I want to search for...

Permit #2019090352

Permit Details

Status: COED

Parcel Id: 07-11-31-7022-00270-0280
CONDITIONED SPACE: 1500 sqft
GARAGE: 380 sqft
OPENED PORCH (WITH ROOF) : 72 sqft
OPENED PORCH (WITH ROOF) : 100 sqft
Total Square Footage: 2052 sqft
Block: 00270
Subdivision: 2217 - SECTION 22-WYNNFIELD
Job Phone: 386-248-0033
Location Address: 117 WESTROBIN LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/30/2019
NOC: RECORDED
Applicant name: JEFFREY T WISE
Owner: 3 S HOUSING LLC

Address

226 N NOVA ROAD #318

ORMOND BEACH, FL 32174

Lot: 0280
Contracted Stated Job Value: ¤187,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

WISE BUILDERS LLC
Status Location Address State License Number Phone
ACTIVE

120 CARSWELL AVE

HOLLY HILL, FL 32117

CGC055237 (Exp: 08/31/2026) 386-248-0033

Sub Contractors

NORMAN J VAN HORNE
Status Location Address State License Number Phone
CANCEL

PO BOX 251228

HOLLY HILL, FL 32117

CFC032605 (Exp: 08/31/2022) (386)258-0608
JAMES R DOOLEY
Status Location Address State License Number Phone Fax
ACTIVE

1550 GARDEN AVENUE

HOLLY HILL, FL 32117

EC13005817 (Exp: 08/31/2026) 386-672-4433 386-672-9793
KEVIN HENRY BEHRENS
Status Location Address State License Number Phone Fax
INACTIVE

1200 SOUTH NOVA ROAD

DAYTONA BEACH, FL 32114

CAC054733 (Exp: 08/31/2026) (386)761-7751 (386) 258-0058
JEFFREY T WISE
Status Location Address State License Number Phone Fax
ACTIVE

120 CARSWELL AVE

HOLLY HILL, FL 32117

CCC049377 (Exp: 08/31/2026) 386-248-0033 386-248-0033

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 07/01/2020 FINAL APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION need termite final sticker and water hammer at sink for dishwasher line
BLD - BUILDING FINAL 06/29/2020 Disapproved - NO FEE JCOLASANTI
Note: need termite final sticker and water hammer at sink for dishwasher line
U -UTILITY RESIDENTIAL FINAL 06/29/2020 APPROVED - AS NOTED LFITZGERALD
Note: spoke with Glen-Wise Construction- regarding using flush mount sewer clean out caps versus square top nut)( which is perfered by the city and would arrnge to replace this one and have flush mount caps in use for the future.
ROW - STORMWATER FINAL 06/26/2020 APPROVED RGROSS
ROW - FINAL APRON (AFTER POUR) 06/26/2020 APPROVED RGROSS
ROW FIELD SURVEY /GRADING CERTIFICATION 06/25/2020 APPROVED - AS NOTED RGROSS
Note: SEE NOTES ON FINAL SURVEY APPROVED INSPECTION.
FINAL SURVEY (OFFICE USE ONLY) 06/25/2020 APPROVED - AS NOTED RGROSS
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION DRAINAGE ALL ALONG THE RIGHT SIDE PROPERTY LINE CANNOT FLOW ONTO THE ADJACENT LOT. DRAINAGE CONVEYANCE ALONG THE LEFT SIDE MUST FALL 1/10TH PER 20 FT. 6/19/20 - SURVEY DOES NOT SHOW A CONSISTAN ONE 10TH FALL FROM REAR TO FRONT ON BOTH SIDES PER BUILDER MET WITH CONRAD AND ADJUSTED THE DRIANAGE PATTERN ON THE RIGHT SIDE DUE TO AN EXISTING TREE.
FINAL SURVEY (OFFICE USE ONLY) 06/19/2020 Disapproved - NO FEE RGROSS
Note: THIS IS A REINSPECTION DRAINAGE ALL ALONG THE RIGHT SIDE PROPERTY LINE CANNOT FLOW ONTO THE ADJACENT LOT. DRAINAGE CONVEYANCE ALONG THE LEFT SIDE MUST FALL 1/10TH PER 20 FT. 6/19/20 - SURVEY DOES NOT SHOW A CONSISTAN ONE 10TH FALL FROM REAR TO FRONT ON BOTH SIDES
FINAL SURVEY (OFFICE USE ONLY) 06/05/2020 Disapproved - NO FEE RGROSS
Note: DRAINAGE ALL ALONG THE RIGHT SIDE PROPERTY LINE CANNOT FLOW ONTO THE ADJACENT LOT. DRAINAGE CONVEYANCE ALONG THE LEFT SIDE MUST FALL 1/10TH PER 20 FT.
ROW FIELD SURVEY /GRADING CERTIFICATION 06/05/2020 CANCELLED BY INSPECTOR RGROSS
Note: FINAL SURVEY MUST BE APPROVED FIRST.
ELECTRIC - EARLY POWER 02/10/2020 APPROVED - AS NOTED RMARTIN
Note: EMAILED FPL RELEASED POWER 12:00
GRAVITY SEWER TEST 01/30/2020 APPROVED JGIBSON
U - SEWER TIE IN 01/30/2020 APPROVED JGIBSON
ROW- PRE-APRON (PRE-POUR) 01/28/2020 APPROVED - AS NOTED MMAJEWSKI
Note: THIS IS A REINSPECTION. IT IS THE BUILDER’S RESPONSIBILITY: TO RECHECK ELEVATIONS AND PIPE SIZE, TO INSURE THAT AN OBSTRUCTION DOES NOT EXIST UPSTREAM AND OR DOWNSTREAM, THAT THE CULVERT PIPE IS SET TO AND OR FOLLOWS THE SWALE PLAN, FORM THE DRIVEWAY TO THE APPROVEDSITE PLAN AND FOLLOW THE APPROVED DRIVEWAY DETAIL SHEET PROVIDED BY THE CITY OF PALM COAST. PRIOR TO PLACEMENT OF CONCRETE
ROW- PRE-APRON (PRE-POUR) 01/27/2020 Disapproved - NO FEE MMAJEWSKI
Note: APRON FLARES NEED TO BE 36 INCHES MUST BE 5 INCHES THICK MINIMUM FROM RIGHT OF WAY TO EDGE OF PAVEMENT AND 4 INCHES THICK THROUGHOUT THE REST OF DRIVEWAY
INSULATION 01/03/2020 APPROVED JCOLASANTI
LATH/BRICK/ WATER BARRIER 01/02/2020 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
LATH/BRICK/ WATER BARRIER 12/31/2019 Disapproved - NO FEE JCOLASANTI
Note: WEATHER RESISTANT BARRIER (TYVEC/etc.) AT WOOD TO BLOCK INTERSECTION PER MANUFACTURER SPECS AND ASTM SPECS FBC 703.1.1
ALL ROUGH 12/27/2019 APPROVED - AS NOTED JCOLASANTI
Note: need to clamp service mast....nail plate electrical and dryer vent...must seal exhaust vents at roof with mastic....frame panel box and teminate lines....smoke detectors need to be 3' from fan blades
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/19/2019 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
ROOF VALLEY & METAL 12/19/2019 APPROVED JCOLASANTI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/12/2019 PARTIALLY APPROVED WMILLER
Note: sheathing fasteners ok need collar ties for valley sets per detail
TIE BEAM / LINTEL 11/26/2019 APPROVED FWILLIS
Note: THIS IS A REINSPECTION
TIE BEAM / LINTEL 11/25/2019 CANCELLED BY APPLICANT WMILLER
FOUND SURVEY APPROVED (OFFICE) 11/20/2019 APPROVED CTROHA
MONOLITHIC SLAB 11/13/2019 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB 11/12/2019 Disapproved -FEE REQUIRED WMILLER
Note: footing F3 is not formed for drop per detail (inside Garage) CLEARANCE FROM EARTH AND WEATHER R606.13.5 REINFORCING BARS USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER, INCLUDUNG GROUT, OF NOT LESS THAN 2 inches FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER AND 1.5 inches NOT EXPOSED TO EARTH OR WEATHER (all marked on plans)
ELECTRIC UNDERGROUND 11/12/2019 APPROVED - AS NOTED RMARTIN
Note: UFER GROUND GOOD
PLUMBING 1ST ROUGH UNDERGROUND 11/07/2019 APPROVED JDELBONIS
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 11/06/2019 Disapproved -FEE REQUIRED WMILLER
Note: DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL (need the APPROVED paperwork on site at time of final) (PAPERWORK WAS NOT THE APPROVED PAPERWORK) 6TH EDITION)
WATER METER INSTALLATION REQUEST 11/04/2019 APPROVED CSTONE
ELECTRIC TEMP POLE 10/22/2019 APPROVED - AS NOTED RMARTIN

Review History

Department Status Date In Date Out
SW1 COMPLETE 03/02/2020 03/06/2020
Note: Released By: CTROHA
SW1 HOLD 02/18/2020 02/24/2020
Note: Held By: CTROHA Applicant can not drain all stormwater to the rear may drain the rear part of the yard and provide a clear site plan dipicting drainage conveyance Applicant needs to show proposed elevations on a 20' grid also show proposed drainage elevations. show existing elevations the revised site plan that was submitted on 10/1/2019 is acceptable
ZON COMPLETE 02/18/2020 02/19/2020
Note: Released By: AMOBLEY
UD1 COMPLETE 02/18/2020 02/20/2020
Note: Released By: AHALL
ENGIN1 COMPLETE 02/10/2020 02/11/2020
Note: Released By: TBAKER
UD1 COMPLETE 02/10/2020 02/11/2020
Note: Released By: AHALL
ZON COMPLETE 02/10/2020 02/11/2020
Note: Released By: ELENS
SW1 HOLD 02/10/2020 02/13/2020
Note: Held By: CTROHA Applicant can not drain all stormwater to the rear may drain the rear part of the yard and provide a clear site plan dipicting drainage conveyance Applicant needs to show proposed elevations on a 20' grid also show proposed drainage elevations.
ENGIN1 COMPLETE 11/19/2019 11/20/2019
Note: Released By: CTROHA
ZON COMPLETE 09/23/2019 09/24/2019
Note: Released By: AMOBLEY
SWALE COMPLETE 09/16/2019 10/04/2019
Note: Released By: TBAKER
BLD COMPLETE 09/12/2019 09/19/2019
Note: Released By: MGARRETT
CUSVC COMPLETE 09/12/2019 09/13/2019
Note: Released By: HHAND
ELEC COMPLETE 09/12/2019 09/16/2019
Note: Released By: JMUNSON
ENGIN1 COMPLETE 09/12/2019 09/16/2019
Note: Released By: TBAKER
LOCATE COMPLETE 09/12/2019 09/13/2019
Note: Released By: CSTONE
MECH COMPLETE 09/12/2019 09/19/2019
Note: Released By: MGARRETT
PLUM COMPLETE 09/12/2019 09/19/2019
Note: Released By: MGARRETT
SW1 COMPLETE 09/12/2019 09/13/2019
Note: Released By: JMUNSON
UD1 COMPLETE 09/12/2019 09/17/2019
Note: Released By: AHALL
ZON HOLD 09/12/2019 09/13/2019
Note: Held By: AMOBLEY Plan calculations on floor plan page must have the front and rear entry patios included Please show on site plan driveway material being used Landscape plan must include required number of foundation plantings, trees, sod type and if irrigation will be installed. Specific types of trees and shrubs must be listed. Residential requirements below... At least one (1) tree shall be provided for each 2,500 square feet of lot area Residential homes shall provide foundation plantings consisting of sixteen (16) shrubs. On interior lots, eight (8) shrubs shall be planted in front of the home, and four (4) shrubs planted on each side of the home. AC Pad must be screened with at least two 7 gallon shrubs

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 11/25/2019
REINSPECTION FEE ¤40.00 11/06/2019
NEW RESIDENTIAL INSPECTIONS ¤378.00 09/30/2019
SITE PLAN 20 ¤20.00 09/30/2019
SURCHARGE FS 533.721 ¤9.38 09/30/2019
SURCHARGE - FS 468.631 ¤14.07 09/30/2019
STORM WATER PERMIT FEES ¤80.00 09/30/2019
3% TRANS IMPACT FEE CREDIT (¤48.96) 09/30/2019
SEWER CREDIT (¤1,466.00) 09/30/2019
SEWER INSPECTION ¤25.00 09/30/2019
SEWER CAPITAL FACILITY ¤4,515.25 09/30/2019
WATER CAPITAL FACILITY FEE ¤3,314.84 09/30/2019
METER - DEPOSIT ¤60.00 09/30/2019
WATER- TURN ON ¤25.00 09/30/2019
ADMIN FEE ¤20.00 09/30/2019
CONNECTION FEES ¤985.25 09/30/2019
ELECTRIC FEE ¤173.40 09/30/2019
3% FIRE IMPACT FEE CREDIT (¤6.70) 09/30/2019
IMPACT FEE FIRE ¤223.38 09/30/2019
IMPACT FEE PARKS ¤849.24 09/30/2019
IMPACT FEE SCHOOL ¤3,600.00 09/30/2019
IMPACT FEE TRANSPORTATION ¤1,632.00 09/30/2019
MECHANICAL FEE ¤173.40 09/30/2019
WATER -IRRIGATION INSPECTION ¤25.00 09/30/2019
3% PARKS IMPACT FEE CREDIT (¤25.48) 09/30/2019
PLAN CHECK FEE ¤75.60 09/30/2019
PLUMBING FEE ¤173.40 09/30/2019
Fees Total Due: ¤0.00 Total Paid: ¤14,905.07