I want to search for...
Permit #2019110588
Permit Details
Status: STATE
| Parcel Id: 07-11-31-7026-00480-0350 |
| Block: 00480 |
| Subdivision: 2153 - SECTION 26-PINE GROVE |
| Job Phone: 386-447-2202 |
| Location Address: 22 PIERCE LN |
| Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION |
| Issue Date: 01/09/2020 |
| NOC: Unknown |
| Applicant name: MICHAEL J LILLY |
| Owner: HERNANDEZ OSCAR T & WANDA A HERNANDEZ H&W |
|
Address 22 PIERCE LANE PALM COAST, FL 32164 |
| Lot: 0350 |
| Contracted Stated Job Value: ¤10,000.00 |
| Job Description: R&R DRYWALL,PLUMBING, & ELECTRIC ( MOVING RANGE & HOOD) |
| Type: CN |
Contractor
SERVPRO OF FLAGLER COUNTY
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
2205 DOBBS ROAD BUNNELL, FL 32110 |
CGC1514660 (Exp: 08/31/2024) | 904-429-4457 | 386-206-2188 |
Sub Contractors
AARON JOSHUA CRANDALL
| Status | Location Address | State License Number | Phone |
| INACTIVE |
1519 SOUTH DAYTONA AVE PALM COAST, FL 32164 |
CFC1425974 (Exp: 08/31/2026) | 386-931-6329 |
JOHN EDWARD GAMBONE
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
15 HARGROVE LN PALM COAST, FL 32137 |
1G PALM COAST, FL 32137 |
EC13006037 (Exp: 08/31/2026) | 386-586-9144 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC FINAL | 10/23/2020 | APPROVED | JMUNSON |
| Note: request electrical final inspection. | |||
| ELECTRIC FINAL | 10/13/2020 | Disapproved - NO FEE | RMARTIN |
| Note: THIS IS A REINSPECTION 10/13/20 OUTLET TO THE LEFT OF RANGE NEEDS TO BE GFCI PROTECTED NEC 210.8 | |||
| BLD - BUILDING FINAL | 03/27/2020 | CANCELLED BY APPLICANT | JCOLASANTI |
| Note: Due to covid-19 concerns inspectors are not entering occupied homes at this time. This type of Inspection has been cancelled until further notice. Additional information will be provided when appropriate. Permit will be extended if necessary. | |||
| ELECTRIC FINAL | 02/13/2020 | PARTIALLY APPROVED | RMARTIN |
| Note: WALLS GOOD NEED TO CALL ELECTRIC FINAL BACK IN WHEN ELECTRIC IS DONE | |||
| MONOLITHIC SLAB | 02/13/2020 | APPROVED | FWILLIS |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/05/2020 | APPROVED | JGIBSON |
| PLUMBING 2ND ROUGH | 02/05/2020 | APPROVED | JGIBSON |
| MONOLITHIC SLAB | 02/04/2020 | Disapproved - NO FEE | FWILLIS |
| Note: THIS IS A REINSPECTION Need Plumbing rough, Termite Bond and Compaction before slab can be poured. | |||
| ALL ROUGH | 02/04/2020 | Disapproved - NO FEE | FWILLIS |
| Note: THIS IS A REINSPECTION Need Plumbing rough. | |||
| ALL ROUGH | 01/17/2020 | Disapproved -FEE REQUIRED | WMILLER |
| Note: MUST PASS PLUMBING FIRST ROUGH AND MONO SLAB INSPECTIONS PRIOR TO ALL-ROUGH 1. NEED TO OBTAIN REVISION TO SHOW NEW LOCATION FOR WALLS, SINK, AND ADDED ELECTRIC. 2. NEED TO EXPOSE PLUMBING THAT WAS COVERED PRIOR TO INSPECTION. FOR NEW SINK LOCATION... UNCOVER WORK TO BE INSPECTED..FBC...P2503.2 6TH EDITION 3. NAIL PLATES ON ELECTRIC FBC E3802.1 (table), AND 3802.3.2 OR NEC 334.15 b. protection from physical damage. (6TH EDITION) 4. INCORRECT NAIL PLATES FOR PLUMBING... NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE. AND SHALL EXTEND NO LESS THAN 2 inches ABOVE SOLE PLATES AND BELOW TOP PLATES, (MUST BE MINIMUM OF 0.0575 inch., 1.463mm, 16 GAGE) (WHERE THE PIPE IS LESS THAN 1.5 inches FROM THE NEAREST EDGE) (6TH EDITION) | |||
| MONOLITHIC SLAB | 01/17/2020 | Disapproved - NO FEE | WMILLER |
| Note: MISSED REQUIRED INSPECTIONS, AND REVISION NEEDED WORK DOES NOT MATCH DRAWINGS (WALLS, SINK, AND ELECTRIC LOCATIONS) UNCOVER WORK TO BE INSPECTED..FBC...P2503.2 6TH EDITION MONO SLAB WAS POURED PRIOR TO INSPECTION OF PLUMBING FIRST ROUGH AND MONO SLAB. NEED TO EXPOSE NEW PLUMBING AND CALL INSPECTION S FOR WORK IN PROGRESS. pLUMBING FIRST INSPECTION INSPECTION HAS BEEN ADDED, CALL WHEN PLUMBING IS EXPOSED AND READY FOR INSPECTION | |||
| BLD - BUILDING FINAL | |||
| Note: THIS IS A REINSPECTION Due to covid-19 concerns inspectors are not entering occupied homes at this time. This type of Inspection has been cancelled until further notice. Additional information will be provided when appropriate. Permit will be extended if necessary. |
Review History
| Department | Status | Date In | Date Out |
| PLUM | COMPLETE | 01/28/2020 | 02/06/2020 |
| Note: Released By: FREODICA | |||
| ELEC | COMPLETE | 01/28/2020 | 01/30/2020 |
| Note: Released By: JMUNSON | |||
| ELEC | HOLD | 01/27/2020 | 01/28/2020 |
| Note: Held By: JMUNSON Need to show wire size and breaker size for new hood and range. | |||
| PLUM | COMPLETE | 12/11/2019 | 12/11/2019 |
| Note: Released By: FREODICA | |||
| BLD | COMPLETE | 11/15/2019 | 12/02/2019 |
| Note: Released By: FREODICA | |||
| ELEC | COMPLETE | 11/15/2019 | 11/19/2019 |
| Note: Released By: JMUNSON | |||
| PLUM | HOLD | 11/15/2019 | 12/02/2019 |
| Note: Held By: FREODICA Provide plumbing scope of work per FBC 6th ed.sec. 107.2.1. F.Reodica -386-986-4734 | |||
| ZON | COMPLETE | 11/15/2019 | 11/18/2019 |
| Note: Released By: AMOBLEY No zoning review needed. Interior work only |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN FEE | ¤20.00 | 01/09/2020 |
| ELECTRIC FEE | ¤66.00 | 01/09/2020 |
| PLAN CHECK FEE | ¤40.00 | 01/09/2020 |
| PLUMBING FEE | ¤66.00 | 01/09/2020 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 01/09/2020 |
| SITE PLAN 20 | ¤20.00 | 01/09/2020 |
| SURCHARGE FS 533.721 | ¤2.12 | 01/09/2020 |
| SURCHARGE - FS 468.631 | ¤3.18 | 01/09/2020 |
| REVISION | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| Fees | Total Due: ¤80.00 | Total Paid: ¤257.30 |