Permit #2018120397

Permit Details

Status: COED

Parcel Id: 07-11-31-7032-00650-0130
CONDITIONED SPACE: 1806 sqft
GARAGE: 453 sqft
OPENED PORCH (WITH ROOF) : 60 sqft
SCREEN PORCH (SOLID ROOF) : 240 sqft
Total Square Footage: 2559 sqft
Block: 00650
Subdivision: 2155 - SECTION 32-ROYAL PALMS
Job Phone: 386-960-7720
Location Address: 13 ROLLING SANDS DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/11/2019
NOC: RECORDED
Applicant name: LAWRENCE FRED SIETSMA
Owner: AVTEC HOMES INC

Address

620 MALABAR ROAD SE STE 5

PALM BAY, FL 32907

Lot: 0130
Contracted Stated Job Value: ¤225,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

AVTEC HOMES INC
Status Location Address State License Number Phone
CANCEL

2405 E GRAVES AVE

ORANGE CITY, FL 32763

CRC041905 (Exp: 08/31/2024) 386-960-7720

Sub Contractors

DOUGLAS EDWARD RICHARDS
Status Location Address State License Number Phone Fax
INACTIVE

108 E INDIANA AVENUE

DELAND, FL 32724

CCC1328824 (Exp: 08/31/2024) 386-736-4226 386-740-0535
STEVEN JAY SMITH
Status Location Address State License Number Phone
INACTIVE

104 West Cedar Avenue

Orange City, FL 32763

EC0001542 (Exp: 08/31/2022) (386)775-7776
RUSSELL J CARTER
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 302

DELAND, FL 32721

CFC1425938 (Exp: 08/31/2026) 386-736-4220 386-736-4219
BRUCE R BOLTON
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

1982 SR 44

NEW SMYRNA BEACH, FL 32168

SUITE 357

NEW SMYRNA BEACH, FL 32168

CAC1817407 (Exp: 08/31/2022) 386-216-5975 386-402-4191

Inspection History

Type Request Date Result Inspector
ROW - STORMWATER FINAL 06/26/2019 FINAL APPROVED KHOWELL
Note: THIS IS A REINSPECTION
U -UTILITY RESIDENTIAL FINAL 06/26/2019 FINAL APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION
U -UTILITY RESIDENTIAL FINAL 06/25/2019 Disapproved -FEE REQUIRED LFITZGERALD
Note: the sewer clean out cap is required to be flush with final sod grade. Please cut lower accordingly.
ROW - FINAL APRON (AFTER POUR) 06/25/2019 APPROVED KHOWELL
ROW - STORMWATER FINAL 06/25/2019 Disapproved -FEE REQUIRED KHOWELL
Note: SOD THE BARE AREAS ON THE LEFT SIDE IN THE R.O.W. WITH BAHIA SOD
BLD - BUILDING FINAL 06/25/2019 FINAL APPROVED DROCKWELL
FINAL SURVEY (OFFICE USE ONLY) 06/21/2019 APPROVED KHOWELL
ROW FIELD SURVEY /GRADING CERTIFICATION 06/21/2019 APPROVED KHOWELL
ELECTRIC - EARLY POWER 06/12/2019 APPROVED MWILLIAMS
ROW- PRE-APRON (PRE-POUR) 06/05/2019 APPROVED - AS NOTED KHOWELL
Note: THIS IS A REINSPECTION It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist READY TO POUR upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete.
ROW- PRE-APRON (PRE-POUR) 06/03/2019 Disapproved -FEE REQUIRED KHOWELL
Note: THIS IS A REINSPECTION THE CULVERT PIPE IS NOT 8' FROM THE EXISTING EDGE OF PAVEMENT
ROW- PRE-APRON (PRE-POUR) 05/31/2019 CANCELLED BY APPLICANT KHOWELL
Note: THIS IS A REINSPECTION BRIAN TEXTED AND CANCELLED INSPECTION
ROW- PRE-APRON (PRE-POUR) 05/30/2019 CANCELLED BY APPLICANT KHOWELL
Note: BRIAN TEXTED AND CANCELLED
LATH/BRICK/ WATER BARRIER 04/29/2019 APPROVED MWILLIAMS
INSULATION 04/24/2019 APPROVED MWILLIAMS
Note: THIS IS A REINSPECTION
INSULATION 04/23/2019 Disapproved -FEE REQUIRED MWILLIAMS
Note: Multiple penetrations through the top plate not fire caulked. plumbing and electrical wires and pipes.
ALL ROUGH 04/18/2019 APPROVED - AS NOTED JCOLASANTI
Note: need to hold water in the waste test pipe....need to fireblock kitchen exhaust fbc 302
ROOF VALLEY & METAL 04/15/2019 APPROVED DROCKWELL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/10/2019 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/09/2019 Disapproved -FEE REQUIRED DROCKWELL
Note: Not ready for inspection/Anchor entry headers to lintel/Nail off sheathing.
TIE BEAM / LINTEL 03/28/2019 APPROVED DROCKWELL
FOUND SURVEY APPROVED (OFFICE) 03/27/2019 APPROVED JHINDMAN
MONOLITHIC SLAB 03/14/2019 APPROVED DROCKWELL
PLUMBING 1ST ROUGH UNDERGROUND 03/12/2019 APPROVED JGIBSON
GRAVITY SEWER TEST 03/12/2019 APPROVED JGIBSON
U - SEWER TIE IN 03/12/2019 APPROVED JGIBSON
PLUMBING 1ST ROUGH UNDERGROUND 03/11/2019 Disapproved -FEE REQUIRED JGIBSON
Note: NEED TO HAVE ON SITE AT TIME OF INSPECTION ALL APPROVED DOCUMENTS AND APPROVED STAMPED PLANS FOR INSPECTION, SEWER TIE IN AND GRAVITY SEWER INSPECTIONS NEED TO BE CALLED IN AS ALL ARE COMPLETED

Review History

Department Status Date In Date Out
SW1 COMPLETE 03/20/2019 03/27/2019
Note: Released By: JHINDMAN
ENGIN1 COMPLETE 02/19/2019 02/19/2019
Note: Released By: TBAKER
SW1 COMPLETE 02/19/2019 02/22/2019
Note: Released By: JHINDMAN
UD1 COMPLETE 02/19/2019 02/25/2019
Note: Released By: MBACON
ZON COMPLETE 02/19/2019 02/19/2019
Note: Released By: AMOBLEY
ELEC COMPLETE 12/27/2018 01/07/2019
Note: Released By: JHINDMAN
SWALE COMPLETE 12/18/2018 12/19/2018
Note: Released By: TBAKER
BLD COMPLETE 12/14/2018 12/21/2018
Note: Released By: JHINDMAN
ELEC HOLD 12/14/2018 12/18/2018
Note: Held By: DREWIS Provide a disconnect for the AHU, NEC 2014 440.14. Provide an additional receptacle for the switch wall in bedroom 3, NEC 2014 210.52. Daniel Rewis 986-4736
ENGIN1 COMPLETE 12/14/2018 12/18/2018
Note: Released By: TBAKER
MECH COMPLETE 12/14/2018 12/21/2018
Note: Released By: JHINDMAN
PLUM COMPLETE 12/14/2018 12/26/2018
Note: Released By: JHINDMAN
SW1 COMPLETE 12/14/2018 12/18/2018
Note: Released By: DREWIS
UD1 COMPLETE 12/14/2018 12/20/2018
Note: Released By: MBACON Gravity Sewer new homes This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
ZON COMPLETE 12/14/2018 12/14/2018
Note: Released By: AMOBLEY

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 06/26/2019
REINSPECTION FEE ¤40.00 06/26/2019
REINSPECTION FEE ¤40.00 06/26/2019
REINSPECTION FEE ¤40.00 06/26/2019
REINSPECTION FEE ¤40.00 06/26/2019
REINSPECTION FEE ¤40.00 06/26/2019
NEW RESIDENTIAL INSPECTIONS ¤462.00 01/11/2019
SITE PLAN 20 ¤20.00 01/11/2019
SURCHARGE FS 533.721 ¤11.90 01/11/2019
SURCHARGE - FS 468.631 ¤17.85 01/11/2019
STORM WATER PERMIT FEES ¤80.00 01/11/2019
3% TRANS IMPACT FEE CREDIT (¤48.96) 01/11/2019
ADMIN FEE ¤20.00 01/11/2019
ELECTRIC FEE ¤198.60 01/11/2019
3% FIRE IMPACT FEE CREDIT (¤6.70) 01/11/2019
IMPACT FEE FIRE ¤223.38 01/11/2019
IMPACT FEE PARKS ¤849.24 01/11/2019
IMPACT FEE SCHOOL ¤3,600.00 01/11/2019
IMPACT FEE TRANSPORTATION ¤1,632.00 01/11/2019
MECHANICAL FEE ¤198.60 01/11/2019
3% PARKS IMPACT FEE CREDIT (¤25.48) 01/11/2019
PLAN CHECK FEE ¤92.40 01/11/2019
PLUMBING FEE ¤198.60 01/11/2019