Permit #2018100158

Permit Details

Status: COED

Parcel Id: 07-11-31-7026-00730-0460
CONDITIONED SPACE: 1502 sqft
OPENED PORCH (WITH ROOF) : 70 sqft
OPENED PORCH (WITH ROOF) : 234 sqft
GARAGE: 436 sqft
Total Square Footage: 2242 sqft
Block: 00730
Subdivision: 2153 - SECTION 26-PINE GROVE
Job Phone: 386-447-4151
Location Address: 26 PITT LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/13/2018
NOC: RECORDED
Applicant name: GENE WARREN SLONE
Owner: FLORIDA GREEN CONSTRUCTION

Address

50 LEANNI WAY

PALM COAST, FL 32137

Address

UNIT C-1

PALM COAST, FL 32137

Lot: 0460
Contracted Stated Job Value: ¤200,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

FLORIDA GREEN CONSTRUCTION INC.
Status Location Address State License Number Phone
INACTIVE

870 E RETTA STREET

DELEON SPRINGS, FL 32130

CBC1260957 (Exp: 08/31/2026) 407-580-2657

Sub Contractors

GREGG A MCANALLY
Status Location Address State License Number Phone
INACTIVE

3370 AGRICULTURAL CENTER DRIVE

PALM COAST, FL 32092

CAC1815760 (Exp: 08/31/2022) 904-829-8898
OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
JOHN EDWARD GAMBONE
Status Location Address Mailing Address State License Number Phone
ACTIVE

15 HARGROVE LN

PALM COAST, FL 32137

1G

PALM COAST, FL 32137

EC13006037 (Exp: 08/31/2026) 386-586-9144
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/13/2019 FINAL APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 06/11/2019 Disapproved -FEE REQUIRED JCOLASANTI
Note: guest bath faucet leaks,...need water hammer at dishwasher line
ROW - FINAL APRON (AFTER POUR) 06/10/2019 APPROVED KHOWELL
ROW - STORMWATER FINAL 06/10/2019 FINAL APPROVED KHOWELL
U -UTILITY RESIDENTIAL FINAL 06/10/2019 FINAL APPROVED LFITZGERALD
ROW FIELD SURVEY /GRADING CERTIFICATION 06/07/2019 APPROVED KHOWELL
Note: THIS IS A REINSPECTION
ROW FIELD SURVEY /GRADING CERTIFICATION 05/30/2019 Disapproved - NO FEE KHOWELL
Note: LOW AREA NOTED IN FINAL FIELD SURVEY HAS NOT BEEN FIXED
FINAL SURVEY (OFFICE USE ONLY) 05/30/2019 APPROVED CTROHA
Note: THIS IS A REINSPECTION
FINAL SURVEY (OFFICE USE ONLY) 05/23/2019 Disapproved - NO FEE CTROHA
Note: The drainage conveyance runs over the pep. This is prohibited because of storm water intrusion into the sewer system Low area re-establish drainage on the left back corner of the house ***See Final Survey Field Markup****
FINAL SURVEY (OFFICE USE ONLY) 05/20/2019 Disapproved - NO FEE RGROSS
Note: CULVERT ELEVATIONS OUT OF TOLERANCE. SEE SWALE PLAN. CULVERT SIZE TOO SMALL. SEE ATTACHED SURVEY MARKUP.
ELECTRIC - EARLY POWER 04/25/2019 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED POWER 11:40
ROW- PRE-APRON (PRE-POUR) 04/05/2019 APPROVED - AS NOTED KHOWELL
Note: It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist READY TO POUR upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete. ADJUST UPPER FORMS AS NEEDED SO ALL ARE THE SAME DISTANCE OFF THE EDGE OF THE CULVERT PIPE
U - SEWER TIE IN 03/11/2019 APPROVED JGIBSON
GRAVITY SEWER TEST 03/11/2019 APPROVED JGIBSON
INSULATION 02/21/2019 APPROVED DROCKWELL
INSULATION 02/20/2019 Disapproved -FEE REQUIRED WMILLER
Note: MISSING UNSULATION AT BLOCK OVER ENTRY AND BACK RIGHT BEDROOM
LATH/BRICK/ WATER BARRIER 02/12/2019 APPROVED DROCKWELL
ALL ROUGH 02/08/2019 APPROVED JHINDMAN
ROOF VALLEY & METAL 01/28/2019 APPROVED MWILLIAMS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/25/2019 APPROVED MWILLIAMS
TIE BEAM / LINTEL 01/09/2019 APPROVED MWILLIAMS
TIE BEAM / LINTEL 01/08/2019 Disapproved -FEE REQUIRED JCOLASANTI
Note: CHANGES IN HEIGHT R609.2.5 AND FIGURE 609.2.5 UPPER AND LOWER BOND BEAMS MUST BE CONTINUOUS, HAVE VERTICLE STEEL AND GROUTED SOLID AND MUST HAVE A FILLED CELL UNDER EACH CELL ADJOINING CHANGES IN HEIGHT (garage block change of height)
FOUND SURVEY APPROVED (OFFICE) 01/07/2019 APPROVED JHINDMAN
MONOLITHIC SLAB 12/19/2018 APPROVED MWILLIAMS
MONOLITHIC SLAB 12/18/2018 CANCELLED BY APPLICANT WEB
PLUMBING 1ST ROUGH UNDERGROUND 12/13/2018 APPROVED JGIBSON
ELECTRIC TEMP POLE 11/30/2018 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED POWER 3:20

Review History

Department Status Date In Date Out
SW1 COMPLETE 01/02/2019 01/07/2019
Note: Released By: JHINDMAN Foundation S
SW1 COMPLETE 11/06/2018 11/11/2018
Note: Released By: DREWIS
ZON COMPLETE 11/06/2018 11/07/2018
Note: Released By: AMOBLEY
ENGIN1 COMPLETE 11/06/2018 11/08/2018
Note: Released By: TBAKER
UTL COMPLETE 11/06/2018 11/08/2018
Note: Released By: LFITZGERALD PEP Tank areas new home This is a PEP Tank area. The Pep Panel will be placed 5 feet from the front corner of the building on the same side of the building as the PEP tank that is marked on the Utility marked Site plan. Make sure the electrician places the PEP power wire between 3 feet and 5 feet from the ground. The plumber should exit the slab with the sewer pipe on the side of the building the tank will be on and matching the utility marked site plan, this will reduce any piping under driveways or sidewalks and minimize the fall required. The sewer tie-in inspection must be called in the day before the tie-in. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in visual inspection so he can witness the tie-in. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. The NFPA Clear Zone distance there can be no obstacles in front of the Hydrant and 7.5’ on the sides or 4’ behind.
SW1 HOLD 11/02/2018 11/06/2018
Note: Held By: DREWIS Right side elevations do not provide a 5% slope within 10' of grade at the foundation wall, FBC R401.3. Daniel Rewis 986-4736
ZON COMPLETE 11/02/2018 11/05/2018
Note: Released By: TDOAK
SWALE COMPLETE 10/22/2018 11/06/2018
Note: Released By: TBAKER
ZON HOLD 10/19/2018 10/19/2018
Note: Held By: AMOBLEY Site plan should show all setbacks...Front, rear and sides from furthest point of structure to property line Flood map number is incorrect. Should be 12035C0139E
ENGIN1 COMPLETE 10/19/2018 10/22/2018
Note: Released By: TBAKER
ELEC COMPLETE 10/19/2018 10/24/2018
Note: Released By: DREWIS
SW1 HOLD 10/19/2018 10/24/2018
Note: Held By: DREWIS Provide a site plan with proposed elevations per Florida Building Code R401.3 and the COPC Tech. Manual Sec. 5 Eng. Standard. Daniel Rewis 986-4736
BLD COMPLETE 10/04/2018 10/10/2018
Note: Released By: JHINDMAN
ELEC HOLD 10/04/2018 10/08/2018
Note: Held By: DREWIS Additional GFCI needed in master bath or center the current one, NEC 2014 210.52D. Daniel Rewis 986-4736
ENGIN1 COMPLETE 10/04/2018 10/08/2018
Note: Released By: TBAKER Held By: TBAKER COPC does not allow nail and disc as site benchmarks. Acceptable benchmarks are nails in poles, hydrants, manhole covers. See COPC technical manual for additional info
MECH COMPLETE 10/04/2018 10/10/2018
Note: Released By: JHINDMAN
PLUM COMPLETE 10/04/2018 10/10/2018
Note: Released By: JHINDMAN
SW1 HOLD 10/04/2018 10/08/2018
Note: Held By: DREWIS Provide a site plan with proposed elevations per Florida Building Code R401.3 and the COPC Tech. Manual Sec. 5 Eng. Standard. Daniel Rewis 986-4736
UD1 COMPLETE 10/04/2018 10/10/2018
Note: Released By: MBACON PEP Tank areas new home This is a PEP Tank area. The Pep Panel will be placed 5 feet from the front corner of the building on the same side of the building as the PEP tank that is marked on the Utility marked Site plan. Make sure the electrician places the PEP power wire between 3 feet and 5 feet from the ground. The plumber should exit the slab with the sewer pipe on the side of the building the tank will be on and matching the utility marked site plan, this will reduce any piping under driveways or sidewalks and minimize the fall required. The sewer tie-in inspection must be called in the day before the tie-in. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in visual inspection so he can witness the tie-in. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
ZON HOLD 10/04/2018 10/05/2018
Note: Held By: AMOBLEY Survey should show all easements and total lot square footage Legal description is incorrect on survey Site plan should show all setbacks...Front, rear and sides from furthest point to property line

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 06/13/2019
REINSPECTION FEE ¤40.00 04/16/2019
REINSPECTION FEE ¤40.00 04/16/2019
CONTRACTOR CHANGE ¤40.00 04/16/2019
ELECTRIC FEE ¤180.00 11/13/2018
3% FIRE IMPACT FEE CREDIT (¤6.70) 11/13/2018
IMPACT FEE FIRE ¤223.38 11/13/2018
IMPACT FEE PARKS ¤849.24 11/13/2018
IMPACT FEE SCHOOL ¤3,600.00 11/13/2018
IMPACT FEE TRANSPORTATION ¤1,632.00 11/13/2018
MECHANICAL FEE ¤180.00 11/13/2018
3% PARKS IMPACT FEE CREDIT (¤25.48) 11/13/2018
PLAN CHECK FEE ¤80.00 11/13/2018
PLUMBING FEE ¤180.00 11/13/2018
ADMIN FEE ¤20.00 11/13/2018
NEW RESIDENTIAL INSPECTIONS ¤400.00 11/13/2018
SITE PLAN 20 ¤20.00 11/13/2018
SURCHARGE FS 533.721 ¤10.60 11/13/2018
SURCHARGE - FS 468.631 ¤15.90 11/13/2018
STORM WATER PERMIT FEES ¤80.00 11/13/2018
3% TRANS IMPACT FEE CREDIT (¤48.96) 11/13/2018
Fees Total Due: ¤0.00 Total Paid: ¤7,549.98