I want to search for...

Permit #2019020262

Permit Details

Status: COED

Parcel Id: 07-11-31-7015-00020-0960
CONDITIONED SPACE: 1819 sqft
GARAGE: 665 sqft
OPENED PORCH (WITH ROOF) : 55 sqft
OPENED PORCH (WITH ROOF) : 225 sqft
SCREEN PORCH (SOLID ROOF) : 890 sqft
Total Square Footage: 3654 sqft
Block: 00020
Subdivision: 2194 - SECTION 15-COUNTRY CLUB COVE
Job Phone: (386) 446-5850
Location Address: 62 COCHISE CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/05/2019
NOC: RECORDED
Applicant name: CHARLES DALLAS RINEK
Owner: PADDLEFORD GEORGE S III & LORI FOREMAN H&W

Address

10345 EAST PANTERA AVENUE

MESA, AZ 85212

Lot: 0960
Contracted Stated Job Value: ¤231,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

CHARLES RINEK CONSTRUCTION, INC.
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 352502

Palm Coast, FL 32137

CGC046080 (Exp: 08/31/2026) (386) 446-5850 (386)445-9992

Sub Contractors

JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
THOMAS A REGULA
Status Location Address State License Number Phone Fax
INACTIVE

11320 PHILLIPS PKWY DRIVE E

JACKSONVILLE, FL 32256

CMC1250075 (Exp: 08/31/2026) 904-278-0339 904-278-0366
ERIC FRANCO
Status Location Address State License Number Phone
CANCEL

840 DELTONA BLVD SUITE F-2

SANFORD, FL 32771

CCC1327280 (Exp: 08/31/2022) 386-575-4007
CHARLES K DAVIS
Status Location Address State License Number Phone
ACTIVE

3000 E MOODY BLVD BLDG 2

BUNNELL , FL 32110

EC13004270 (Exp: 08/31/2026) 386-931-6614

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 03/27/2020 FINAL APPROVED JDELBONIS
Note: THIS IS A REINSPECTION need fall protecion around wall out back
BLD - BUILDING FINAL 03/20/2020 Disapproved - NO FEE JDELBONIS
Note: need fall protecion around wall out back
ROW - FINAL APRON (AFTER POUR) 03/19/2020 APPROVED RGROSS
ROW - DRAINAGE 03/19/2020 APPROVED RGROSS
ROW - STORMWATER FINAL 03/19/2020 APPROVED - AS NOTED RGROSS
Note: ON SITE WITH SUB CONTRACTOR IN THE PROCESS OF BUILDING A BURME ALONG THE RIGHT SIDE PROPERTY LINE TO PREVENT STORM WATER FROM FLOWING ONTO THE ADJACENT LOT. ALSO PLACING SOD ACROSS THE STREET IN THE ROW WHERE CONTRACOTR TRUCKS WERE PARKING.
U -UTILITY RESIDENTIAL FINAL 03/19/2020 APPROVED AHALL
ROW FIELD SURVEY /GRADING CERTIFICATION 03/17/2020 APPROVED - AS NOTED RGROSS
Note: DRAINAGE ALONG THE LEFT SIDE PROPERTY LINE WILL NEED SWALED TO AVOID STORMWATER FLOWING ONTO THE ADJACENT PROPERTY BEFORE THE FINAL STORMWATER CAN BE APPROVED.
FINAL SURVEY (OFFICE USE ONLY) 03/17/2020 CANCELLED BY APPLICANT RGROSS
Note: Note: This inspection was accidently cancelled by the inspector. Sent to permit technician to have it rescheduled the same day.
FINAL SURVEY (OFFICE USE ONLY) 03/17/2020 APPROVED RGROSS
Note: THIS IS A REINSPECTION
ROW- PRE-APRON (PRE-POUR) 02/20/2020 APPROVED - AS NOTED MMAJEWSKI
Note: THIS IS A REINSPECTION APPROVED FOR BRICK PAVERS MATERIAL MUST BE COMPACTED
ROW- PAVER RESTRAINTS 02/14/2020 APPROVED RGROSS
ROW- PRE-APRON (PRE-POUR) 02/14/2020 PARTIALLY APPROVED RGROSS
Note: APPROVED FOR CONCRETE OVER CULVERT, APRON AND PAVER RESTRAINTS.
FOOTER 02/11/2020 APPROVED JDELBONIS
RETAINING WALL 01/27/2020 APPROVED JDELBONIS
RETAINING WALL FOUNDATION 01/13/2020 APPROVED JDELBONIS
U - SEWER TIE IN 12/05/2019 APPROVED JGIBSON
GRAVITY SEWER TEST 12/05/2019 APPROVED JGIBSON
ELECTRIC - EARLY POWER 09/30/2019 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED POWER 3:30
LATH/BRICK/ WATER BARRIER 08/19/2019 CANCELLED BY APPLICANT WEB
LATH/BRICK/ WATER BARRIER 08/19/2019 APPROVED MWILLIAMS
INSULATION 08/08/2019 APPROVED WMILLER
Note: THIS IS A REINSPECTION
INSULATION 08/01/2019 Disapproved - NO FEE WMILLER
Note: STILL MISSING ENTRY DOOR FROM GARAGE INTO HOME (REQUESTED AT ALL-ROUGH ENERGY CALCS CALL FOR R-20 INSULATION AT ROOF DECK... R-38 BATTS WERE INSTALLED AT CEILING... NEED REVISION
ALL ROUGH 07/24/2019 APPROVED - AS NOTED WMILLER
Note: NEED THE FOLLOWING BY INSULATION... 1. NEED ENTRY DOORS INSTALLED 2. TIGHTEN GROUND LUG ON METAL BOX AT LOW VOLTAGE CONSOLE ALL METAL BOXES SHALL BE GROUNDED R,E 3905.2 AND NEC.314.4 3. NAIL PLATES FBC… R, M1308.2 PROTECTION FROM PHYSICAL DAMAGE… IF PIPE IS LESS THAN 1.5” FROM EDGE IT MUST BE PROTECTED WITH A MINIMUM OF 16 GAGE STEEL PLATE AND PLATE MUST EXTEND A MINIMUM OF 2” ABOVE THE SOLE PLATES AND BELOW THE TOP PLATES (LIQUID LI)NES AT BOTTOM PLATE IN GARAGE 4. NEED TO BOX OUT AROUND DRYER EXHAUST (OUT OF WALL) 5. 5ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) 6. MISSING FASTENERS AT SLIDER TRACK AND WINDOWS (CHECK ALL) 7. CHECK INSULATION ON HOT SUPPLY IN ATTIC SPACE (SOME IS FALLING OFF)
ROOF VALLEY & METAL 07/17/2019 APPROVED WMILLER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/04/2019 APPROVED WMILLER
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/03/2019 Disapproved -FEE REQUIRED WMILLER
Note: THIS IS A REINSPECTION 1. MISSING FASTENERS AT HTU26 BUCKETS 2. UNDER DRIVEN FASTENERS AT HTU26 BUCKETS 3. MISSING HETA20 STRAPPS PER PLAN 4. CONTINUOUS LOAD PATH… R301,2.1 OVERFRAMING NOT TIED TO STRUCTURAL MEMBERS BENEATH (ROOF SHEATHING PASSED)
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/29/2019 Disapproved -FEE REQUIRED WMILLER
Note: 1. MISSING HTU 26 BUCKETS PER PLAN 2. MISSING FASTENERS AT HTU26 BUCKETS 3. UNDER DRIVEN FASTENERS AT HTU26 BUCKETS 4. MISSING HETA20 STRAPPS PER PLAN 5. CONTINUOUS LOAD PATH… R301,2.1 OVERFRAMING NOT TIED TO STRUCTURAL MEMBERS BENEATH 6. 6X6 POSTS NOT SET PER PLANS AT DETAIL -A 7. 6X6 POST HARDWARE/STRAPS MISSING PER PLANS AT DETAIL -A
TIE BEAM / LINTEL 05/02/2019 APPROVED WMILLER
Note: THIS WAS APPROVED PRIOR ON 4-26-2017 BY INSPECTOR LM
ELECTRIC-TUG 05/02/2019 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED POWER 3:00
TIE BEAM / LINTEL 04/26/2019 APPROVED WMILLER
FOUND SURVEY APPROVED (OFFICE) 04/25/2019 APPROVED JHINDMAN
MONOLITHIC SLAB 04/03/2019 APPROVED WMILLER
PLUMBING 1ST ROUGH UNDERGROUND 03/29/2019 APPROVED JGIBSON

Review History

Department Status Date In Date Out
PLFM COMPLETE 03/16/2020 03/16/2020
Note: Released By: JMYERS Elevation certificates are not required.
ENGIN1 COMPLETE 02/10/2020 02/11/2020
Note: Released By: TBAKER
SW1 COMPLETE 02/10/2020 02/13/2020
Note: Released By: CTROHA
UD1 COMPLETE 02/10/2020 02/10/2020
Note: Released By: AHALL
ZON COMPLETE 02/10/2020 02/11/2020
Note: Released By: AMOBLEY
ZON COMPLETE 02/04/2020 02/04/2020
Note: Released By: AMOBLEY
BLD COMPLETE 02/04/2020 02/10/2020
Note: Released By: PBUCKLEY
ZON COMPLETE 02/04/2020 02/05/2020
Note: Released By: ELENS Please check to verify if any changes were made that may affect zoning regs.
ZON COMPLETE 12/06/2019 12/09/2019
Note: Released By: ELENS
BLD COMPLETE 11/11/2019 11/18/2019
Note: Released By: PBUCKLEY
ZON HOLD 11/11/2019 11/12/2019
Note: Held By: TDOAK Provide dimensions of all proposed walkways not on original approved site plan. Note that walkways cannot exceed 6' wide. Provide material to be used for all proposed walkways not on original approved site plan. Demonstrate that proposed walkway on left side of home does not encroach into 5' utility easement by providing setback. Provide the setback of the proposed paver patio which is rearmost of the property to the rear property line to demonstrate that it does not encroach into the setback. Plans for the retaining wall must state that the wall will be finished to match the home.
SW1 COMPLETE 11/11/2019 11/12/2019
Note: Released By: CTROHA
ZON COMPLETE 10/02/2019 10/02/2019
Note: Released By: AMOBLEY
MECH COMPLETE 08/02/2019 08/07/2019
Note: Released By: JHINDMAN
BLD COMPLETE 07/16/2019 07/19/2019
Note: Released By: JHINDMAN
SW1 COMPLETE 04/24/2019 04/25/2019
Note: Released By: JHINDMAN Foundation S
BLD COMPLETE 03/29/2019 04/05/2019
Note: Released By: JHINDMAN
ZON COMPLETE 02/22/2019 02/25/2019
Note: Released By: AMOBLEY
PLFM COMPLETE 02/22/2019 02/22/2019
Note: Released By: JMYERS Based on the Site Plan submitted 2/22/19 the structure is outside of the Special Flood Hazard Area. No elevation certificates will be required.
ENGIN1 COMPLETE 02/22/2019 02/25/2019
Note: Released By: TBAKER
SW1 COMPLETE 02/22/2019 03/01/2019
Note: Released By: JHINDMAN
PLUM COMPLETE 02/22/2019 03/01/2019
Note: Released By: JHINDMAN
ELEC COMPLETE 02/22/2019 03/01/2019
Note: Released By: JHINDMAN
ENGIN1 HOLD 02/13/2019 02/13/2019
Note: Held By: TBAKER Elevations on survey differ from COPC GPS by .4'
PLFM HOLD 02/08/2019 02/08/2019
Note: Held By: JMYERS According to City of Palm Coast mapping resources, the subject property has an “AE” zone which is a Special Flood Hazard Area (SFHA) located on it. Please provide an updated Site Plan that shows the extent of the Flood Zone. Should the structure fall inside the Flood Zone, elevation certificates will be required at Construction Drawings, Foundation, and Final.
SWALE COMPLETE 02/08/2019 02/28/2019
Note: Released By: TBAKER
BLD COMPLETE 02/07/2019 02/14/2019
Note: Released By: RLEE
ELEC HOLD 02/07/2019 02/14/2019
Note: Held By: JHINDMAN 1. Provide electrical load calculations per 2014 NEc art.220.2. Provide a service riser with conductors sized for a 300 amp service. 2014 NEC Table 310 15B16.
ENGIN1 COMPLETE 02/07/2019 02/08/2019
Note: Released By: TBAKER
MECH COMPLETE 02/07/2019 02/14/2019
Note: Released By: RLEE
PLUM HOLD 02/07/2019 02/14/2019
Note: Held By: JHINDMAN 1. Provide a plumbing riser diagram signed and sealed or signed by the plumbing contractor with theitr signature
SW1 HOLD 02/07/2019 02/14/2019
Note: Held By: RLEE Proposed drainage at side lots seems to drain onto adjacent properties. Positive outfall to be maintained on property.
UD1 COMPLETE 02/07/2019 02/08/2019
Note: Released By: MBACON Gravity Sewer new homes This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
ZON HOLD 02/07/2019 02/08/2019
Note: Held By: AMOBLEY 1. Elevations labeled incorrectly on page A6 2. Garages can not exceed the maximum depth of 30' 3. Please remove all the accessory work at the rear of property on Survey/Site plan as this permit is for the house only 4. Survey/Site plan should have total lot square footage 5. Survey/Site plan has the incorrect section in the description 6. Please show total driveway and walkway width on the Survey/Site plan
ZON HOLD 02/03/2019 02/04/2020
Note: Held By: ELENS Please provide original Right of Way Utilization Agreement for recording.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤40.00 02/10/2020
CONTRACTOR CHANGE ¤40.00 02/10/2020
RECORDING FEE REIMBURSE DOC ¤44.00 02/10/2020
REINSPECTION FEE ¤40.00 02/10/2020
REINSPECTION FEE ¤40.00 02/10/2020
NEW RESIDENTIAL INSPECTIONS ¤482.00 03/05/2019
SITE PLAN 20 ¤20.00 03/05/2019
SURCHARGE FS 533.721 ¤12.32 03/05/2019
SURCHARGE - FS 468.631 ¤18.48 03/05/2019
STORM WATER PERMIT FEES ¤80.00 03/05/2019
3% TRANS IMPACT FEE CREDIT (¤48.96) 03/05/2019
IMPACT FEE TRANSPORTATION ¤1,632.00 03/05/2019
MECHANICAL FEE ¤204.60 03/05/2019
3% PARKS IMPACT FEE CREDIT (¤25.48) 03/05/2019
PLAN CHECK FEE ¤96.40 03/05/2019
PLUMBING FEE ¤204.60 03/05/2019
ELECTRIC FEE ¤204.60 03/05/2019
3% FIRE IMPACT FEE CREDIT (¤6.70) 03/05/2019
IMPACT FEE FIRE ¤223.38 03/05/2019
IMPACT FEE PARKS ¤849.24 03/05/2019
IMPACT FEE SCHOOL ¤3,600.00 03/05/2019
ADMIN FEE ¤20.00 03/05/2019
Fees Total Due: ¤0.00 Total Paid: ¤7,770.48