I want to search for...

Permit #2019031020

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7014-00020-2180
Block: 00020
Subdivision: 2202 - SECTION 14-COUNTRY CLUB COVE
Job Phone: 386-503-0906
Location Address: 16 CEDARVIEW CT
Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION
Issue Date: 04/26/2019
NOC: RECORDED
Applicant name: ANTHONY FALLONE
Owner: SUSAN JOYALLE

Address

16 CEDARVIEW CT

PALM COAST, FL 32137

Lot: 2180
Contracted Stated Job Value: ¤7,000.00
Job Description: RENOVATION OF KITCHEN & LAUNDRY ROOM
Type: CN

Contractor

FONTANA CONSTRUCTION, INC.
Status Location Address State License Number Phone Fax
CANCEL

P.O. BOX 351222

PALM COAST, FL 32137

CBC1250596 (Exp: 08/31/2022) 386-503-0906 (386)986-1305

Sub Contractors

HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
CHRISTOPHER I HALL
Status Location Address State License Number Phone
ACTIVE

60 COOPER LANE

PALM COAST, FL 32137

EC13008029 (Exp: 08/31/2028) 386-225-1937

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 01/21/2020 FINAL APPROVED JDELBONIS
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 11/15/2019 Disapproved -FEE REQUIRED JDELBONIS
Note: GFCI next to sink not triping rangetop walloven and microwave need lock out brakers or disconects
LATH/BRICK/ WATER BARRIER 07/26/2019 APPROVED WMILLER
Note: THIS IS A REINSPECTION
LATH/BRICK/ WATER BARRIER 07/10/2019 Disapproved - NO FEE WMILLER
Note: CORNER BEADS NEEDED, 7/8 inch MINIMUM THICKNESS, TABLE R702.1 (1) SEVEN EIGHTHS OF AN INCH REQUIRED OVER WIRE LATH AND SHEATHING (EXTRERIOR)
INSULATION 05/22/2019 APPROVED - AS NOTED WMILLER
Note: need to correct the following between top plate and roof deck by final (can see it in attic from scuttle hole) dryer exhaust must have smooth interior finish and shall be constructed of metal having a 0.0157 inches. The duct shall be 4 inches nominal in diamerter M1502.4.1 (6th edition)
ALL ROUGH 05/20/2019 APPROVED - AS NOTED WMILLER
Note: THIS IS A REINSPECTION NEED TO SEE DRYER EXHAUST CONNECTED BY INSULATION INSPECTION
ALL ROUGH 05/16/2019 Disapproved -FEE REQUIRED WMILLER
Note: 1. NAIL PLATES ON ELECTRIC FBC E3802.1 (table), AND 3802.3.2 (locations marked on plans 2. JUNCTION BOXES IN MUST BE ACCESSIBLE NEC 314.29 3. GROUND WIRES, GROUND WIRES MUST BE MADE UP NEC 110.14a 4. MISSING DRYER EXHAUST 5. ELECTRIC NOT MATCHING PLANS (MISSING OUTLETS AND LIGHTS
FRAMING 05/13/2019 APPROVED - AS NOTED WMILLER
Note: THIS IS A REINSPECTION window framing only
WALL SHEATHING 05/13/2019 APPROVED WMILLER
Note: THIS IS A REINSPECTION inspection was added because it was ready and contractor forgot to call it in
WALL SHEATHING 05/10/2019 Disapproved - NO FEE WMILLER
Note: KNOCKED AND RANG DOORBELL (NO ANSWER), ACCESS NEEDED FOR INSPECTION.
FRAMING 05/10/2019 Disapproved -FEE REQUIRED WMILLER
Note: KNOCKED AND RANG DOORBELL (NO ANSWER), ACCESS NEEDED FOR INSPECTION.
MONOLITHIC SLAB 05/09/2019 APPROVED WMILLER
PLUMBING 1ST ROUGH UNDERGROUND 05/06/2019 APPROVED JGIBSON

Review History

Department Status Date In Date Out
BLD COMPLETE 05/21/2019 05/29/2019
Note: Released By: JHINDMAN
ZON COMPLETE 04/18/2019 04/18/2019
Note: Released By: AMOBLEY
PLUM COMPLETE 04/18/2019 04/25/2019
Note: Released By: JHINDMAN
ELEC COMPLETE 04/18/2019 04/25/2019
Note: Released By: JHINDMAN
BLD COMPLETE 04/18/2019 04/25/2019
Note: Released By: JHINDMAN
BLD HOLD 04/03/2019 04/09/2019
Note: Held By: RLEE 1. Provide engineers plans for removal and enclosing existing windows, and installation of new windows. 2. Provide FLorida Product Approval for new window. 3. Provide identification whether existing garage waall to be removed is loadbearing. Provide engineers plan for removal and replacement.
ELEC HOLD 04/03/2019 04/09/2019
Note: Held By: RLEE Provide electrical riser diagram with contractors name and license
PLUM HOLD 04/03/2019 04/09/2019
Note: Held By: RLEE Provide plumbing riser diagram with contractors name and license.
ZON HOLD 04/03/2019 04/03/2019
Note: Held By: TDOAK Drawings submitted show what appears to be some exterior changes to windows and/or doors. Please provide drawings of proposed exterior elevations and note that the exterior willl be finished/painted to match the existing. Also, if the existing windows/doors have stucco banding, the new ones will be required to as well. If there are new windows/doors facing the saltwater canal, it is a requirement of the LDC that these windows/doors have banding.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 01/20/2020
REINSPECTION FEE ¤40.00 11/14/2019
REINSPECTION FEE ¤40.00 11/14/2019
CONTRACTOR CHANGE ¤40.00 11/14/2019
REVISION ¤40.00 11/14/2019
SITE PLAN 20 ¤20.00 04/26/2019
SURCHARGE FS 533.721 ¤2.48 04/26/2019
SURCHARGE - FS 468.631 ¤3.73 04/26/2019
ADMIN FEE ¤20.00 04/26/2019
ELECTRIC FEE ¤64.20 04/26/2019
PLAN CHECK FEE ¤40.00 04/26/2019
PLUMBING FEE ¤64.20 04/26/2019
REMODEL/ADDITION/ACCES INSPECT ¤40.00 04/26/2019
Fees Total Due: ¤0.00 Total Paid: ¤454.61