I want to search for...
Permit #2018110877
Permit Details
Status: COED
| Parcel Id: 07-11-31-7009-00170-0300 |
| CONDITIONED SPACE: 2351 sqft |
| GARAGE: 483 sqft |
| OPENED PORCH (WITH ROOF) : 88 sqft |
| OPENED PORCH (WITH ROOF) : 290 sqft |
| Total Square Footage: 3212 sqft |
| Block: 00170 |
| Subdivision: 2208 - SECTION 9-FLORIDA PARK |
| Job Phone: (386)446-5161 |
| Location Address: 11 FAIRBANK LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/17/2018 |
| NOC: RECORDED |
| Applicant name: HUGO A CAMACHO |
| Owner: PINTO JOSEPH & GIOVANNA H&W |
|
Address 441 UNION AVENUE BELLEVILLE, NJ 07109 |
| Lot: 0300 |
| Contracted Stated Job Value: ¤280,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
IDEAL HOMES AT PALM COAST, INC.
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO BOX 353639 PALM COAST, FL 32137 |
CBC1250774 (Exp: 08/31/2026) | (386)446-5161 | (386)447-0238 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
THOMAS A REGULA
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
11320 PHILLIPS PKWY DRIVE E JACKSONVILLE, FL 32256 |
CMC1250075 (Exp: 08/31/2026) | 904-278-0339 | 904-278-0366 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
JOANNA S REELEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
2 MARKET PLACE D PALM COAST, FL 32137 |
CCC1327485 (Exp: 08/31/2020) | 386-445-7945 |
BOB BELL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
3200 PARKER DRIVE ST AUGUSTINE, FL 32084 |
LG35711 (Exp: 08/31/2027) | 904-417-6470 | 877-566-4016 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 10/04/2019 | FINAL APPROVED | FWILLIS |
| Note: Outside outlet cover missing front and back. Office room, Fan does not come on with light switch. All other fans have pull on switch, this one does not. Front door has 3/4" gap between door and saddle. Attic light not coming on with switch. | |||
| ROW - FINAL APRON (AFTER POUR) | 10/03/2019 | APPROVED | RGROSS |
| ROW - STORMWATER FINAL | 10/03/2019 | APPROVED | RGROSS |
| Note: Sec 24-156. LEFT SIDE PROPERTY LINE WILL ALLOW WATER FOT FLOW ONTO THE ADJACENT LOT. PROPERTY LINE GRADE MUST DIRECT WATER CONVEYANCE TO THE FRONT SWALE. | |||
| U -UTILITY RESIDENTIAL FINAL | 10/03/2019 | FINAL APPROVED | LFITZGERALD |
| FINAL SURVEY (OFFICE USE ONLY) | 10/03/2019 | APPROVED | RGROSS |
| FINAL SURVEY (OFFICE USE ONLY) | 09/27/2019 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 09/27/2019 | APPROVED | RGROSS |
| FINAL SURVEY (OFFICE USE ONLY) | 09/26/2019 | Disapproved - NO FEE | RGROSS |
| Note: RIGHT SIDE PROPERTY LINE DRAINAGE IS NOT DRAINING TO THE FRONT SWALE AS SHOWN ON THE FINAL SURVEY ELEVATIONS. SEE SURVEY MARK-UP IN ATTACHMENT DOCUMENTS. | |||
| GAS ROUGH | 09/12/2019 | APPROVED | JGIBSON |
| ROW- PRE-APRON (PRE-POUR) | 08/13/2019 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION | |||
| ROW- PAVER RESTRAINTS | 08/02/2019 | APPROVED | RGROSS |
| ROW- PRE-APRON (PRE-POUR) | 08/02/2019 | PARTIALLY APPROVED | RGROSS |
| Note: APPROVED FOR CONCRETE OVER CULVERT AND APRON ONLY. PAVER RESTRAINTS READY. | |||
| ELECTRIC - EARLY POWER | 07/25/2019 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO DELL FPL RELEASED POWER 3:40 | |||
| GRAVITY SEWER TEST | 06/19/2019 | APPROVED | JGIBSON |
| U - SEWER TIE IN | 06/19/2019 | APPROVED | JGIBSON |
| LATH/BRICK/ WATER BARRIER | 06/03/2019 | APPROVED | MWILLIAMS |
| INSULATION | 05/17/2019 | APPROVED | WMILLER |
| ALL ROUGH | 05/13/2019 | APPROVED | MWILLIAMS |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 05/09/2019 | Disapproved -FEE REQUIRED | WMILLER |
| Note: TO MANY DEFICIENT ITEMS, INSPECTION STOPPED, INCOMPLETE LIST, 1. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL (NEED ALL APPROVED DOCUMENTS FOR INSPECTIONS) 2. ALL METAL BOXES SHALL BE GROUNDED R,E 3905.2 AND NEC.314.4 (LOW VOLTAGE CONSOLE) 3. OUTLETS WITHIN 6 feet OF DOORS… NEC 210.52 4. 1 1/4 FROM EDGE, WHERE WIRING IS RUNS ALONG EDGE OF WOOD FBC E3802.1 WIRING SHALL NOT BE LESS THAN 1.25 inches AWAY FROM WOOD MEMBER OR SHALL BE PROTECTED BY A LISTED STEEL PLATE (LOW VOLTAGE ALARMS CHECK ALL) 5. NAIL PLATES ON ELECTRIC FBC E3802.1 (table), AND 3802.3.2 OR NEC 334.15 b. (RESPECTIVELY) protection from physical damage. (LOW VOLTAGE ALARMS CHECK ALL) 6. MISSING SMOKE DETECTOR IN STUDY PER PLANS 7. NOTCHING AND DRILLING STUDS R 602.6(2) INTERIOR NON BEARING WALLS 6th edition NOT MORE THAN 40 percent FOR NOTCHING, (MASTER BATH TOILET ROOM VTR) 8. NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE (SUPPLY MASTER SHOWER BACKSIDE OF STUD) | |||
| ROOF VALLEY & METAL | 05/01/2019 | APPROVED | MWILLIAMS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/26/2019 | APPROVED | MWILLIAMS |
| ELECTRIC-TUG | 03/08/2019 | APPROVED - AS NOTED | RMARTIN |
| Note: CALLED FPL. RELEASE POWER 2:00 | |||
| TIE BEAM / LINTEL | 02/15/2019 | APPROVED | JHINDMAN |
| FOUND SURVEY APPROVED (OFFICE) | 02/14/2019 | APPROVED | RLEE |
| MONOLITHIC SLAB | 01/30/2019 | APPROVED | MWILLIAMS |
| PLUMBING 1ST ROUGH UNDERGROUND | 01/22/2019 | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| PLUM | COMPLETE | 08/13/2019 | 08/20/2019 |
| Note: Released By: MGARRETT | |||
| ZON | COMPLETE | 08/13/2019 | 08/14/2019 |
| Note: Released By: ELENS | |||
| ELEC | COMPLETE | 05/01/2019 | 05/10/2019 |
| Note: Released By: JHINDMAN | |||
| BLD | COMPLETE | 05/01/2019 | 05/10/2019 |
| Note: Released By: JHINDMAN | |||
| BLD | COMPLETE | 03/15/2019 | 03/22/2019 |
| Note: Released By: JHINDMAN | |||
| SW1 | COMPLETE | 02/11/2019 | 02/14/2019 |
| Note: Released By: RLEE Foundation S | |||
| ZON | COMPLETE | 12/11/2018 | 12/11/2018 |
| Note: Released By: AMOBLEY | |||
| SWALE | COMPLETE | 11/29/2018 | 12/11/2018 |
| Note: Released By: TBAKER | |||
| BLD | COMPLETE | 11/28/2018 | 12/05/2018 |
| Note: Released By: RLEE | |||
| ELEC | COMPLETE | 11/28/2018 | 11/30/2018 |
| Note: Released By: DREWIS | |||
| ENGIN1 | COMPLETE | 11/28/2018 | 11/29/2018 |
| Note: Released By: TBAKER | |||
| MECH | COMPLETE | 11/28/2018 | 12/05/2018 |
| Note: Released By: RLEE | |||
| PLUM | COMPLETE | 11/28/2018 | 12/05/2018 |
| Note: Released By: JHINDMAN | |||
| SW1 | COMPLETE | 11/28/2018 | 11/30/2018 |
| Note: Released By: DREWIS | |||
| UD1 | COMPLETE | 11/28/2018 | 12/03/2018 |
| Note: Released By: MBACON | |||
| ZON | HOLD | 11/28/2018 | 11/29/2018 |
| Note: Held By: AMOBLEY Site,landscape and floor plans do not match Floor plan shows a walkway seperating the driveway from the entry. Layout on all must match |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 10/08/2019 |
| NEW RESIDENTIAL INSPECTIONS | ¤592.00 | 12/17/2018 |
| SITE PLAN 20 | ¤20.00 | 12/17/2018 |
| SURCHARGE FS 533.721 | ¤14.63 | 12/17/2018 |
| SURCHARGE - FS 468.631 | ¤21.95 | 12/17/2018 |
| STORM WATER PERMIT FEES | ¤80.00 | 12/17/2018 |
| 3% TRANS IMPACT FEE CREDIT | (¤48.96) | 12/17/2018 |
| ADMIN FEE | ¤20.00 | 12/17/2018 |
| ELECTRIC FEE | ¤237.60 | 12/17/2018 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.70) | 12/17/2018 |
| IMPACT FEE FIRE | ¤223.38 | 12/17/2018 |
| IMPACT FEE PARKS | ¤849.24 | 12/17/2018 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 12/17/2018 |
| RECORDING FEE REIMBURSE DOC | ¤52.50 | 12/17/2018 |
| IMPACT FEE TRANSPORTATION | ¤1,632.00 | 12/17/2018 |
| MECHANICAL FEE | ¤237.60 | 12/17/2018 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 12/17/2018 |
| PLAN CHECK FEE | ¤118.40 | 12/17/2018 |
| PLUMBING FEE | ¤237.60 | 12/17/2018 |