Permit #2019090352
Permit Details
Status: COED
| Parcel Id: 07-11-31-7022-00270-0280 |
| CONDITIONED SPACE: 1500 sqft |
| GARAGE: 380 sqft |
| OPENED PORCH (WITH ROOF) : 72 sqft |
| OPENED PORCH (WITH ROOF) : 100 sqft |
| Total Square Footage: 2052 sqft |
| Block: 00270 |
| Subdivision: 2217 - SECTION 22-WYNNFIELD |
| Job Phone: 386-248-0033 |
| Location Address: 117 WESTROBIN LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/30/2019 |
| NOC: RECORDED |
| Applicant name: JEFFREY T WISE |
| Owner: 3 S HOUSING LLC |
|
Address 226 N NOVA ROAD #318 ORMOND BEACH, FL 32174 |
| Lot: 0280 |
| Contracted Stated Job Value: ¤187,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
WISE BUILDERS LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
120 CARSWELL AVE HOLLY HILL, FL 32117 |
CGC055237 (Exp: 08/31/2026) | 386-248-0033 |
Sub Contractors
NORMAN J VAN HORNE
| Status | Location Address | State License Number | Phone |
| CANCEL |
PO BOX 251228 HOLLY HILL, FL 32117 |
CFC032605 (Exp: 08/31/2022) | (386)258-0608 |
JAMES R DOOLEY
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1550 GARDEN AVENUE HOLLY HILL, FL 32117 |
EC13005817 (Exp: 08/31/2026) | 386-672-4433 | 386-672-9793 |
KEVIN HENRY BEHRENS
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1200 SOUTH NOVA ROAD DAYTONA BEACH, FL 32114 |
CAC054733 (Exp: 08/31/2026) | (386)761-7751 | (386) 258-0058 |
JEFFREY T WISE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
120 CARSWELL AVE HOLLY HILL, FL 32117 |
CCC049377 (Exp: 08/31/2026) | 386-248-0033 | 386-248-0033 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 07/01/2020 | FINAL APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION need termite final sticker and water hammer at sink for dishwasher line | |||
| BLD - BUILDING FINAL | 06/29/2020 | Disapproved - NO FEE | JCOLASANTI |
| Note: need termite final sticker and water hammer at sink for dishwasher line | |||
| U -UTILITY RESIDENTIAL FINAL | 06/29/2020 | APPROVED - AS NOTED | LFITZGERALD |
| Note: spoke with Glen-Wise Construction- regarding using flush mount sewer clean out caps versus square top nut)( which is perfered by the city and would arrnge to replace this one and have flush mount caps in use for the future. | |||
| ROW - STORMWATER FINAL | 06/26/2020 | APPROVED | RGROSS |
| ROW - FINAL APRON (AFTER POUR) | 06/26/2020 | APPROVED | RGROSS |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/25/2020 | APPROVED - AS NOTED | RGROSS |
| Note: SEE NOTES ON FINAL SURVEY APPROVED INSPECTION. | |||
| FINAL SURVEY (OFFICE USE ONLY) | 06/25/2020 | APPROVED - AS NOTED | RGROSS |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION DRAINAGE ALL ALONG THE RIGHT SIDE PROPERTY LINE CANNOT FLOW ONTO THE ADJACENT LOT. DRAINAGE CONVEYANCE ALONG THE LEFT SIDE MUST FALL 1/10TH PER 20 FT. 6/19/20 - SURVEY DOES NOT SHOW A CONSISTAN ONE 10TH FALL FROM REAR TO FRONT ON BOTH SIDES PER BUILDER MET WITH CONRAD AND ADJUSTED THE DRIANAGE PATTERN ON THE RIGHT SIDE DUE TO AN EXISTING TREE. | |||
| FINAL SURVEY (OFFICE USE ONLY) | 06/19/2020 | Disapproved - NO FEE | RGROSS |
| Note: THIS IS A REINSPECTION DRAINAGE ALL ALONG THE RIGHT SIDE PROPERTY LINE CANNOT FLOW ONTO THE ADJACENT LOT. DRAINAGE CONVEYANCE ALONG THE LEFT SIDE MUST FALL 1/10TH PER 20 FT. 6/19/20 - SURVEY DOES NOT SHOW A CONSISTAN ONE 10TH FALL FROM REAR TO FRONT ON BOTH SIDES | |||
| FINAL SURVEY (OFFICE USE ONLY) | 06/05/2020 | Disapproved - NO FEE | RGROSS |
| Note: DRAINAGE ALL ALONG THE RIGHT SIDE PROPERTY LINE CANNOT FLOW ONTO THE ADJACENT LOT. DRAINAGE CONVEYANCE ALONG THE LEFT SIDE MUST FALL 1/10TH PER 20 FT. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/05/2020 | CANCELLED BY INSPECTOR | RGROSS |
| Note: FINAL SURVEY MUST BE APPROVED FIRST. | |||
| ELECTRIC - EARLY POWER | 02/10/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 12:00 | |||
| GRAVITY SEWER TEST | 01/30/2020 | APPROVED | JGIBSON |
| U - SEWER TIE IN | 01/30/2020 | APPROVED | JGIBSON |
| ROW- PRE-APRON (PRE-POUR) | 01/28/2020 | APPROVED - AS NOTED | MMAJEWSKI |
| Note: THIS IS A REINSPECTION. IT IS THE BUILDER’S RESPONSIBILITY: TO RECHECK ELEVATIONS AND PIPE SIZE, TO INSURE THAT AN OBSTRUCTION DOES NOT EXIST UPSTREAM AND OR DOWNSTREAM, THAT THE CULVERT PIPE IS SET TO AND OR FOLLOWS THE SWALE PLAN, FORM THE DRIVEWAY TO THE APPROVEDSITE PLAN AND FOLLOW THE APPROVED DRIVEWAY DETAIL SHEET PROVIDED BY THE CITY OF PALM COAST. PRIOR TO PLACEMENT OF CONCRETE | |||
| ROW- PRE-APRON (PRE-POUR) | 01/27/2020 | Disapproved - NO FEE | MMAJEWSKI |
| Note: APRON FLARES NEED TO BE 36 INCHES MUST BE 5 INCHES THICK MINIMUM FROM RIGHT OF WAY TO EDGE OF PAVEMENT AND 4 INCHES THICK THROUGHOUT THE REST OF DRIVEWAY | |||
| INSULATION | 01/03/2020 | APPROVED | JCOLASANTI |
| LATH/BRICK/ WATER BARRIER | 01/02/2020 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 12/31/2019 | Disapproved - NO FEE | JCOLASANTI |
| Note: WEATHER RESISTANT BARRIER (TYVEC/etc.) AT WOOD TO BLOCK INTERSECTION PER MANUFACTURER SPECS AND ASTM SPECS FBC 703.1.1 | |||
| ALL ROUGH | 12/27/2019 | APPROVED - AS NOTED | JCOLASANTI |
| Note: need to clamp service mast....nail plate electrical and dryer vent...must seal exhaust vents at roof with mastic....frame panel box and teminate lines....smoke detectors need to be 3' from fan blades | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/19/2019 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| ROOF VALLEY & METAL | 12/19/2019 | APPROVED | JCOLASANTI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/12/2019 | PARTIALLY APPROVED | WMILLER |
| Note: sheathing fasteners ok need collar ties for valley sets per detail | |||
| TIE BEAM / LINTEL | 11/26/2019 | APPROVED | FWILLIS |
| Note: THIS IS A REINSPECTION | |||
| TIE BEAM / LINTEL | 11/25/2019 | CANCELLED BY APPLICANT | WMILLER |
| FOUND SURVEY APPROVED (OFFICE) | 11/20/2019 | APPROVED | CTROHA |
| MONOLITHIC SLAB | 11/13/2019 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB | 11/12/2019 | Disapproved -FEE REQUIRED | WMILLER |
| Note: footing F3 is not formed for drop per detail (inside Garage) CLEARANCE FROM EARTH AND WEATHER R606.13.5 REINFORCING BARS USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER, INCLUDUNG GROUT, OF NOT LESS THAN 2 inches FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER AND 1.5 inches NOT EXPOSED TO EARTH OR WEATHER (all marked on plans) | |||
| ELECTRIC UNDERGROUND | 11/12/2019 | APPROVED - AS NOTED | RMARTIN |
| Note: UFER GROUND GOOD | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 11/07/2019 | APPROVED | JDELBONIS |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 11/06/2019 | Disapproved -FEE REQUIRED | WMILLER |
| Note: DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL (need the APPROVED paperwork on site at time of final) (PAPERWORK WAS NOT THE APPROVED PAPERWORK) 6TH EDITION) | |||
| WATER METER INSTALLATION REQUEST | 11/04/2019 | APPROVED | CSTONE |
| ELECTRIC TEMP POLE | 10/22/2019 | APPROVED - AS NOTED | RMARTIN |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 03/02/2020 | 03/06/2020 |
| Note: Released By: CTROHA | |||
| SW1 | HOLD | 02/18/2020 | 02/24/2020 |
| Note: Held By: CTROHA Applicant can not drain all stormwater to the rear may drain the rear part of the yard and provide a clear site plan dipicting drainage conveyance Applicant needs to show proposed elevations on a 20' grid also show proposed drainage elevations. show existing elevations the revised site plan that was submitted on 10/1/2019 is acceptable | |||
| ZON | COMPLETE | 02/18/2020 | 02/19/2020 |
| Note: Released By: AMOBLEY | |||
| UD1 | COMPLETE | 02/18/2020 | 02/20/2020 |
| Note: Released By: AHALL | |||
| ENGIN1 | COMPLETE | 02/10/2020 | 02/11/2020 |
| Note: Released By: TBAKER | |||
| UD1 | COMPLETE | 02/10/2020 | 02/11/2020 |
| Note: Released By: AHALL | |||
| ZON | COMPLETE | 02/10/2020 | 02/11/2020 |
| Note: Released By: ELENS | |||
| SW1 | HOLD | 02/10/2020 | 02/13/2020 |
| Note: Held By: CTROHA Applicant can not drain all stormwater to the rear may drain the rear part of the yard and provide a clear site plan dipicting drainage conveyance Applicant needs to show proposed elevations on a 20' grid also show proposed drainage elevations. | |||
| ENGIN1 | COMPLETE | 11/19/2019 | 11/20/2019 |
| Note: Released By: CTROHA | |||
| ZON | COMPLETE | 09/23/2019 | 09/24/2019 |
| Note: Released By: AMOBLEY | |||
| SWALE | COMPLETE | 09/16/2019 | 10/04/2019 |
| Note: Released By: TBAKER | |||
| BLD | COMPLETE | 09/12/2019 | 09/19/2019 |
| Note: Released By: MGARRETT | |||
| CUSVC | COMPLETE | 09/12/2019 | 09/13/2019 |
| Note: Released By: HHAND | |||
| ELEC | COMPLETE | 09/12/2019 | 09/16/2019 |
| Note: Released By: JMUNSON | |||
| ENGIN1 | COMPLETE | 09/12/2019 | 09/16/2019 |
| Note: Released By: TBAKER | |||
| LOCATE | COMPLETE | 09/12/2019 | 09/13/2019 |
| Note: Released By: CSTONE | |||
| MECH | COMPLETE | 09/12/2019 | 09/19/2019 |
| Note: Released By: MGARRETT | |||
| PLUM | COMPLETE | 09/12/2019 | 09/19/2019 |
| Note: Released By: MGARRETT | |||
| SW1 | COMPLETE | 09/12/2019 | 09/13/2019 |
| Note: Released By: JMUNSON | |||
| UD1 | COMPLETE | 09/12/2019 | 09/17/2019 |
| Note: Released By: AHALL | |||
| ZON | HOLD | 09/12/2019 | 09/13/2019 |
| Note: Held By: AMOBLEY Plan calculations on floor plan page must have the front and rear entry patios included Please show on site plan driveway material being used Landscape plan must include required number of foundation plantings, trees, sod type and if irrigation will be installed. Specific types of trees and shrubs must be listed. Residential requirements below... At least one (1) tree shall be provided for each 2,500 square feet of lot area Residential homes shall provide foundation plantings consisting of sixteen (16) shrubs. On interior lots, eight (8) shrubs shall be planted in front of the home, and four (4) shrubs planted on each side of the home. AC Pad must be screened with at least two 7 gallon shrubs |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 11/25/2019 |
| REINSPECTION FEE | ¤40.00 | 11/06/2019 |
| NEW RESIDENTIAL INSPECTIONS | ¤378.00 | 09/30/2019 |
| SITE PLAN 20 | ¤20.00 | 09/30/2019 |
| SURCHARGE FS 533.721 | ¤9.38 | 09/30/2019 |
| SURCHARGE - FS 468.631 | ¤14.07 | 09/30/2019 |
| STORM WATER PERMIT FEES | ¤80.00 | 09/30/2019 |
| 3% TRANS IMPACT FEE CREDIT | (¤48.96) | 09/30/2019 |
| SEWER CREDIT | (¤1,466.00) | 09/30/2019 |
| SEWER INSPECTION | ¤25.00 | 09/30/2019 |
| SEWER CAPITAL FACILITY | ¤4,515.25 | 09/30/2019 |
| WATER CAPITAL FACILITY FEE | ¤3,314.84 | 09/30/2019 |
| METER - DEPOSIT | ¤60.00 | 09/30/2019 |
| WATER- TURN ON | ¤25.00 | 09/30/2019 |
| ADMIN FEE | ¤20.00 | 09/30/2019 |
| CONNECTION FEES | ¤985.25 | 09/30/2019 |
| ELECTRIC FEE | ¤173.40 | 09/30/2019 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.70) | 09/30/2019 |
| IMPACT FEE FIRE | ¤223.38 | 09/30/2019 |
| IMPACT FEE PARKS | ¤849.24 | 09/30/2019 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 09/30/2019 |
| IMPACT FEE TRANSPORTATION | ¤1,632.00 | 09/30/2019 |
| MECHANICAL FEE | ¤173.40 | 09/30/2019 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 09/30/2019 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 09/30/2019 |
| PLAN CHECK FEE | ¤75.60 | 09/30/2019 |
| PLUMBING FEE | ¤173.40 | 09/30/2019 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤14,905.07 |