I want to search for...
Permit #2019110160
Permit Details
Status: COED
| Parcel Id: 07-11-31-7030-00200-0140 |
| CONDITIONED SPACE: 1259 sqft |
| GARAGE: 395 sqft |
| OPENED PORCH (WITH ROOF) : 64 sqft |
| Total Square Footage: 1718 sqft |
| Block: 00200 |
| Subdivision: 2154 - SECTION 30-ROYAL PALMS |
| Job Phone: 386-931-2131 |
| Location Address: 25 RAINBOW LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/10/2019 |
| NOC: RECORDED |
| Applicant name: FLAGLER HABITAT |
| Owner: FLAGLER HABITAT FOR HUMANITY INC |
|
Address PO BOX 187 BUNNELL, FL 32110 |
| Lot: 0140 |
| Contracted Stated Job Value: ¤85,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
FLAGLER HABITAT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2 WEST MOODY BLVD BUNNELL, FL 32110 |
HABITAT | 386-931-2131 |
Sub Contractors
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
RICHARD H SIMMONS JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 1963 BUNNELL, FL 32110 |
ES12001217 (Exp: 08/31/2026) | 386-437-0607 | 386-437-1847 |
MICHAEL A PENAGOS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3321 GLENSHANE WAY ORMOND BEACH, FL 32174 |
CCC1330460 (Exp: 08/31/2026) | 386-569-9133 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/11/2020 | FINAL APPROVED | MMESSER |
| U -UTILITY RESIDENTIAL FINAL | 05/06/2020 | FINAL APPROVED | LFITZGERALD |
| ROW - STORMWATER FINAL | 05/05/2020 | APPROVED | MMAJEWSKI |
| ROW - FINAL APRON (AFTER POUR) | 05/04/2020 | APPROVED | MMAJEWSKI |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/30/2020 | APPROVED | MMAJEWSKI |
| FINAL SURVEY (OFFICE USE ONLY) | 04/30/2020 | APPROVED | MMAJEWSKI |
| ROW- PRE-APRON (PRE-POUR) | 04/08/2020 | APPROVED - AS NOTED | MMAJEWSKI |
| Note: THIS IS A REINSPECTION IT IS THE BUILDER’S RESPONSIBILITY: TO RECHECK ELEVATIONS AND PIPE SIZE, TO INSURE THAT AN OBSTRUCTION DOES NOT EXIST UPSTREAM AND OR DOWNSTREAM, THAT THE CULVERT PIPE IS SET TO AND OR FOLLOWS THE SWALE PLAN, FORM THE DRIVEWAY TO THE APPROVED SITE PLAN AND FOLLOW THE APPROVED DRIVEWAY DETAIL SHEET PROVIDED BY THE CITY OF PALM COAST. PRIOR TO PLACEMENT OF CONCRETE. | |||
| ROW- PRE-APRON (PRE-POUR) | 04/07/2020 | Disapproved - NO FEE | MMAJEWSKI |
| Note: CULVERT PIPE IS OUT OF TOLERANCE. CANNOT SLOPE MORE THAN A 0.10 IN THE DIRECTION OF THE DRAINAGE FLOW | |||
| ELECTRIC - EARLY POWER | 03/26/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: emailed fpl released power 11:00 | |||
| GRAVITY SEWER TEST | 03/03/2020 | APPROVED | JGIBSON |
| U - SEWER TIE IN | 03/03/2020 | APPROVED | JGIBSON |
| PEP TANK INSTALLATION REQUEST | 02/18/2020 | APPROVED | CSTONE |
| INSULATION | 02/07/2020 | APPROVED | FWILLIS |
| ALL ROUGH | 02/04/2020 | APPROVED | FWILLIS |
| ROOF VALLEY & METAL | 01/29/2020 | APPROVED | FWILLIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/28/2020 | APPROVED | JDELBONIS |
| WINDOW NAILING | 01/28/2020 | APPROVED | JDELBONIS |
| ELECTRIC TEMP POLE | 01/28/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 10:00 | |||
| FOUND SURVEY APPROVED (OFFICE) | 01/27/2020 | APPROVED | TBAKER |
| WALL SHEATHING | 01/08/2020 | APPROVED | FWILLIS |
| MONOLITHIC SLAB | 12/27/2019 | APPROVED | FWILLIS |
| PLUMBING 1ST ROUGH UNDERGROUND | 12/23/2019 | APPROVED | JGIBSON |
| WATER METER INSTALLATION REQUEST | 12/16/2019 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 01/22/2020 | 01/27/2020 |
| Note: Released By: TBAKER | |||
| CUSVC | COMPLETE | 12/04/2019 | 12/06/2019 |
| Note: Released By: AROSCOE | |||
| ZON | COMPLETE | 12/04/2019 | 12/05/2019 |
| Note: Released By: AMOBLEY | |||
| ELEC | COMPLETE | 12/04/2019 | 12/05/2019 |
| Note: Released By: JMUNSON | |||
| BLD | COMPLETE | 12/04/2019 | 12/09/2019 |
| Note: Released By: PBUCKLEY | |||
| BLD | HOLD | 11/05/2019 | 11/15/2019 |
| Note: Held By: PBUCKLEY Code Criteria must reference the home was designed to the Florida Building Code-Residential 6th Edition (2017). Code Criteria must reference the home was designed to the 2014 National Electric Code. Plans will need to be re-sealed by the engineer of record upon updating them to the current code edidtions mentioned above. | |||
| CUSVC | HOLD | 11/05/2019 | 11/05/2019 |
| Note: Held By: HHAND UTILITY APPLICATION IS NOT ATTACHED | |||
| ELEC | HOLD | 11/05/2019 | 11/13/2019 |
| Note: Held By: JMUNSON Need to have outlet outside on the back of the house. NEC 2014 art 210.52 (E) (1) | |||
| ENGIN1 | COMPLETE | 11/05/2019 | 11/05/2019 |
| Note: Released By: TBAKER | |||
| LOCATE | COMPLETE | 11/05/2019 | 11/07/2019 |
| Note: Released By: CSTONE | |||
| MECH | COMPLETE | 11/05/2019 | 11/06/2019 |
| Note: Released By: CPISCITELLI | |||
| PLUM | COMPLETE | 11/05/2019 | 11/15/2019 |
| Note: Released By: PBUCKLEY | |||
| SW1 | COMPLETE | 11/05/2019 | 11/06/2019 |
| Note: Released By: JMUNSON | |||
| UD1 | COMPLETE | 11/05/2019 | 11/12/2019 |
| Note: Released By: LFITZGERALD | |||
| ZON | HOLD | 11/05/2019 | 11/06/2019 |
| Note: Held By: AMOBLEY The color Mocha does not meet the LRV for an earth tone | |||
| SWALE | COMPLETE | 11/05/2019 | 12/11/2019 |
| Note: Released By: TBAKER |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| METER - DEPOSIT | ¤60.00 | 12/10/2019 |
| WATER- TURN ON | ¤25.00 | 12/10/2019 |
| ADMIN FEE | ¤20.00 | 12/10/2019 |
| CONNECTION FEES | ¤1,002.88 | 12/10/2019 |
| ELECTRIC FEE | ¤155.40 | 12/10/2019 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.70) | 12/10/2019 |
| IMPACT FEE FIRE | ¤223.38 | 12/10/2019 |
| IMPACT FEE PARKS | ¤849.24 | 12/10/2019 |
| IMPACT FEE TRANSPORTATION | ¤1,632.00 | 12/10/2019 |
| MECHANICAL FEE | ¤155.40 | 12/10/2019 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 12/10/2019 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 12/10/2019 |
| PLAN CHECK FEE | ¤63.60 | 12/10/2019 |
| PLUMBING FEE | ¤155.40 | 12/10/2019 |
| NEW RESIDENTIAL INSPECTIONS | ¤318.00 | 12/10/2019 |
| SITE PLAN 20 | ¤20.00 | 12/10/2019 |
| SURCHARGE FS 533.721 | ¤8.24 | 12/10/2019 |
| SURCHARGE - FS 468.631 | ¤12.36 | 12/10/2019 |
| STORM WATER PERMIT FEES | ¤80.00 | 12/10/2019 |
| 3% TRANS IMPACT FEE CREDIT | (¤48.96) | 12/10/2019 |
| SEWER CREDIT | (¤1,409.50) | 12/10/2019 |
| SEWER INSPECTION | ¤25.00 | 12/10/2019 |
| SEWER CAPITAL FACILITY | ¤4,596.07 | 12/10/2019 |
| WATER CAPITAL FACILITY FEE | ¤3,374.18 | 12/10/2019 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤11,310.51 |