I want to search for...
Permit #2019081219
Permit Details
Status: COED
| Parcel Id: 48-11-31-1710-00000-1130 |
| CONDITIONED SPACE: 2470 sqft |
| GARAGE: 706 sqft |
| OPENED PORCH (WITH ROOF) : 46 sqft |
| OPENED PORCH (WITH ROOF) : 440 sqft |
| Total Square Footage: 3662 sqft |
| Block: 0 |
| Subdivision: 2177 - GRAND HAVEN NORTH PHASE II |
| Job Phone: 386-445-2012 |
| Location Address: 9 BLUE OAK LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/11/2019 |
| NOC: RECORDED |
| Applicant name: JOHN NICHOLAS CORDASCI |
| Owner: FREY BRUCE A & GERMAINE |
|
Address HICKS TRUSTEES LOUDON, TX 37774 |
|
Address 103 WAYNOKA LANE LOUDON, TX 37774 |
| Lot: 1130 |
| Contracted Stated Job Value: ¤313,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SKYWAY BUILDERS INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 354786 PALM COAST, FL 32135 |
CBC1263769 (Exp: 08/31/2024) | 386-445-2012 |
Sub Contractors
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
DANIEL DAVID RUTKOWSKI III
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1687 STATE AVENUE HOLLY HILL, FL 32117 |
CCC1328639 (Exp: 08/31/2026) | 386-290-7490 | 386-256-0001 |
THOMAS A REGULA
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
11320 PHILLIPS PKWY DRIVE E JACKSONVILLE, FL 32256 |
CMC1250075 (Exp: 08/31/2026) | 904-278-0339 | 904-278-0366 |
MARK JOHN LUTCZA
| Status | Location Address | State License Number | Phone |
| ACTIVE |
26 ROYAL LEAF LANE PALM COAST, FL 32164 |
EC13005145 (Exp: 08/31/2026) | 386-586-0770 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 08/04/2020 | FINAL APPROVED | LFITZGERALD |
| Note: THIS IS A REINSPECTION square nut clean out cap installed for serer-spoke wiyh JC-Super if he could change out to a flush 6in and he said he would | |||
| BLD - BUILDING FINAL | 07/31/2020 | FINAL APPROVED | JBODEN |
| Note: THIS IS A REINSPECTION ADDED ON 7/30/2020 8:04:59 AM Waiting on revision for sump pump in backyard. | |||
| BLD - BUILDING FINAL | 07/30/2020 | CANCELLED BY APPLICANT | JMUNSON |
| Note: Waiting on revision for sump pump in backyard. | |||
| U -UTILITY RESIDENTIAL FINAL | 07/30/2020 | PARTIALLY APPROVED | LFITZGERALD |
| Note: square nut clean out cap installed for serer-spoke wiyh JC-Super if he could change out to a flush 6in and he said he would | |||
| ROW - STORMWATER FINAL | 07/29/2020 | APPROVED | RGROSS |
| ROW - FINAL APRON (AFTER POUR) | 07/29/2020 | APPROVED | RGROSS |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/28/2020 | APPROVED - AS NOTED | RGROSS |
| Note: SEE NOTES ON APPROVED FINAL SURVEY. | |||
| FINAL SURVEY (OFFICE USE ONLY) | 07/28/2020 | APPROVED - AS NOTED | RGROSS |
| Note: DRAINAGE ALONG THE LEFT SIDE PROPERTY LINE ON PAPER SURVEY DOES NOT APPEAR TO HAVE FALL BUT THE FIELD SURVEY INDICATES THAT THE STORM WATER WILL DRAIN. THEREFORE APPROVED AS NOTED. | |||
| U-CROSS CONNECTION | 07/10/2020 | FINAL APPROVED | MBACON |
| ROW- PRE-APRON (PRE-POUR) | 06/05/2020 | APPROVED | RGROSS |
| Note: READY TO POUR AND PLACE PAVERS. RESTRAINS READY. | |||
| ROW- PAVER RESTRAINTS | 06/05/2020 | APPROVED | RGROSS |
| ELECTRIC - EARLY POWER | 02/18/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 2:20 | |||
| INSULATION | 01/07/2020 | APPROVED | JDELBONIS |
| LATH/BRICK/ WATER BARRIER | 01/03/2020 | APPROVED | JDELBONIS |
| ALL ROUGH | 12/27/2019 | APPROVED | FWILLIS |
| ROOF VALLEY & METAL | 12/02/2019 | APPROVED | JDELBONIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/20/2019 | APPROVED | JDELBONIS |
| Note: THIS IS A REINSPECTION | |||
| ELECTRIC-TUG | 11/20/2019 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 11:50 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/19/2019 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 1. SOLIDBLOCKING REQUIRED AT SHEATHING ENDS. (PER MANUFACTURER SPECS ON ENGINEERED SHEATHING) (OR SUPPLY MANUFACTURER SPECS FOR APPLICATION USED) 2. TRUSS BLOCKING REQUIRED WHERE SHEATHING SPANS MORE THAN 24 inches. (PER MANUFACTURER SPECS ON ENGINEERED SHEATHING) (OR SUPPLY MANUFACTURER SPECS FOR APPLICATION USED) 3. CONTINUOUS LOAD PATH… R301,2.1 OVERFRAMING NOT TIED TO STRUCTURAL MEMBERS BENEATH (KNEEWALL AT GARAGE) | |||
| TIE BEAM / LINTEL | 11/07/2019 | APPROVED | MWILLIAMS |
| ELEV CERT-FOUNDATION APPROVAL | 11/04/2019 | APPROVED | JMYERS |
| FOUND SURVEY APPROVED (OFFICE) | 11/04/2019 | APPROVED | JMUNSON |
| MONOLITHIC SLAB | 10/23/2019 | APPROVED | MWILLIAMS |
| PLUMBING 1ST ROUGH UNDERGROUND | 10/18/2019 | APPROVED | JGIBSON |
| GRAVITY SEWER TEST | 10/18/2019 | APPROVED | JGIBSON |
| U - SEWER TIE IN | 10/18/2019 | APPROVED | JGIBSON |
| WATER METER INSTALLATION REQUEST | 10/02/2019 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| PLFM | COMPLETE | 08/05/2020 | 08/05/2020 |
| Note: Released By: JMYERS The Final elevation certificate has been accepted. | |||
| ELEC | COMPLETE | 07/30/2020 | 07/30/2020 |
| Note: Released By: JMUNSON | |||
| PLFM | COMPLETE | 11/04/2019 | 11/04/2019 |
| Note: Released By: JMYERS The Building elevation certificate has been approved. Please provide Final prior to receiving CO. | |||
| SW1 | COMPLETE | 11/04/2019 | 11/04/2019 |
| Note: Released By: JMUNSON | |||
| PLFM | COMPLETE | 09/10/2019 | 09/10/2019 |
| Note: Released By: JMYERS The Construction elevation certificate has been accepted. Please provide Building and Final prior to receiving CO. | |||
| PLFM | HOLD | 09/05/2019 | 09/05/2019 |
| Note: Held By: JMYERS According to City mapping resources, the entirety of this lot resides in a Special Flood Hazard Area. Elevation certificates will be required at 3 stages. Construction Drawings, Foundation, and Final. | |||
| BLD | COMPLETE | 08/30/2019 | 09/08/2019 |
| Note: Released By: MGARRETT | |||
| CUSVC | COMPLETE | 08/30/2019 | 09/05/2019 |
| Note: Released By: AROSCOE | |||
| ELEC | COMPLETE | 08/30/2019 | 08/30/2019 |
| Note: Released By: JMUNSON | |||
| ENGIN1 | COMPLETE | 08/30/2019 | 09/11/2019 |
| Note: Released By: TBAKER | |||
| LOCATE | COMPLETE | 08/30/2019 | 09/06/2019 |
| Note: Released By: CSTONE | |||
| MECH | COMPLETE | 08/30/2019 | 09/08/2019 |
| Note: Released By: MGARRETT | |||
| PLUM | COMPLETE | 08/30/2019 | 09/08/2019 |
| Note: Released By: MGARRETT | |||
| SW1 | COMPLETE | 08/30/2019 | 08/30/2019 |
| Note: Released By: JMUNSON | |||
| UD1 | COMPLETE | 08/30/2019 | 09/09/2019 |
| Note: Released By: AHALL | |||
| ZON | COMPLETE | 08/30/2019 | 09/05/2019 |
| Note: Released By: AMOBLEY |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 07/31/2020 |
| REINSPECTION FEE | ¤40.00 | 07/31/2020 |
| NEW RESIDENTIAL INSPECTIONS | ¤646.00 | 09/11/2019 |
| SITE PLAN 20 | ¤20.00 | 09/11/2019 |
| SURCHARGE FS 533.721 | ¤14.47 | 09/11/2019 |
| SURCHARGE - FS 468.631 | ¤21.71 | 09/11/2019 |
| STORM WATER PERMIT FEES | ¤80.00 | 09/11/2019 |
| 3% TRANS IMPACT FEE CREDIT | (¤89.43) | 09/11/2019 |
| SEWER INSPECTION | ¤25.00 | 09/11/2019 |
| ELECTRIC FEE | ¤253.80 | 09/11/2019 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.70) | 09/11/2019 |
| IMPACT FEE FIRE | ¤223.38 | 09/11/2019 |
| IMPACT FEE PARKS | ¤849.24 | 09/11/2019 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 09/11/2019 |
| IMPACT FEE TRANSPORTATION | ¤2,981.00 | 09/11/2019 |
| MECHANICAL FEE | ¤253.80 | 09/11/2019 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 09/11/2019 |
| PLAN CHECK FEE | ¤129.20 | 09/11/2019 |
| PLUMBING FEE | ¤253.80 | 09/11/2019 |
| METER - DEPOSIT | ¤60.00 | 09/11/2019 |
| WATER-METER | ¤426.95 | 09/11/2019 |
| WATER-METER | ¤354.69 | 09/11/2019 |
| ADMIN FEE | ¤20.00 | 09/11/2019 |
| CONNECTION FEES | ¤25.00 | 09/11/2019 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,196.43 |