I want to search for...

Permit #2018090032

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-00380-0020
CONDITIONED SPACE: 2347 sqft
GARAGE: 412 sqft
SCREEN PORCH (SOLID ROOF) : 240 sqft
OPENED PORCH (WITH ROOF) : 72 sqft
Total Square Footage: 3071 sqft
Block: 00380
Subdivision: -
Job Phone: 386-960-7720
Location Address: 3 EASTWOOD DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/09/2018
NOC: RECORDED
Applicant name: LAWRENCE FRED SIETSMA
Owner: AVTEC HOMES INC

Address

STE 600

PALM BAY, FL 32907

Address

1663 GEORGIA STREET NE

PALM BAY, FL 32907

Lot: 0020
Contracted Stated Job Value: ¤230,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

AVTEC HOMES INC
Status Location Address State License Number Phone
CANCEL

2405 E GRAVES AVE

ORANGE CITY, FL 32763

CRC041905 (Exp: 08/31/2024) 386-960-7720

Sub Contractors

DOUGLAS EDWARD RICHARDS
Status Location Address State License Number Phone Fax
INACTIVE

108 E INDIANA AVENUE

DELAND, FL 32724

CCC1328824 (Exp: 08/31/2024) 386-736-4226 386-740-0535
STEVEN JAY SMITH
Status Location Address State License Number Phone
INACTIVE

104 West Cedar Avenue

Orange City, FL 32763

EC0001542 (Exp: 08/31/2022) (386)775-7776
RUSSELL J CARTER
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 302

DELAND, FL 32721

CFC1425938 (Exp: 08/31/2026) 386-736-4220 386-736-4219
BRUCE R BOLTON
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

1982 SR 44

NEW SMYRNA BEACH, FL 32168

SUITE 357

NEW SMYRNA BEACH, FL 32168

CAC1817407 (Exp: 08/31/2022) 386-216-5975 386-402-4191

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 04/29/2019 FINAL APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROW - FINAL INSPECTION 04/26/2019 FINAL APPROVED KHOWELL
Note: THIS IS A REINSPECTION ASPHALT PATCH IS SCHEDULED TO BE DONE TODAY
BLD - BUILDING FINAL 04/26/2019 Disapproved -FEE REQUIRED DROCKWELL
Note: Attic access cover must be rated for flame spread /
ROW - FINAL INSPECTION 04/24/2019 Disapproved - NO FEE KHOWELL
Note: REPAIR ROAD DAMAGE RIGHT OF DRIVEWAY, ALSO WANT TO SEE HOW GRADES WORK WHEN IT RAINS AND SEE IF HOME TO THE RIGHT IS BEING IMPACTED WITH RUN OFF FROM THIS PROPERTY
ROW - FINAL APRON (AFTER POUR) 04/23/2019 APPROVED - AS NOTED KHOWELL
Note: FINISH SAW CUT OVER CULVERT PIPES AND NEED FINAL CITY APPROVED SURVEY TO VERIFY CULVERT INVERT ELEVATIONS
U -UTILITY RESIDENTIAL FINAL 04/23/2019 FINAL APPROVED AHALL
FINAL SURVEY (OFFICE USE ONLY) 04/18/2019 APPROVED RLEE
ROW - FINAL APRON (AFTER POUR) 03/28/2019 CANCELLED BY APPLICANT WEB
U - SEWER TIE IN 03/21/2019 APPROVED JGIBSON
GRAVITY SEWER TEST 03/21/2019 APPROVED JGIBSON
ROW- PRE-APRON (PRE-POUR) 03/20/2019 APPROVED - AS NOTED KHOWELL
Note: It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist READY TO POUR upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete. ADD FORMS TO THE ENDS OF THE MITERS SO CONCRETE DOES NOT GO UNDER INTO THE SWALE
PROJECT STATUS (OFFICE USE) 03/19/2019 APPROVED - AS NOTED KHOWELL
Note: MET ON SITE WITH BUILDER TO GO OVER DRIVEWAY FORM WORK
ROW- PRE-APRON (PRE-POUR) 03/18/2019 Disapproved -FEE REQUIRED KHOWELL
Note: THE ROAD FORM BOARDS NOT ALLOWED TO BE PLACED WHERE CONCRETE WILL BE POURD INTO THE ROADWAY. THE CULVERT PIPE ON THE RIGHT SIDE IS OUT OF TOLERANCE A MAXIMUM OF 0.1' OF SLOPED ALLOWED ACROSS THE PIPE. THE MITERED END SECTIONS NOT FORMED TO CITY STANADARD DRIVEWAY DETAIL 18" FROM THE SIDE OF THE PIPE AT THE TOP AND 9" FROM THE SIDE AT THE BOTTOM. THE FOOTERS ARE REQUIIRED TO BE DUG OUT A MINIMUM OF 3" UNDER THE CULVERT AND 6" DEEP. THA ROAD FORMS ARE REQUIRED TO FOLLOW THE EXISTING EDGE OF PAVEMENT AND FOLLOW THE RADIUS. THE CULVERT PIPES ARE REQUIRED TO BE DUG OUT HALK WAY DOWN THE PIPE SEE STANDARD DETAIL. CULVERT PIPE REQUIRED TO BE 8' FROM EXISTING EDGE OF PAVEMENT. REBAR FOR FOOTERS NOT ON SITE
U - SEWER TIE IN 03/12/2019 CANCELLED BY APPLICANT WEB
ELECTRIC - EARLY POWER 03/12/2019 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED POWER 10:45
GRAVITY SEWER TEST 03/12/2019 CANCELLED BY APPLICANT WEB
INSULATION 01/16/2019 APPROVED DROCKWELL
LATH/BRICK/ WATER BARRIER 01/11/2019 APPROVED DROCKWELL
ALL ROUGH 01/08/2019 APPROVED DROCKWELL
ROOF VALLEY & METAL 12/21/2018 APPROVED DROCKWELL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/19/2018 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/18/2018 Disapproved -FEE REQUIRED DROCKWELL
Note: Girder trusses require 2 straps...se repair detail/Provide solid blocking along flat top trusses..OSB 7/16 cannot span more than 24in
TIE BEAM / LINTEL 12/03/2018 APPROVED DROCKWELL
FOUND SURVEY APPROVED (OFFICE) 11/29/2018 APPROVED DREWIS
MONOLITHIC SLAB 11/19/2018 APPROVED RLEE
MONOLITHIC SLAB 11/16/2018 CANCELLED BY APPLICANT WEB
PLUMBING 1ST ROUGH UNDERGROUND 11/14/2018 APPROVED JGIBSON

Review History

Department Status Date In Date Out
SW1 COMPLETE 04/17/2019 04/18/2019
Note: Released By: RLEE Final S
SW1 COMPLETE 11/29/2018 11/29/2018
Note: Released By: DREWIS Foundation Survey
ZON COMPLETE 10/03/2018 10/03/2018
Note: Released By: AMOBLEY
ZON HOLD 09/26/2018 09/26/2018
Note: Held By: AMOBLEY Please revise landscape plan showing the driveway change Please show that the stone on each side of house will wrap corners at least two feet
MECH COMPLETE 09/26/2018 10/02/2018
Note: Released By: JHINDMAN
BLD COMPLETE 09/26/2018 10/02/2018
Note: Released By: JHINDMAN
UD1 COMPLETE 09/26/2018 10/02/2018
Note: Released By: MBACON PEP Tank areas new home This is a PEP Tank area. The Pep Panel will be placed 5 feet from the front corner of the building on the same side of the building as the PEP tank that is marked on the Utility marked Site plan. Make sure the electrician places the PEP power wire between 3 feet and 5 feet from the ground. The plumber should exit the slab with the sewer pipe on the side of the building the tank will be on and matching the utility marked site plan, this will reduce any piping under driveways or sidewalks and minimize the fall required. The sewer tie-in inspection must be called in the day before the tie-in. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in visual inspection so he can witness the tie-in. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
SWALE COMPLETE 09/05/2018 09/12/2018
Note: Released By: TBAKER
BLD HOLD 09/04/2018 09/10/2018
Note: Held By: JHINDMAN 1. Provide an exterior wall finish that complies with the 6th ed. FBC R 703. (stucco).Code does not define Cementitius coating. J. Hindman 986-3784.
ELEC COMPLETE 09/04/2018 09/10/2018
Note: Released By: JHINDMAN
ENGIN1 COMPLETE 09/04/2018 09/05/2018
Note: Released By: TBAKER
MECH HOLD 09/04/2018 09/10/2018
Note: Held By: JHINDMAN 1. Provide missing builders signatures on the energy form R405-2017 page 1 and the Energy Performance display card. J. Hindman 986-3784.
PLUM COMPLETE 09/04/2018 09/10/2018
Note: Released By: JHINDMAN
SW1 COMPLETE 09/04/2018 09/10/2018
Note: Released By: JHINDMAN
UD1 HOLD 09/04/2018 09/11/2018
Note: Held By: MBACON PEP Panel not shown on electrical plans PEP Panel is not shown in the electrical plan. Submit a new electrical plan showing PEP Panel on the building on the same side of the building as indicated in the Utility marked site plan.
ZON HOLD 09/04/2018 09/05/2018
Note: Held By: AMOBLEY Banding/stone must wrap corners at least 2ft Can not have an office in a single family residence (change room name on plans) Maximum driveway width can not exceed 35ft and it must arc more to be a circular driveway

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 04/29/2019
REINSPECTION FEE ¤40.00 03/19/2019
REINSPECTION FEE ¤40.00 12/18/2018
NEW RESIDENTIAL INSPECTIONS ¤580.00 10/09/2018
SITE PLAN 20 ¤20.00 10/09/2018
SURCHARGE FS 533.721 ¤14.38 10/09/2018
SURCHARGE - FS 468.631 ¤21.57 10/09/2018
STORM WATER PERMIT FEES ¤80.00 10/09/2018
3% TRANS IMPACT FEE CREDIT (¤48.96) 10/09/2018
ADMIN FEE ¤20.00 10/09/2018
ELECTRIC FEE ¤234.00 10/09/2018
3% FIRE IMPACT FEE CREDIT (¤6.56) 10/09/2018
IMPACT FEE FIRE ¤218.79 10/09/2018
IMPACT FEE PARKS ¤849.24 10/09/2018
IMPACT FEE SCHOOL ¤3,600.00 10/09/2018
IMPACT FEE TRANSPORTATION ¤1,632.00 10/09/2018
MECHANICAL FEE ¤234.00 10/09/2018
3% PARKS IMPACT FEE CREDIT (¤25.48) 10/09/2018
PLAN CHECK FEE ¤116.00 10/09/2018
PLUMBING FEE ¤234.00 10/09/2018
Fees Total Due: ¤0.00 Total Paid: ¤7,892.98