I want to search for...

Permit #2018110877

Permit Details

Status: COED

Parcel Id: 07-11-31-7009-00170-0300
CONDITIONED SPACE: 2351 sqft
GARAGE: 483 sqft
OPENED PORCH (WITH ROOF) : 88 sqft
OPENED PORCH (WITH ROOF) : 290 sqft
Total Square Footage: 3212 sqft
Block: 00170
Subdivision: 2208 - SECTION 9-FLORIDA PARK
Job Phone: (386)446-5161
Location Address: 11 FAIRBANK LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/17/2018
NOC: RECORDED
Applicant name: HUGO A CAMACHO
Owner: PINTO JOSEPH & GIOVANNA H&W

Address

441 UNION AVENUE

BELLEVILLE, NJ 07109

Lot: 0300
Contracted Stated Job Value: ¤280,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

IDEAL HOMES AT PALM COAST, INC.
Status Location Address State License Number Phone Fax
INACTIVE

PO BOX 353639

PALM COAST, FL 32137

CBC1250774 (Exp: 08/31/2026) (386)446-5161 (386)447-0238

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
THOMAS A REGULA
Status Location Address State License Number Phone Fax
INACTIVE

11320 PHILLIPS PKWY DRIVE E

JACKSONVILLE, FL 32256

CMC1250075 (Exp: 08/31/2026) 904-278-0339 904-278-0366
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
JOANNA S REELEY
Status Location Address State License Number Phone
INACTIVE

2 MARKET PLACE D

PALM COAST, FL 32137

CCC1327485 (Exp: 08/31/2020) 386-445-7945
BOB BELL
Status Location Address State License Number Phone Fax
ACTIVE

3200 PARKER DRIVE

ST AUGUSTINE, FL 32084

LG35711 (Exp: 08/31/2027) 904-417-6470 877-566-4016

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 10/04/2019 FINAL APPROVED FWILLIS
Note: Outside outlet cover missing front and back. Office room, Fan does not come on with light switch. All other fans have pull on switch, this one does not. Front door has 3/4" gap between door and saddle. Attic light not coming on with switch.
ROW - FINAL APRON (AFTER POUR) 10/03/2019 APPROVED RGROSS
ROW - STORMWATER FINAL 10/03/2019 APPROVED RGROSS
Note: Sec 24-156. LEFT SIDE PROPERTY LINE WILL ALLOW WATER FOT FLOW ONTO THE ADJACENT LOT. PROPERTY LINE GRADE MUST DIRECT WATER CONVEYANCE TO THE FRONT SWALE.
U -UTILITY RESIDENTIAL FINAL 10/03/2019 FINAL APPROVED LFITZGERALD
FINAL SURVEY (OFFICE USE ONLY) 10/03/2019 APPROVED RGROSS
FINAL SURVEY (OFFICE USE ONLY) 09/27/2019 APPROVED RGROSS
Note: THIS IS A REINSPECTION
ROW FIELD SURVEY /GRADING CERTIFICATION 09/27/2019 APPROVED RGROSS
FINAL SURVEY (OFFICE USE ONLY) 09/26/2019 Disapproved - NO FEE RGROSS
Note: RIGHT SIDE PROPERTY LINE DRAINAGE IS NOT DRAINING TO THE FRONT SWALE AS SHOWN ON THE FINAL SURVEY ELEVATIONS. SEE SURVEY MARK-UP IN ATTACHMENT DOCUMENTS.
GAS ROUGH 09/12/2019 APPROVED JGIBSON
ROW- PRE-APRON (PRE-POUR) 08/13/2019 APPROVED RGROSS
Note: THIS IS A REINSPECTION
ROW- PAVER RESTRAINTS 08/02/2019 APPROVED RGROSS
ROW- PRE-APRON (PRE-POUR) 08/02/2019 PARTIALLY APPROVED RGROSS
Note: APPROVED FOR CONCRETE OVER CULVERT AND APRON ONLY. PAVER RESTRAINTS READY.
ELECTRIC - EARLY POWER 07/25/2019 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED POWER 3:40
GRAVITY SEWER TEST 06/19/2019 APPROVED JGIBSON
U - SEWER TIE IN 06/19/2019 APPROVED JGIBSON
LATH/BRICK/ WATER BARRIER 06/03/2019 APPROVED MWILLIAMS
INSULATION 05/17/2019 APPROVED WMILLER
ALL ROUGH 05/13/2019 APPROVED MWILLIAMS
Note: THIS IS A REINSPECTION
ALL ROUGH 05/09/2019 Disapproved -FEE REQUIRED WMILLER
Note: TO MANY DEFICIENT ITEMS, INSPECTION STOPPED, INCOMPLETE LIST, 1. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL (NEED ALL APPROVED DOCUMENTS FOR INSPECTIONS) 2. ALL METAL BOXES SHALL BE GROUNDED R,E 3905.2 AND NEC.314.4 (LOW VOLTAGE CONSOLE) 3. OUTLETS WITHIN 6 feet OF DOORS… NEC 210.52 4. 1 1/4 FROM EDGE, WHERE WIRING IS RUNS ALONG EDGE OF WOOD FBC E3802.1 WIRING SHALL NOT BE LESS THAN 1.25 inches AWAY FROM WOOD MEMBER OR SHALL BE PROTECTED BY A LISTED STEEL PLATE (LOW VOLTAGE ALARMS CHECK ALL) 5. NAIL PLATES ON ELECTRIC FBC E3802.1 (table), AND 3802.3.2 OR NEC 334.15 b. (RESPECTIVELY) protection from physical damage. (LOW VOLTAGE ALARMS CHECK ALL) 6. MISSING SMOKE DETECTOR IN STUDY PER PLANS 7. NOTCHING AND DRILLING STUDS R 602.6(2) INTERIOR NON BEARING WALLS 6th edition NOT MORE THAN 40 percent FOR NOTCHING, (MASTER BATH TOILET ROOM VTR) 8. NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE (SUPPLY MASTER SHOWER BACKSIDE OF STUD)
ROOF VALLEY & METAL 05/01/2019 APPROVED MWILLIAMS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/26/2019 APPROVED MWILLIAMS
ELECTRIC-TUG 03/08/2019 APPROVED - AS NOTED RMARTIN
Note: CALLED FPL. RELEASE POWER 2:00
TIE BEAM / LINTEL 02/15/2019 APPROVED JHINDMAN
FOUND SURVEY APPROVED (OFFICE) 02/14/2019 APPROVED RLEE
MONOLITHIC SLAB 01/30/2019 APPROVED MWILLIAMS
PLUMBING 1ST ROUGH UNDERGROUND 01/22/2019 APPROVED JGIBSON

Review History

Department Status Date In Date Out
PLUM COMPLETE 08/13/2019 08/20/2019
Note: Released By: MGARRETT
ZON COMPLETE 08/13/2019 08/14/2019
Note: Released By: ELENS
ELEC COMPLETE 05/01/2019 05/10/2019
Note: Released By: JHINDMAN
BLD COMPLETE 05/01/2019 05/10/2019
Note: Released By: JHINDMAN
BLD COMPLETE 03/15/2019 03/22/2019
Note: Released By: JHINDMAN
SW1 COMPLETE 02/11/2019 02/14/2019
Note: Released By: RLEE Foundation S
ZON COMPLETE 12/11/2018 12/11/2018
Note: Released By: AMOBLEY
SWALE COMPLETE 11/29/2018 12/11/2018
Note: Released By: TBAKER
BLD COMPLETE 11/28/2018 12/05/2018
Note: Released By: RLEE
ELEC COMPLETE 11/28/2018 11/30/2018
Note: Released By: DREWIS
ENGIN1 COMPLETE 11/28/2018 11/29/2018
Note: Released By: TBAKER
MECH COMPLETE 11/28/2018 12/05/2018
Note: Released By: RLEE
PLUM COMPLETE 11/28/2018 12/05/2018
Note: Released By: JHINDMAN
SW1 COMPLETE 11/28/2018 11/30/2018
Note: Released By: DREWIS
UD1 COMPLETE 11/28/2018 12/03/2018
Note: Released By: MBACON
ZON HOLD 11/28/2018 11/29/2018
Note: Held By: AMOBLEY Site,landscape and floor plans do not match Floor plan shows a walkway seperating the driveway from the entry. Layout on all must match

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 10/08/2019
NEW RESIDENTIAL INSPECTIONS ¤592.00 12/17/2018
SITE PLAN 20 ¤20.00 12/17/2018
SURCHARGE FS 533.721 ¤14.63 12/17/2018
SURCHARGE - FS 468.631 ¤21.95 12/17/2018
STORM WATER PERMIT FEES ¤80.00 12/17/2018
3% TRANS IMPACT FEE CREDIT (¤48.96) 12/17/2018
ADMIN FEE ¤20.00 12/17/2018
ELECTRIC FEE ¤237.60 12/17/2018
3% FIRE IMPACT FEE CREDIT (¤6.70) 12/17/2018
IMPACT FEE FIRE ¤223.38 12/17/2018
IMPACT FEE PARKS ¤849.24 12/17/2018
IMPACT FEE SCHOOL ¤3,600.00 12/17/2018
RECORDING FEE REIMBURSE DOC ¤52.50 12/17/2018
IMPACT FEE TRANSPORTATION ¤1,632.00 12/17/2018
MECHANICAL FEE ¤237.60 12/17/2018
3% PARKS IMPACT FEE CREDIT (¤25.48) 12/17/2018
PLAN CHECK FEE ¤118.40 12/17/2018
PLUMBING FEE ¤237.60 12/17/2018
Fees Total Due: ¤0.00 Total Paid: ¤7,895.76