Permit #2018080531
Permit Details
Status: COED
| Parcel Id: 33-11-31-3061-00020-0040 |
| CONDITIONED SPACE: 2614 sqft |
| GARAGE: 556 sqft |
| OPENED PORCH (WITH ROOF) : 153 sqft |
| OPENED PORCH (WITH ROOF) : 71 sqft |
| Total Square Footage: 3394 sqft |
| Block: 00020 |
| Subdivision: 2108 - HIDDEN LAKES PHASE II - TOSCANA |
| Job Phone: 863-420-2100 |
| Location Address: 16 NEW WATER OAK DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/12/2018 |
| NOC: RECORDED |
| Applicant name: YUVAL BOTANSKY |
| Owner: APPLIED BUILDING DEVELOPMENT OF ORLANDO - PC INC |
|
Address 131 CHADWICK DRIVE DAVENPORT, FL 33837 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤235,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
APPLIED BUILDING DEVELOPMENT COMPANY - OAKHILLS IN
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
131 CHADWICK DRIVE DAVENPORT, FL 33837 |
CRC1330762 (Exp: 08/31/2026) | 863-420-2100 | 386-517-6865 |
Sub Contractors
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| CANCEL |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2022) | 877-906-1113 |
TERRY HILE BURD
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO Box 180308 CASSELBERRY, FL 32707 |
CAC1814423 (Exp: 08/31/2024) | (407) 831-3600 | (407)831-2893 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
SANTOS L HERNANDEZ
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
946 SHADDICK DRIVE ORANGE CITY, FL 32763 |
CCC1328011 (Exp: 08/31/2026) | 386-218-4942 | 386-218-4937 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 07/01/2019 | APPROVED | MWILLIAMS |
| U-CROSS CONNECTION | 07/01/2019 | APPROVED | MBACON |
| ROW - FINAL APRON (AFTER POUR) | 07/01/2019 | APPROVED | KHOWELL |
| ROW - STORMWATER FINAL | 07/01/2019 | FINAL APPROVED | KHOWELL |
| U -UTILITY RESIDENTIAL FINAL | 07/01/2019 | FINAL APPROVED | MBACON |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/28/2019 | APPROVED | KHOWELL |
| FINAL SURVEY (OFFICE USE ONLY) | 06/28/2019 | APPROVED | KHOWELL |
| Note: THIS IS A REINSPECTION | |||
| FINAL SURVEY (OFFICE USE ONLY) | 06/27/2019 | Disapproved - NO FEE | KHOWELL |
| Note: SEE NOTES ON SURVEY MARK UP | |||
| ROW- PRE-APRON (PRE-POUR) | 06/19/2019 | APPROVED - AS NOTED | RGROSS |
| Note: THIS IS A REINSPECTION. BASE NEEDS GOOD COMPACTION BEFORE PAVERS ARE PLACED. | |||
| ELECTRIC - EARLY POWER | 06/14/2019 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO SUSAN FPL RELEASED POWER 3:15 | |||
| ROW- PRE-APRON (PRE-POUR) | 06/13/2019 | Disapproved -FEE REQUIRED | KHOWELL |
| Note: COULD NOT FIND SITE PLAN, IT NEEDS TO BE PINNED IN DOC BOX. REMOVE WASP NEST FROM DOC BOX | |||
| ROW- PRE-APRON (PRE-POUR) | 06/13/2019 | PARTIALLY APPROVED | KHOWELL |
| Note: THIS IS A REINSPECTION SIDEWALK AND APRON POUR PAVER UPPER | |||
| ROW- PAVER RESTRAINTS | 06/13/2019 | Disapproved - NO FEE | KHOWELL |
| Note: WASHED IN AND DO NOT LOOK DEEP ENOUGH | |||
| ROW- PAVER RESTRAINTS | 06/13/2019 | APPROVED | KHOWELL |
| Note: THIS IS A REINSPECTION | |||
| U - SEWER TIE IN | 06/06/2019 | APPROVED | JGIBSON |
| GRAVITY SEWER TEST | 06/06/2019 | APPROVED | JGIBSON |
| ELECTRIC - EARLY POWER | 05/13/2019 | Disapproved -FEE REQUIRED | RMARTIN |
| Note: WALL OVEN,MICRO,COOK TOP NOT SAFED OFF NEEDS TO BE CAPPED OFF AND IN A BOX WITH PLATE | |||
| LATH/BRICK/ WATER BARRIER | 04/15/2019 | APPROVED | DROCKWELL |
| INSULATION | 03/20/2019 | APPROVED | MWILLIAMS |
| ALL ROUGH | 03/08/2019 | APPROVED | MWILLIAMS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/06/2019 | APPROVED | MWILLIAMS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/05/2019 | CANCELLED BY APPLICANT | WMILLER |
| Note: cancelled per Josh | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/01/2019 | Disapproved -FEE REQUIRED | MWILLIAMS |
| Note: As previously noted front entry posts are covered and can not be seen with an extension ladder, Remove sheathing or provide an extension ladder tied offf to reach inspection port holes. THIS IS AN ONGOING ISSUE AND IT NEEDS TO BE CORRECTED> MUST LEAVE SHEATHING OFF AT TIE DOWN AREAS FOR INSPETION DO NOT COVER CRITICAL POINTS OF CONNECTION PRIOR TO INSPECTION> | |||
| ALL ROUGH | 02/27/2019 | Disapproved - NO FEE | MWILLIAMS |
| Note: framing still in progress not ready for inspection sheathing braces and ties should be completed prior to this inspection. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/27/2019 | Disapproved -FEE REQUIRED | MWILLIAMS |
| Note: framing beyond point of inspection front entry posts are covered up cant see tie downs this inspection should be called in prior to all rough | |||
| ROOF VALLEY & METAL | 02/27/2019 | APPROVED | MWILLIAMS |
| ELECTRIC-TUG | 02/21/2019 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO DELL FPL RELEASED POWER 3:30 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/12/2019 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 1. X-BRACES CANNOT EXCEED 20' FROM HIP GIRDER TO CENTER OF X-BRACING PER DETAIL (TB05), 2. MISSING DTT2Z HIGHLIGHTED ON PLANS | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/12/2019 | Disapproved - NO FEE | WMILLER |
| Note: THIS IS A REINSPECTION WRONG INFO RESULTED PRIOR TO THIS RESULT DUE TO SYSTEM GLITCH FEE WILL NOT BE ADDED TO THE INSPECTION AS FEE WAS ALREADY CHARGED WHEN SYTEM RESULTED INCORRECTLY (FEE WAS CHARGED ON PRIOR INSPECTION) 1. CONTINUOUS LOAD PATH… R301,2.1 OVERFRAMING NOT TIED TO STRUCTURAL MEMBERS BENEATH 2. STRAPS MISSING FASTENERS HIGHLIGHTED ON PLANS | |||
| ROOF SHEATHING | 01/22/2019 | APPROVED | MWILLIAMS |
| TIE BEAM / LINTEL | 01/03/2019 | APPROVED | MWILLIAMS |
| TIE BEAM / LINTEL | 12/28/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 1. CLEARANCE FROM MASONRY (6TH EDITION) R606.3.4 MINIMUM WALL REINFORCING STEEL COVERAGE NOT MET (.75 INCH) (CHECK ALL) 2. MISSING STEEL IN TOP LENTEL (CHECK ALL) | |||
| MONOLITHIC SLAB | 12/13/2018 | APPROVED | MWILLIAMS |
| MONOLITHIC SLAB | 12/11/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: STILL WORKING ON REPAIRS, NOT READY, (MAKE SURE REVISION FOR REPAIRS IS ON SITE FOR INSPECTION), REBAR MUST BE INSIDE CELLS AS MARKED ON PLANS AND PER CODE STEMWALL CONSTRUCTION DOES NOT COMPLY WITH ENGINERING,CODE,CONSTRUCTION DOCUMENTS,ACI 318 VERTICLE REINFORCEMENT DOES NOT COMPLY WITH PLANS OR BUILDING CODE FOR HOOKS, EMBEDMENT, AND ANCHORAGE ALL CUT OFF REBAR TO COMPLY WITH FBC FOR MINIMUM CLEARANCE NEED TO USE PROPER BLOCKS AS INDICATED IN PLANS | |||
| MONOLITHIC SLAB | 11/27/2018 | Disapproved - NO FEE | WMILLER |
| Note: FOUNDATION STEMWALLS MUST BE GROUTED SOLID AND FREE OF DEBRIS AND DIRT. REBAR MUST BE INSIDE CELLS AS MARKED ON PLANS AND PER CODE STEMWALL CONSTRUCTION DOES NOT COMPLY WITH ENGINERING,CODE,CONSTRUCTION DOCUMENTS,ACI 318 VERTICLE REINFORCEMENT DOES NOT COMPLY WITH PLANS OR BUILDING CODE FOR HOOKS, EMBEDMENT, AND ANCHORAGE ALL CUT OFF REBAR TO COMPLY WITH FBC FOR MINIMUM CLEARANCE NEED TO USE PROPER BLOCKS AS INDICATED IN PLANS | |||
| MONOLITHIC SLAB | 11/26/2018 | CANCELLED BY APPLICANT | WMILLER |
| Note: cancelled per Josh | |||
| MONOLITHIC SLAB | 11/20/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: FOUNDATION STEMWALLS MUST BE GROUTED SOLID AND FREE OF DEBRIS AND DIRT. REBAR MUST BE INSIDE CELLS AS MARKED ON PLANS AND PER CODE STEMWALL CONSTRUCTION DOES NOT COMPLY WITH ENGINERING,CODE,CONSTRUCTION DOCUMENTS,ACI 318 | |||
| FOUND SURVEY APPROVED (OFFICE) | 11/20/2018 | APPROVED | DREWIS |
| PLUMBING 1ST ROUGH UNDERGROUND | 11/16/2018 | APPROVED | JGIBSON |
| FOOTER | 10/31/2018 | APPROVED | DROCKWELL |
| FOOTER | 10/29/2018 | CANCELLED BY APPLICANT | WMILLER |
| Note: cancell per Josh | |||
| FOOTER | 10/25/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 12 inch MINIMUM DEPTH , UNDISTURBED GROUND SURFACE… R403.1.3.4 and in accordance with R401.2, and R403.1 ALL FOOTINGS SHALL BE PLACED AT LEAST 12 in. BELOW THE UNDISTURBED GROUND SURFACE (NEED ADDITIONAL COMPACTION REPORT FOR AREAS OUTSIDE OF FOOTINGS AFTER ADDING REQUIRED MINIMUM DEPTH) (CHECK ALL) |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/25/2019 | 01/31/2019 |
| Note: Released By: JHINDMAN | |||
| BLD | COMPLETE | 11/30/2018 | 12/07/2018 |
| Note: Released By: JHINDMAN | |||
| SW1 | COMPLETE | 11/19/2018 | 11/20/2018 |
| Note: Released By: DREWIS FOUND S | |||
| MECH | HOLD | 08/30/2018 | 08/30/2018 |
| Note: Held By: JHINDMAN just a revision form that all was send 1. Coordinate the number of bedrooms on energy calculations and floor plan per FBC 6th ed. 107.1 The Den has closets and is considered a bedroom by code. J. Hindman 986-3784. | |||
| MECH | COMPLETE | 08/30/2018 | 09/06/2018 |
| Note: Released By: JHINDMAN | |||
| ZON | COMPLETE | 08/23/2018 | 08/23/2018 |
| Note: Released By: AMOBLEY | |||
| SW1 | COMPLETE | 08/23/2018 | 08/29/2018 |
| Note: Released By: JHINDMAN | |||
| MECH | HOLD | 08/23/2018 | 08/29/2018 |
| Note: Held By: JHINDMAN 1. Coordinate the number of bedrooms on energy calculations and floor plan per FBC 6th ed. 107.1 The Den has closets and is considered a bedroom by code. | |||
| BLD | COMPLETE | 08/22/2018 | 08/22/2018 |
| Note: Released By: JHINDMAN | |||
| BLD | HOLD | 08/15/2018 | 08/21/2018 |
| Note: Held By: JHINDMAN 1. On page A-3 and A-4 provide a roof underlayment that complies with the 6th ed. FBC R905. J. Hindman 986-3784. | |||
| ELEC | COMPLETE | 08/15/2018 | 08/16/2018 |
| Note: Released By: DREWIS | |||
| ENGIN1 | COMPLETE | 08/15/2018 | 08/15/2018 |
| Note: Released By: TBAKER | |||
| MECH | HOLD | 08/15/2018 | 08/21/2018 |
| Note: Held By: FREODICA 1. Coordinate the number of bedrooms on energy calculations and floor plan per FBC 6th ed. 107.1 2. Provide the new home address on enegy performace level (EPL) display card per FBCEC 6th ed. R401.3. 3. Coordinate the design location for climate zone using Daytona Beach, FL as shown on eenrgy calculation and not Orlando, FL as shown on equipment sizing calculation per FBCEC 6th ed. R301. 4. Provide balanced return air from the Den per FBCR 6th ed. M1602.3. F.Reodica -386-986-4734. | |||
| PLUM | COMPLETE | 08/15/2018 | 08/20/2018 |
| Note: Released By: FREODICA | |||
| SW1 | HOLD | 08/15/2018 | 08/16/2018 |
| Note: Held By: DREWIS Rear right side elevation of 23.9 allows flow from the adjacent lot, Tech. Manual Sec. 5 Eng. Standard 300.01 A1 c6. Daniel Rewis 986-4736 | |||
| UD1 | COMPLETE | 08/15/2018 | 08/22/2018 |
| Note: Released By: MBACON Gravity Sewer new homes This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. | |||
| ZON | HOLD | 08/15/2018 | 08/15/2018 |
| Note: Held By: AMOBLEY Landscaping... Must have shrubs wrapping corners and at least 4 shrubs along each interior side | |||
| URB | COMPLETE | 08/15/2018 | 08/16/2018 |
| Note: Released By: JBEAUDET |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 06/13/2019 |
| REINSPECTION FEE | ¤40.00 | 06/13/2019 |
| REINSPECTION FEE | ¤40.00 | 06/13/2019 |
| REINSPECTION FEE | ¤40.00 | 06/13/2019 |
| REINSPECTION FEE | ¤40.00 | 06/13/2019 |
| REINSPECTION FEE | ¤40.00 | 06/13/2019 |
| REINSPECTION FEE | ¤40.00 | 12/11/2018 |
| REINSPECTION FEE | ¤40.00 | 12/11/2018 |
| ELECTRIC FEE | ¤62.04 | 12/11/2018 |
| REVISION | ¤40.00 | 12/11/2018 |
| REINSPECTION FEE | ¤40.00 | 10/25/2018 |
| SITE PLAN 20 | ¤20.00 | 09/12/2018 |
| SURCHARGE FS 533.721 | ¤15.72 | 09/12/2018 |
| SURCHARGE - FS 468.631 | ¤23.59 | 09/12/2018 |
| STORM WATER PERMIT FEES | ¤80.00 | 09/12/2018 |
| 3% TRANS IMPACT FEE CREDIT | (¤89.43) | 09/12/2018 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.56) | 09/12/2018 |
| IMPACT FEE FIRE | ¤218.79 | 09/12/2018 |
| IMPACT FEE PARKS | ¤849.24 | 09/12/2018 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 09/12/2018 |
| IMPACT FEE TRANSPORTATION | ¤2,981.00 | 09/12/2018 |
| MECHANICAL FEE | ¤253.20 | 09/12/2018 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 09/12/2018 |
| PLAN CHECK FEE | ¤128.80 | 09/12/2018 |
| PLUMBING FEE | ¤253.20 | 09/12/2018 |
| ADMIN FEE | ¤20.00 | 09/12/2018 |
| ELECTRIC FEE | ¤253.20 | 09/12/2018 |
| NEW RESIDENTIAL INSPECTIONS | ¤644.00 | 09/12/2018 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,681.31 |