I want to search for...
Permit #2018080950
Permit Details
Status: COED
| Parcel Id: 33-11-31-3061-00050-0030 |
| CONDITIONED SPACE: 2445 sqft |
| GARAGE: 686 sqft |
| SCREEN PORCH (SOLID ROOF) : 324 sqft |
| SCREEN PORCH (SOLID ROOF) : 42 sqft |
| Total Square Footage: 3497 sqft |
| Block: 00050 |
| Subdivision: 2108 - HIDDEN LAKES PHASE II - TOSCANA |
| Job Phone: 863-420-2100 |
| Location Address: 10 NEW LEATHERWOOD DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/12/2018 |
| NOC: RECORDED |
| Applicant name: YUVAL BOTANSKY |
| Owner: APPLIED BUILDING DEVELOPMENT OF ORLANDO - PC INC |
|
Address 131 CHADWICK DRIVE DAVENPORT, FL 33837 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤210,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
APPLIED BUILDING DEVELOPMENT COMPANY - OAKHILLS IN
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
131 CHADWICK DRIVE DAVENPORT, FL 33837 |
CRC1330762 (Exp: 08/31/2026) | 863-420-2100 | 386-517-6865 |
Sub Contractors
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| CANCEL |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2022) | 877-906-1113 |
TERRY HILE BURD
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO Box 180308 CASSELBERRY, FL 32707 |
CAC1814423 (Exp: 08/31/2024) | (407) 831-3600 | (407)831-2893 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
SANTOS L HERNANDEZ
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
946 SHADDICK DRIVE ORANGE CITY, FL 32763 |
CCC1328011 (Exp: 08/31/2026) | 386-218-4942 | 386-218-4937 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 09/20/2019 | APPROVED | MWILLIAMS |
| U-CROSS CONNECTION | 09/20/2019 | APPROVED | LFITZGERALD |
| ROW - FINAL APRON (AFTER POUR) | 09/20/2019 | APPROVED | KHOWELL |
| ROW - STORMWATER FINAL | 09/20/2019 | FINAL APPROVED | KHOWELL |
| U -UTILITY RESIDENTIAL FINAL | 09/20/2019 | FINAL APPROVED | LFITZGERALD |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 09/19/2019 | APPROVED | KHOWELL |
| FINAL SURVEY (OFFICE USE ONLY) | 09/19/2019 | APPROVED | KHOWELL |
| ELECTRIC - EARLY POWER | 09/17/2019 | APPROVED - AS NOTED | CPISCITELLI |
| Note: SPOKE TO DELL FPL RELEASED POWER 4:00 PER ROBERT | |||
| ROW- PRE-APRON (PRE-POUR) | 08/28/2019 | APPROVED | KHOWELL |
| Note: THIS IS A REINSPECTION | |||
| ROW- PAVER RESTRAINTS | 08/22/2019 | APPROVED | KHOWELL |
| ROW- PRE-APRON (PRE-POUR) | 08/22/2019 | PARTIALLY APPROVED | KHOWELL |
| Note: SIDEWALK AND APRON POUR PAVER UPPER | |||
| U - SEWER TIE IN | 08/14/2019 | APPROVED | JGIBSON |
| GRAVITY SEWER TEST | 08/14/2019 | APPROVED | JGIBSON |
| LATH/BRICK/ WATER BARRIER | 07/03/2019 | APPROVED | MWILLIAMS |
| INSULATION | 06/14/2019 | APPROVED | MWILLIAMS |
| ALL ROUGH | 06/11/2019 | APPROVED | MWILLIAMS |
| ROOF VALLEY & METAL | 05/31/2019 | APPROVED | WMILLER |
| ROOF SHEATHING | 05/14/2019 | APPROVED | MWILLIAMS |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/14/2019 | APPROVED | MWILLIAMS |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/10/2019 | Disapproved -FEE REQUIRED | WMILLER |
| Note: NEED APPROVED PLANS ON SITE FOR INSPECTION (PLANS ON SITE WERE OT APPROVED) | |||
| ROOF SHEATHING | 05/09/2019 | Disapproved -FEE REQUIRED | WMILLER |
| Note: NOT READY 1. MISSING ROOF DECKING AT VALLEY (RIGHT SIDE OF GARAGE) 2. MISSING EYEBROW DECKING 3. NEED TO PLACE BLOCKING WHERE H-CLIP IS DAMAGED (POINTED OUT TO FRAMER ONSITE) 4. NEED TO REMOVE SHINERS 5. MISSING FASTENERS AS REQUIRED AT BACK RIGHT HIP 6. NEED TO DRIVE UNDER DRIVEN NAILS | |||
| TIE BEAM / LINTEL | 04/26/2019 | APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION | |||
| ELECTRIC-TUG | 04/26/2019 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO SUSAN FPL RELEASED POWER 2:45 | |||
| TIE BEAM / LINTEL | 04/24/2019 | CANCELLED BY APPLICANT | MWILLIAMS |
| MONOLITHIC SLAB | 04/12/2019 | APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB | 04/11/2019 | Disapproved -FEE REQUIRED | WMILLER |
| Note: NO EVIDENCE OF TERMITE TREATMENT OR NOTICE OF INTENT TO TREAT, R318.1.7 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/08/2019 | APPROVED | JGIBSON |
| FOUND SURVEY APPROVED (OFFICE) | 04/03/2019 | APPROVED | JHINDMAN |
| FOOTER | 03/06/2019 | APPROVED | MWILLIAMS |
| FOOTER | 03/05/2019 | CANCELLED BY APPLICANT | WMILLER |
| Note: cancelled per Josh |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 03/29/2019 | 04/03/2019 |
| Note: Released By: JHINDMAN | |||
| BLD | COMPLETE | 01/08/2019 | 01/11/2019 |
| Note: Released By: JHINDMAN | |||
| BLD | HOLD | 12/21/2018 | 01/03/2019 |
| Note: Held By: JHINDMAN Provide a digitally signed and sealed plan or letter. Digital signatures must comply with Florida Statues Chapter 481 and Florida Administrative Rule 61G1-16.005 for architects or Florida Statutes Chapter 471 and Florida Administrative Rule 61G15-23.003 for Engineers. The following statement must accompany a digital signature “This item has been electronically signed and sealed by (name) On (date) using a Digital Signature”. Certificate Authority services can be purchased through a third party certification authority to include, but not limited to: • • Entrust • • eTrust • • GeoTrust • • GlobalSign • • IdenTrust • • Verisign A digitally created image of the seal must be on the plans for printing purposes. J. Hindman 986-3784. | |||
| BLD | COMPLETE | 08/24/2018 | 08/28/2018 |
| Note: Released By: RLEE | |||
| ELEC | COMPLETE | 08/24/2018 | 08/28/2018 |
| Note: Released By: RLEE | |||
| ENGIN1 | COMPLETE | 08/24/2018 | 08/27/2018 |
| Note: Released By: TBAKER | |||
| MECH | COMPLETE | 08/24/2018 | 08/28/2018 |
| Note: Released By: RLEE | |||
| PLUM | COMPLETE | 08/24/2018 | 08/28/2018 |
| Note: Released By: RLEE | |||
| SW1 | COMPLETE | 08/24/2018 | 08/28/2018 |
| Note: Released By: RLEE | |||
| UD1 | COMPLETE | 08/24/2018 | 08/28/2018 |
| Note: Released By: LFITZGERALD Gravity Sewer new homes This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. The NFPA Clear Zone distance there can be no obstacles in front of the Hydrant and 7.5’ on the sides or 4’ behind. | |||
| ZON | COMPLETE | 08/24/2018 | 08/24/2018 |
| Note: Released By: TDOAK |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 08/23/2019 |
| REINSPECTION FEE | ¤40.00 | 08/23/2019 |
| REVISION | ¤40.00 | 04/11/2019 |
| EXTENSION | ¤40.00 | 04/11/2019 |
| REINSPECTION FEE | ¤40.00 | 04/11/2019 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.56) | 09/12/2018 |
| IMPACT FEE FIRE | ¤218.79 | 09/12/2018 |
| IMPACT FEE PARKS | ¤849.24 | 09/12/2018 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 09/12/2018 |
| IMPACT FEE TRANSPORTATION | ¤2,981.00 | 09/12/2018 |
| MECHANICAL FEE | ¤186.00 | 09/12/2018 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 09/12/2018 |
| PLAN CHECK FEE | ¤84.00 | 09/12/2018 |
| PLUMBING FEE | ¤186.00 | 09/12/2018 |
| SITE PLAN 20 | ¤20.00 | 09/12/2018 |
| SURCHARGE FS 533.721 | ¤11.02 | 09/12/2018 |
| SURCHARGE - FS 468.631 | ¤16.53 | 09/12/2018 |
| STORM WATER PERMIT FEES | ¤80.00 | 09/12/2018 |
| 3% TRANS IMPACT FEE CREDIT | (¤89.43) | 09/12/2018 |
| NEW RESIDENTIAL INSPECTIONS | ¤420.00 | 09/12/2018 |
| ADMIN FEE | ¤20.00 | 09/12/2018 |
| ELECTRIC FEE | ¤186.00 | 09/12/2018 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤8,937.11 |