I want to search for...

Permit #2019090546

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7017-00010-0450
CONDITIONED SPACE: 60 sqft
OPENED PORCH (WITH ROOF) : 336 sqft
Total Square Footage: 396 sqft
Block: 00010
Subdivision: 2129 - SECTION 17-BELLE TERRE
Job Phone: 386-449-9413
Location Address: 119 BOULDER ROCK DR
Type: BA - BUILDING ADDITION
Issue Date: 11/26/2019
NOC: RECORDED
Applicant name: STEVE HARKINS
Owner: ALLEN JOHN E & LINDA L E H&W

Address

119 BOULDER ROCK DR

PALM COAST, FL 32137

Lot: 0450
Contracted Stated Job Value: ¤61,000.00
Job Description: EXTEND MASTER BATHROOM -ADD UPPER BALCONY
Type: CN

Contractor

HARKINS CUSTOM CONSTRUCTION INC.
Status Location Address State License Number Phone
ACTIVE

665 STREET TRAIL

BUNNELL, FL 32110

CBC1253997 (Exp: 08/31/2026) 386-449-9413

Sub Contractors

JERRY F TORDEUR
Status Location Address State License Number Phone Fax
CANCEL

4244 JACKSON ST

Port Orange, FL 32119

CFC033863 (Exp: 08/31/2020) (386) 761-3526 (386)761-0132
GERALD EDWARD MASTERS JR
Status Location Address State License Number Phone
ACTIVE

505 HERBERT STREET

PORT ORANGE, FL 32129

EC13003217 (Exp: 08/31/2026) (386)304-2600

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 07/24/2020 FINAL APPROVED FWILLIS
Note: THIS IS A REINSPECTION Windows very hard to open and close. Heater fan Making grinding noise when turned on. Electrical outlets need covers and installed close to wall. Outlet under sink needs plate to cover opening. Grab Bars not installed according to ADA.
ROW - FINAL INSPECTION 06/22/2020 APPROVED RGROSS
U -UTILITY RESIDENTIAL FINAL 06/22/2020 APPROVED AHALL
BLD - BUILDING FINAL 06/22/2020 Disapproved - NO FEE FWILLIS
Note: Windows very hard to open and close. Heater fan Making grinding noise when turned on. Electrical outlets need covers and installed close to wall. Outlet under sink needs plate to cover opening. Grab Bars not installed according to ADA.
FINAL SURVEY (OFFICE USE ONLY) 06/17/2020 APPROVED RGROSS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/16/2020 APPROVED JCOLASANTI
FOUND SURVEY APPROVED (OFFICE) 05/06/2020 APPROVED TBAKER
INSULATION 05/05/2020 APPROVED FWILLIS
ALL ROUGH 05/04/2020 APPROVED FWILLIS
ROOF VALLEY & METAL 04/03/2020 APPROVED FWILLIS
LATH/BRICK/ WATER BARRIER 04/03/2020 APPROVED FWILLIS
DOWN CELL 03/13/2020 APPROVED FWILLIS
ROOF SHEATHING 03/10/2020 APPROVED JCOLASANTI
MONOLITHIC SLAB 03/10/2020 APPROVED - AS NOTED JCOLASANTI
Note: footing inspection for spa ..revision to permit
TIE BEAM / LINTEL 02/25/2020 APPROVED FWILLIS
MONOLITHIC SLAB 02/20/2020 APPROVED JCOLASANTI
PLUMBING 1ST ROUGH UNDERGROUND 02/19/2020 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 02/18/2020 Disapproved - NO FEE JGIBSON
Note: P-2502.1 EXISTING PLUMBING, P-2502.2 ADDITIONS ALTERATIONS OR REPAIRS,P-3108.2 DRY VENT CONNECTION, 3108.2 HORIZONTAL WET VENT, 3108.2.2VERTICAL WET VENT

Review History

Department Status Date In Date Out
BADMIN COMPLETE 06/18/2020 06/18/2020
Note: Released By: BBEMBRY
ZON COMPLETE 06/15/2020 06/15/2020
Note: Released By: ELENS
BADMIN HOLD 06/15/2020 06/15/2020
Note: Held By: JMONTARULI I can't put the Final Survey through yet, because they have an outstanding with a lower priority inspection to do first. I sent them an email to let them know
ENGIN1 COMPLETE 05/06/2020 05/07/2020
Note: Released By: TBAKER
ZON HOLD 05/06/2020 05/06/2020
Note: Held By: ELENS The Foundation Survey does not appear to match the approved site plan - location and dimension of proposed bathroom and deck extension and setbacks. Please provide a revised site plan for approval.
BLD COMPLETE 03/02/2020 03/06/2020
Note: Released By: PBUCKLEY
BLD HOLD 02/03/2020 02/11/2020
Note: Held By: PBUCKLEY 1. Provide details signed and sealed by a Florida engineer for the CMU spa enclosure and foundation including all re-enforcing steel, CMU type, grout, etc. 2. Provide complete framing details for deck framing mounted on CMU enclosure walls and extending around spa. Include spans and on-center spacing of joists. Include beam type and details. Include column locations, type and connection details. Include attachment details at CMU wall, support details at ends of deck at spa. Include details for removable section. Include details for all connectors, wood anchors types. Provide design loads (minimum 40 psf live load / 10 psf dead load. Provide framing material details. If wood, provide wood species and grade, indicate preservative treatment type. 3. Provide complete manufacturer's specifications for spa indicating conformance with ANSI/APSP/ICC 6 - 13 and ANSI/APSP/ICC 7 - 13 PER FBCR - Section R4501.6.1. 4. Provide complete spa barrier details in accordance with FBCR Section R4501.17. Provide details conforming with Section R4501.17.1.1 through R4501.17.1.14 including barrier or water alarm details. Provide manufacturer spec sheets for alarms indicating they meet applicable UL2017 or ASTM F2208 standards. If locking cover is to be used on spa in lieu of barrier, provide manufacturer's spec sheet indicating it is a lockable cover and conforms to ASTM F1346
ELEC COMPLETE 02/03/2020 02/04/2020
Note: Released By: JMUNSON
ZON COMPLETE 02/03/2020 02/04/2020
Note: Released By: ELENS
ELEC COMPLETE 11/12/2019 11/14/2019
Note: Released By: JMUNSON
ZON COMPLETE 11/12/2019 11/12/2019
Note: Released By: AMOBLEY
MECH COMPLETE 11/12/2019 11/13/2019
Note: Released By: CPISCITELLI
PLUM COMPLETE 11/12/2019 11/25/2019
Note: Released By: PBUCKLEY
BLD COMPLETE 11/12/2019 11/25/2019
Note: Released By: PBUCKLEY
BLD HOLD 09/17/2019 09/22/2019
Note: Held By: MGARRETT Please provide structural details for the proosed deck: column sizes, anchoring details, columpad demensions. Provide structural details for the proposed CMU wall: footing details, bond beam interconnection to existing, wall to roof anchoring. Provide roof construction details Provide interior framing details
ELEC HOLD 09/17/2019 09/18/2019
Note: Held By: JMUNSON Give scope of work for electrical
MECH HOLD 09/17/2019 09/22/2019
Note: Held By: MGARRETT Please provide mechnical work scope details
PLUM HOLD 09/17/2019 09/22/2019
Note: Held By: MGARRETT Provide plumbing details for the proposed bathroom addition
SW1 COMPLETE 09/17/2019 09/18/2019
Note: Released By: JMUNSON
ZON HOLD 09/17/2019 09/18/2019
Note: Held By: ELENS Please indicate that finished material and color will match the existing house.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN FEE ¤20.00 11/26/2019
ELECTRIC FEE ¤96.60 11/26/2019
MECHANICAL FEE ¤96.60 11/26/2019
PLAN CHECK FEE ¤40.00 11/26/2019
PLUMBING FEE ¤96.60 11/26/2019
REMODEL/ADDITION/ACCES INSPECT ¤40.00 11/26/2019
SITE PLAN 20 ¤20.00 11/26/2019
SURCHARGE FS 533.721 ¤3.70 11/26/2019
SURCHARGE - FS 468.631 ¤5.55 11/26/2019
STORM WATER PERMIT FEES ¤80.00 11/26/2019
Fees Total Due: ¤0.00 Total Paid: ¤499.05