I want to search for...
Permit #2019100869
Permit Details
Status: COED
| Parcel Id: 07-11-31-7014-00030-0120 |
| CONDITIONED SPACE: 2576 sqft |
| GARAGE: 689 sqft |
| OPENED PORCH (WITH ROOF) : 441 sqft |
| Total Square Footage: 3706 sqft |
| Block: 00030 |
| Subdivision: 2202 - SECTION 14-COUNTRY CLUB COVE |
| Job Phone: 386-445-7945 |
| Location Address: 24 CENTRAL PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/16/2019 |
| NOC: RECORDED |
| Applicant name: CHRISTOPHER DANIEL FULTON |
| Owner: FULTON CHRISTOPHER & CAROLINE FULTON H&W |
|
Address 15 RIVERVIEW BEND N #213 PALM COAST, FL 32137 |
| Lot: 0120 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
RYSKCON CONSTRUCTION INC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
2 MARKET PLACE PALM COAST, FL 32137 |
UNIT D PALM COAST, FL 32137 |
CRC1332537 (Exp: 08/31/2026) | 386-445-7945 |
Sub Contractors
JOHN EDWARD GAMBONE
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
15 HARGROVE LN PALM COAST, FL 32137 |
1G PALM COAST, FL 32137 |
EC13006037 (Exp: 08/31/2026) | 386-586-9144 |
JOHN ROBERT BLEVINS JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
17 PORWYN LANE PALM COAST, FL 32164 |
CAC1816125 (Exp: 08/31/2026) | 386-585-8283 | 386-263-2096 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
CHRISTOPHER DANIEL FULTON
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
2 MARKET PLACE PALM COAST, FL 32137 |
UNIT D PALM COAST, FL 32137 |
CCC1331939 (Exp: 08/31/2026) | 386-445-7945 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 03/05/2021 | FINAL APPROVED | WMILLER |
| U -UTILITY RESIDENTIAL FINAL | 03/02/2021 | FINAL APPROVED | DHANEY |
| ROW - STORMWATER FINAL | 02/26/2021 | APPROVED - AS NOTED | KRUTH |
| Note: THIS IS A REINSPECTION Final Survey needs approved before this one can be. corrections made | |||
| ROW - FINAL APRON (AFTER POUR) | 02/26/2021 | APPROVED - AS NOTED | KRUTH |
| Note: THIS IS A REINSPECTION Final Survey needs approved before this one. corrections made | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 02/26/2021 | APPROVED | KRUTH |
| ROW- PRE-APRON (PRE-POUR) | 02/26/2021 | APPROVED | KRUTH |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION. APPROVED FOR THE APRON POUR ONLY. PAVER DRIVEWAY STILL NEED UPPER RESTRAINTS DUG AND APPROVED. corrections made | |||
| ROW- PAVER RESTRAINTS | 02/26/2021 | APPROVED | KRUTH |
| FINAL SURVEY (OFFICE USE ONLY) | 02/26/2021 | APPROVED | KRUTH |
| ROW - FINAL APRON (AFTER POUR) | 02/19/2021 | Disapproved - NO FEE | RGROSS |
| Note: NOTE: CULVERT WAS ELIMINATED BY INSPECTOR DURING CONSTRUCTION DUE TO THE EXTREME APRON SLOPE THAT WOULD EXIST TO ACHIEVE CONCRETE THICKNESS REQUIRED. Final Survey needs approved before this one. | |||
| ROW - STORMWATER FINAL | 02/19/2021 | Disapproved - NO FEE | RGROSS |
| Note: Final Survey needs approved before this one can be. NOTE: On site with builder and homeowner. Bare earth by the Canal just needs to be stablized before the Final | |||
| ROW - STORMWATER FINAL | 02/18/2021 | CANCELLED BY APPLICANT | WEB |
| ROW - FINAL APRON (AFTER POUR) | 02/18/2021 | CANCELLED BY APPLICANT | WEB |
| ROW- PRE-APRON (PRE-POUR) | 01/21/2021 | PARTIALLY APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION. APPROVED FOR THE APRON POUR ONLY. PAVER DRIVEWAY STILL NEED UPPER RESTRAINTS DUG AND APPROVED. | |||
| ELECTRIC - EARLY POWER | 01/14/2021 | APPROVED - AS NOTED | RMARTIN |
| Note: THIS IS A REINSPECTION 1/14/21 EMAILED FPL RELEASED POWER 1:30 | |||
| GRAVITY SEWER TEST | 11/02/2020 | APPROVED | JGIBSON |
| U - SEWER TIE IN | 11/02/2020 | APPROVED | JGIBSON |
| ELECTRIC-TUG | 10/26/2020 | APPROVED - AS NOTED | JMUNSON |
| Note: Emailed FPL at 9:38 am | |||
| INSULATION | 10/07/2020 | APPROVED | TSTAUFFACHER |
| INSULATION | 10/06/2020 | CANCELLED BY APPLICANT | WEB |
| ALL ROUGH | 09/25/2020 | APPROVED - AS NOTED | TSTAUFFACHER |
| Note: Get termite treat cert for floor repair in hall prior to filling hole Add protection plates in back left room at floor level Need truss repair // engineer approval on trusses above utility room that are resting on unsupported 2x8 material. the house will be spray foamed and will not affect the areas described above. TS | |||
| WINDOW NAILING | 09/21/2020 | CANCELLED BY APPLICANT | WEB |
| LATH/BRICK/ WATER BARRIER | 09/21/2020 | APPROVED | WMILLER |
| ALL ROUGH | 09/16/2020 | CANCELLED BY APPLICANT | WEB |
| ALL ROUGH | 09/01/2020 | CANCELLED BY APPLICANT | WEB |
| ALL ROUGH | 08/31/2020 | CANCELLED BY APPLICANT | WEB |
| ROOF VALLEY & METAL | 08/28/2020 | APPROVED | FWILLIS |
| PROJECT STATUS (OFFICE USE) | 08/25/2020 | APPROVED - AS NOTED | CTROHA |
| Note: I then spoke with the builder who has proposed a drainage plan that will correct 90% of the problem. In the mean time the builder is pushing water onto 22 property and has agreed to put in a silt fence to direct the water to the front swale or hold water on his property until his final grade can be done. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/02/2020 | APPROVED - AS NOTED | MMESSER |
| Note: Need masonry screws for wood to block connector straps | |||
| TIE BEAM / LINTEL | 05/22/2020 | APPROVED | JDELBONIS |
| FOUND SURVEY APPROVED (OFFICE) | 05/21/2020 | APPROVED | TBAKER |
| ELEV CERT-FOUNDATION APPROVAL | 05/19/2020 | APPROVED | JMYERS |
| MONOLITHIC SLAB | 04/28/2020 | APPROVED | JDELBONIS |
| PLUMBING 1ST ROUGH UNDERGROUND | 04/17/2020 | APPROVED | JGIBSON |
| STEM WALL FOUNDATION | 03/31/2020 | APPROVED | JDELBONIS |
| FOOTER | 02/28/2020 | APPROVED | JDELBONIS |
| Note: THIS IS A REINSPECTION | |||
| FOOTER | 02/27/2020 | Disapproved -FEE REQUIRED | JDELBONIS |
| Note: NO BLUEPRINT DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPE BY THE BUILDING OFFICIAL (need the APPROVED AHRI on site at time of final) (SAME FOR 6TH EDITION) COMPACTION AND TERMITE TREATMENT NOTIFICATION IN BOX | |||
| ROW- PRE-APRON (PRE-POUR) | 02/27/2020 | CANCELLED BY APPLICANT | CPISCITELLI |
| Note: Contractor called wrong inspection | |||
| ELECTRIC TEMP POLE | 01/22/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 1:30 | |||
| ELECTRIC - EARLY POWER | 01/21/2020 | CANCELLED BY APPLICANT | WEB |
| ELECTRIC - EARLY POWER | 01/21/2020 | Disapproved - NO FEE | RMARTIN |
| Note: WRONG INSPECTION CALLED IN NEED TO SCHEDULE A TEMP POLE INSPECTION | |||
| WATER METER INSTALLATION REQUEST | 01/17/2020 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| PLFM | COMPLETE | 03/05/2021 | 03/05/2021 |
| Note: Released By: JORDAN MYERS - (386)986-2320 - JMEYERS@PALMCOASTGOV.COM The Final elevation certificate has been accepted | |||
| BADMIN | HOLD | 03/05/2021 | 03/05/2021 |
| Note: Held By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 03/05/2021 | 03/05/2021 |
| Note: Held By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM RENAME TO TERMITE.PDF | |||
| BADMIN | COMPLETE | 03/05/2021 | 03/05/2021 |
| Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM | |||
| PLFM | COMPLETE | 05/19/2020 | 05/19/2020 |
| Note: Released By: JMYERS The Foundation elevation certificate has been approved. Please provide Final prior to receiving CO. | |||
| ZON | COMPLETE | 05/19/2020 | 05/19/2020 |
| Note: Released By: AMOBLEY | |||
| ENGIN1 | COMPLETE | 05/19/2020 | 05/21/2020 |
| Note: Released By: TBAKER | |||
| ZON | COMPLETE | 03/04/2020 | 03/05/2020 |
| Note: Released By: AMOBLEY | |||
| SW1 | COMPLETE | 03/04/2020 | 03/06/2020 |
| Note: Released By: CTROHA | |||
| ENGIN1 | COMPLETE | 03/04/2020 | 03/05/2020 |
| Note: Released By: TBAKER | |||
| UD1 | COMPLETE | 03/04/2020 | 03/09/2020 |
| Note: Released By: MBACON | |||
| PLFM | COMPLETE | 03/04/2020 | 03/04/2020 |
| Note: Released By: JMYERS The Construciton elevation certificate has been approved. Please provide Building and Final prior to receiving CO. | |||
| PLFM | COMPLETE | 12/06/2019 | 12/06/2019 |
| Note: Released By: JMYERS The Construction elevation certificate has been approved. Please provide Building and Final prior to receiving CO. | |||
| SW1 | COMPLETE | 12/06/2019 | 12/09/2019 |
| Note: Released By: CTROHA | |||
| ZON | COMPLETE | 12/06/2019 | 12/09/2019 |
| Note: Released By: AMOBLEY | |||
| BLD | COMPLETE | 12/06/2019 | 12/13/2019 |
| Note: Released By: PBUCKLEY | |||
| ENGIN1 | COMPLETE | 12/04/2019 | 12/04/2019 |
| Note: Released By: TBAKER | |||
| ZON | HOLD | 11/22/2019 | 11/25/2019 |
| Note: Held By: AMOBLEY Please show setback on survey/site plan from driveway to property line to show that it will not encroach in the 5ft utility easement | |||
| PLFM | HOLD | 11/22/2019 | 11/22/2019 |
| Note: Held By: JMYERS Based on the Site Plan submitted on 11/22/19, the structure will fall inside the SFHA. Elevation certificates will be required at Construction Drawings, Foundation, and Final | |||
| SW1 | HOLD | 11/22/2019 | 11/22/2019 |
| Note: Held By: CTROHA Held By: CTROHA Must match existing elevations at the property line of adjacent improved lots and show proposed drainage conveyance elevations inside the property line Must provide a drainage plan to show how you are not going to impact neighboring lot. From a 9.00 to 7.70 in a 7.50 distance. Recommend lowering FFE | |||
| ELEC | COMPLETE | 11/22/2019 | 11/25/2019 |
| Note: Released By: JMUNSON | |||
| PLUM | COMPLETE | 11/22/2019 | 12/05/2019 |
| Note: Released By: FREODICA | |||
| BLD | HOLD | 11/22/2019 | 12/05/2019 |
| Note: Held By: FREODICA Submitted correction for Product approval sheet as requirement per FS 553.842: 1. On structural components: a. Wood connectors - FL 5113 - description does not match with Floorida product approval listing. b. Wood connectors - FL 2355 - description does not match wirh Florida product lapproval listing. c. Lintels - FL number is missing on submittal. FReodica -386-986-4734 | |||
| UD1 | COMPLETE | 11/22/2019 | 12/02/2019 |
| Note: Released By: AHALL | |||
| ENGIN1 | HOLD | 11/22/2019 | 11/22/2019 |
| Note: Held By: CTROHA Must match existing elevations at the property line of adjacent improved lots and show proposed drainage conveyance elevations inside the property line Must provide a drainage plan to show how you are not going to impact neighboring lot. From a 9.00 to 7.70 in a 7.50 distance. Recommend lowering FFE | |||
| MECH | COMPLETE | 10/30/2019 | 10/30/2019 |
| Note: Released By: CPISCITELLI | |||
| SWALE | COMPLETE | 10/23/2019 | 12/04/2019 |
| Note: Released By: TBAKER | |||
| PLFM | HOLD | 10/23/2019 | 10/23/2019 |
| Note: Held By: JMYERS Please provide an updated Site Plan that shows the proposed building and the Special Flood Hazard Area that resides on the lot. Should the structure or accessory machinery fall within the SFHA, 3 elevation certificates will be required. One at construction drawings, one at foundation, and one at final. | |||
| BLD | HOLD | 10/22/2019 | 10/30/2019 |
| Note: Held By: PBUCKLEY Please provide product approval numbers for structural componants and soffit per note I added to the Product Approval Sheet. | |||
| CUSVC | COMPLETE | 10/22/2019 | 10/23/2019 |
| Note: Released By: HHAND | |||
| ELEC | HOLD | 10/22/2019 | 10/25/2019 |
| Note: Held By: JMUNSON Need to submitt Load Calacs. NEC 2014 sec 220. Need outlet by A/C units. NEC 2014 sec 210.63 | |||
| ENGIN1 | COMPLETE | 10/22/2019 | 10/23/2019 |
| Note: Released By: TBAKER | |||
| LOCATE | COMPLETE | 10/22/2019 | 10/24/2019 |
| Note: Released By: CSTONE | |||
| MECH | HOLD | 10/22/2019 | 10/25/2019 |
| Note: Held By: CPISCITELLI Energy Calcs dont show Roof insulation value. Revise calcs. | |||
| PLUM | HOLD | 10/22/2019 | 10/30/2019 |
| Note: Held By: PBUCKLEY Please provide plumbing riser diagram for DWV system. | |||
| SW1 | HOLD | 10/22/2019 | 10/25/2019 |
| Note: Held By: JMUNSON (1) The Topographic Survey shall be signed, dated and sealed by an actively Licensed Florida Professional Surveyor - Mapper. (2) The signature and date must be under a raised seal. (3) Finished Floor Elevation (FFE) of the living area of improved structures on adjacent lots. (4) The elevations on all adjacent properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. (5) The elevations at 20 foot intervals along all property lines. (6) The interior elevations at no greater than a 20 foot grid. (7) The road centerline (RCL) and edge of pavement (EOP) elevations for roadways adjacent to and along all property lines, including EOP in cul-de-sacs at 9, 12, and 3 O’clock positions. (8) The elevations and/or inverts of all drainage structures within 100 feet of the property lines, including, culverts, inlets, swales, weirs, etc. both upstream and downstream of the property. This includes the ditch bottom and top of bank of ditches located on the property or in Reserved Parcels adjacent to the property. (9) All elevations are to be expressed to nearest 0.01 foot. (10) An on-site, third order, easily identifiable benchmark referenced to NAVD 1988 (e.g. fire hydrant, nail in power pole.) Pavement nails will not be accepted as benchmarks. (The bench mark must be maintained throughout the construction cycle and will be used in the swale plan and Final Survey). NAVD 1988 data sheets are available http://www.ngs.noaa.gov. | |||
| UD1 | COMPLETE | 10/22/2019 | 10/28/2019 |
| Note: Released By: MBACON Released By: AHALL | |||
| ZON | HOLD | 10/22/2019 | 10/23/2019 |
| Note: Held By: AMOBLEY Must provide site plan survey showing proposed building with setbacks from all adjoining properties, driveway width and material for review Must have a minimum of 16 foundation plantings with at least eight along front and four wrapping along each side. Landscape must also specify that AC pad is being screened with 7 gallon shrubs |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 03/05/2021 |
| NEW RESIDENTIAL INSPECTIONS | ¤664.00 | 12/16/2019 |
| SITE PLAN 20 | ¤20.00 | 12/16/2019 |
| SURCHARGE FS 533.721 | ¤14.82 | 12/16/2019 |
| SURCHARGE - FS 468.631 | ¤22.22 | 12/16/2019 |
| STORM WATER PERMIT FEES | ¤80.00 | 12/16/2019 |
| 3% TRANS IMPACT FEE CREDIT | (¤48.96) | 12/16/2019 |
| SEWER CREDIT | (¤2,465.75) | 12/16/2019 |
| SEWER INSPECTION | ¤25.00 | 12/16/2019 |
| SEWER CAPITAL FACILITY | ¤4,515.25 | 12/16/2019 |
| WATER CAPITAL FACILITY FEE | ¤3,314.84 | 12/16/2019 |
| METER - DEPOSIT | ¤60.00 | 12/16/2019 |
| WATER- TURN ON | ¤25.00 | 12/16/2019 |
| ADMIN FEE | ¤20.00 | 12/16/2019 |
| CONNECTION FEES | ¤985.25 | 12/16/2019 |
| ELECTRIC FEE | ¤259.20 | 12/16/2019 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.70) | 12/16/2019 |
| IMPACT FEE FIRE | ¤223.38 | 12/16/2019 |
| IMPACT FEE PARKS | ¤849.24 | 12/16/2019 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 12/16/2019 |
| IMPACT FEE TRANSPORTATION | ¤1,632.00 | 12/16/2019 |
| MECHANICAL FEE | ¤259.20 | 12/16/2019 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 12/16/2019 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 12/16/2019 |
| PLAN CHECK FEE | ¤132.80 | 12/16/2019 |
| PLUMBING FEE | ¤259.20 | 12/16/2019 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤14,479.51 |