Permit #2018110677

Permit Details

Status: COED

Parcel Id: 07-11-31-7029-00230-0190
CONDITIONED SPACE: 1875 sqft
GARAGE: 516 sqft
OPENED PORCH (WITH ROOF) : 48 sqft
OPENED PORCH (WITH ROOF) : 213 sqft
Total Square Footage: 2652 sqft
Block: 00230
Subdivision: 2209 - SECTION 29-ROYAL PALMS
Job Phone: 407-307-4753
Location Address: 39 RYLAND DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/05/2019
NOC: RECORDED
Applicant name: SHAWN VIRAG
Owner: BRITE PROPERTIES OF FLORIDA LLC

Address

619 EAST WASHINGTON

ORLANDO, FL 32801

Lot: 0190
Contracted Stated Job Value: ¤147,646.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

SHAWNTELLE CONSULTING AND DESIGN LLC
Status Location Address State License Number Phone
CANCEL

611 LARGOVISTA DR

OAKLAND, FL 34787

CBC1261160 (Exp: 08/31/2020) 407-307-4753

Sub Contractors

JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
JOSEPH H STRADA JR
Status Location Address State License Number Phone
CANCEL

3400 ST JOHNS PKWY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2022) 877-906-1113
ROBERT G DELLO RUSSO
Status Location Address State License Number Phone Fax
DECEASED

531 CODISCO WAY

SANFORD, FL 32771

CAC032448 (Exp: 08/31/2022) (407)831-2665 (407)333-3853

Inspection History

Type Request Date Result Inspector
ELECTRIC - EARLY POWER 03/19/2020 APPROVED BBEMBRY
ROW - FINAL APRON (AFTER POUR) 10/29/2019 APPROVED - AS NOTED KHOWELL
Note: CLEAN THE DIRT AND CONCRETE OUT OF THE CULVERT PIPE
ROW - STORMWATER FINAL 10/29/2019 FINAL APPROVED KHOWELL
U -UTILITY RESIDENTIAL FINAL 10/29/2019 FINAL APPROVED LFITZGERALD
BLD - BUILDING FINAL 08/08/2019 FINAL APPROVED JDELBONIS
ROW FIELD SURVEY /GRADING CERTIFICATION 07/25/2019 APPROVED - AS NOTED KHOWELL
Note: REMOVE BAHIA AND INSTALL ST. AUGUSTINE ON RIGHT AND LEFT NEIGHBORING LOTS AND BLIND SOD IN TO MATCH EXISTING YARD ELEVATIONS
FINAL SURVEY (OFFICE USE ONLY) 07/25/2019 APPROVED KHOWELL
ROW- PRE-APRON (PRE-POUR) 06/25/2019 APPROVED - AS NOTED KHOWELL
Note: It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist READY TO POUR upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete. ON SITE WITH TOM WILL MAKE ADJUSTMENTS THAT WAS TALKED ABOUT PRIOR TO POURING CONCRETE
U - SEWER TIE IN 05/14/2019 APPROVED JGIBSON
GRAVITY SEWER TEST 05/14/2019 APPROVED JGIBSON
LATH/BRICK/ WATER BARRIER 05/14/2019 APPROVED DROCKWELL
INSULATION 05/03/2019 APPROVED DROCKWELL
ALL ROUGH 04/30/2019 APPROVED - AS NOTED DROCKWELL
Note: Check master bath waste arm for proper pitch/Need 5ft head on sanitary....check at insulation
ROOF VALLEY & METAL 04/11/2019 APPROVED DROCKWELL
ELECTRIC-TUG 04/11/2019 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED POWER 3:20
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/10/2019 APPROVED - AS NOTED DROCKWELL
Note: Strip downcell forms for viewing
ELECTRIC-TUG 04/10/2019 Disapproved -FEE REQUIRED RMARTIN
Note: GROUND INSIDE METER IS NOT TIGHT, AS STATED ON PREVIOUS INSPECTION
ELECTRIC-TUG 03/27/2019 Disapproved -FEE REQUIRED RMARTIN
Note: GROUND INSIDE METER IS NOT TIGHT, GFCI OUTLET BOX NEEDS TO BE SECURED
TIE BEAM / LINTEL 03/27/2019 APPROVED MWILLIAMS
FOUND SURVEY APPROVED (OFFICE) 03/26/2019 APPROVED RLEE
MONOLITHIC SLAB 03/19/2019 APPROVED - AS NOTED DROCKWELL
Note: Prep the building pad properly before you begin formwork..FYI future pads.
PLUMBING 1ST ROUGH UNDERGROUND 03/14/2019 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 03/13/2019 Disapproved -FEE REQUIRED JGIBSON
Note: NEED TO HAVE CITY APPROVED PLANS ON SITE FOR ALL INSPECTIONS,

Review History

Department Status Date In Date Out
SW1 COMPLETE 03/20/2019 03/26/2019
Note: Released By: RLEE Foundation S
BLD COMPLETE 03/11/2019 03/18/2019
Note: Released By: JHINDMAN
ZON COMPLETE 01/28/2019 01/28/2019
Note: Released By: AMOBLEY
SWALE COMPLETE 01/09/2019 01/16/2019
Note: Released By: TBAKER
ZON HOLD 01/07/2019 01/08/2019
Note: Held By: AMOBLEY Residential homes shall provide foundation plantings consisting of sixteen (16) shrubs. On interior lots, eight (8) shrubs shall be planted in front of the home, and four (4) shrubs planted on each side of the home. Please specify shrub types and add additional shrubs along side. Should have at least 4 along the sides of home
ENGIN1 COMPLETE 01/07/2019 01/09/2019
Note: Released By: TBAKER
UD1 COMPLETE 01/07/2019 01/14/2019
Note: Released By: MBACON PEP Tank areas new home This is a PEP Tank area. The Pep Panel will be placed 5 feet from the front corner of the building on the same side of the building as the PEP tank that is marked on the Utility marked Site plan. Make sure the electrician places the PEP power wire between 3 feet and 5 feet from the ground. The plumber should exit the slab with the sewer pipe on the side of the building the tank will be on and matching the utility marked site plan, this will reduce any piping under driveways or sidewalks and minimize the fall required. The sewer tie-in inspection must be called in the day before the tie-in. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in visual inspection so he can witness the tie-in. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
SW1 COMPLETE 01/07/2019 01/11/2019
Note: Released By: JHINDMAN
ELEC COMPLETE 01/07/2019 01/11/2019
Note: Released By: JHINDMAN
BLD COMPLETE 11/20/2018 11/28/2018
Note: Released By: JHINDMAN
ELEC HOLD 11/20/2018 11/27/2018
Note: Held By: DREWIS Additional GFCI needed in the laundry area, NEC 2014 210.52F. Daniel Rewis 986-4736
ENGIN1 HOLD 11/20/2018 11/26/2018
Note: Held By: TBAKER No benchmark on survey Wrong street name on survey
MECH COMPLETE 11/20/2018 11/28/2018
Note: Released By: JHINDMAN
PLUM COMPLETE 11/20/2018 11/28/2018
Note: Released By: JHINDMAN
SW1 HOLD 11/20/2018 11/27/2018
Note: Held By: DREWIS Provide proposed survey elevations for stormwater flow in accordance with City of Palm Coast Tech. Manual Sec. 5 Eng. Standards 300. Provide proposed elevations for grade at the foundation wall and 10' away per Florida Building Code R401.3 Daniel Rewis 986-4736
UD1 HOLD 11/20/2018 11/27/2018
Note: Held By: LFITZGERALD PEP Panel not shown on electrical plans (Builder Electrical Plan - PEP Panel is not shown in the electrical plan. Submit a new electrical plan showing PEP Panel on the building on the same side of the building as indicated in the Utility marked site plans Also-PEP Tank areas new home This is a PEP Tank area. The Pep Panel will be placed 5 feet from the front corner of the building on the same side of the building as the PEP tank that is marked on the Utility marked Site plan. Make sure the electrician places the PEP power wire between 3 feet and 5 feet from the ground. The plumber should exit the slab with the sewer pipe on the side of the building the tank will be on and matching the utility marked site plan, this will reduce any piping under driveways or sidewalks and minimize the fall required. The sewer tie-in inspection must be called in the day before the tie-in. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in visual inspection so he can witness the tie-in. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap
ZON HOLD 11/20/2018 11/20/2018
Note: Held By: AMOBLEY Foundation Plantings... a. Residential homes shall provide foundation plantings consisting of sixteen (16) shrubs. On interior lots, eight (8) shrubs shall be planted in front of the home, and four (4) shrubs planted on each side of the home. On corner lots, six (6) shrubs shall be planted on each side of the home facing a street, and (4) shrubs planted on the interior side of the home. When the rear yard of a home faces a saltwater canal, lake, or golf course, an additional four (4) shrubs shall be planted along the rear of the home. b. All of these required shrubs shall be planted between two and one-half (2 ½) and eight (8) feet of the home’s foundation. c. The corners of the house shall be wrapped with shrubbery or have an understory tree planted there. Shrubbery shall be selected using varying heights to accent and soften walls. Ac pad must be screened with 7 gallon shrubs Please provide rear setback and total lot square footage on survey/site plan

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤40.00 08/13/2019
REINSPECTION FEE ¤40.00 08/13/2019
REINSPECTION FEE ¤40.00 08/13/2019
REINSPECTION FEE ¤40.00 08/13/2019
NEW RESIDENTIAL INSPECTIONS ¤480.00 02/05/2019
SITE PLAN 20 ¤20.00 02/05/2019
SURCHARGE FS 533.721 ¤12.28 02/05/2019
SURCHARGE - FS 468.631 ¤18.42 02/05/2019
STORM WATER PERMIT FEES ¤80.00 02/05/2019
3% TRANS IMPACT FEE CREDIT (¤48.96) 02/05/2019
ELECTRIC FEE ¤204.00 02/05/2019
3% FIRE IMPACT FEE CREDIT (¤6.70) 02/05/2019
IMPACT FEE FIRE ¤223.38 02/05/2019
IMPACT FEE PARKS ¤849.24 02/05/2019
IMPACT FEE SCHOOL ¤3,600.00 02/05/2019
IMPACT FEE TRANSPORTATION ¤1,632.00 02/05/2019
MECHANICAL FEE ¤204.00 02/05/2019
3% PARKS IMPACT FEE CREDIT (¤25.48) 02/05/2019
PLAN CHECK FEE ¤96.00 02/05/2019
PLUMBING FEE ¤204.00 02/05/2019
ADMIN FEE ¤20.00 02/05/2019
Fees Total Due: ¤0.00 Total Paid: ¤7,722.18