Permit #2019080937
Permit Details
Status: FINAL
| Parcel Id: 06-12-31-5825-00000-0220 |
| Block: 00000 |
| Subdivision: 2111 - TOWN CENTER PHASE II |
| Job Phone: 386-437-1257 |
| Location Address: 10000 COASTAL TRACE BLDG 8 |
| Type: FU - FIRE UNDERGROUND |
| Issue Date: 11/05/2019 |
| NOC: Unknown |
| Applicant name: CHELSEA MARIE BARNEY |
| Owner: CENTRAL LANDINGS PARTNERS LTD & CENTRAL LANDINGS 8 |
|
Address 335 N KNOWLES AVE STE 101 WINTER PARK, FL 32789 |
| Lot: 0220 |
| Contracted Stated Job Value: ¤18,478.00 |
| Job Description: BLDG. 8- UNDERGROUND FIRE LINE WITH FDC, DCDA AND IN BUILDING RISER. |
| Type: CN |
Contractor
4C'S TRUCKING & EXCAVATION INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 2682 BUNNELL, FL 32110 |
FPC15-000050 (Exp: 06/30/2026) | 386-437-1257 | 386-437-4468 |
Inspection History
| Type | Request Date | Result | Inspector |
| FIRE FINAL | 03/30/2020 | FINAL APPROVED | WMILLER |
| FIRE SYSTEM FLUSH | 12/03/2019 | APPROVED | WMILLER |
| Note: added at the request of Mike on site | |||
| FIRE MAIN HYDROSTATIC/BACKFLOW PREVENTOR | 12/03/2019 | APPROVED | WMILLER |
| Note: Added at the request of Contractor | |||
| FIRE MAIN PLACEMENT /SIZE/THRUST /BLOCKING | 11/22/2019 | APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION | |||
| FIRE MAIN PLACEMENT /SIZE/THRUST /BLOCKING | 11/06/2019 | PARTIALLY APPROVED | WMILLER |
| Note: Looked at riser, riser thrust, and riser to plastic pipe restraint only. |
Review History
| Department | Status | Date In | Date Out |
| FI1 | COMPLETE | 10/28/2019 | 11/04/2019 |
| Note: Released By: WMILLER | |||
| FI1 | HOLD | 10/22/2019 | 10/28/2019 |
| Note: Held By: WMILLER Please upload the correct file for review (only an image of the adobe acrobat reader was uploaded) | |||
| FI1 | HOLD | 10/08/2019 | 10/16/2019 |
| Note: Held By: WMILLER Hold per conversation with Designer/architect | |||
| FI1 | HOLD | 10/07/2019 | 10/08/2019 |
| Note: Held By: WMILLER Please upload the drawings for review (only a picture of the Adobe reader was uploaded) | |||
| FI1 | HOLD | 09/11/2019 | 09/25/2019 |
| Note: Held By: WMILLER I spoke with Teresa Benton (with the Engineers of Record, Gulf Stream Design) Who approached me onsight and asked if I knew what the status of this Review was. I explained the FDC is now shown located with parking in front or it. I explained I wanted to make sure if they had to Hash out the Parking space it wasnt going to cause Problems on the Building Approvals. She stated she had an easy solution and is going to move the Fdc to a location that will not have parking space in front of it. Please upload revision as soon as possible. | |||
| FI1 | HOLD | 09/06/2019 | 09/11/2019 |
| Note: Held By: WMILLER Revision needed to relocate FDC within 100 feet of supply | |||
| FI1 | HOLD | 08/23/2019 | 09/05/2019 |
| Note: Held By: WMILLER Please show distance between Supply and FDC... Fire Department Connection within 100' of the hydrant (NFPA 14 6.4.5.4.0 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN COMMERCIAL | ¤60.00 | 11/05/2019 |
| FIRE PLANS REVIEW | ¤40.00 | 11/05/2019 |
| SURCHARGE FS 533.721 | ¤2.00 | 11/05/2019 |
| SURCHARGE - FS 468.631 | ¤2.00 | 11/05/2019 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤104.00 |