I want to search for...

Permit #2019080269

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7057-00030-0080
Block: 00030
Subdivision: 2123 - SECTION 57-ULYSSES TREES
Job Phone: (386)253-7774
Location Address: 77 UTICA PATH
Type: ME - MECHANICAL
Issue Date: 08/08/2019
NOC: Unknown
Applicant name: STEVEN KEITH JONES
Owner: PRESSLEY DAVID R & ALEXIS A H&W

Address

77 UTICA PATH

PALM COAST, FL 32164

Lot: 0080
Contracted Stated Job Value: ¤6,100.00
Job Description: 4 TON, 16 SEER
Type: CN

Contractor

D G MEYER INC
Status Mailing Address State License Number Phone Fax
ACTIVE

345 MADISON AVE

DAYTONA BEACH, FL 32114

CMC057027 (Exp: 08/31/2026) (386)253-7774 (386)255-9431

Inspection History

Type Request Date Result Inspector
HVAC FINAL 09/17/2019 FINAL APPROVED CPISCITELLI
Note: THIS IS A REINSPECTION
HVAC FINAL 08/26/2019 Disapproved -FEE REQUIRED CPISCITELLI
Note: MOCP RATING NOT MATCHING BREAKERS MFBC 1303 (Breaker for AHU calls for 50 AMP at 230V. The 45 AMP is for 208V. Breaker needs to be changed to 50 AMP

Review History

Department Status Date In Date Out
MECH COMPLETE 08/07/2019 08/07/2019
Note: Released By: JHINDMAN

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 09/12/2019
SURCHARGE FS 533.721 ¤2.00 08/08/2019
SURCHARGE - FS 468.631 ¤2.00 08/08/2019
ADMIN FEE ¤20.00 08/08/2019
INSPECTION 40 ¤40.00 08/08/2019
Fees Total Due: ¤0.00 Total Paid: ¤104.00