Permit #2019080021
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7035-00830-0050 |
| CONDITIONED SPACE: 728 sqft |
| OPENED PORCH (WITH ROOF) : 112 sqft |
| Total Square Footage: 840 sqft |
| Block: 00830 |
| Subdivision: 2172 - SECTION 35-BELLE TERRE |
| Job Phone: 386-547-8383 |
| Location Address: 35 BUFFALO GROVE DR |
| Type: BA - BUILDING ADDITION |
| Issue Date: 08/19/2019 |
| NOC: RECORDED |
| Applicant name: MICHAEL P CANNON |
| Owner: ALEXANDER GEORGE W & SUSAN H&W |
|
Address 35 BUFFALO GROVE DRIVE PALM COAST, FL 32137 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤57,766.00 |
| Job Description: WORKOUT AND FAMILY ROOM ADDITION |
| Type: CN |
Contractor
CANNON HOME SERVICES INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
39 PUTTER DR PALM COAST, FL 32164 |
CBC1259826 (Exp: 08/31/2026) | 386-547-8383 |
Sub Contractors
JOHN EDWARD GAMBONE
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
15 HARGROVE LN PALM COAST, FL 32137 |
1G PALM COAST, FL 32137 |
EC13006037 (Exp: 08/31/2026) | 386-586-9144 |
DANIEL DAVID RUTKOWSKI III
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1687 STATE AVENUE HOLLY HILL, FL 32117 |
CCC1328639 (Exp: 08/31/2026) | 386-290-7490 | 386-256-0001 |
THOMAS A REGULA
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
11320 PHILLIPS PKWY DRIVE E JACKSONVILLE, FL 32256 |
CMC1250075 (Exp: 08/31/2026) | 904-278-0339 | 904-278-0366 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 01/17/2020 | FINAL APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| ROW - FINAL INSPECTION | 01/16/2020 | APPROVED - AS NOTED | RGROSS |
| Note: LITTLE MORE FILL NEEDED ON THE POOL SIDE OF THE BUILDING TO PREVENT WATER FROM LAYING AGAINST THE FOUNDATION. ON SITE WITH HOMEOWNER WHO STARTED PROCESS BEFORE INSPECTOR LEFT. | |||
| U -UTILITY RESIDENTIAL FINAL | 01/16/2020 | APPROVED | AHALL |
| BLD - BUILDING FINAL | 01/16/2020 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: MOCP RATING NOT MATCHING BREAKERS MFBC 1303 (unit calls for 15amp max breaker 20amp installed).....ARCH FAULT REQUIRED 210.12 Arc-Fault Circuit-Interrupter Protection. (A) Dwelling Units. All 120-volt, single phase, 15- and 20-ampere branch circuits supplying outlets installed in dwelling unit family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, or similar rooms or areas shall be protected by a listed arc-fault circuit interrupter, combination-type, installed to provide protection of the branch circuit. | |||
| FINAL SURVEY (OFFICE USE ONLY) | 01/15/2020 | APPROVED | RGROSS |
| LATH/BRICK/ WATER BARRIER | 11/26/2019 | APPROVED | FWILLIS |
| INSULATION | 11/22/2019 | APPROVED | JCOLASANTI |
| ALL ROUGH | 11/20/2019 | APPROVED - AS NOTED | JCOLASANTI |
| Note: METAL BOXES SHALL BE GROUNDED NEC.314.4 (front entance door) | |||
| FOUND SURVEY APPROVED (OFFICE) | 11/20/2019 | APPROVED | CTROHA |
| ROOF VALLEY & METAL | 11/04/2019 | APPROVED | JCOLASANTI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/30/2019 | APPROVED - AS NOTED | JCOLASANTI |
| Note: Mike called to schedule this inspection need to add second strap to hip girders....need two add two collar ties as plan calls for each rafter | |||
| TIE BEAM / LINTEL | 10/11/2019 | APPROVED | JCOLASANTI |
| MONOLITHIC SLAB | 09/24/2019 | APPROVED | JCOLASANTI |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 11/19/2019 | 11/20/2019 |
| Note: Released By: CTROHA Foundation Survey | |||
| BLD | COMPLETE | 09/13/2019 | 09/20/2019 |
| Note: Released By: MGARRETT | |||
| MECH | COMPLETE | 08/12/2019 | 08/19/2019 |
| Note: Released By: MGARRETT | |||
| ELEC | COMPLETE | 08/12/2019 | 08/15/2019 |
| Note: Released By: JMUNSON | |||
| ZON | COMPLETE | 08/06/2019 | 08/07/2019 |
| Note: Released By: AMOBLEY | |||
| BLD | COMPLETE | 08/01/2019 | 08/07/2019 |
| Note: Released By: JHINDMAN | |||
| ELEC | HOLD | 08/01/2019 | 08/07/2019 |
| Note: Held By: JHINDMAN Provide wire size and type and circuit size for the subpanel feeders. 2014 nec table 310 15 b 16. | |||
| MECH | HOLD | 08/01/2019 | 08/07/2019 |
| Note: Held By: JHINDMAN 1. page 1 of form R405 and the EPL display card are missing signatures. | |||
| PLUM | CANCEL | 08/01/2019 | 08/07/2019 |
| SW1 | COMPLETE | 08/01/2019 | 08/01/2019 |
| Note: Released By: JMUNSON | |||
| ZON | HOLD | 08/01/2019 | 08/02/2019 |
| Note: Held By: AMOBLEY Please provide side and rear setbacks on site plan from proposed addition to property line |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 01/16/2020 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 08/19/2019 |
| SITE PLAN 20 | ¤20.00 | 08/19/2019 |
| SURCHARGE FS 533.721 | ¤3.03 | 08/19/2019 |
| SURCHARGE - FS 468.631 | ¤4.55 | 08/19/2019 |
| STORM WATER PERMIT FEES | ¤80.00 | 08/19/2019 |
| ADMIN FEE | ¤20.00 | 08/19/2019 |
| ELECTRIC FEE | ¤111.60 | 08/19/2019 |
| MECHANICAL FEE | ¤111.60 | 08/19/2019 |
| PLAN CHECK FEE | ¤40.00 | 08/19/2019 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤470.78 |