I want to search for...

Permit #2018120161

Permit Details

Status: COED

Parcel Id: 07-11-31-7029-00530-0140
CONDITIONED SPACE: 1571 sqft
OPENED PORCH (WITH ROOF) : 201 sqft
OPENED PORCH (WITH ROOF) : 46 sqft
GARAGE: 443 sqft
Total Square Footage: 2261 sqft
Block: 00530
Subdivision: 2209 - SECTION 29-ROYAL PALMS
Job Phone: 407-307-4753
Location Address: 4 RYKER LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/25/2019
NOC: RECORDED
Applicant name: SHAWN VIRAG
Owner: BRITE PROPERTIES OF FLORIDA LLC

Address

7345 GREENBRIAR PKWY

ORLANDO, FL 32819

Lot: 0140
Contracted Stated Job Value: ¤135,466.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

SHAWNTELLE CONSULTING AND DESIGN LLC
Status Location Address State License Number Phone
CANCEL

611 LARGOVISTA DR

OAKLAND, FL 34787

CBC1261160 (Exp: 08/31/2020) 407-307-4753

Sub Contractors

TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
JOSEPH H STRADA JR
Status Location Address State License Number Phone
CANCEL

3400 ST JOHNS PKWY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2022) 877-906-1113
ROBERT G DELLO RUSSO
Status Location Address State License Number Phone Fax
DECEASED

531 CODISCO WAY

SANFORD, FL 32771

CAC032448 (Exp: 08/31/2022) (407)831-2665 (407)333-3853
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996

Inspection History

Type Request Date Result Inspector
ROW - STORMWATER FINAL 08/09/2019 FINAL APPROVED KHOWELL
ROW - FINAL INSPECTION 08/09/2019 APPROVED KHOWELL
U -UTILITY RESIDENTIAL FINAL 07/03/2019 FINAL APPROVED MBACON
ROW - FINAL INSPECTION 07/03/2019 APPROVED RGROSS
BLD - BUILDING FINAL 07/03/2019 FINAL APPROVED DROCKWELL
ROW - FINAL APRON (AFTER POUR) 07/03/2019 APPROVED RGROSS
ROW FIELD SURVEY /GRADING CERTIFICATION 07/02/2019 APPROVED KHOWELL
FINAL SURVEY (OFFICE USE ONLY) 07/02/2019 APPROVED KHOWELL
Note: THIS IS A REINSPECTION
FINAL SURVEY (OFFICE USE ONLY) 06/27/2019 Disapproved - NO FEE KHOWELL
Note: SEE NOTES ON SURVEY
ELECTRIC - EARLY POWER 05/30/2019 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED POWER 3:40
ROW- PRE-APRON (PRE-POUR) 05/30/2019 APPROVED - AS NOTED KHOWELL
Note: THIS IS A REINSPECTION It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist READY TO POUR upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete.
ROW- PRE-APRON (PRE-POUR) 05/28/2019 Disapproved - NO FEE KHOWELL
Note: THIS IS A REINSPECTION CULVERT PIPE NOT CENTERED IN DRIVEWAY
ROW- PRE-APRON (PRE-POUR) 05/24/2019 CANCELLED BY APPLICANT KHOWELL
U - SEWER TIE IN 05/13/2019 APPROVED JGIBSON
GRAVITY SEWER TEST 05/13/2019 APPROVED JGIBSON
LATH/BRICK/ WATER BARRIER 04/17/2019 APPROVED DROCKWELL
INSULATION 04/17/2019 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
INSULATION 04/15/2019 Disapproved - NO FEE DROCKWELL
Note: THIS IS A REINSPECTION/ Repair damage
INSULATION 04/12/2019 CANCELLED BY APPLICANT DROCKWELL
ALL ROUGH 04/09/2019 APPROVED MWILLIAMS
ROOF VALLEY & METAL 04/01/2019 APPROVED MWILLIAMS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/28/2019 APPROVED - AS NOTED MWILLIAMS
Note: Header detail for load bearing wall calls for angled strapping on both ends of the header please add the strapping or submit a revision to refleft method of strapping currently being used. Will recheck at all rough inspection
TIE BEAM / LINTEL 03/15/2019 APPROVED DROCKWELL
ELECTRIC-TUG 03/15/2019 APPROVED DROCKWELL
FOUND SURVEY APPROVED (OFFICE) 03/14/2019 APPROVED RLEE
MONOLITHIC SLAB 03/06/2019 APPROVED WMILLER
Note: THIS IS A REINSPECTION DEFICIENCIES NOTED PRIOR BY INSPECTOR JC AND DR RESOLVED
MONOLITHIC SLAB 03/05/2019 Disapproved -FEE REQUIRED DROCKWELL
Note: THIS IS A REINSPECTION/ UFER ground ans adjoining steel laying on the ground.Install new chairs and lift for proper clearance/UFER must be tied to steel/ Dowel also on ground...install in proper place and tie off to footing steel.
MONOLITHIC SLAB 03/04/2019 Disapproved -FEE REQUIRED JCOLASANTI
Note: UFER CONNECTION NEEDS TO BE ACCESSABLE with 20' rebar length NEC 250.68(A)
PLUMBING 1ST ROUGH UNDERGROUND 02/26/2019 APPROVED JGIBSON

Review History

Department Status Date In Date Out
BLD COMPLETE 03/11/2019 03/14/2019
Note: Released By: RLEE
SW1 COMPLETE 03/07/2019 03/14/2019
Note: Released By: JHINDMAN foundation
ELEC COMPLETE 01/14/2019 01/22/2019
Note: Released By: JHINDMAN
PLUM COMPLETE 01/14/2019 01/22/2019
Note: Released By: JHINDMAN
ZON COMPLETE 01/03/2019 01/03/2019
Note: Released By: AMOBLEY
SWALE COMPLETE 01/02/2019 01/15/2019
Note: Released By: TBAKER
ZON HOLD 12/26/2018 12/27/2018
Note: Held By: AMOBLEY Need additional shrubs on left side
ENGIN1 COMPLETE 12/26/2018 01/02/2019
Note: Released By: TBAKER
SW1 COMPLETE 12/26/2018 01/04/2019
Note: Released By: JHINDMAN
ELEC HOLD 12/26/2018 01/04/2019
Note: Held By: JHINDMAN Per NEC 2014 210.52 Provide receptacles for both left side bedrooms at the switch wall. 2nd request
UD1 COMPLETE 12/26/2018 01/03/2019
Note: Released By: MBACON
PLUM HOLD 12/26/2018 01/04/2019
Note: Held By: JHINDMAN 1. Provide a minimum 3" drain to master bath water closet per 6th ed. FBC R Table 3005.4.1. J. hindman 986-3784. 2nd request
BLD COMPLETE 12/06/2018 12/12/2018
Note: Released By: JHINDMAN
ELEC HOLD 12/06/2018 12/10/2018
Note: Held By: DREWIS Per NEC 2014 210.52 Provide receptacles for both left side bedrooms at the switch wall. Additional GFCI in the laundry area. GFCI with weather proof cover(406.9) on the porch. Daniel Rewis 986-4736
ENGIN1 HOLD 12/06/2018 12/10/2018
Note: Held By: TBAKER No benchmark on survey
MECH COMPLETE 12/06/2018 12/12/2018
Note: Released By: JHINDMAN
PLUM HOLD 12/06/2018 12/12/2018
Note: Held By: JHINDMAN 1. Provide a minimum 3" drain to master bath water closet per 6th ed. FBC R Table 3005.4.1. J. hindman 986-3784.
SW1 HOLD 12/06/2018 12/10/2018
Note: Held By: DREWIS Provide a site plan depicting storm water flow elevations and grade at and away from the foundation wall of residence per Residential Florida Building Code R401.3 and City of Palm Coast Tech. Manual Sec. 5 Eng. Standard 300. Daniel Rewis 986-4736
UD1 HOLD 12/06/2018 12/12/2018
Note: Held By: MBACON PEP Panel not shown on electrical plans PEP Panel is not shown in the electrical plan. Submit a new electrical plan showing PEP Panel on the building on the same side of the building as indicated in the Utility marked site plan. Please remove septic and drainfield from survey.
ZON HOLD 12/06/2018 12/06/2018
Note: Held By: AMOBLEY Survey should have total lot square footage Need additional shrubs on left side

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤40.00 08/13/2019
REINSPECTION FEE ¤40.00 08/13/2019
REINSPECTION FEE ¤40.00 08/13/2019
NEW RESIDENTIAL INSPECTIONS ¤406.00 01/25/2019
SITE PLAN 20 ¤20.00 01/25/2019
SURCHARGE FS 533.721 ¤10.73 01/25/2019
SURCHARGE - FS 468.631 ¤16.09 01/25/2019
STORM WATER PERMIT FEES ¤80.00 01/25/2019
3% TRANS IMPACT FEE CREDIT (¤48.96) 01/25/2019
ELECTRIC FEE ¤181.80 01/25/2019
3% FIRE IMPACT FEE CREDIT (¤6.70) 01/25/2019
IMPACT FEE FIRE ¤223.38 01/25/2019
IMPACT FEE PARKS ¤849.24 01/25/2019
IMPACT FEE SCHOOL ¤3,600.00 01/25/2019
IMPACT FEE TRANSPORTATION ¤1,632.00 01/25/2019
MECHANICAL FEE ¤181.80 01/25/2019
3% PARKS IMPACT FEE CREDIT (¤25.48) 01/25/2019
PLAN CHECK FEE ¤81.20 01/25/2019
PLUMBING FEE ¤181.80 01/25/2019
ADMIN FEE ¤20.00 01/25/2019
Fees Total Due: ¤0.00 Total Paid: ¤7,522.90