Permit #2019010439
Permit Details
Status: COED
| Parcel Id: 07-11-31-7011-000A0-0150 |
| Block: 000A0 |
| Subdivision: 2193 - SECTION 11-BELLE TERRE |
| Job Phone: 386-503-0906 |
| Location Address: 1070 PALM COAST PKWY NW |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 03/05/2019 |
| NOC: RECORDED |
| Applicant name: ANTHONY FALLONE |
| Owner: PLAZA AT 1070 OF PALM COAST INC |
|
Address 1600 LAMBERT AVE FLAGLER BEACH, FL 32136 |
| Lot: 0150 |
| Contracted Stated Job Value: ¤25,000.00 |
| Job Description: SUITE 5 "PURDEE'S ITALIAN ICE" |
| Type: CN |
Contractor
FONTANA CONSTRUCTION, INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P.O. BOX 351222 PALM COAST, FL 32137 |
CBC1250596 (Exp: 08/31/2022) | 386-503-0906 | (386)986-1305 |
Sub Contractors
CHRISTOPHER I HALL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
60 COOPER LANE PALM COAST, FL 32137 |
EC13008029 (Exp: 08/31/2028) | 386-225-1937 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
Inspection History
| Type | Request Date | Result | Inspector |
| FIRE FINAL | 06/14/2019 | FINAL APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION DEFICIENCIES NOTED BY INSPECTOR JH PRIOR RESOLVED | |||
| FIRE FINAL | 06/13/2019 | Disapproved - NO FEE | WMILLER |
| Note: THIS IS A REINSPECTION DOORS LOCKED ACCESS NEEDED FOR INSPECTION. STILL NEED ACCESS TO CHECK FOR THE FOLLOWING (WAS HERE AT 0915 DOORS LOCKED | |||
| U-GREASE INTERCEPTOR PRE-INSTALLATION | 06/06/2019 | FINAL APPROVED | JNICHOLS |
| Note: THIS IS A REINSPECTION | |||
| U-GREASE INTERCEPTOR INSTALLED/PLUMBED | 06/06/2019 | FINAL APPROVED | JNICHOLS |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING FINAL | 06/06/2019 | APPROVED | JGIBSON |
| ELECTRIC FINAL | 06/06/2019 | FINAL APPROVED | JHINDMAN |
| BUILDING FINAL | 06/06/2019 | APPROVED | JHINDMAN |
| U-GREASE INTERCEPTOR FLOW/DYE TESTED | 06/06/2019 | FINAL APPROVED | JNICHOLS |
| Note: THIS IS A REINSPECTION | |||
| U - UTILITY COMMERCIAL FINAL | 06/06/2019 | FINAL APPROVED | JNICHOLS |
| Note: THIS IS A REINSPECTION | |||
| U - UTILITY COMMERCIAL FINAL | 06/05/2019 | Disapproved - NO FEE | JNICHOLS |
| FIRE FINAL | 06/05/2019 | Disapproved - NO FEE | JHINDMAN |
| Note: 1. Provide a certified fire extinguisher nfpa 10 | |||
| U-GREASE INTERCEPTOR FLOW/DYE TESTED | 06/05/2019 | Disapproved - NO FEE | JNICHOLS |
| U-GREASE INTERCEPTOR INSTALLED/PLUMBED | 06/05/2019 | Disapproved - NO FEE | JNICHOLS |
| ABOVE CEILING | 06/05/2019 | APPROVED | JHINDMAN |
| U-GREASE INTERCEPTOR PRE-INSTALLATION | 06/05/2019 | Disapproved - NO FEE | JNICHOLS |
| MONOLITHIC SLAB | 03/27/2019 | APPROVED | MWILLIAMS |
| PLUMBING 2ND ROUGH | 03/21/2019 | APPROVED - AS NOTED | JGIBSON |
| Note: THIS WAS INSPECTED ON 3/20/19 WITH THE FIRST ROUGH | |||
| PLUMBING 1ST ROUGH | 03/20/2019 | APPROVED - AS NOTED | JGIBSON |
| Note: , NEED REVISION FOR ''AAV'' PLAN CALLS FOR 'VTR' WILL CHECK AT PLUMBING FINAL. | |||
| ELECTRIC 2ND ROUGH | 03/20/2019 | APPROVED | RMARTIN |
| FRAMING | 03/20/2019 | APPROVED | JHINDMAN |
Review History
| Department | Status | Date In | Date Out |
| PLUM | COMPLETE | 04/03/2019 | 04/18/2019 |
| Note: Released By: RLEE | |||
| UD1 | COMPLETE | 02/26/2019 | 02/26/2019 |
| Note: Released By: CJOHNSON | |||
| UD1 | HOLD | 02/22/2019 | 02/25/2019 |
| Note: Held By: CJOHNSON Plumbing plan and waste riser diagram should show the grease trap. Indicate the size | |||
| UD1 | HOLD | 02/08/2019 | 02/12/2019 |
| Note: Held By: CJOHNSON This unit may require a grease interceptor or grease trap. Please update your grease trap exemption form. The approved form did not indicate soft serve machines. Provide completed DBPR form. I can provide you the appropriate form 386-986-2384 | |||
| ELEC | COMPLETE | 02/08/2019 | 02/22/2019 |
| Note: Released By: JHINDMAN | |||
| BLD | COMPLETE | 01/14/2019 | 01/29/2019 |
| Note: Released By: RLEE | |||
| ELEC | HOLD | 01/14/2019 | 01/29/2019 |
| Note: Held By: JHINDMAN 1. Provide complete electrical load calculatiions for the unit along with panel schedules as the plans do not show all the circuits. 2014 NEC art 220. J. hindman 986-3784. 2. Provide electrical contractor. | |||
| FI1 | COMPLETE | 01/14/2019 | 01/29/2019 |
| Note: Released By: JHINDMAN | |||
| MECH | COMPLETE | 01/14/2019 | 01/29/2019 |
| Note: Released By: RLEE | |||
| PLUM | COMPLETE | 01/14/2019 | 01/29/2019 |
| Note: Released By: RLEE | |||
| UD1 | HOLD | 01/14/2019 | 01/15/2019 |
| Note: Held By: CJOHNSON This facility will require at minimum a grease trap and grease line. Sinks, drains in food service and prep areas will need to be plumbed to grease line. Will need to have an approved grease intereceptor exemption form. Contact me for the required form and with any questions. | |||
| ZON | COMPLETE | 01/14/2019 | 01/15/2019 |
| Note: Released By: JGONZALEZ |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN COMMERCIAL | ¤60.00 | 03/05/2019 |
| INSPECTION - COMMERCIAL ADD | ¤175.00 | 03/05/2019 |
| ELECTRIC FEE | ¤75.00 | 03/05/2019 |
| PLAN CHECK FEE | ¤100.00 | 03/05/2019 |
| PLUMBING FEE | ¤75.00 | 03/05/2019 |
| SITE PLAN 20 | ¤20.00 | 03/05/2019 |
| SURCHARGE FS 533.721 | ¤3.30 | 03/05/2019 |
| SURCHARGE - FS 468.631 | ¤4.95 | 03/05/2019 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤513.25 |