Permit #2018110069

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00430-0090
GARAGE: 394 sqft
OPENED PORCH (WITH ROOF) : 200 sqft
OPENED PORCH (WITH ROOF) : 11 sqft
CONDITIONED SPACE: 1478 sqft
Total Square Footage: 2083 sqft
Block: 00430
Subdivision: 2167 - SECTION 24-PINE GROVE
Job Phone: 386-960-7720
Location Address: 85 PRITCHARD DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/29/2018
NOC: RECORDED
Applicant name: LAWRENCE FRED SIETSMA
Owner: AVTEC HOMES INC

Address

620 MALABAR ROAD SE STE 5

PALM BAY, FL 32907

Lot: 0090
Contracted Stated Job Value: ¤205,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

AVTEC HOMES INC
Status Location Address State License Number Phone
CANCEL

2405 E GRAVES AVE

ORANGE CITY, FL 32763

CRC041905 (Exp: 08/31/2024) 386-960-7720

Sub Contractors

STEVEN JAY SMITH
Status Location Address State License Number Phone
INACTIVE

104 West Cedar Avenue

Orange City, FL 32763

EC0001542 (Exp: 08/31/2022) (386)775-7776
RUSSELL J CARTER
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 302

DELAND, FL 32721

CFC1425938 (Exp: 08/31/2026) 386-736-4220 386-736-4219
BRUCE R BOLTON
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

1982 SR 44

NEW SMYRNA BEACH, FL 32168

SUITE 357

NEW SMYRNA BEACH, FL 32168

CAC1817407 (Exp: 08/31/2022) 386-216-5975 386-402-4191
DOUGLAS EDWARD RICHARDS
Status Location Address State License Number Phone Fax
INACTIVE

108 E INDIANA AVENUE

DELAND, FL 32724

CCC1328824 (Exp: 08/31/2024) 386-736-4226 386-740-0535

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 04/26/2019 FINAL APPROVED JCOLASANTI
ROW - FINAL APRON (AFTER POUR) 04/26/2019 APPROVED RGROSS
ROW - FINAL INSPECTION 04/26/2019 FINAL APPROVED RGROSS
U -UTILITY RESIDENTIAL FINAL 04/26/2019 FINAL APPROVED LFITZGERALD
FINAL SURVEY (OFFICE USE ONLY) 04/25/2019 APPROVED JHINDMAN
ROW- PRE-APRON (PRE-POUR) 04/08/2019 APPROVED - AS NOTED KHOWELL
Note: THIS IS A REINSPECTION It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist READY TO POUR upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete. MET WITH CONTRACTOR ON SITE HE WILL ADJUST ALL THE UPPER MITERED END FORMS SO THEY ARE 18" OFF THE SIDE OF THE CULVERT PIPE
ROW- PRE-APRON (PRE-POUR) 04/03/2019 Disapproved -FEE REQUIRED KHOWELL
Note: TOP OF MITERED END IS NOT FORMED PER CITY STANDARD DETAIL. THE INSIDE OF THE ROAD FORM BOARD NEEDS TO LINE UP WITH THE EXISTING EDGE OF PAVEMENT.
U - SEWER TIE IN 03/27/2019 APPROVED JGIBSON
GRAVITY SEWER TEST 03/27/2019 APPROVED JGIBSON
ELECTRIC - EARLY POWER 03/25/2019 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED POWER 3:30
LATH/BRICK/ WATER BARRIER 03/05/2019 APPROVED WMILLER
Note: approved
LATH/BRICK/ WATER BARRIER 03/01/2019 Disapproved -FEE REQUIRED MWILLIAMS
Note: must provide proper weatherproofing at rear door ASTM approved wetherproofing must overlap blockwall/woo buck connecgion. Wood still visible around lathe area.
INSULATION 02/27/2019 APPROVED WMILLER
ALL ROUGH 02/22/2019 APPROVED MWILLIAMS
ROOF VALLEY & METAL 02/08/2019 APPROVED JHINDMAN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/01/2019 APPROVED WMILLER
Note: APPROVED
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/31/2019 CANCELLED BY APPLICANT WEB
TIE BEAM / LINTEL 01/25/2019 APPROVED JCOLASANTI
FOUND SURVEY APPROVED (OFFICE) 01/24/2019 APPROVED JHINDMAN
FOUND SURVEY APPROVED (OFFICE) 01/23/2019 CANCELLED BY INSPECTOR JMONTARULI
Note: Need to bring in foundation survey for review & approval
TIE BEAM / LINTEL 01/23/2019 CANCELLED BY INSPECTOR JMONTARULI
Note: Can't have this inspection until the foundation survey has been approved
MONOLITHIC SLAB 01/04/2019 APPROVED MWILLIAMS
MONOLITHIC SLAB 01/02/2019 Disapproved -FEE REQUIRED JCOLASANTI
Note: need termite sticker in box....need compaction test sticker in box
MONOLITHIC SLAB 12/28/2018 CANCELLED BY APPLICANT WEB
PLUMBING 1ST ROUGH UNDERGROUND 12/26/2018 APPROVED JGIBSON

Review History

Department Status Date In Date Out
SW1 COMPLETE 04/23/2019 04/25/2019
Note: Released By: JHINDMAN final
SW1 COMPLETE 01/22/2019 01/24/2019
Note: Released By: JHINDMAN Foundation S
BLD COMPLETE 11/16/2018 11/26/2018
Note: Released By: JHINDMAN
ZON COMPLETE 11/16/2018 11/16/2018
Note: Released By: AMOBLEY
ELEC COMPLETE 11/16/2018 11/26/2018
Note: Released By: DREWIS
SWALE COMPLETE 11/08/2018 11/28/2018
Note: Released By: TBAKER
BLD HOLD 11/02/2018 11/09/2018
Note: Held By: RLEE Provide signed and sealed plans.
ELEC HOLD 11/02/2018 11/06/2018
Note: Held By: DREWIS Provide signature of the desining engineer, FBC 107.1 Designing code reference shall be NEC 2014 and 2017 FBC 6th ed. Additional GFCI needed in laundry area, NEC 2014 210.52F. Daniel Rewis 986-4736
ENGIN1 COMPLETE 11/02/2018 11/08/2018
Note: Released By: TBAKER
MECH COMPLETE 11/02/2018 11/09/2018
Note: Released By: RLEE
PLUM COMPLETE 11/02/2018 11/09/2018
Note: Released By: RLEE
SW1 COMPLETE 11/02/2018 11/06/2018
Note: Released By: DREWIS
UD1 COMPLETE 11/02/2018 11/05/2018
Note: Released By: LFITZGERALD Gravity Sewer new homes This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. The NFPA Clear Zone distance there can be no obstacles in front of the Hydrant and 7.5’ on the sides or 4’ behind
ZON HOLD 11/02/2018 11/05/2018
Note: Held By: AMOBLEY Site plan does not match the blueprints and landscape plans The door pad and ac pad are in different locations

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 04/24/2019
REINSPECTION FEE ¤40.00 03/04/2019
REINSPECTION FEE ¤40.00 01/03/2019
NEW RESIDENTIAL INSPECTIONS ¤410.00 11/29/2018
SITE PLAN 20 ¤20.00 11/29/2018
SURCHARGE FS 533.721 ¤10.81 11/29/2018
SURCHARGE - FS 468.631 ¤16.22 11/29/2018
STORM WATER PERMIT FEES ¤80.00 11/29/2018
3% TRANS IMPACT FEE CREDIT (¤48.96) 11/29/2018
ADMIN FEE ¤20.00 11/29/2018
ELECTRIC FEE ¤183.00 11/29/2018
3% FIRE IMPACT FEE CREDIT (¤6.70) 11/29/2018
IMPACT FEE FIRE ¤223.38 11/29/2018
IMPACT FEE PARKS ¤849.24 11/29/2018
IMPACT FEE SCHOOL ¤3,600.00 11/29/2018
IMPACT FEE TRANSPORTATION ¤1,632.00 11/29/2018
MECHANICAL FEE ¤183.00 11/29/2018
3% PARKS IMPACT FEE CREDIT (¤25.48) 11/29/2018
PLAN CHECK FEE ¤82.00 11/29/2018
PLUMBING FEE ¤183.00 11/29/2018
Fees Total Due: ¤0.00 Total Paid: ¤7,531.51