I want to search for...

Permit #2018071182

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7003-00200-0020
CONDITIONED SPACE: 462 sqft
Total Square Footage: 462 sqft
Block: 00200
Subdivision: 2190 - SECTION 3-COUNTRY CLUB COVE
Job Phone: (386)445-9424
Location Address: 4 CAMEO CT
Type: BA - BUILDING ADDITION
Issue Date: 09/21/2018
NOC: RECORDED
Applicant name: JOSE LOPEZ
Owner: GOEBEL JOHN TRUSTEE & JOANN MOORE SILVA TRUSTEE JT

Address

4 CAMEO COURT

PALM COAST, FL 32137

Lot: 0020
Job Description: NEW AC ADDITION TO REAR OF THE HOUSE
Type: CN

Contractor

JOSE LOPEZ CONSTRUCTION, INC.
Status Location Address State License Number Phone
ACTIVE

14 UTILITY DRIVE #12

BUNNELL, FL 32110

CRC1327719 (Exp: 08/31/2026) (386)445-9424

Sub Contractors

ROBERT CARLTON LITTLE
Status Location Address State License Number Phone
ACTIVE

3050 EAST MOODY BLVD

BUNNELL, FL 32110

EC13003740 (Exp: 08/31/2026) 386-931-1708
THOMAS ALAN MOSE
Status Location Address State License Number Phone Fax
INACTIVE

PO BOX 1894

HOLLY HILL, FL 32117

CAC048082 (Exp: 08/31/2026) 386-255-4545 (386)252-4979

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 01/16/2019 FINAL APPROVED WMILLER
Note: FINAL APPROVED
FINAL SURVEY (OFFICE USE ONLY) 01/15/2019 APPROVED JHINDMAN
U -UTILITY RESIDENTIAL FINAL 01/14/2019 FINAL APPROVED JNICHOLS
INSULATION 01/11/2019 APPROVED WMILLER
Note: THIS IS A REINSPECTION APPROVED
LATH/BRICK/ WATER BARRIER 11/15/2018 APPROVED WMILLER
Note: APPROVED
INSULATION 11/05/2018 Disapproved -FEE REQUIRED WMILLER
Note: 1. FIREBLOCKING R302.11 (4) PIPES, DUCTS, CABLES, AND WIRES AT CEILING AND FLOOR LEVEL (WITH APPROVED MATERIAL) (MUST USE FIRE RATED FOAM) 2. ENERGY CALCS CALL FOR R-38.... (R-30 IS INSTALLED)
WALL SHEATHING 11/02/2018 APPROVED WMILLER
Note: APPROVED
INSULATION 11/02/2018 CANCELLED BY APPLICANT JHINDMAN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/01/2018 APPROVED WMILLER
Note: APPROVED
ALL ROUGH 11/01/2018 APPROVED WMILLER
Note: APPROVED
FOUND SURVEY APPROVED (OFFICE) 10/31/2018 APPROVED DREWIS
MONOLITHIC SLAB 10/03/2018 APPROVED WMILLER
Note: APPROVED

Review History

Department Status Date In Date Out
SW1 COMPLETE 01/10/2019 01/15/2019
Note: Released By: JHINDMAN final
MECH COMPLETE 11/14/2018 11/21/2018
Note: Released By: RLEE
SW1 COMPLETE 10/29/2018 10/31/2018
Note: Released By: DREWIS foundation
BLD COMPLETE 10/03/2018 10/08/2018
Note: Released By: JHINDMAN
ELEC COMPLETE 09/20/2018 09/21/2018
Note: Released By: DREWIS
ELEC HOLD 08/31/2018 09/07/2018
Note: Held By: JHINDMAN 1. Provide electrical receptacle spacing for the walls per 6th ed. FBC R E3902.1. J. hindman 986-3784.
BLD COMPLETE 08/31/2018 09/07/2018
Note: Released By: JHINDMAN
MECH COMPLETE 08/31/2018 09/07/2018
Note: Released By: JHINDMAN
ELEC HOLD 08/01/2018 08/01/2018
Note: Held By: DREWIS Please categorize the sunroom type this enclosure is to be in order for a proper electrical review to be performed, FBC 6ht ed. 301.2.1.1.1 Daniel Rewis 986-4736
MECH HOLD 08/01/2018 08/06/2018
Note: Held By: FREODICA 1. Provide complete information on Installed Values Column of FormR402-2017 Table R402A and Table 402B per FBC 6th ed. 107.1. 2. Provide the manufacturer and model number of indoor/outdoor of selected mini-split hvac units including sensible and total capacites per FBCEC 6th ed. R403.7/R502. F.Reodica -386-986-4734.
BLD HOLD 07/31/2018 08/01/2018
Note: Held By: JHINDMAN 1. Identify the elevation of the new walls above grade. Identify the elevation of the slab above the pool deck. Wood framed stucco walls must be a minimum of 4 inches above grade for the weep screed. per 6th ed. FBC R703.7..2.1. J. Hindman 986-3784.
SW1 COMPLETE 07/31/2018 08/01/2018
Note: Released By: DREWIS
ZON COMPLETE 07/31/2018 07/31/2018
Note: Released By: AMOBLEY

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REVISION ¤40.00 01/10/2019
REINSPECTION FEE ¤40.00 01/10/2019
REMODEL/ADDITION/ACCES INSPECT ¤40.00 09/21/2018
SITE PLAN 20 ¤20.00 09/21/2018
SURCHARGE FS 533.721 ¤3.01 09/21/2018
SURCHARGE - FS 468.631 ¤4.52 09/21/2018
STORM WATER PERMIT FEES ¤80.00 09/21/2018
ADMIN FEE ¤20.00 09/21/2018
ELECTRIC FEE ¤90.60 09/21/2018
MECHANICAL FEE ¤90.60 09/21/2018
PLAN CHECK FEE ¤40.00 09/21/2018
Fees Total Due: ¤0.00 Total Paid: ¤468.73