Permit #2019030016

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7037-00330-0040
CONDITIONED SPACE: 1179 sqft
Total Square Footage: 1179 sqft
Block: 00330
Subdivision: 2176 - SECTION 37-LAKEVIEW
Job Phone: 386-931-1905
Location Address: 35 LAMONT LN
Type: BA - BUILDING ADDITION
Issue Date: 04/24/2019
NOC: RECORDED
Applicant name: RICHARD JAMES SMITH
Owner: MCDONOUGH MARVIN W & ROSEANNA M H&W

Address

35 LAMONT LANE

PALM COAST, FL 32137

Lot: 0040
Contracted Stated Job Value: ¤140,000.00
Job Description: ADDITION
Type: CN

Contractor

HAMMOCK COMMUNITIES INC
Status Location Address State License Number Phone
ACTIVE

725 NORTH OCEANSHORE BLVD

FLAGLER BEACH, FL 32136

CGC1516033 (Exp: 08/31/2026) 386-693-4947

Sub Contractors

MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
KENNETH J LEANDRO SR
Status Location Address State License Number Phone
CANCEL

115 N 2ND STREET

FLAGLER BEACH, FL 32136

ER13015308 (Exp: 08/31/2022) 386-569-4139
MARTIN JOHN EVANS
Status Location Address State License Number
ACTIVE

14 FORT CAROLINE CT

BUNNELL, FL 32110

CFC057676 (Exp: 08/31/2026)

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 09/30/2020 FINAL APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION 210.12 Arc-Fault Circuit-Interrupter Protection. (A) Dwelling Units. All 120-volt, single phase, 15- and 20-ampere branch circuits supplying outlets installed in dwelling unit family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, or similar rooms or areas shall be protected by a listed arc-fault circuit interrupter, combination-type, installed to provide protection of the branch circuit. (NEED FOR ADDITION LIVING AREA).... NEED TO GROUT OR CAULK TOILET.... NEED LOCKING CAPS ON NEW AC UNIT
ROW - FINAL APRON (AFTER POUR) 09/29/2020 APPROVED GBERTOLA
Note: THIS IS A REINSPECTION SOUR CLEAN OUT ON THECONCRETE FLOOR NEED A FLAT CAP TRIPPING HAUZARD-09/29/2020 FIXED FLAT CAP ON IT
ROW - FINAL APRON (AFTER POUR) 09/28/2020 Disapproved - NO FEE GBERTOLA
Note: SOUR CLEAN OUT ON THECONCRETE FLOOR NEED A FLAT CAP TRIPPING HAUZARD
BLD - BUILDING FINAL 09/28/2020 Disapproved -FEE REQUIRED JCOLASANTI
Note: 210.12 Arc-Fault Circuit-Interrupter Protection. (A) Dwelling Units. All 120-volt, single phase, 15- and 20-ampere branch circuits supplying outlets installed in dwelling unit family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, or similar rooms or areas shall be protected by a listed arc-fault circuit interrupter, combination-type, installed to provide protection of the branch circuit. (NEED FOR ADDITION LIVING AREA).... NEED TO GROUT OR CAULK TOILET.... NEED LOCKING CAPS ON NEW AC UNIT
U -UTILITY RESIDENTIAL FINAL 08/11/2020 FINAL APPROVED JHARDING
FINAL SURVEY (OFFICE USE ONLY) 08/03/2020 APPROVED RGROSS
FOOTER 12/02/2019 APPROVED JCOLASANTI
INSULATION 08/30/2019 APPROVED JCOLASANTI
ALL ROUGH 08/21/2019 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
LATH/BRICK/ WATER BARRIER 08/15/2019 APPROVED JDELBONIS
ALL ROUGH 08/15/2019 Disapproved -FEE REQUIRED JDELBONIS
Note: need nail plates on both sides of wall where AC lins run through cant see pluming and electric where sheetrock is leaning against walls no 5 foot head preshure on pluming drain lines
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/01/2019 APPROVED MWILLIAMS
TIE BEAM / LINTEL 05/30/2019 APPROVED JCOLASANTI
FOUND SURVEY APPROVED (OFFICE) 05/29/2019 APPROVED JHINDMAN
MONOLITHIC SLAB 05/09/2019 APPROVED MWILLIAMS
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB 05/01/2019 Disapproved -FEE REQUIRED JCOLASANTI
Note: 12 inch MINIMUM DEPTH , UNDISTURBED GROUND SURFACE… R403.1.3.4 and in accordance with R401.2, and R403.1 ALL FOOTINGS SHALL BE PLACED AT LEAST 12 in. BELOW THE UNDISTURBED GROUND SURFACE......NEED TEST FOR COMPACTION TO 95% PROCTOR DENSITY PER PLANS....stand alone footing needs to be 18" deep per plan(total area of footing) FBC 802
PLUMBING 1ST ROUGH UNDERGROUND 04/26/2019 APPROVED JGIBSON

Review History

Department Status Date In Date Out
ZON COMPLETE 11/18/2019 11/18/2019
Note: Released By: TDOAK
ZON HOLD 11/15/2019 11/15/2019
Note: Held By: TDOAK Site plan must include all dimensions of revised walkways connecting left side of garage to addition and concrete patio.
BLD COMPLETE 11/08/2019 11/15/2019
Note: Released By: PBUCKLEY
BLD COMPLETE 08/29/2019 09/03/2019
Note: Released By: MGARRETT
ELEC COMPLETE 07/10/2019 07/11/2019
Note: Released By: JHINDMAN
BLD COMPLETE 06/25/2019 07/01/2019
Note: Released By: JHINDMAN
BLD COMPLETE 05/29/2019 06/05/2019
Note: Released By: JHINDMAN
SW1 COMPLETE 05/22/2019 05/29/2019
Note: Released By: JHINDMAN
BLD HOLD 05/13/2019 05/20/2019
Note: Held By: JHINDMAN 1. Provide an original signed and sealed engineers letter.A copy of a digital signature is not valid.
ZON COMPLETE 03/25/2019 03/26/2019
Note: Released By: AMOBLEY
ZON HOLD 03/18/2019 03/20/2019
Note: Held By: AMOBLEY Foundation plantings must continue along patio and wrap corner of patio since it faces a right of way
ELEC COMPLETE 03/18/2019 03/25/2019
Note: Released By: JHINDMAN
PLUM COMPLETE 03/18/2019 03/25/2019
Note: Released By: JHINDMAN provide a minimum 3" drain to water closet.
BLD COMPLETE 03/01/2019 03/07/2019
Note: Released By: JHINDMAN
ELEC HOLD 03/01/2019 03/07/2019
Note: Held By: JHINDMAN 1. Provide electrical load calculations for the house with the additional loads for the addition 2014 NEC art 220. 2. Provide a disconnect for ahu2.
MECH COMPLETE 03/01/2019 03/07/2019
Note: Released By: JHINDMAN
PLUM HOLD 03/01/2019 03/07/2019
Note: Held By: JHINDMAN 1. Provide a signed and sealed plumbing riser diagram or a riser signed by the plumbing contractor with their license number on it.6th ed. FBC 107.1.
SW1 COMPLETE 03/01/2019 03/07/2019
Note: Released By: JHINDMAN
ZON HOLD 03/01/2019 03/04/2019
Note: Held By: AMOBLEY Must have banding wrapping the corner at least 2ft on addition Single family residence can only have one door facing the front Please provide a landscape plan Have to draw up the easement release agreement and send to city utilities for release. Once agreement is drawn up we will send to you for the homeowners to sign and get notarized

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 09/29/2020
CONTRACTOR CHANGE ¤40.00 09/25/2020
REINSPECTION FEE ¤40.00 09/25/2020
REINSPECTION FEE ¤40.00 09/25/2020
ADMIN FEE ¤20.00 04/24/2019
ELECTRIC FEE ¤144.00 04/24/2019
RECORDING FEE REIMBURSE DOC ¤35.50 04/24/2019
MECHANICAL FEE ¤144.00 04/24/2019
PLAN CHECK FEE ¤56.00 04/24/2019
PLUMBING FEE ¤144.00 04/24/2019
REMODEL/ADDITION/ACCES INSPECT ¤56.00 04/24/2019
SITE PLAN 20 ¤20.00 04/24/2019
SURCHARGE FS 533.721 ¤5.84 04/24/2019
SURCHARGE - FS 468.631 ¤8.76 04/24/2019
STORM WATER PERMIT FEES ¤80.00 04/24/2019
Fees Total Due: ¤0.00 Total Paid: ¤874.10