Permit #2018120164
Permit Details
Status: COED
| Parcel Id: 07-11-31-7025-00330-0170 |
| CONDITIONED SPACE: 1390 sqft |
| GARAGE: 445 sqft |
| OPENED PORCH (WITH ROOF) : 120 sqft |
| OPENED PORCH (WITH ROOF) : 52 sqft |
| Total Square Footage: 2007 sqft |
| Block: 00330 |
| Subdivision: 2189 - SECTION 25-PINE GROVE |
| Job Phone: 407-307-4753 |
| Location Address: 5 PEPPER LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/19/2019 |
| NOC: RECORDED |
| Applicant name: SHAWN VIRAG |
| Owner: BRITE PROPERTIES OF FLORIDA LLC |
|
Address 7345 GREENBRIAR PKWY ORLANDO, FL 32819 |
| Lot: 0170 |
| Contracted Stated Job Value: ¤127,800.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SHAWNTELLE CONSULTING AND DESIGN LLC
| Status | Location Address | State License Number | Phone |
| CANCEL |
611 LARGOVISTA DR OAKLAND, FL 34787 |
CBC1261160 (Exp: 08/31/2020) | 407-307-4753 |
Sub Contractors
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| CANCEL |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2022) | 877-906-1113 |
ROBERT G DELLO RUSSO
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
531 CODISCO WAY SANFORD, FL 32771 |
CAC032448 (Exp: 08/31/2022) | (407)831-2665 | (407)333-3853 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 10/31/2019 | APPROVED | JDELBONIS |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 10/30/2019 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: doors locked need access to complete inspection | |||
| ROW - FINAL APRON (AFTER POUR) | 10/30/2019 | APPROVED - AS NOTED | MMAJEWSKI |
| Note: CLEAN CONCRETE OUT OF ENDS OF CULVERT PIPE | |||
| ROW - STORMWATER FINAL | 10/30/2019 | APPROVED | MMAJEWSKI |
| U -UTILITY RESIDENTIAL FINAL | 10/30/2019 | FINAL APPROVED | LFITZGERALD |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/22/2019 | APPROVED | MMAJEWSKI |
| FINAL SURVEY (OFFICE USE ONLY) | 10/22/2019 | APPROVED | MMAJEWSKI |
| FINAL SURVEY (OFFICE USE ONLY) | 10/03/2019 | Disapproved - NO FEE | KHOWELL |
| Note: SEE SURVEY MARK UP | |||
| ROW- PRE-APRON (PRE-POUR) | 08/21/2019 | APPROVED - AS NOTED | KHOWELL |
| Note: THIS IS A REINSPECTION It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist READY TO POUR upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete. | |||
| ELECTRIC - EARLY POWER | 08/20/2019 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO DELL FPL RELEASED POWER 3:30 | |||
| ELECTRIC - EARLY POWER | 08/19/2019 | Disapproved -FEE REQUIRED | RMARTIN |
| Note: ALL DOORS LOCKED NEED ACCESS FOR INSPECTION | |||
| ELECTRIC-TUG | 08/02/2019 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO DELL FPL RELEASED POWER 2:45 | |||
| ELECTRIC-TUG | 08/01/2019 | Disapproved -FEE REQUIRED | JDELBONIS |
| Note: THIS IS A REINSPECTION riser diagram calls for 200 amp main braker and panel and a 150 amp main braker was installed | |||
| ROW- PRE-APRON (PRE-POUR) | 07/26/2019 | Disapproved -FEE REQUIRED | KHOWELL |
| Note: THIS IS A REINSPECTION CULVERT PIPE IS OUT OF TOLERANCE SLOPED MORE THEN THE 0.1' MAXIMUM ACROSS THE CULVERT, 5" MIN. THICK CONCRETE REQUIRED IN THE ROW AND 4" MIN. THICK CONCRETE REQUIRED ABOVE THE ROW. REMOVE ORGANIC MATERIAL / ROOTS FROM THE PAD AREA. DIG THE LEFT CULVERT FOOTER OUT PER THE CITY STANDARD DRIVEWAY DETAIL | |||
| ROW- PRE-APRON (PRE-POUR) | 07/10/2019 | Disapproved -FEE REQUIRED | KHOWELL |
| Note: THIS IS A REINSPECTION CULVERT PIPE IS OUT OF TOLERANCE, THE ROAD FORM NEEDS TO MATCH THE CURVE OF THE ROADWAY. 5" MIN. THICK CONCRETE REQUIRED IN THE ROW AND 4" MIN. THICK CONCRETE REQUIRED ABOVE THE ROW. REMOVE ORGANIC MATERIAL / ROOTS FROM THE PAD AREA | |||
| ROW- PRE-APRON (PRE-POUR) | 07/08/2019 | CANCELLED BY APPLICANT | RGROSS |
| Note: THIS IS A REINSPECTION | |||
| ROW - DRAINAGE | 06/28/2019 | APPROVED - AS NOTED | KHOWELL |
| Note: THIS IS A REINSPECTION GRADING CONTRACTOR ON SITE AND WILL OPEN UP SWALE BEFORE HE LEAVES TODAY | |||
| ROW - DRAINAGE | 06/24/2019 | Disapproved - NO FEE | KHOWELL |
| Note: REMOVE THE DIRT FROM THE SWALE AREA AND RESTORE DRAINAGE CONVEYANCE IN THE SWALE THIS WILL BE REINSPECTED ON 6-28-19 IF IT HAS NOT BEEN OPENED A REISPECTION FEE WILL BE ADDED | |||
| ROW- PRE-APRON (PRE-POUR) | 06/24/2019 | Disapproved -FEE REQUIRED | KHOWELL |
| Note: NOT READY FOR INSPECTION, NO CULVERT PIPE SET | |||
| LATH/BRICK/ WATER BARRIER | 06/19/2019 | APPROVED | FWILLIS |
| GRAVITY SEWER TEST | 05/29/2019 | APPROVED | JGIBSON |
| U - SEWER TIE IN | 05/29/2019 | APPROVED | JGIBSON |
| ROOF VALLEY & METAL | 05/28/2019 | APPROVED | MWILLIAMS |
| INSULATION | 05/28/2019 | APPROVED | MWILLIAMS |
| ELECTRIC-TUG | 05/28/2019 | Disapproved -FEE REQUIRED | RMARTIN |
| Note: STILL NO ELECTRIC PLAN ON SITE, NEED TO HAVE ELECTRIC PLAN ON SITE TO CHECK RISER DIAGRAM AND MAIN BREAKER SIZE, plan on site does not have electric | |||
| ALL ROUGH | 05/23/2019 | APPROVED - AS NOTED | JCOLASANTI |
| Note: THIS IS A REINSPECTION need to repair main conduit into meter can that is tight along block, need to repair little rips into conduit....need to mount fresh air duct at outside ceiling | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/23/2019 | APPROVED - AS NOTED | JCOLASANTI |
| Note: tighten tap cons on straps into block front and rear bedrooms FBC 802 | |||
| ELECTRIC-TUG | 05/16/2019 | Disapproved -FEE REQUIRED | RMARTIN |
| Note: STILL NO ELECTRIC PLAN ON SITE, NEED TO HAVE ELECTRIC PLAN ON SITE TO CHECK RISER DIAGRAM AND MAIN BREAKER SIZE | |||
| ALL ROUGH | 04/29/2019 | Disapproved - NO FEE | JCOLASANTI |
| Note: not ready for all rough inspection, need roof sheathing inspection complete before all rough | |||
| ELECTRIC-TUG | 04/24/2019 | Disapproved -FEE REQUIRED | RMARTIN |
| Note: NEED TO HAVE ELECTRIC PLAN ON SITE TO CHECK RISER DIAGRAM AND MAIN BREAKER SIZE | |||
| TIE BEAM / LINTEL | 04/22/2019 | APPROVED | JCOLASANTI |
| FOUND SURVEY APPROVED (OFFICE) | 04/18/2019 | APPROVED | RLEE |
| MONOLITHIC SLAB | 04/11/2019 | APPROVED | JCOLASANTI |
| PLUMBING 1ST ROUGH UNDERGROUND | 04/08/2019 | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 04/12/2019 | 04/18/2019 |
| Note: Released By: RLEE final | |||
| SW1 | COMPLETE | 02/05/2019 | 02/05/2019 |
| Note: Released By: RLEE | |||
| ZON | COMPLETE | 02/05/2019 | 02/06/2019 |
| Note: Released By: AMOBLEY | |||
| SWALE | COMPLETE | 01/17/2019 | 02/05/2019 |
| Note: Released By: TBAKER | |||
| ZON | HOLD | 01/14/2019 | 01/14/2019 |
| Note: Held By: AMOBLEY Rear setback must be from furthest point of structure to property line Need landscape plan of correct property | |||
| ENGIN1 | COMPLETE | 01/14/2019 | 01/17/2019 |
| Note: Released By: TBAKER | |||
| SW1 | HOLD | 01/14/2019 | 01/22/2019 |
| Note: Held By: JHINDMAN 1. Provide positive flow to the front. The rear yard cannot drain onto adjacent properties. Palm Coast Tech manual ch5 300. | |||
| ELEC | COMPLETE | 01/14/2019 | 01/22/2019 |
| Note: Released By: JHINDMAN | |||
| UD1 | COMPLETE | 01/14/2019 | 01/17/2019 |
| Note: Released By: LFITZGERALD Gravity Sewer new homes This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. The NFPA Clear Zone distance there can be no obstacles in front of the Hydrant and 7.5’ on the sides or 4’ behind | |||
| BLD | COMPLETE | 12/06/2018 | 12/12/2018 |
| Note: Released By: JHINDMAN | |||
| ELEC | HOLD | 12/06/2018 | 12/10/2018 |
| Note: Held By: DREWIS Per NEC 2014 210.52F, Additional GFCI needed in the laundry area. Daniel Rewis 986-4736 | |||
| ENGIN1 | HOLD | 12/06/2018 | 12/10/2018 |
| Note: Held By: TBAKER No survey on benchmark | |||
| MECH | COMPLETE | 12/06/2018 | 12/12/2018 |
| Note: Released By: JHINDMAN | |||
| PLUM | COMPLETE | 12/06/2018 | 12/12/2018 |
| Note: Released By: JHINDMAN | |||
| SW1 | HOLD | 12/06/2018 | 12/10/2018 |
| Note: Held By: DREWIS Provide a site plan depicting storm water flow elevations and grade at and away from the foundation wall of residence per Residential Florida Building Code R401.3 and City of Palm Coast Tech. Manual Sec. 5 Eng. Standard 300. Daniel Rewis 986-4736 | |||
| UD1 | HOLD | 12/06/2018 | 12/12/2018 |
| Note: Held By: MBACON Please remove Septic and drainfield from survey. | |||
| ZON | HOLD | 12/06/2018 | 12/07/2018 |
| Note: Held By: AMOBLEY Can not finish review. Survey is for a different property. 5 Pepper Lane is not a corner lot Please submit correct survey Survey must have total lot square footage and have setbacks from house to all adjacent properties. Front, rear and sides |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 11/08/2019 |
| REINSPECTION FEE | ¤40.00 | 11/08/2019 |
| REINSPECTION FEE | ¤40.00 | 11/08/2019 |
| REINSPECTION FEE | ¤40.00 | 08/13/2019 |
| REINSPECTION FEE | ¤40.00 | 08/13/2019 |
| REINSPECTION FEE | ¤40.00 | 08/13/2019 |
| REINSPECTION FEE | ¤40.00 | 08/13/2019 |
| REINSPECTION FEE | ¤40.00 | 08/13/2019 |
| REINSPECTION FEE | ¤40.00 | 08/13/2019 |
| REINSPECTION FEE | ¤40.00 | 08/13/2019 |
| ADMIN FEE | ¤20.00 | 02/19/2019 |
| NEW RESIDENTIAL INSPECTIONS | ¤360.00 | 02/19/2019 |
| SITE PLAN 20 | ¤20.00 | 02/19/2019 |
| SURCHARGE FS 533.721 | ¤9.76 | 02/19/2019 |
| SURCHARGE - FS 468.631 | ¤14.64 | 02/19/2019 |
| STORM WATER PERMIT FEES | ¤80.00 | 02/19/2019 |
| 3% TRANS IMPACT FEE CREDIT | (¤48.96) | 02/19/2019 |
| ELECTRIC FEE | ¤168.00 | 02/19/2019 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.70) | 02/19/2019 |
| IMPACT FEE FIRE | ¤223.38 | 02/19/2019 |
| IMPACT FEE PARKS | ¤849.24 | 02/19/2019 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 02/19/2019 |
| IMPACT FEE TRANSPORTATION | ¤1,632.00 | 02/19/2019 |
| MECHANICAL FEE | ¤168.00 | 02/19/2019 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 02/19/2019 |
| PLAN CHECK FEE | ¤72.00 | 02/19/2019 |
| PLUMBING FEE | ¤168.00 | 02/19/2019 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤7,703.88 |