLID AT GARAGE WINDOW LENTIL)
ELECTRIC-TUG 02/08/2019 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED POWER 2:30
ALL ROUGH 02/05/2019 Disapproved -FEE REQUIRED WMILLER
Note: 1. SUPPORT STRAPPING FBC R E 3605.7 AND NEC.334 NEEDS TO BE STRAPPED PER NEC 334 (WITHIN 12 INCHES AND AT 30 INCH ENTERVALS ) (CHECK SER IN ATTIC SPACE AND WIRING AT PANEL) 2. WIRES OUT OF WALL AT AHU AND WATER HEATER 3. NEED TO CALL IN TUB SET PRIOR TO CLOSING SUPPORT 4. NAIL PLATES FOR ELECTRIC, PLUMBING AND MECHANICAL (HIGHLIGHTED ON PLANS) (AND AT ALL LOW VOLTAGE) 5. FIRE BLOCKING (HIGHLIGHTED ON PLANS)
ELECTRIC-TUG 01/28/2019 Disapproved -FEE REQUIRED RMARTIN
Note: SER CABLE ABOVE METER IS EXPOSED, CONDUCTOR FOR GFCI AT TUG NOT SAFED OFF, NEEDS TO BE LANDED ON BREAKER
ROOF VALLEY & METAL 01/09/2019 APPROVED MWILLIAMS
ELECTRIC-TUG 01/04/2019 CANCELLED BY APPLICANT WEB
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/02/2019 PARTIALLY APPROVED MWILLIAMS
Note: Must submit revision for front entry plans call for 6x6 posts and simpson connections homes being built with CMU colums. Must leave sheathing off of entry arch for inspections. Must submit revisions to get approval in full
ROOF SHEATHING 12/13/2018 APPROVED MWILLIAMS
TIE BEAM / LINTEL 11/28/2018 APPROVED WMILLER
Note: approved
TIE BEAM / LINTEL 11/27/2018 Disapproved -FEE REQUIRED WMILLER
Note: 1. PROTECTION FOR REINFORCEMENT (6TH EDITION) R606.3.4 REINFORCING BARS USED IN MASONRY WALLS SHALL HAVE NOT LESS THAN 2 inches FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER 2. MISSING VIRTICLE REINFORCEMENT (MARKED ON FLOOR PLAN)
MONOLITHIC SLAB 11/13/2018 APPROVED DROCKWELL
MONOLITHIC SLAB 11/09/2018 Disapproved -FEE REQUIRED WMILLER
Note: 1. CLEARANCE ON REBAR FROM EARTH 3” FBC R404.1.2.3.7.4 2. SOIL IN WAY OF MONO POUR AT PERIMETER
PLUMBING 1ST ROUGH UNDERGROUND 11/05/2018 APPROVED JGIBSON
FOUND SURVEY APPROVED (OFFICE) 09/28/2018 APPROVED DREWIS
FOOTER 09/06/2018 APPROVED CMINI
FOOTER 09/05/2018 Disapproved -FEE REQUIRED CMINI
Note: need to remove all vegetation and organic material from footers, removal of tree root. FBC 408.5. CLEARANCE ON REBAR FROM EARTH 3 1D FBC 403
FOOTER 09/04/2018 CANCELLED BY APPLICANT CMINI

Review History

Department Status Date In Date Out
BLD COMPLETE 01/08/2019 01/11/2019
Note: Released By: JHINDMAN
SW1 COMPLETE 09/26/2018 09/28/2018
Note: Released By: DREWIS Foundation survey
ELEC COMPLETE 07/20/2018 07/26/2018
Note: Released By: DREWIS
ZON COMPLETE 07/13/2018 07/13/2018
Note: Released By: AMOBLEY
URB COMPLETE 07/13/2018 07/20/2018
Note: Released By: JBEAUDET
MECH COMPLETE 07/13/2018 07/19/2018
Note: Released By: FREODICA
SW1 COMPLETE 07/13/2018 07/17/2018
Note: Released By: DREWIS
ELEC HOLD 07/13/2018 07/17/2018
Note: Held By: DREWIS Provide load calculations. Daniel Rewis 986-4736
URB HOLD 06/29/2018 07/02/2018
Note: Held By: JBEAUDET Need to install 2 street trees 1-2" caliper Live Oak right front and 1 2" caliper Drake Elm left front both 30 gallon min. container size, Installed a minimum 5ft and a maximum of 12ft. 6in.from sidewalks , curbing, driveways and utilities. with a maximum of 50ft on center. This is per the approved street tree plan for Hidden Lakes Pud. Phase 2 Water Oaks.
BLD COMPLETE 06/28/2018 07/05/2018
Note: Released By: JHINDMAN
ELEC HOLD 06/28/2018 07/03/2018
Note: Held By: DREWIS Provide load calculations. Additional GFCI needed in the laundry area, NEC 2014 210.52F. Daniel Rewis 986-4736
ENGIN1 COMPLETE 06/28/2018 07/02/2018
Note: Released By: TBAKER
MECH HOLD 06/28/2018 07/03/2018
Note: Held By: FREODICA Held By: FREODICA 1. Provide referenced design location either Daytona Beach or St. Agustine per FBCEC 6th ed. R301.1 2. The capacity of selected hvac units shall not be more than 1.15 times greater than the total calculated cooling loads per FBCEC 6th ed. R403.7.1.1. F.Reodica -386-986-4734.
PLUM COMPLETE 06/28/2018 07/03/2018
Note: Released By: FREODICA
SW1 HOLD 06/28/2018 07/03/2018
Note: Held By: DREWIS Provide additional measurements for existing elevations on left side adjacent lot 14. Proposed elevations on the right side of 20.7' allow flow from the adjacent lot 16. Daniel Rewis 986-4736
UD1 COMPLETE 06/28/2018 07/03/2018
Note: Released By: MBACON This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
ZON HOLD 06/28/2018 06/29/2018
Note: Held By: AMOBLEY Flood maps were updated 6/6/18. Surveys must have the new information

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 08/08/2019
REINSPECTION FEE ¤40.00 08/08/2019
REINSPECTION FEE ¤40.00 08/08/2019
REINSPECTION FEE ¤40.00 02/07/2019
REINSPECTION FEE ¤40.00 02/07/2019
REINSPECTION FEE ¤40.00 02/07/2019
REINSPECTION FEE ¤40.00 02/07/2019
REVISION ¤40.00 02/07/2019
REINSPECTION FEE ¤40.00 09/12/2018
SITE PLAN 20 ¤20.00 08/01/2018
SURCHARGE FS 533.721 ¤16.35 08/01/2018
SURCHARGE - FS 468.631 ¤24.53 08/01/2018
STORM WATER PERMIT FEES ¤80.00 08/01/2018
3% TRANS IMPACT FEE CREDIT (¤89.43) 08/01/2018
NEW RESIDENTIAL INSPECTIONS ¤674.00 08/01/2018
ADMIN FEE ¤20.00 08/01/2018
ELECTRIC FEE ¤262.20 08/01/2018
3% FIRE IMPACT FEE CREDIT (¤6.56) 08/01/2018
IMPACT FEE FIRE ¤218.79 08/01/2018
IMPACT FEE PARKS ¤849.24 08/01/2018
IMPACT FEE SCHOOL ¤3,600.00 08/01/2018
IMPACT FEE TRANSPORTATION ¤2,981.00 08/01/2018
MECHANICAL FEE ¤262.20 08/01/2018
3% PARKS IMPACT FEE CREDIT (¤25.48) 08/01/2018
PLAN CHECK FEE ¤134.80 08/01/2018
PLUMBING FEE ¤262.20 08/01/2018
Fees Total Due: ¤0.00 Total Paid: ¤9,643.84