I want to search for...
Permit #2018061245
Permit Details
Status: COED
| Parcel Id: 33-11-31-3061-00010-0150 |
| CONDITIONED SPACE: 2632 sqft |
| GARAGE: 705 sqft |
| OPENED PORCH (WITH ROOF) : 331 sqft |
| OPENED PORCH (WITH ROOF) : 72 sqft |
| Total Square Footage: 3740 sqft |
| Block: 00010 |
| Subdivision: 2108 - HIDDEN LAKES PHASE II - TOSCANA |
| Job Phone: 863-420-2100 |
| Location Address: 29 NEW LEATHERWOOD DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 08/01/2018 |
| NOC: RECORDED |
| Applicant name: YUVAL BOTANSKY |
| Owner: APPLIED BUILDING DEVELOPMENT OF ORLANDO - PC INC |
|
Address 131 CHADWICK DRIVE DAVENPORT, FL 33837 |
| Lot: 0150 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
APPLIED BUILDING DEVELOPMENT COMPANY - OAKHILLS IN
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
131 CHADWICK DRIVE DAVENPORT, FL 33837 |
CRC1330762 (Exp: 08/31/2026) | 863-420-2100 | 386-517-6865 |
Sub Contractors
YUVAL BOTANSKY
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
131 CHADWICK DRIVE DAVENPORT, FL 33837 |
CRC1330762 (Exp: 08/31/2026) | 863-420-2100 | 386-517-6865 |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| CANCEL |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2022) | 877-906-1113 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
TERRY HILE BURD
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO Box 180308 CASSELBERRY, FL 32707 |
CAC1814423 (Exp: 08/31/2024) | (407) 831-3600 | (407)831-2893 |
SANTOS L HERNANDEZ
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
946 SHADDICK DRIVE ORANGE CITY, FL 32763 |
CCC1328011 (Exp: 08/31/2026) | 386-218-4942 | 386-218-4937 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 08/13/2019 | FINAL APPROVED | LFITZGERALD |
| Note: THIS IS A REINSPECTION-wo in to utility to raise the water meter pit and reclaim | |||
| BLD - BUILDING FINAL | 08/12/2019 | APPROVED | MWILLIAMS |
| U-CROSS CONNECTION | 08/08/2019 | CANCELLED BY INSPECTOR | LFITZGERALD |
| Note: water meter pit could not be located due to being covered over by sod | |||
| ROW - FINAL APRON (AFTER POUR) | 08/08/2019 | APPROVED | KHOWELL |
| ROW - STORMWATER FINAL | 08/08/2019 | FINAL APPROVED | KHOWELL |
| U -UTILITY RESIDENTIAL FINAL | 08/08/2019 | Disapproved -FEE REQUIRED | LFITZGERALD |
| Note: water metere pit and sewer clean out were unable to be inspected due to being covered over by sod | |||
| BLD - BUILDING FINAL | 08/02/2019 | CANCELLED BY APPLICANT | WEB |
| FINAL SURVEY (OFFICE USE ONLY) | 06/12/2019 | APPROVED | KHOWELL |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/12/2019 | APPROVED | KHOWELL |
| TUB SET | 05/22/2019 | APPROVED | JGIBSON |
| ROW- PRE-APRON (PRE-POUR) | 05/02/2019 | APPROVED | KHOWELL |
| Note: THIS IS A REINSPECTION | |||
| ROW- PAVER RESTRAINTS | 04/26/2019 | APPROVED | KHOWELL |
| ROW- PRE-APRON (PRE-POUR) | 04/26/2019 | PARTIALLY APPROVED | KHOWELL |
| Note: SIDEWALK AND APRON POUR PAVER DRIVEWAY | |||
| ELECTRIC - EARLY POWER | 04/15/2019 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO DELL FPL RELEASED POWER 3:50 | |||
| GRAVITY SEWER TEST | 02/28/2019 | APPROVED | JGIBSON |
| U - SEWER TIE IN | 02/28/2019 | APPROVED - AS NOTED | JGIBSON |
| Note: PLUMBER SENT VIDEO OF U-TIE IN | |||
| LATH/BRICK/ WATER BARRIER | 02/26/2019 | APPROVED | MWILLIAMS |
| INSULATION | 02/19/2019 | APPROVED | MWILLIAMS |
| INSULATION | 02/15/2019 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Fireblock chase left after entry see coke can look up | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/13/2019 | APPROVED | MWILLIAMS |
| ALL ROUGH | 02/13/2019 | APPROVED | MWILLIAMS |
| ALL ROUGH | 02/08/2019 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 1. NEED TO CALL IN TUB SET PRIOR TO CLOSING SUPPORT 2. SUPPORT STRAPPING FBC R E 3605.7 AND NEC.334 NEEDS TO BE STRAPPED PER NEC 334 (WITHIN 12 INCHES AND AT 30 INCH ENTERVALS ) (CHECK SER IN ATTIC SPACE AND WIRING AT PANEL) 3. NAIL PLATES FOR ELECTRIC, PLUMBING AND MECHANICAL (HIGHLIGHTED ON PLANS) (AND AT ALL LOW VOLTAGE) CAN NOT CALL IN THIS INSPECTION UNTIL PASSING ROOF SHEATHING BRACES TIES DOWN CELL (SEE NOTES FROM INSPECTOR MW PRIOR) (ALSO GROUT CELL SOLID AT GARAGE WINDOW LENTIL) | |||
| ELECTRIC-TUG | 02/08/2019 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO DELL FPL RELEASED POWER 2:30 | |||
| ALL ROUGH | 02/05/2019 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 1. SUPPORT STRAPPING FBC R E 3605.7 AND NEC.334 NEEDS TO BE STRAPPED PER NEC 334 (WITHIN 12 INCHES AND AT 30 INCH ENTERVALS ) (CHECK SER IN ATTIC SPACE AND WIRING AT PANEL) 2. WIRES OUT OF WALL AT AHU AND WATER HEATER 3. NEED TO CALL IN TUB SET PRIOR TO CLOSING SUPPORT 4. NAIL PLATES FOR ELECTRIC, PLUMBING AND MECHANICAL (HIGHLIGHTED ON PLANS) (AND AT ALL LOW VOLTAGE) 5. FIRE BLOCKING (HIGHLIGHTED ON PLANS) | |||
| ELECTRIC-TUG | 01/28/2019 | Disapproved -FEE REQUIRED | RMARTIN |
| Note: SER CABLE ABOVE METER IS EXPOSED, CONDUCTOR FOR GFCI AT TUG NOT SAFED OFF, NEEDS TO BE LANDED ON BREAKER | |||
| ROOF VALLEY & METAL | 01/09/2019 | APPROVED | MWILLIAMS |
| ELECTRIC-TUG | 01/04/2019 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/02/2019 | PARTIALLY APPROVED | MWILLIAMS |
| Note: Must submit revision for front entry plans call for 6x6 posts and simpson connections homes being built with CMU colums. Must leave sheathing off of entry arch for inspections. Must submit revisions to get approval in full | |||
| ROOF SHEATHING | 12/13/2018 | APPROVED | MWILLIAMS |
| TIE BEAM / LINTEL | 11/28/2018 | APPROVED | WMILLER |
| Note: approved | |||
| TIE BEAM / LINTEL | 11/27/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 1. PROTECTION FOR REINFORCEMENT (6TH EDITION) R606.3.4 REINFORCING BARS USED IN MASONRY WALLS SHALL HAVE NOT LESS THAN 2 inches FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER 2. MISSING VIRTICLE REINFORCEMENT (MARKED ON FLOOR PLAN) | |||
| MONOLITHIC SLAB | 11/13/2018 | APPROVED | DROCKWELL |
| MONOLITHIC SLAB | 11/09/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 1. CLEARANCE ON REBAR FROM EARTH 3” FBC R404.1.2.3.7.4 2. SOIL IN WAY OF MONO POUR AT PERIMETER | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 11/05/2018 | APPROVED | JGIBSON |
| FOUND SURVEY APPROVED (OFFICE) | 09/28/2018 | APPROVED | DREWIS |
| FOOTER | 09/06/2018 | APPROVED | CMINI |
| FOOTER | 09/05/2018 | Disapproved -FEE REQUIRED | CMINI |
| Note: need to remove all vegetation and organic material from footers, removal of tree root. FBC 408.5. CLEARANCE ON REBAR FROM EARTH 3 1D FBC 403 | |||
| FOOTER | 09/04/2018 | CANCELLED BY APPLICANT | CMINI |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/08/2019 | 01/11/2019 |
| Note: Released By: JHINDMAN | |||
| SW1 | COMPLETE | 09/26/2018 | 09/28/2018 |
| Note: Released By: DREWIS Foundation survey | |||
| ELEC | COMPLETE | 07/20/2018 | 07/26/2018 |
| Note: Released By: DREWIS | |||
| ZON | COMPLETE | 07/13/2018 | 07/13/2018 |
| Note: Released By: AMOBLEY | |||
| URB | COMPLETE | 07/13/2018 | 07/20/2018 |
| Note: Released By: JBEAUDET | |||
| MECH | COMPLETE | 07/13/2018 | 07/19/2018 |
| Note: Released By: FREODICA | |||
| SW1 | COMPLETE | 07/13/2018 | 07/17/2018 |
| Note: Released By: DREWIS | |||
| ELEC | HOLD | 07/13/2018 | 07/17/2018 |
| Note: Held By: DREWIS Provide load calculations. Daniel Rewis 986-4736 | |||
| URB | HOLD | 06/29/2018 | 07/02/2018 |
| Note: Held By: JBEAUDET Need to install 2 street trees 1-2" caliper Live Oak right front and 1 2" caliper Drake Elm left front both 30 gallon min. container size, Installed a minimum 5ft and a maximum of 12ft. 6in.from sidewalks , curbing, driveways and utilities. with a maximum of 50ft on center. This is per the approved street tree plan for Hidden Lakes Pud. Phase 2 Water Oaks. | |||
| BLD | COMPLETE | 06/28/2018 | 07/05/2018 |
| Note: Released By: JHINDMAN | |||
| ELEC | HOLD | 06/28/2018 | 07/03/2018 |
| Note: Held By: DREWIS Provide load calculations. Additional GFCI needed in the laundry area, NEC 2014 210.52F. Daniel Rewis 986-4736 | |||
| ENGIN1 | COMPLETE | 06/28/2018 | 07/02/2018 |
| Note: Released By: TBAKER | |||
| MECH | HOLD | 06/28/2018 | 07/03/2018 |
| Note: Held By: FREODICA Held By: FREODICA 1. Provide referenced design location either Daytona Beach or St. Agustine per FBCEC 6th ed. R301.1 2. The capacity of selected hvac units shall not be more than 1.15 times greater than the total calculated cooling loads per FBCEC 6th ed. R403.7.1.1. F.Reodica -386-986-4734. | |||
| PLUM | COMPLETE | 06/28/2018 | 07/03/2018 |
| Note: Released By: FREODICA | |||
| SW1 | HOLD | 06/28/2018 | 07/03/2018 |
| Note: Held By: DREWIS Provide additional measurements for existing elevations on left side adjacent lot 14. Proposed elevations on the right side of 20.7' allow flow from the adjacent lot 16. Daniel Rewis 986-4736 | |||
| UD1 | COMPLETE | 06/28/2018 | 07/03/2018 |
| Note: Released By: MBACON This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. | |||
| ZON | HOLD | 06/28/2018 | 06/29/2018 |
| Note: Held By: AMOBLEY Flood maps were updated 6/6/18. Surveys must have the new information |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 08/08/2019 |
| REINSPECTION FEE | ¤40.00 | 08/08/2019 |
| REINSPECTION FEE | ¤40.00 | 08/08/2019 |
| REINSPECTION FEE | ¤40.00 | 02/07/2019 |
| REINSPECTION FEE | ¤40.00 | 02/07/2019 |
| REINSPECTION FEE | ¤40.00 | 02/07/2019 |
| REINSPECTION FEE | ¤40.00 | 02/07/2019 |
| REVISION | ¤40.00 | 02/07/2019 |
| REINSPECTION FEE | ¤40.00 | 09/12/2018 |
| SITE PLAN 20 | ¤20.00 | 08/01/2018 |
| SURCHARGE FS 533.721 | ¤16.35 | 08/01/2018 |
| SURCHARGE - FS 468.631 | ¤24.53 | 08/01/2018 |
| STORM WATER PERMIT FEES | ¤80.00 | 08/01/2018 |
| 3% TRANS IMPACT FEE CREDIT | (¤89.43) | 08/01/2018 |
| NEW RESIDENTIAL INSPECTIONS | ¤674.00 | 08/01/2018 |
| ADMIN FEE | ¤20.00 | 08/01/2018 |
| ELECTRIC FEE | ¤262.20 | 08/01/2018 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.56) | 08/01/2018 |
| IMPACT FEE FIRE | ¤218.79 | 08/01/2018 |
| IMPACT FEE PARKS | ¤849.24 | 08/01/2018 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 08/01/2018 |
| IMPACT FEE TRANSPORTATION | ¤2,981.00 | 08/01/2018 |
| MECHANICAL FEE | ¤262.20 | 08/01/2018 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 08/01/2018 |
| PLAN CHECK FEE | ¤134.80 | 08/01/2018 |
| PLUMBING FEE | ¤262.20 | 08/01/2018 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,643.84 |