Permit #2019030474

Permit Details

Status: COED

Parcel Id: 07-11-31-7003-0013W-0010
CONDITIONED SPACE: 1850 sqft
GARAGE: 497 sqft
OPENED PORCH (WITH ROOF) : 56 sqft
OPENED PORCH (WITH ROOF) : 671 sqft
Total Square Footage: 3074 sqft
Block: 0013W
Subdivision: 2190 - SECTION 3-COUNTRY CLUB COVE
Job Phone: 386-338-1755
Location Address: 74 CLUB HOUSE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/28/2019
NOC: RECORDED
Applicant name: SOPHAN KES
Owner: GIOIA PROPERTIES LLC

Address

PO BOX 352918

PALM COAST, FL 32135

Lot: 0010
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

KES CONSTRUCTION INC
Status Location Address State License Number Phone
INACTIVE

107 BURROUGHS

PALM COAST, FL 32164

CRC1332024 (Exp: 08/31/2022) 386-338-1755

Sub Contractors

CHRISTOPHER I HALL
Status Location Address State License Number Phone
ACTIVE

60 COOPER LANE

PALM COAST, FL 32137

EC13008029 (Exp: 08/31/2028) 386-225-1937
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
ROBERT JAMES BARROW JR
Status Location Address Mailing Address State License Number Phone
ACTIVE

2323 N STATE ST

BUNNELL, FL 32110

UNIT 126

BUNNELL, FL 32110

CAC1817890 (Exp: 08/31/2026) 386-627-5500
DANIEL J LUSINSKI
Status Location Address Mailing Address State License Number Phone
ACTIVE

389 PALM COAST PARKWAY SW

PALM COAST, FL 32137

#4

PALM COAST, FL 32137

CCC1330133 (Exp: 08/31/2026) 386-338-7926

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/13/2019 FINAL APPROVED JDELBONIS
Note: THIS IS A REINSPECTION
ROW - STORMWATER FINAL 12/13/2019 APPROVED - AS NOTED RGROSS
Note: THIS IS A REINSPECTION. OAK TREE MOVED OUT OF THE EASEMENT.
U -UTILITY RESIDENTIAL FINAL 12/12/2019 APPROVED AHALL
ROW - FINAL APRON (AFTER POUR) 12/12/2019 APPROVED RGROSS
ROW - STORMWATER FINAL 12/12/2019 Disapproved - NO FEE RGROSS
Note: OAK TREE ON THE LEFT PROPERTY LINE NEEDS REMOVED FROM THE EASEMANT. Sec 42.55
BLD - BUILDING FINAL 12/12/2019 Disapproved -FEE REQUIRED JDELBONIS
Note: GFCI in lundry room GFCI on master tub lights out side doors entry, back garage door, veranda INSULATION CERTIFICATE R303.1.1.2 INSTALLER SHALL SIGN DATE AND POST CERTIFICATE IN A CONSPICUOUS LOCATION
ROW FIELD SURVEY /GRADING CERTIFICATION 12/11/2019 APPROVED - AS NOTED RGROSS
Note: NEW OAK TREE NEAR THE RIGHT SIDE PROPERTY LINE WILL NEED MOVED OUT OF THE 5' EASEMANT BEFORE FINAL ROW CAN BE APPROVED.
FINAL SURVEY (OFFICE USE ONLY) 12/11/2019 APPROVED RGROSS
ELECTRIC - EARLY POWER 11/15/2019 APPROVED - AS NOTED RMARTIN
Note: EMAILED FPL RELEASED POWER 2:40
ROW- PRE-APRON (PRE-POUR) 11/07/2019 APPROVED RGROSS
TUB SET 10/10/2019 APPROVED JGIBSON
U - SEWER TIE IN 10/07/2019 APPROVED JGIBSON
WATER METER INSTALLATION REQUEST 09/06/2019 APPROVED CSTONE
LATH/BRICK/ WATER BARRIER 08/07/2019 APPROVED WMILLER
INSULATION 08/02/2019 APPROVED - AS NOTED WMILLER
Note: THIS IS A REINSPECTION 1. call in tub set when jaccuzi tub is set prior to closing in framing
INSULATION 08/01/2019 Disapproved - NO FEE WMILLER
Note: THE FOLLOWING WAS REQUESTED BY INSULATION AND IS STILL DEFICIENT... 1. call in tub set when jaccuzi tub is set prior to closing in framing 2. Missing can light over jaccuzi tub 3. OUTLETS WITHIN 6 feet OF DOORS… NEC 210.52 (bedroom 3) ALSO NEED FIRE FOAM AT FIREBLOCKING (FRONT OF GARAGE SEPARATION WALL)
ALL ROUGH 07/29/2019 APPROVED - AS NOTED WMILLER
Note: THIS IS A REINSPECTION 1. call in tub set when jaccuzi tub is set prior to closing in framing 2. NAIL PLATES FBC… R, M1308.2 PROTECTION FROM PHYSICAL DAMAG. (range vent) 3. NEED TO SEAL DRYER DUCT AT ROOF WITH MASTIC..FBC.. M1502.4.2 AND M1601.4.1… 4. Missing can light over jaccuzi tub 5. OUTLETS WITHIN 6 feet OF DOORS… NEC 210.52 (bedroom 3) 6. missing passive returns (check all 7. minimum clearance from wall to ductboard plenum not met (4")
ALL ROUGH 07/26/2019 Disapproved - NO FEE WMILLER
Note: DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL (need the APPROVED paperwork on site at time of final) (PAPERWORK WAS NOT THE APPROVED PAPERWORK)
ROOF VALLEY & METAL 07/12/2019 APPROVED WMILLER
Note: THIS IS A REINSPECTION
ROOF VALLEY & METAL 07/09/2019 Disapproved - NO FEE WMILLER
Note: (6TH EDITION) FASTENERS FOR UNDERLAYMENT AS REQUIRED, R905.1.1, AND TABLE 905.1.1 (1 -3) AND R905.1.1 EXEPTION, (SYNTHETIC UNDERLAMENT) OVERLAPS FASTENED 6 inches OC,
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/27/2019 APPROVED - AS NOTED WMILLER
Note: THIS IS A REINSPECTION WILL LOOK FOR THE FOLLOWING AT ALL-ROUGH STILL MISSING FASTENERS AT STRAP ON BACK PORCH (THIS IS NOW CIRCLED IN HIGHLIGHTER AND PEN ON PLANS. ALSO APPROVED PLANS ARE NO LONGER ON SITE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/25/2019 Disapproved - NO FEE WMILLER
Note: THIS IS A REINSPECTION MIISING STRAPS, MISSING FASTERS ATT STRAPS, MISSING FASTENERS AT ADDED STRAPS, NEED TO UNCOVER STRAP AT TRUSS T06 (FRONT OF HOUSE, OVER FRAMING NOT TIED TO UNDER FRAMING, CONTINUOUS LOAD PATH… R301,2.1 OVERFRAMING NOT TIED TO STRUCTURAL MEMBERS BENEATH (ALL HIGHLIGHTED ON PLANS)
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/20/2019 PARTIALLY APPROVED WMILLER
Note: looked at roof sheathing and down cells only per onsite supervisor
TIE BEAM / LINTEL 06/04/2019 APPROVED WMILLER
Note: THIS IS A REINSPECTION
TIE BEAM / LINTEL 06/03/2019 Disapproved -FEE REQUIRED WMILLER
Note: CLEARANCE FROM MASONRY (6TH EDITION) R606.3.4 MINIMUM WALL REINFORCING STEEL COVERAGE NOT MET (.75 INCH) (marked on plans)
FOUND SURVEY APPROVED (OFFICE) 05/31/2019 APPROVED JHINDMAN
MONOLITHIC SLAB 05/15/2019 Disapproved - NO FEE WMILLER
Note: NEED COMPACTION REPORT PER PLANS
MONOLITHIC SLAB 05/15/2019 APPROVED - AS NOTED WMILLER
Note: THIS IS A REINSPECTION THIS WAS FAILED EARLIER TODAY WITH NO FEE FOR NO COMPACTION REPORT (RICH CALLED AND SAID THE COMPACTION IS IN THE BOX SO I RETURNED AND FOUND IT IN THE BOX THEREFORE THE RESULT IS APPROVED
PLUMBING 1ST ROUGH UNDERGROUND 05/14/2019 APPROVED JGIBSON
GRAVITY SEWER TEST 05/14/2019 APPROVED JGIBSON
STEM WALL FOUNDATION 04/16/2019 APPROVED WMILLER

Review History

Department Status Date In Date Out
SW1 COMPLETE 05/28/2019 05/31/2019
Note: Released By: JHINDMAN Foundation S
ZON COMPLETE 03/21/2019 03/21/2019
Note: Released By: AMOBLEY
MECH COMPLETE 03/21/2019 03/27/2019
Note: Released By: JHINDMAN
PLFM COMPLETE 03/15/2019 03/15/2019
Note: Released By: JMYERS According to the Site Plan submitted 3/14/19 the structure will be outside of the Special Flood Hazard Area that resides on the property. No elevation certificates will be required.
BLD COMPLETE 03/14/2019 03/21/2019
Note: Released By: JHINDMAN
ELEC COMPLETE 03/14/2019 03/21/2019
Note: Released By: JHINDMAN
ENGIN1 COMPLETE 03/14/2019 03/18/2019
Note: Released By: TBAKER
MECH HOLD 03/14/2019 03/21/2019
Note: Held By: JHINDMAN 1.Page 1 of form R405 is missing the contractors signature. 6th ed. FBC ECR405.
PLUM COMPLETE 03/14/2019 03/21/2019
Note: Released By: JHINDMAN
SW1 COMPLETE 03/14/2019 03/21/2019
Note: Released By: JHINDMAN
UD1 COMPLETE 03/14/2019 03/19/2019
Note: Released By: AHALL Gravity Sewer new homes This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. The NFPA Clear Zone distance there can be no obstacles in front of the Hydrant and 3.0’ on both sides and 4’ behind.
ZON HOLD 03/14/2019 03/15/2019
Note: Held By: AMOBLEY Due to lot size one more tree is required

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 12/23/2019
REINSPECTION FEE ¤40.00 12/23/2019
NEW RESIDENTIAL INSPECTIONS ¤512.00 03/28/2019
SITE PLAN 20 ¤20.00 03/28/2019
SURCHARGE FS 533.721 ¤12.95 03/28/2019
SURCHARGE - FS 468.631 ¤19.43 03/28/2019
STORM WATER PERMIT FEES ¤80.00 03/28/2019
3% TRANS IMPACT FEE CREDIT (¤89.43) 03/28/2019
ADMIN FEE ¤20.00 03/28/2019
ELECTRIC FEE ¤213.60 03/28/2019
3% FIRE IMPACT FEE CREDIT (¤6.70) 03/28/2019
IMPACT FEE FIRE ¤223.38 03/28/2019
IMPACT FEE PARKS ¤849.24 03/28/2019
IMPACT FEE SCHOOL ¤3,600.00 03/28/2019
IMPACT FEE TRANSPORTATION ¤2,981.00 03/28/2019
MECHANICAL FEE ¤213.60 03/28/2019
3% PARKS IMPACT FEE CREDIT (¤25.48) 03/28/2019
PLAN CHECK FEE ¤102.40 03/28/2019
PLUMBING FEE ¤213.60 03/28/2019
Fees Total Due: ¤0.00 Total Paid: ¤9,019.59