Permit #2019100732
Permit Details
Status: COED
| Parcel Id: 44-11-31-0000-01010-0030 |
| Total Square Footage: 2992 sqft |
| Block: 01010 |
| Subdivision: - |
| Job Phone: 386-313-6950 |
| Location Address: 360 PALM COAST PKWY NE |
| Type: BC - BUILDING COMMERCIAL |
| Issue Date: 11/09/2019 |
| NOC: RECORDED |
| Applicant name: MARK ANTHONY LANGELLO |
| Owner: ANCHOR REAL ESTATE HOLDINGS LLC |
|
Address 160 COSTA BLANCA RD ST AUGUSTINE, FL 32095 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤295,000.00 |
| Job Description: COASTAL REHAB |
| Type: CN |
Contractor
M & M DEVELOPMENT & CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone |
| CANCEL |
2323 N. STATE ST BUNNELL, FL 32110 |
RG291103911 (Exp: 08/31/2023) | 386-313-6950 |
Sub Contractors
ROBERT CARLTON LITTLE
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3050 EAST MOODY BLVD BUNNELL, FL 32110 |
EC13003740 (Exp: 08/31/2026) | 386-931-1708 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
JOHN ROBERT BLEVINS JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
17 PORWYN LANE PALM COAST, FL 32164 |
CAC1816125 (Exp: 08/31/2026) | 386-585-8283 | 386-263-2096 |
GLENN JAMES CANFIELD
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1519 RIDGEWOOD AVE HOLLY HILL, FL 32117 |
CGC1510220 (Exp: 08/31/2022) | 386-257-6199 | 386-257-0556 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC FINAL | 06/29/2020 | APPROVED | RMARTIN |
| Note: THIS IS A REINSPECTION NEED GFCI PROTECTION IN SMALL REST ROOM ON OUTLET, NEC 210.8, NEED 2GANG PLATE INSTALLED SAFED OFF NEED REVISION ON ADDED ELECTRIC AS PER PREVIOUS NOTES ON INSPECTION ALL ITEMS ARE DONE 6/29 | |||
| BUILDING FINAL | 06/29/2020 | FINAL APPROVED | JBODEN |
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | 06/29/2020 | FINAL APPROVED | JBODEN |
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | 06/26/2020 | Disapproved - NO FEE | JBODEN |
| ELECTRIC FINAL | 06/26/2020 | Disapproved - NO FEE | RMARTIN |
| Note: NEED GFCI PROTECTION IN SMALL REST ROOM ON OUTLET, NEC 210.8, NEED 2GANG PLATE INSTALLED SAFED OFF NEED REVISION ON ADDED ELECTRIC AS PER PREVIOUS NOTES ON INSPECTION | |||
| PLUMBING FINAL | 06/26/2020 | APPROVED | JGIBSON |
| HVAC FINAL | 06/26/2020 | FINAL APPROVED | CPISCITELLI |
| BUILDING FINAL | 06/26/2020 | Disapproved - NO FEE | JBODEN |
| U - UTILITY COMMERCIAL FINAL | 06/26/2020 | APPROVED | LFITZGERALD |
| EXTERIOR ARCHITECTURAL FEATURES | 06/22/2020 | APPROVED | BDAWSON |
| Note: THIS IS A REINSPECTION ADDED ON 6/18/2020 1:27:33 PM - Finalize all details on exterior prior to calling in reinspection. Door trim Door painting Complete decorative brackets above doors Signage on building | |||
| U - SEWER TIE IN | 06/19/2020 | APPROVED - AS NOTED | JGIBSON |
| Note: THIS IS A REINSPECTION FINAL CONNECTION WAS MADE | |||
| GRAVITY SEWER | 06/19/2020 | APPROVED | JGIBSON |
| FOUNDATION SURVEY - OFFICE USE ONLY | 06/19/2020 | APPROVED | PBUCKLEY |
| EXTERIOR ARCHITECTURAL FEATURES | 06/18/2020 | Disapproved - NO FEE | BDAWSON |
| Note: - Finalize all details on exterior prior to calling in reinspection. Door trim Door painting Complete decorative brackets above doors Signage on building | |||
| ELECTRIC - EARLY POWER | 06/08/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 2:30 | |||
| ABOVE CEILING | 06/03/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: NO DROP CEILING, ALL M.E.P LOOKED AT HARD CEILINGS ON ROUGH | |||
| INSULATION | 04/30/2020 | APPROVED | JDELBONIS |
| HVAC ROUGH | 04/28/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: CHRIS WENT AND DID THE INSPECTION, PRIOR TO HIS DENTIST APPT. HE SIGNED THE PLACARD | |||
| HVAC ROUGH | 04/24/2020 | CANCELLED BY APPLICANT | CPISCITELLI |
| Note: THIS IS A REINSPECTION need to inspect fresh air and bathfan venting. also need to see balancing dampers on return trip | |||
| ROOF VALLEY & METAL | 04/24/2020 | APPROVED | JDELBONIS |
| FRAMING | 04/24/2020 | APPROVED | JDELBONIS |
| PLUMBING 2ND ROUGH | 04/22/2020 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION NEED 5' HEAD TEST WATER PRESSURE GOOD | |||
| PLUMBING 2ND ROUGH | 04/21/2020 | CANCELLED BY APPLICANT | WEB |
| ELECTRIC 2ND ROUGH | 04/21/2020 | APPROVED | RMARTIN |
| ELECTRIC 2ND ROUGH | 04/21/2020 | CANCELLED BY APPLICANT | WEB |
| FRAMING | 04/21/2020 | CANCELLED BY APPLICANT | WEB |
| FRAMING | 04/20/2020 | APPROVED - AS NOTED | JDELBONIS |
| Note: trusses need b2by 4s added studs and top plate need repair straps doors need to be screwed as per specs | |||
| ELECTRIC 2ND ROUGH | 04/20/2020 | PARTIALLY APPROVED | RMARTIN |
| Note: F/F IN REST ROOMS CHECK MISC. NAIL PLATES | |||
| PLUMBING 2ND ROUGH | 04/20/2020 | PARTIALLY APPROVED | JGIBSON |
| Note: NEED 5' HEAD TEST WATER PRESSURE GOOD | |||
| HVAC ROUGH | 04/20/2020 | PARTIALLY APPROVED | CPISCITELLI |
| Note: need to inspect fresh air and bathfan venting. also need to see balancing dampers on return trip | |||
| STOREFRONT | 04/14/2020 | APPROVED - AS NOTED | JDELBONIS |
| Note: windows ok to install top of frame on doubble window nere side door needs sealent doors frames need to be screwed in acording to specifications in papper work | |||
| LATH/BRICK/WATER BARRIER | 03/25/2020 | APPROVED | JDELBONIS |
| ROOF SHEATHING / BRACE / TIE DOWN | 03/12/2020 | APPROVED | JDELBONIS |
| LINTEL | 02/20/2020 | APPROVED - AS NOTED | FWILLIS |
| Note: Lintels being used are Lotts and Pro-Crete. Approved Plans show Cast Crete as being the Lintels used. Need clarification showing its okay to use Lintels other than Cast Crete. Verify before or at next Inspection. | |||
| MONOLITHIC SLAB | 02/12/2020 | APPROVED | JDELBONIS |
| FOOTER | 02/12/2020 | APPROVED | JDELBONIS |
| U - SEWER TIE IN | 02/12/2020 | PARTIALLY APPROVED | JGIBSON |
| Note: THIS WAS FOR THE TIE IN TO SEWER MAIN FROM SITE CONYTRACTOR AND RAN UP TO WITH-IN 5' OF BUILDING MAIN DRAIN | |||
| PLUMBING 1ST ROUGH | 02/10/2020 | APPROVED - AS NOTED | JGIBSON |
| Note: NEED STAMP PLANS BY NEXT INSPECTION | |||
| ELECTRIC 1ST ROUGH | 02/10/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: NEED TO HAVE CITY APPROVED STAMPED SET OF PLANS ON SITE |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 06/26/2020 | 06/29/2020 |
| Note: Released By: JMUNSON | |||
| BLD | COMPLETE | 06/08/2020 | 06/12/2020 |
| Note: Released By: FREODICA | |||
| BLD | COMPLETE | 03/11/2020 | 03/25/2020 |
| Note: Released By: FREODICA Revision: Changed lintels from cast-crete to Lott's concrete FL 17867.1 and Pro-crete precast FL 23932. | |||
| BLD | HOLD | 02/24/2020 | 03/09/2020 |
| Note: Held By: FREODICA Revision: lintel subtitute. Provide Florida product approval Number for Lott's and Procrete lintels as substitute from Cast- Crete per FS 553.842. FReodica-386-986-4734. | |||
| MECH | COMPLETE | 01/30/2020 | 01/31/2020 |
| Note: Released By: CPISCITELLI | |||
| MECH | HOLD | 12/20/2019 | 12/23/2019 |
| Note: Held By: CPISCITELLI Unable to read layout. Not dark enough | |||
| MECH | COMPLETE | 11/03/2019 | 11/05/2019 |
| Note: Released By: PBUCKLEY | |||
| BLD | COMPLETE | 11/03/2019 | 11/06/2019 |
| Note: Released By: PBUCKLEY | |||
| PLUM | COMPLETE | 11/03/2019 | 11/05/2019 |
| Note: Released By: PBUCKLEY | |||
| ARCHR | COMPLETE | 10/17/2019 | 10/29/2019 |
| Note: Released By: BDAWSON | |||
| BLD | COMPLETE | 10/17/2019 | 10/28/2019 |
| Note: Released By: PBUCKLEY Held By: PBUCKLEY Please see plan correction notes on Plan Sheet A1.1. Corrections necessary to Plan Sheet A1.1 and A4.0. Please contact Patrick Buckley at 386-986-3786 with questions. | |||
| DSD | COMPLETE | 10/17/2019 | 10/23/2019 |
| Note: Released By: DRAMIREZ | |||
| ELEC | COMPLETE | 10/17/2019 | 10/28/2019 |
| Note: Released By: JMUNSON | |||
| FI1 | COMPLETE | 10/17/2019 | 10/31/2019 |
| Note: Released By: WMILLER | |||
| MECH | HOLD | 10/17/2019 | 10/28/2019 |
| Note: Held By: CPISCITELLI Provide mechanical drawings, duct drawings, and equipment specs | |||
| PLUM | HOLD | 10/17/2019 | 10/28/2019 |
| Note: Held By: PBUCKLEY Please provide plumbing isometric plan (sometimes referred to as a plumbing riser diagram) for drain, waste, vent system and water piping system. | |||
| UD1 | COMPLETE | 10/17/2019 | 10/23/2019 |
| Note: Released By: CJOHNSON |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REVISION | ¤40.00 | 06/22/2020 |
| SITE PLAN 20 | ¤20.00 | 11/09/2019 |
| SURCHARGE FS 533.721 | ¤24.14 | 11/09/2019 |
| SURCHARGE - FS 468.631 | ¤36.20 | 11/09/2019 |
| 3% TRANS IMPACT FEE CREDIT | (¤323.85) | 11/09/2019 |
| ADMIN COMMERCIAL | ¤60.00 | 11/09/2019 |
| ELECTRIC FEE | ¤237.00 | 11/09/2019 |
| 3% FIRE IMPACT FEE CREDIT | (¤25.42) | 11/09/2019 |
| IMPACT FEE FIRE | ¤815.62 | 11/09/2019 |
| IMPACT FEE FIRE | ¤31.72 | 11/09/2019 |
| IMPACT FEE TRANSPORTATION | ¤404.10 | 11/09/2019 |
| IMPACT FEE TRANSPORTATION | ¤10,391.04 | 11/09/2019 |
| MECHANICAL FEE | ¤237.00 | 11/09/2019 |
| PERMIT FEE | ¤1,622.50 | 11/09/2019 |
| PLAN CHECK FEE | ¤339.25 | 11/09/2019 |
| PLUMBING FEE | ¤237.00 | 11/09/2019 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤14,146.30 |