I want to search for...
Permit #2019030854
Permit Details
Status: COED
| Parcel Id: 07-11-31-7024-00280-0360 |
| CONDITIONED SPACE: 1875 sqft |
| GARAGE: 516 sqft |
| OPENED PORCH (WITH ROOF) : 213 sqft |
| OPENED PORCH (WITH ROOF) : 48 sqft |
| Total Square Footage: 2652 sqft |
| Block: 00280 |
| Subdivision: 2167 - SECTION 24-PINE GROVE |
| Job Phone: 407-807-0656 |
| Location Address: 36 PRICE LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/18/2019 |
| NOC: Unknown |
| Applicant name: NAVIN SUGRIM |
| Owner: DLP BRITE HOMES LLC |
|
Address 605 PALENCIA CLUB DRIVE ST AUGUSTINE, FL 32095 |
| Lot: 0360 |
| Contracted Stated Job Value: ¤147,660.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
DLP BUILDERS LLC
| Status | Location Address | State License Number | Phone |
| CANCEL |
7345 GREENBRIAR PKWY ORLANDO, FL 32819 |
CBC1263567 (Exp: 08/31/2022) | 407-807-0656 |
Sub Contractors
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| CANCEL |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2022) | 877-906-1113 |
ROBERT G DELLO RUSSO
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
531 CODISCO WAY SANFORD, FL 32771 |
CAC032448 (Exp: 08/31/2022) | (407)831-2665 | (407)333-3853 |
THOMAS WALTER ALBANO
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P. O. BOX 352075 Palm Coast, FL 32135 |
CFC045991 (Exp: 08/31/2024) | 386-437-2795 | (386)437-2781 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 01/17/2020 | FINAL APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION DEFICIENCIES NOTED BY INSPECTOR JC PRIOR ON 1/15/2020 RESOLVED | |||
| BLD - BUILDING FINAL | 01/15/2020 | Disapproved - NO FEE | JCOLASANTI |
| Note: THIS IS A REINSPECTION SD shall not be installed less than10' horizontally from a permanently cooking appliance FBC 313.3.1.2....electrical switch cover in master bath needs screws | |||
| BLD - BUILDING FINAL | 01/14/2020 | Disapproved -FEE REQUIRED | JDELBONIS |
| Note: THIS IS A REINSPECTION door locked again need acess to complet inspection | |||
| BLD - BUILDING FINAL | 12/20/2019 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: THIS IS A REINSPECTION doors locked need access to complete inspection | |||
| BLD - BUILDING FINAL | 12/18/2019 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: THIS IS A REINSPECTION Need to seal hole at AHU whip and ceiling at vent both in AC closet.. guest bath exhaust not working | |||
| BLD - BUILDING FINAL | 12/17/2019 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: door locked | |||
| ROW - FINAL APRON (AFTER POUR) | 12/17/2019 | APPROVED | RGROSS |
| ROW - STORMWATER FINAL | 12/17/2019 | APPROVED | RGROSS |
| U -UTILITY RESIDENTIAL FINAL | 12/17/2019 | FINAL APPROVED | LFITZGERALD |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/16/2019 | APPROVED | RGROSS |
| FINAL SURVEY (OFFICE USE ONLY) | 12/16/2019 | APPROVED | RGROSS |
| ROW- PRE-APRON (PRE-POUR) | 11/20/2019 | APPROVED - AS NOTED | MMAJEWSKI |
| Note: IT IS THE BUILDER’S RESPONSIBILITY: TO RECHECK ELEVATIONS AND PIPE SIZE, TO INSURE THAT AN OBSTRUCTION DOES NOT EXIST UPSTREAM AND OR DOWNSTREAM, THAT THE CULVERT PIPE IS SET TO AND OR FOLLOWS THE SWALE PLAN, FORM THE DRIVEWAY TO THE APPROVEDSITE PLAN AND FOLLOW THE APPROVED DRIVEWAY DETAIL SHEET PROVIDED BY THE CITY OF PALM COAST. PRIOR TO PLACEMENT OF CONCRETE | |||
| U - SEWER TIE IN | 11/01/2019 | APPROVED | JDELBONIS |
| GRAVITY SEWER TEST | 11/01/2019 | APPROVED | JDELBONIS |
| ELECTRIC - EARLY POWER | 10/29/2019 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 11:00 | |||
| LATH/BRICK/ WATER BARRIER | 08/28/2019 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 08/23/2019 | Disapproved - NO FEE | JCOLASANTI |
| Note: need two layers of felt over wood at ceiling front entrance | |||
| INSULATION | 08/20/2019 | APPROVED | JDELBONIS |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 08/16/2019 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: THIS IS A REINSPECTION/Bump-out top plate and install nail plate at dryer duct | |||
| INSULATION | 08/15/2019 | Disapproved - NO FEE | FWILLIS |
| Note: Top plate needed on vent pipe in laundry room. | |||
| ALL ROUGH | 08/12/2019 | APPROVED | JDELBONIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/22/2019 | APPROVED | JDELBONIS |
| Note: THIS IS A REINSPECTION | |||
| ROOF VALLEY & METAL | 07/18/2019 | APPROVED | JDELBONIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/12/2019 | Disapproved - NO FEE | FWILLIS |
| Note: Truss R17 (3 ply) missing THD210 straps as called out on approved plans page S1.0 Right side of entryway down cell under bond beam off to the right. | |||
| ELECTRIC-TUG | 06/25/2019 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO DELL FPL RELEASED POWER 3:30 | |||
| TIE BEAM / LINTEL | 06/24/2019 | APPROVED | MWILLIAMS |
| FOUND SURVEY APPROVED (OFFICE) | 06/13/2019 | APPROVED | JMUNSON |
| MONOLITHIC SLAB | 06/11/2019 | APPROVED | JCOLASANTI |
| MONOLITHIC SLAB | 06/10/2019 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: need approved plans on site to complete inspection FBC 102 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 05/28/2019 | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 06/12/2019 | 06/13/2019 |
| Note: Released By: JMUNSON | |||
| BLD | COMPLETE | 04/08/2019 | 04/15/2019 |
| Note: Released By: JHINDMAN | |||
| PLUM | COMPLETE | 04/08/2019 | 04/15/2019 |
| Note: Released By: JHINDMAN | |||
| SWALE | COMPLETE | 03/25/2019 | 04/01/2019 |
| Note: Released By: TBAKER | |||
| BLD | HOLD | 03/22/2019 | 03/28/2019 |
| Note: Held By: JHINDMAN 1. Provide a digital signature with cwertification that can be validatedon the plan without going to a 3rd party website. Florida Aministrative Code 61g-15-23. J. Hindman 986-3784. | |||
| ELEC | COMPLETE | 03/22/2019 | 03/28/2019 |
| Note: Released By: JHINDMAN | |||
| ENGIN1 | COMPLETE | 03/22/2019 | 03/25/2019 |
| Note: Released By: TBAKER | |||
| MECH | COMPLETE | 03/22/2019 | 03/28/2019 |
| Note: Released By: JHINDMAN | |||
| PLUM | HOLD | 03/22/2019 | 03/28/2019 |
| Note: Held By: JHINDMAN 1. Provide a digital signature with cwertification that can be validatedon the plan without going to a 3rd party website. Florida Aministrative Code 61g-15-23. J. Hindman 986-3784. | |||
| SW1 | COMPLETE | 03/22/2019 | 03/28/2019 |
| Note: Released By: JHINDMAN | |||
| UD1 | COMPLETE | 03/22/2019 | 03/27/2019 |
| Note: Released By: AHALL PEP Tank areas new home This is a PEP Tank area. The Pep Panel will be placed 5 feet from the front corner of the building on the same side of the building as the PEP tank that is marked on the Utility marked Site plan. Make sure the electrician places the PEP power wire between 3 feet and 5 feet from the ground. The plumber should exit the slab with the sewer pipe on the side of the building the tank will be on and matching the utility marked site plan, this will reduce any piping under driveways or sidewalks and minimize the fall required. The sewer tie-in inspection must be called in the day before the tie-in. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in visual inspection so he can witness the tie-in. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap | |||
| ZON | COMPLETE | 03/22/2019 | 03/25/2019 |
| Note: Released By: AMOBLEY |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 05/01/2020 |
| REINSPECTION FEE | ¤40.00 | 02/18/2020 |
| REINSPECTION FEE | ¤40.00 | 02/18/2020 |
| REINSPECTION FEE | ¤40.00 | 02/18/2020 |
| REINSPECTION FEE | ¤40.00 | 02/18/2020 |
| REINSPECTION FEE | ¤40.00 | 12/05/2019 |
| REINSPECTION FEE | ¤40.00 | 08/13/2019 |
| CONTRACTOR CHANGE | ¤40.00 | 08/13/2019 |
| ADMIN FEE | ¤20.00 | 04/18/2019 |
| NEW RESIDENTIAL INSPECTIONS | ¤480.00 | 04/18/2019 |
| SURCHARGE FS 533.721 | ¤12.28 | 04/18/2019 |
| SURCHARGE - FS 468.631 | ¤18.42 | 04/18/2019 |
| STORM WATER PERMIT FEES | ¤80.00 | 04/18/2019 |
| 3% TRANS IMPACT FEE CREDIT | (¤48.96) | 04/18/2019 |
| ELECTRIC FEE | ¤204.00 | 04/18/2019 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.70) | 04/18/2019 |
| IMPACT FEE FIRE | ¤223.38 | 04/18/2019 |
| IMPACT FEE PARKS | ¤849.24 | 04/18/2019 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 04/18/2019 |
| IMPACT FEE TRANSPORTATION | ¤1,632.00 | 04/18/2019 |
| MECHANICAL FEE | ¤204.00 | 04/18/2019 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 04/18/2019 |
| PLAN CHECK FEE | ¤96.00 | 04/18/2019 |
| PLUMBING FEE | ¤204.00 | 04/18/2019 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤7,862.18 |