Permit #2018080581

Permit Details

Status: COED

Parcel Id: 07-11-31-7025-000C0-013B
Block: 000C0
Subdivision: 1228 - SOUTHWEST QUADRANT
Job Phone: (386)445-9393
Location Address: 10 CYPRESS POINT PKWY
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 12/03/2018
NOC: Unknown
Applicant name: ANTONIO JR AMARAL
Owner: ANTOMAR OF PALM COAST LLC

Address

13 UTILITY DRIVE

PALM COAST, FL 32137

Lot: 013B
Contracted Stated Job Value: ¤2,300.00
Job Description: UNIT # 101 "AMARAL BAKERY"
Type: CN

Contractor

AMARAL HOMES & POOLS, LLC
Status Location Address State License Number Phone
ACTIVE

13 Utility Drive

PALM COAST, FL 32137

CBC058062 (Exp: 08/31/2026) (386)445-9393

Sub Contractors

JOHN ROBERT BLEVINS JR
Status Location Address State License Number Phone Fax
ACTIVE

17 PORWYN LANE

PALM COAST, FL 32164

CAC1816125 (Exp: 08/31/2026) 386-585-8283 386-263-2096
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488
STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472

Inspection History

Type Request Date Result Inspector
HVAC FINAL 04/11/2019 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
BUILDING FINAL 04/11/2019 FINAL APPROVED WMILLER
FIRE FINAL 04/11/2019 FINAL APPROVED WMILLER
Note: THIS IS A REINSPECTION
FRAMING 02/25/2019 APPROVED JHINDMAN
HVAC FINAL 02/25/2019 PARTIALLY APPROVED JHINDMAN
Note: revise plans to show baxteroven and venting.
ELECTRIC FINAL 02/25/2019 APPROVED RMARTIN
ELECTRIC FINAL 02/19/2019 CANCELLED BY APPLICANT RMARTIN
Note: CANCELLED BY CONTRACTOR
ELECTRIC FINAL 02/08/2019 Disapproved -FEE REQUIRED RMARTIN
Note: THE APPROVED PANEL SCHEDULE STILL DOES NOT MATCH WHAT IS INSTALLED, NEED APPROVED REVISION OR MAKE THE JOB LOOK LIKE THE APPROVED PLAN, CIRCLED ISSUES ON BLUE PRINT
HVAC FINAL 02/08/2019 Disapproved -FEE REQUIRED JHINDMAN
Note: The Baxter oven requires an exhaust hood per the manufacturers note and code. It is not a direct vent appliance.Provide a revised plan for the hood and oven 6th ed. FBC 107.4.
U-GREASE INTERCEPTOR FLOW/DYE TESTED 02/08/2019 APPROVED JNICHOLS
U - UTILITY COMMERCIAL FINAL 02/08/2019 FINAL APPROVED JNICHOLS
FIRE FINAL 02/08/2019 Disapproved - NO FEE JHINDMAN
Note: The Baxter oven requires an exhaust hood per the manufacturers note and code. It is not a direct vent appliance.Provide a revised plan for the hood and oven 6th ed. FBC 107.4.
HVAC FINAL 02/07/2019 Disapproved - NO FEE JHINDMAN
Note: building locked 1 p.m. 6th ed. FBC 110.1.
PLUMBING FINAL 02/07/2019 APPROVED - AS NOTED JGIBSON
Note: LOOKED AT THIS INSPECTION ON 2/5/19
HVAC FINAL 02/01/2019 Disapproved -FEE REQUIRED JHINDMAN
Note: 1. Exhaust fan in restroom does not function. 2. registers missing in restroom. 6th ed. FBC 110.5.
PLUMBING FINAL 02/01/2019 Disapproved -FEE REQUIRED JGIBSON
Note: NEED FLUSH HANDLE FOR ''ADA'' BATHROOM TO THE OPEN SIDE MISSING ESSCUSSIONS ON WATER LINES AND MISSING ''AAV'' AT SINK NEAR COUNTER AT FRONT
ELECTRIC FINAL 02/01/2019 Disapproved -FEE REQUIRED RMARTIN
Note: NEED ARC SHIELDS ON ALL OUTLETS THAT MEET NEC 314.20, PANEL SCHEDULE NEEDS TO MATCH APPROVED PLAN PLAN ALSO CALLS FOR GFCI EVERYWHERE, CIRCLED ON PLAN
FRAMING 12/20/2018 PARTIALLY APPROVED MWILLIAMS
Note: Must provide framing revision for conversion from metal to wood suds on center partition wall. Wood studs are 16"oC with fireblocking double top plate and securely fastened top and bottom
PLUMBING 2ND ROUGH 12/19/2018 APPROVED - AS NOTED JGIBSON
Note: THIS INSPECTION WAS DONE WITH FIRST ROUGH PLUMBING INSPECTION YESTERDAY 12/18/18
PLUMBING FINAL 12/19/2018 CANCELLED BY APPLICANT WEB
PLUMBING 1ST ROUGH 12/18/2018 APPROVED - AS NOTED JGIBSON
Note: GREASE LINE AND GREASE TRAP ARE EXISISTING
ELECTRIC 2ND ROUGH 12/17/2018 APPROVED RMARTIN

Review History

Department Status Date In Date Out
MECH COMPLETE 04/05/2019 04/08/2019
Note: Released By: RLEE
MECH HOLD 04/03/2019 04/03/2019
Note: Held By: RLEE Provide exhaust fan capabale of minimujm 50cfm at 6 inches bove diverter upper collar per manufacturers specification for Baxter oven.
BLD COMPLETE 04/02/2019 04/03/2019
Note: Released By: JHINDMAN
BLD COMPLETE 02/05/2019 02/19/2019
Note: Released By: JHINDMAN
FI1 COMPLETE 11/29/2018 11/30/2018
Note: Released By: DREWIS Letter provided omitting range and oven.
UD1 COMPLETE 11/14/2018 11/19/2018
Note: Released By: CJOHNSON
FI1 HOLD 11/14/2018 11/27/2018
Note: Held By: DREWIS Hood permit application needed for range. Gas convection oven specifications do not show as meeting UL requirements, NFPA 96 ch. 4 and FBC Mechanical 507.1 exception 1. Daniel Rewis 986-4736
BLD COMPLETE 11/14/2018 11/27/2018
Note: Released By: RLEE
PLUM COMPLETE 11/14/2018 11/27/2018
Note: Released By: RLEE
UD1 HOLD 10/25/2018 11/02/2018
Note: Held By: CJOHNSON Provide plumbing plan. This will require at minimum a grease trap. This unit may already have a grease trap installed. An updated gresea interceptor exemption form will be required
BLD HOLD 10/25/2018 11/05/2018
Note: Held By: RLEE Exit doors to swing to the flow of exit access at kitchen rear door.
PLUM HOLD 10/25/2018 11/05/2018
Note: Held By: RLEE Provide plumbing layout and plumbing riser diagrams.
MECH COMPLETE 10/25/2018 11/08/2018
Note: Released By: RLEE
FI1 HOLD 10/25/2018 11/05/2018
Note: Held By: DREWIS Seperate hood permit needed for the range and panini grill supression system. Daniel Rewis 986-4736
BLD HOLD 08/23/2018 08/24/2018
Note: Held By: JHINDMAN 1. Provide a complete set of plans for the build out of the unit. Only Electrical plans were submitted. 6th ed. FBC 107.3.5. J. Hindman 986-3784.
ELEC COMPLETE 08/23/2018 08/24/2018
Note: Released By: JHINDMAN
FI1 HOLD 08/23/2018 08/24/2018
Note: Held By: JHINDMAN 1. Provide a Life Safety plan. 6th ed. FBC 107.3.5. J. Hindman 986-3784. A hood with suppression will be required for the gas range and the panini grill.
MECH HOLD 08/23/2018 08/24/2018
Note: Held By: JHINDMAN 1. Provide a complete set of plans for the build out of the unit. Only Electrical plans were submitted. 6th ed. FBC 107.3.5.
PLUM HOLD 08/23/2018 08/24/2018
Note: Held By: JHINDMAN 1. Provide a complete set of plans for the build out of the unit. Only Electrical plans were submitted. 6th ed. FBC 107.3.5.
UD1 HOLD 08/23/2018 08/24/2018
Note: Held By: CJOHNSON Provide plumbing plan. This will require at minimum a grease trap. This unit may already have a grease trap installed. An updated gresea interceptor exemption form will be required
ZON COMPLETE 08/23/2018 08/24/2018
Note: Released By: JGONZALEZ

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 04/10/2019
REINSPECTION FEE ¤40.00 04/10/2019
REINSPECTION FEE ¤40.00 04/10/2019
REINSPECTION FEE ¤40.00 04/10/2019
REINSPECTION FEE ¤40.00 04/10/2019
ADDITIONAL FEE ¤40.00 04/10/2019
ADMIN COMMERCIAL ¤60.00 12/03/2018
INSPECTION - COMMERCIAL ADD ¤50.00 12/03/2018
ELECTRIC FEE ¤61.80 12/03/2018
MECHANICAL FEE ¤61.80 12/03/2018
PLAN CHECK FEE ¤100.00 12/03/2018
PLUMBING FEE ¤61.80 12/03/2018
SITE PLAN 20 ¤20.00 12/03/2018
SURCHARGE FS 533.721 ¤3.65 12/03/2018
SURCHARGE - FS 468.631 ¤5.48 12/03/2018
Fees Total Due: ¤0.00 Total Paid: ¤664.53