I want to search for...

Permit #2018100133

Permit Details

Status: FINAL

Parcel Id: 05-11-31-5918-00000-0450
Block: 00000
Subdivision: 2244 - VILLAGE AT PALM COAST PH 1
Job Phone: 386-566-7804
Location Address: 1 VILLAGE POINT
Type: DR - DRIVEWAY
Issue Date: 10/10/2018
NOC: RECORDED
Applicant name: ERIC KACHNYCZ
Owner: ABBOTTS, GLENN D & LORI L

Address

1 VILLAGE POINT

PALM COAST, FL 32137

Lot: 0450
Contracted Stated Job Value: ¤7,700.00
Job Description: Install paver driveway and walkway
Type: CN

Contractor

DONE RIGHT SINCE 1985
Status Location Address Phone
ACTIVE

1405 KINGS ESTATE RD

ST AUGUSTINE, FL 32086

(904) 533-6373

Inspection History

Type Request Date Result Inspector
ROW- PAVER RESTRAINTS 02/19/2019 APPROVED RGROSS
ROW - FINAL APRON (AFTER POUR) 11/15/2018 APPROVED RGROSS
ROW - FINAL INSPECTION 11/15/2018 FINAL APPROVED RGROSS
U -UTILITY RESIDENTIAL FINAL 11/15/2018 FINAL APPROVED JNICHOLS
ROW- PRE-APRON (PRE-POUR) 10/29/2018 APPROVED - AS NOTED RGROSS
Note: JUST NEEDS A LITTLE MORE COMPACTION IN THE ROW BEFORE PAVERS ARE PLACED. EDGE RESTRAINTS READY TO POUR. PAVERS APPROVED TO BE PLACED.
ROW- PAVER RESTRAINTS 10/25/2018 Disapproved - NO FEE KHOWELL
Note: SEE PRE-POUR NOTES
ROW- PRE-APRON (PRE-POUR) 10/25/2018 Disapproved -FEE REQUIRED KHOWELL
Note: FORMS ARE NOT 18' WIDE AND ARE GOING UP AND DOWN, NEEDS TO BE A CONSISTENT SLOPE FROM GARAGE TO THE CURB. THE LEFT APRON FLARE IS TO WIDE. MOVE SPRINKLER OUT OF THE PAVER RESTRAINT PAD AREA. DIG HOLES IN R.O.W. FOR BASE THICKNESS INSPECTION ALSO
ROW- PRE-APRON (PRE-POUR) 10/19/2018 Disapproved -FEE REQUIRED CTROHA
Note: THE CITY REQUIRES 12" OF BASE IN THE ROW SEE PAVER DETAIL

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 10/03/2018 10/08/2018
Note: Released By: TBAKER
SW1 COMPLETE 10/03/2018 10/08/2018
Note: Released By: DREWIS
UD1 COMPLETE 10/03/2018 10/08/2018
Note: Released By: LFITZGERALD All Concrete, Driveways, Pavers, Pools / Sidewalks ETC. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. The NFPA Clear Zone distance there can be no obstacles in front of the Hydrant and 7.5’ on the sides or 4’ behind.
ZON COMPLETE 10/03/2018 10/03/2018
Note: Released By: AMOBLEY

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 02/18/2019
REINSPECTION FEE ¤40.00 02/18/2019
SITE PLAN 20 ¤20.00 10/10/2018
SURCHARGE FS 533.721 ¤2.00 10/10/2018
SURCHARGE - FS 468.631 ¤2.00 10/10/2018
STORM WATER PERMIT FEES ¤40.00 10/10/2018
ADMIN FEE ¤20.00 10/10/2018
Fees Total Due: ¤0.00 Total Paid: ¤164.00