I want to search for...
Permit #2019030861
Permit Details
Status: COED
| Parcel Id: 07-11-31-7028-00140-0300 |
| CONDITIONED SPACE: 1683 sqft |
| GARAGE: 558 sqft |
| OPENED PORCH (WITH ROOF) : 40 sqft |
| OPENED PORCH (WITH ROOF) : 214 sqft |
| Total Square Footage: 2495 sqft |
| Block: 00140 |
| Subdivision: 2199 - SECTION 28-WYNNFIELD |
| Job Phone: 407-807-0656 |
| Location Address: 57 PONCE DELEON DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/06/2019 |
| NOC: RECORDED |
| Applicant name: NAVIN SUGRIM |
| Owner: BRITE PROPERTIES OF FLORIDA LLC |
|
Address 619 EAST WASHINGTON STREET ORLANDO, FL 32802 |
| Lot: 0300 |
| Contracted Stated Job Value: ¤140,878.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
DLP BUILDERS LLC
| Status | Location Address | State License Number | Phone |
| CANCEL |
7345 GREENBRIAR PKWY ORLANDO, FL 32819 |
CBC1263567 (Exp: 08/31/2022) | 407-807-0656 |
Sub Contractors
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| CANCEL |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2022) | 877-906-1113 |
ROBERT G DELLO RUSSO
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
531 CODISCO WAY SANFORD, FL 32771 |
CAC032448 (Exp: 08/31/2022) | (407)831-2665 | (407)333-3853 |
THOMAS WALTER ALBANO
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P. O. BOX 352075 Palm Coast, FL 32135 |
CFC045991 (Exp: 08/31/2024) | 386-437-2795 | (386)437-2781 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/11/2020 | FINAL APPROVED | MMESSER |
| ROW - FINAL APRON (AFTER POUR) | 05/11/2020 | APPROVED | MMAJEWSKI |
| ROW - FINAL INSPECTION | 05/11/2020 | APPROVED | MMAJEWSKI |
| U -UTILITY RESIDENTIAL FINAL | 05/11/2020 | FINAL APPROVED | LFITZGERALD |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/07/2020 | APPROVED | MMAJEWSKI |
| FINAL SURVEY (OFFICE USE ONLY) | 05/07/2020 | APPROVED | MMAJEWSKI |
| ROW- PRE-APRON (PRE-POUR) | 01/29/2020 | APPROVED | MMAJEWSKI |
| Note: THIS IS A REINSPECTION | |||
| ROW- PRE-APRON (PRE-POUR) | 01/28/2020 | Disapproved -FEE REQUIRED | MMAJEWSKI |
| Note: NO SWALE PLAN ON SITE FORM BOARD AT EDGE OF PAVEMENT IS BROKEN | |||
| U - SEWER TIE IN | 01/08/2020 | APPROVED | JGIBSON |
| GRAVITY SEWER TEST | 01/08/2020 | APPROVED | JGIBSON |
| ELECTRIC - EARLY POWER | 01/08/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 3:55 | |||
| PEP TANK INSTALLATION REQUEST | 12/13/2019 | APPROVED | CSTONE |
| LATH/BRICK/ WATER BARRIER | 11/20/2019 | APPROVED | WMILLER |
| INSULATION | 11/18/2019 | APPROVED | FWILLIS |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 11/14/2019 | Disapproved -FEE REQUIRED | JDELBONIS |
| Note: THIS IS A REINSPECTION fire stopping missing everywhere | |||
| INSULATION | 11/04/2019 | Disapproved - NO FEE | JDELBONIS |
| Note: damage was done a lot of the electric was cut and removed | |||
| ALL ROUGH | 10/28/2019 | APPROVED | FWILLIS |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 10/08/2019 | Disapproved -FEE REQUIRED | JDELBONIS |
| Note: no water on no 5 foot head pressure pluming needs nail plates electric needs nail plates | |||
| ROOF VALLEY & METAL | 09/18/2019 | APPROVED | JDELBONIS |
| ELECTRIC-TUG | 09/13/2019 | APPROVED | JDELBONIS |
| Note: TALKED TO SUSAN AT FPL 2:50 9/13/19 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/10/2019 | APPROVED | JDELBONIS |
| TIE BEAM / LINTEL | 08/21/2019 | APPROVED | JDELBONIS |
| FOUND SURVEY APPROVED (OFFICE) | 08/20/2019 | APPROVED | JMUNSON |
| MONOLITHIC SLAB | 08/14/2019 | APPROVED | JDELBONIS |
| PLUMBING 1ST ROUGH UNDERGROUND | 08/12/2019 | APPROVED | JGIBSON |
| WATER METER INSTALLATION REQUEST | 07/16/2019 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 08/20/2019 | 08/20/2019 |
| Note: Released By: JMUNSON Foundation Survey | |||
| BLD | COMPLETE | 04/08/2019 | 04/15/2019 |
| Note: Released By: JHINDMAN | |||
| PLUM | COMPLETE | 04/08/2019 | 04/15/2019 |
| Note: Released By: JHINDMAN | |||
| UD1 | COMPLETE | 04/08/2019 | 04/11/2019 |
| Note: Released By: AHALL PEP Tank areas new home This is a PEP Tank area. The Pep Panel will be placed 5 feet from the front corner of the building on the same side of the building as the PEP tank that is marked on the Utility marked Site plan. Make sure the electrician places the PEP power wire between 3 feet and 5 feet from the ground. The plumber should exit the slab with the sewer pipe on the side of the building the tank will be on and matching the utility marked site plan, this will reduce any piping under driveways or sidewalks and minimize the fall required. The sewer tie-in inspection must be called in the day before the tie-in. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in visual inspection so he can witness the tie-in. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap | |||
| SWALE | COMPLETE | 03/25/2019 | 04/01/2019 |
| Note: Released By: TBAKER | |||
| BLD | HOLD | 03/22/2019 | 03/28/2019 |
| Note: Held By: JHINDMAN 1. Provide a digital signature with cwertification that can be validatedon the plan without going to a 3rd party website. Florida Aministrative Code 61g-15-23. J. Hindman 986-3784. | |||
| ELEC | COMPLETE | 03/22/2019 | 03/28/2019 |
| Note: Released By: JHINDMAN | |||
| ENGIN1 | COMPLETE | 03/22/2019 | 03/25/2019 |
| Note: Released By: TBAKER | |||
| LOCATE | COMPLETE | 03/22/2019 | 03/25/2019 |
| Note: Released By: CSTONE | |||
| MECH | COMPLETE | 03/22/2019 | 03/28/2019 |
| Note: Released By: JHINDMAN | |||
| PLUM | HOLD | 03/22/2019 | 03/28/2019 |
| Note: Held By: JHINDMAN 1. Provide a digital signature with cwertification that can be validatedon the plan without going to a 3rd party website. Florida Aministrative Code 61g-15-23. J. Hindman 986-3784. | |||
| SW1 | COMPLETE | 03/22/2019 | 03/28/2019 |
| Note: Released By: JHINDMAN | |||
| UD1 | HOLD | 03/22/2019 | 03/27/2019 |
| Note: Held By: AHALL PEP Panel not shown on electrical plans (Builder Electrical Plan see page 2.) PEP Panel is not shown in the electrical plan. Submit a new electrical plan showing PEP Panel on the building on the same side of the building as indicated in the Utility marked site plan. COPC utilizes pep or gravity sanitary sytems | |||
| ZON | COMPLETE | 03/22/2019 | 03/25/2019 |
| Note: Released By: AMOBLEY |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 05/06/2020 |
| REINSPECTION FEE | ¤40.00 | 02/18/2020 |
| REINSPECTION FEE | ¤40.00 | 12/05/2019 |
| REINSPECTION FEE | ¤40.00 | 12/05/2019 |
| CONTRACTOR CHANGE | ¤40.00 | 08/13/2019 |
| ADMIN FEE | ¤20.00 | 06/06/2019 |
| NEW RESIDENTIAL INSPECTIONS | ¤440.00 | 06/06/2019 |
| SITE PLAN 20 | ¤20.00 | 06/06/2019 |
| SURCHARGE FS 533.721 | ¤11.44 | 06/06/2019 |
| SURCHARGE - FS 468.631 | ¤17.16 | 06/06/2019 |
| STORM WATER PERMIT FEES | ¤80.00 | 06/06/2019 |
| 3% TRANS IMPACT FEE CREDIT | (¤48.96) | 06/06/2019 |
| ELECTRIC FEE | ¤192.00 | 06/06/2019 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.70) | 06/06/2019 |
| IMPACT FEE FIRE | ¤223.38 | 06/06/2019 |
| IMPACT FEE PARKS | ¤849.24 | 06/06/2019 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 06/06/2019 |
| IMPACT FEE TRANSPORTATION | ¤1,632.00 | 06/06/2019 |
| MECHANICAL FEE | ¤192.00 | 06/06/2019 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 06/06/2019 |
| PLAN CHECK FEE | ¤88.00 | 06/06/2019 |
| PLUMBING FEE | ¤192.00 | 06/06/2019 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤7,676.08 |