I want to search for...
Permit #2018080581
Permit Details
Status: COED
| Parcel Id: 07-11-31-7025-000C0-013B |
| Block: 000C0 |
| Subdivision: 1228 - SOUTHWEST QUADRANT |
| Job Phone: (386)445-9393 |
| Location Address: 10 CYPRESS POINT PKWY |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 12/03/2018 |
| NOC: Unknown |
| Applicant name: ANTONIO JR AMARAL |
| Owner: ANTOMAR OF PALM COAST LLC |
|
Address 13 UTILITY DRIVE PALM COAST, FL 32137 |
| Lot: 013B |
| Contracted Stated Job Value: ¤2,300.00 |
| Job Description: UNIT # 101 "AMARAL BAKERY" |
| Type: CN |
Contractor
AMARAL HOMES & POOLS, LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
13 Utility Drive PALM COAST, FL 32137 |
CBC058062 (Exp: 08/31/2026) | (386)445-9393 |
Sub Contractors
JOHN ROBERT BLEVINS JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
17 PORWYN LANE PALM COAST, FL 32164 |
CAC1816125 (Exp: 08/31/2026) | 386-585-8283 | 386-263-2096 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 04/11/2019 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| BUILDING FINAL | 04/11/2019 | FINAL APPROVED | WMILLER |
| FIRE FINAL | 04/11/2019 | FINAL APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION | |||
| FRAMING | 02/25/2019 | APPROVED | JHINDMAN |
| HVAC FINAL | 02/25/2019 | PARTIALLY APPROVED | JHINDMAN |
| Note: revise plans to show baxteroven and venting. | |||
| ELECTRIC FINAL | 02/25/2019 | APPROVED | RMARTIN |
| ELECTRIC FINAL | 02/19/2019 | CANCELLED BY APPLICANT | RMARTIN |
| Note: CANCELLED BY CONTRACTOR | |||
| ELECTRIC FINAL | 02/08/2019 | Disapproved -FEE REQUIRED | RMARTIN |
| Note: THE APPROVED PANEL SCHEDULE STILL DOES NOT MATCH WHAT IS INSTALLED, NEED APPROVED REVISION OR MAKE THE JOB LOOK LIKE THE APPROVED PLAN, CIRCLED ISSUES ON BLUE PRINT | |||
| HVAC FINAL | 02/08/2019 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: The Baxter oven requires an exhaust hood per the manufacturers note and code. It is not a direct vent appliance.Provide a revised plan for the hood and oven 6th ed. FBC 107.4. | |||
| U-GREASE INTERCEPTOR FLOW/DYE TESTED | 02/08/2019 | APPROVED | JNICHOLS |
| U - UTILITY COMMERCIAL FINAL | 02/08/2019 | FINAL APPROVED | JNICHOLS |
| FIRE FINAL | 02/08/2019 | Disapproved - NO FEE | JHINDMAN |
| Note: The Baxter oven requires an exhaust hood per the manufacturers note and code. It is not a direct vent appliance.Provide a revised plan for the hood and oven 6th ed. FBC 107.4. | |||
| HVAC FINAL | 02/07/2019 | Disapproved - NO FEE | JHINDMAN |
| Note: building locked 1 p.m. 6th ed. FBC 110.1. | |||
| PLUMBING FINAL | 02/07/2019 | APPROVED - AS NOTED | JGIBSON |
| Note: LOOKED AT THIS INSPECTION ON 2/5/19 | |||
| HVAC FINAL | 02/01/2019 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: 1. Exhaust fan in restroom does not function. 2. registers missing in restroom. 6th ed. FBC 110.5. | |||
| PLUMBING FINAL | 02/01/2019 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: NEED FLUSH HANDLE FOR ''ADA'' BATHROOM TO THE OPEN SIDE MISSING ESSCUSSIONS ON WATER LINES AND MISSING ''AAV'' AT SINK NEAR COUNTER AT FRONT | |||
| ELECTRIC FINAL | 02/01/2019 | Disapproved -FEE REQUIRED | RMARTIN |
| Note: NEED ARC SHIELDS ON ALL OUTLETS THAT MEET NEC 314.20, PANEL SCHEDULE NEEDS TO MATCH APPROVED PLAN PLAN ALSO CALLS FOR GFCI EVERYWHERE, CIRCLED ON PLAN | |||
| FRAMING | 12/20/2018 | PARTIALLY APPROVED | MWILLIAMS |
| Note: Must provide framing revision for conversion from metal to wood suds on center partition wall. Wood studs are 16"oC with fireblocking double top plate and securely fastened top and bottom | |||
| PLUMBING 2ND ROUGH | 12/19/2018 | APPROVED - AS NOTED | JGIBSON |
| Note: THIS INSPECTION WAS DONE WITH FIRST ROUGH PLUMBING INSPECTION YESTERDAY 12/18/18 | |||
| PLUMBING FINAL | 12/19/2018 | CANCELLED BY APPLICANT | WEB |
| PLUMBING 1ST ROUGH | 12/18/2018 | APPROVED - AS NOTED | JGIBSON |
| Note: GREASE LINE AND GREASE TRAP ARE EXISISTING | |||
| ELECTRIC 2ND ROUGH | 12/17/2018 | APPROVED | RMARTIN |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 04/05/2019 | 04/08/2019 |
| Note: Released By: RLEE | |||
| MECH | HOLD | 04/03/2019 | 04/03/2019 |
| Note: Held By: RLEE Provide exhaust fan capabale of minimujm 50cfm at 6 inches bove diverter upper collar per manufacturers specification for Baxter oven. | |||
| BLD | COMPLETE | 04/02/2019 | 04/03/2019 |
| Note: Released By: JHINDMAN | |||
| BLD | COMPLETE | 02/05/2019 | 02/19/2019 |
| Note: Released By: JHINDMAN | |||
| FI1 | COMPLETE | 11/29/2018 | 11/30/2018 |
| Note: Released By: DREWIS Letter provided omitting range and oven. | |||
| UD1 | COMPLETE | 11/14/2018 | 11/19/2018 |
| Note: Released By: CJOHNSON | |||
| FI1 | HOLD | 11/14/2018 | 11/27/2018 |
| Note: Held By: DREWIS Hood permit application needed for range. Gas convection oven specifications do not show as meeting UL requirements, NFPA 96 ch. 4 and FBC Mechanical 507.1 exception 1. Daniel Rewis 986-4736 | |||
| BLD | COMPLETE | 11/14/2018 | 11/27/2018 |
| Note: Released By: RLEE | |||
| PLUM | COMPLETE | 11/14/2018 | 11/27/2018 |
| Note: Released By: RLEE | |||
| UD1 | HOLD | 10/25/2018 | 11/02/2018 |
| Note: Held By: CJOHNSON Provide plumbing plan. This will require at minimum a grease trap. This unit may already have a grease trap installed. An updated gresea interceptor exemption form will be required | |||
| BLD | HOLD | 10/25/2018 | 11/05/2018 |
| Note: Held By: RLEE Exit doors to swing to the flow of exit access at kitchen rear door. | |||
| PLUM | HOLD | 10/25/2018 | 11/05/2018 |
| Note: Held By: RLEE Provide plumbing layout and plumbing riser diagrams. | |||
| MECH | COMPLETE | 10/25/2018 | 11/08/2018 |
| Note: Released By: RLEE | |||
| FI1 | HOLD | 10/25/2018 | 11/05/2018 |
| Note: Held By: DREWIS Seperate hood permit needed for the range and panini grill supression system. Daniel Rewis 986-4736 | |||
| BLD | HOLD | 08/23/2018 | 08/24/2018 |
| Note: Held By: JHINDMAN 1. Provide a complete set of plans for the build out of the unit. Only Electrical plans were submitted. 6th ed. FBC 107.3.5. J. Hindman 986-3784. | |||
| ELEC | COMPLETE | 08/23/2018 | 08/24/2018 |
| Note: Released By: JHINDMAN | |||
| FI1 | HOLD | 08/23/2018 | 08/24/2018 |
| Note: Held By: JHINDMAN 1. Provide a Life Safety plan. 6th ed. FBC 107.3.5. J. Hindman 986-3784. A hood with suppression will be required for the gas range and the panini grill. | |||
| MECH | HOLD | 08/23/2018 | 08/24/2018 |
| Note: Held By: JHINDMAN 1. Provide a complete set of plans for the build out of the unit. Only Electrical plans were submitted. 6th ed. FBC 107.3.5. | |||
| PLUM | HOLD | 08/23/2018 | 08/24/2018 |
| Note: Held By: JHINDMAN 1. Provide a complete set of plans for the build out of the unit. Only Electrical plans were submitted. 6th ed. FBC 107.3.5. | |||
| UD1 | HOLD | 08/23/2018 | 08/24/2018 |
| Note: Held By: CJOHNSON Provide plumbing plan. This will require at minimum a grease trap. This unit may already have a grease trap installed. An updated gresea interceptor exemption form will be required | |||
| ZON | COMPLETE | 08/23/2018 | 08/24/2018 |
| Note: Released By: JGONZALEZ |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 04/10/2019 |
| REINSPECTION FEE | ¤40.00 | 04/10/2019 |
| REINSPECTION FEE | ¤40.00 | 04/10/2019 |
| REINSPECTION FEE | ¤40.00 | 04/10/2019 |
| REINSPECTION FEE | ¤40.00 | 04/10/2019 |
| ADDITIONAL FEE | ¤40.00 | 04/10/2019 |
| ADMIN COMMERCIAL | ¤60.00 | 12/03/2018 |
| INSPECTION - COMMERCIAL ADD | ¤50.00 | 12/03/2018 |
| ELECTRIC FEE | ¤61.80 | 12/03/2018 |
| MECHANICAL FEE | ¤61.80 | 12/03/2018 |
| PLAN CHECK FEE | ¤100.00 | 12/03/2018 |
| PLUMBING FEE | ¤61.80 | 12/03/2018 |
| SITE PLAN 20 | ¤20.00 | 12/03/2018 |
| SURCHARGE FS 533.721 | ¤3.65 | 12/03/2018 |
| SURCHARGE - FS 468.631 | ¤5.48 | 12/03/2018 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤664.53 |