I want to search for...

Permit #2019070848

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7031-00580-0320
Block: 00580
Subdivision: 2166 - SECTION 31-ROYAL PALMS
Job Phone: 386-503-0906
Location Address: 23 RIVERSIDE LN
Type: BA - BUILDING ADDITION
Issue Date: 08/08/2019
NOC: RECORDED
Applicant name: ANTHONY FALLONE
Owner: MILLS NANCY

Address

23 RIVERSIDE LANE

PALM COAST, FL 32164

Lot: 0320
Contracted Stated Job Value: ¤10,000.00
Job Description: ADDING COVERED PORCH TO EXISITING PATIO
Type: CN

Contractor

FONTANA CONSTRUCTION, INC.
Status Location Address State License Number Phone Fax
CANCEL

P.O. BOX 351222

PALM COAST, FL 32137

CBC1250596 (Exp: 08/31/2022) 386-503-0906 (386)986-1305

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 11/27/2019 FINAL APPROVED FWILLIS
ROW - FINAL INSPECTION 11/27/2019 APPROVED MMAJEWSKI
U -UTILITY RESIDENTIAL FINAL 11/27/2019 FINAL APPROVED MBACON
Note: Permit was not accessible
LATH/BRICK/ WATER BARRIER 10/15/2019 APPROVED FWILLIS
Note: THIS IS A REINSPECTION
LATH/BRICK/ WATER BARRIER 10/14/2019 Disapproved -FEE REQUIRED FWILLIS
Note: WIRE LATHE FASTENERS, PER FBC R703.7.1... Shall be attached 1 1/2 inch long 11 gage nails having a 7/16 inch head, or 7/8 inch long 16 gage staples, spaced no more than 6 inches. Secure all areas that need lath. CORNER BEADS NEEDED, 7/8 inch MINIMUM THICKNESS, TABLE R702.1 (1) SEVEN EIGHTHS OF AN INCH REQUIRED OVER WIRE LATH AND SHEATHING (EXTRERIOR)
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/20/2019 APPROVED JDELBONIS
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/18/2019 Disapproved -FEE REQUIRED DROCKWELL
Note: Plans not available to Inspector...No one answered door
FOOTER 08/09/2019 APPROVED FWILLIS
Note: Inspection was for 3 footers.

Review History

Department Status Date In Date Out
BLD COMPLETE 07/23/2019 07/29/2019
Note: Released By: JHINDMAN
SW1 COMPLETE 07/23/2019 07/23/2019
Note: Released By: JMUNSON
ZON COMPLETE 07/23/2019 07/23/2019
Note: Released By: AMOBLEY

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 11/26/2019
REINSPECTION FEE ¤40.00 11/26/2019
REMODEL/ADDITION/ACCES INSPECT ¤40.00 08/08/2019
SITE PLAN 20 ¤20.00 08/08/2019
SURCHARGE FS 533.721 ¤2.00 08/08/2019
SURCHARGE - FS 468.631 ¤2.00 08/08/2019
STORM WATER PERMIT FEES ¤80.00 08/08/2019
ADMIN FEE ¤20.00 08/08/2019
PLAN CHECK FEE ¤40.00 08/08/2019
Fees Total Due: ¤0.00 Total Paid: ¤284.00